It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Clinical photon-counting CT (PCCT) offers a spatial resolution of about 200 µm and might allow for acquisitions close to conventional dental CBCTs. In this study, the capabilities of this new system in comparison to dental CBCTs shall be evaluated. All 8 apical osteolysis identified in CBCT were identified by both readers in all three PCCT scan protocols. Mean visibility scores showed statistical significant differences for root canals(p = 0.0001), periodontal space(p = 0.0090), cortical(p = 0.0003) and spongious bone(p = 0.0293) in favor of high and medium dose PCCT acquisitions. Overall, both devices showed excellent image quality of all structures assessed. Interrater-agreement showed high values for all protocols in all structures. Bland–Altman plots revealed a high concordance of both modalities with the reference measurements. In vitro, ultra-high resolution PCCT can reliably identify different diagnostic entities and structures relevant for dental diagnostics similar to conventional dental CBCT with similar radiation dose. Acquisitions of five cadaveric heads were performed in an experimental CT-system containing an ultra-high resolution PC detector (0.25 mm pixel size in isocenter) as well as in a dental CBCT scanner. Acquisitions were performed using dose levels of 8.5 mGy, 38.0 mGy and 66.5 mGy (CTDI16cm) in case of PCCT and of 8.94 mGy (CTDI16cm) in case of CBCT. The quality of delineation of hard tissues, root-canals, periodontal-space as well as apical osteolysis was assessed by two readers. Mean visibility scores and interrater-agreement (overall agreement (%)) were calculated. Vertical bone loss (bl) and thickness (bt) of the buccal bone lamina of 15 lower incisors were measured and compared to reference measurements by ore microscopy and clinical probing.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
; Sen, Sinan 2 ; Gehrig Holger 1 ; Bruckner, Thomas 3 ; Ti-Sun, Kim 1 ; Lux, Christopher J 4 ; Heinz-Peter, Schlemmer 5 ; Heinze, Sarah 6 ; Maier Joscha 7 ; Kachelrieß Marc 8 ; Sawall, Stefan 8 1 University Hospital Heidelberg, Section of Periodontology, Department of Operative Dentistry, Heidelberg, Germany (GRID:grid.5253.1) (ISNI:0000 0001 0328 4908)
2 University Hospital of Schleswig-Holstein, Department of Orthodontics, Kiel, Germany (GRID:grid.412468.d) (ISNI:0000 0004 0646 2097)
3 University Hospital Heidelberg, Institute of Medical Biometry, Heidelberg, Germany (GRID:grid.5253.1) (ISNI:0000 0001 0328 4908)
4 University Hospital Heidelberg, Department of Orthodontics, Heidelberg, Germany (GRID:grid.5253.1) (ISNI:0000 0001 0328 4908)
5 German Cancer Research Center (DKFZ), Heidelberg, Germany (GRID:grid.7497.d) (ISNI:0000 0004 0492 0584)
6 University Hospital Heidelberg, Institute of Forensic and Traffic Medicine, Heidelberg, Germany (GRID:grid.5253.1) (ISNI:0000 0001 0328 4908)
7 German Cancer Research Center (DKFZ), Division of X-Ray Imaging and CT, Heidelberg, Germany (GRID:grid.7497.d) (ISNI:0000 0004 0492 0584)
8 German Cancer Research Center (DKFZ), Division of X-Ray Imaging and CT, Heidelberg, Germany (GRID:grid.7497.d) (ISNI:0000 0004 0492 0584); Ruprecht-Karls-University Heidelberg, Medical Faculty, Heidelberg, Germany (GRID:grid.7700.0) (ISNI:0000 0001 2190 4373)




