It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
To estimate the effects of different intensities of intermittent pneumatic soft-tissue compression on bone defect repair in an animal model.
Methods
Five mm radial bone defect in length was made in 64 mature New Zealand rabbits and all animals randomly assigned into four groups: Group A (control group without compression), Group B (5–7 kPa intensity), Group C (8–10 kPa intensity) and Group D (11–13 kPa intensity). On the fourth day after surgery, their legs were intermittently pneumatic compressed for 4 weeks. The stimulation lasted 30 min every day and the frequency of compression was 15 Hz. New bone formation in 4 groups was evaluated by gross observation, X-ray, Micro-CT, and histological staining at 2 and 4 weeks after surgery.
Result
There was more new bony callus in the bone defect in group C than in other groups by gross observation and X-ray radiography at 2 and 4 weeks. The Micro-CT results showed more new bony callus, bone trabecula and higher bone mineral density in group C. Fluorescent labeling results showed the speed of new bone formation in Group C was faster than that in other groups, among which the control group had the slowest speed of new bone formation. The result of histology had shown that the trabeculae in bone callus in group C had a regular form, the trabeculae were wide and had a more become osteoblast around them.
Conclusion
The intermittent pneumatic soft-tissue compression can accelerate new bone formation of bone defects and the optimal intensity is 8–10 kPa for repairing the rabbit radial bone defect.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer