Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: Phantom studies are widely used to assess variability in measurements. This study aimed to assess the reliability and accuracy of point Shear Wave elastography (pSWE) measurements of an elasticity phantom. Methods: Measurements were obtained by an experienced certified clinical sonographer at three different depth levels in kPa, using a curvilinear 5-1MHz transducer of the EPIQ7 ultrasound imaging system. Results: A total of 180 pSWE measurements were obtained at three different depth levels (three cm, five cm, and seven cm) of the phantom background. The mean CV of pSWE was low at all depths (3 cm: 8.8%; 5 cm: 7%; 7 cm: 7.2%). There was a significant difference between measurements at depths of 3 cm vs. 7 cm (MD: −0.85, 95% CI −1.5, −0.11, p = 0.024) and measurements at depths 5 cm vs. 7 cm (MD: −1.1, 95% CI −1.7, −0.47, p = 0.001). An overestimation of mean pSWE measurements at a depth of 7 cm was noted compared to the manufacturer’s value (2.7%, p = 0.006). Conclusions: Superficial phantom SWE measurements in this study had low variability compared to deep measurement. pSWE measurements at deep levels can be overestimated.

Details

Title
Effect of Depth on Ultrasound Point Shear Wave Elastography in an Elasticity Phantom
Author
Almutairi, Fahad F 1 ; Abdeen, Rawan 2 ; Jaber Alyami 1 ; Sultan, Salahaden R 2   VIAFID ORCID Logo 

 Department of Radiologic Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia; [email protected] (R.A.); [email protected] (J.A.); [email protected] (S.R.S.); Animal House Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia; Smart Medical Imaging Research Group, King Abdulaziz University, Jeddah 22252, Saudi Arabia 
 Department of Radiologic Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia; [email protected] (R.A.); [email protected] (J.A.); [email protected] (S.R.S.) 
First page
6295
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20763417
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2685975781
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.