Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Tactile sensation is a highly desired function in robotics. Furthermore, tactile sensor arrays are crucial sensing elements in pulse diagnosis instruments. This paper presents the fabrication of an integrated piezoresistive normal force sensor through surface micromachining. The force sensor is transferred to a readout circuit chip via a temporary stiction effect handling process. The readout circuit chip comprises two complementary metal-oxide semiconductor operational amplifiers, which are redistributed to form an instrumentation amplifier. The sensor is released and temporarily bonded to the substrate before the transfer process due to the stiction effect to avoid the damage and movement of the diaphragm during subsequent flip-chip bonding. The released sensor is pulled off from the substrate and transferred to the readout circuit chip after being bonded to the readout circuit chip. The size of the transferred normal force sensor is 180 μm × 180 μm × 1.2 μm. The maximum misalignment of the flip-chip bonding process is approximately 1.5 μm, and sensitivity is 93.5 μV/μN/V. The routing of the piezoresistive Wheatstone bridge can be modified to develop shear force sensors; consequently, this technique can be used to develop tactile sensors that can sense both normal and shear forces.

Details

Title
Integrated Piezoresistive Normal Force Sensors Fabricated Using Transfer Processes with Stiction Effect Temporary Handling
Author
Liu, Ni 1 ; Zhong, Peng 2   VIAFID ORCID Logo  ; Zheng, Chaoyue 2 ; Sun, Ke 3 ; Zhong, Yifei 1 ; Yang, Heng 2   VIAFID ORCID Logo 

 Department of Nephrology, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai 200032, China; [email protected] 
 State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; [email protected] (P.Z.); [email protected] (C.Z.); [email protected] (K.S.); University of Chinese Academy of Sciences, Beijing 100049, China 
 State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; [email protected] (P.Z.); [email protected] (C.Z.); [email protected] (K.S.) 
First page
759
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
2072666X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2670326226
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.