Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Ultra-wideband radar application for sleep breathing monitoring is hampered by the difficulty of obtaining breathing signals for non-stationary subjects. This occurs due to imprecise signal clutter removal and poor body movement removal algorithms for extracting accurate breathing signals. Therefore, this paper proposed a Sleep Breathing Detection Algorithm (SBDA) to address this challenge. First, SBDA introduces the combination of variance feature with Discrete Wavelet Transform (DWT) to tackle the issue of clutter signals. This method used Daubechies wavelets with five levels of decomposition to satisfy the signal-to-noise ratio in the signal. Second, SBDA implements a curve fit based sinusoidal pattern algorithm for detecting periodic motion. The measurement was taken by comparing the R-square value to differentiate between chest and body movements. Last but not least, SBDA applied the Ensemble Empirical Mode Decomposition (EEMD) method for extracting breathing signals before transforming the signal to the frequency domain using Fast Fourier Transform (FFT) to obtain breathing rate. The analysis was conducted on 15 subjects with normal and abnormal ratings for sleep monitoring. All results were compared with two existing methods obtained from previous literature with Polysomnography (PSG) devices. The result found that SBDA effectively monitors breathing using IR-UWB as it has the lowest average percentage error with only 6.12% compared to the other two existing methods from past research implemented in this dataset.

Details

Title
Non-Contact Breathing Monitoring Using Sleep Breathing Detection Algorithm (SBDA) Based on UWB Radar Sensors
Author
Husaini, Muhammad 1   VIAFID ORCID Logo  ; Kamarudin, Latifah Munirah 1   VIAFID ORCID Logo  ; Zakaria, Ammar 2   VIAFID ORCID Logo  ; Kamarudin, Intan Kartika 3   VIAFID ORCID Logo  ; Muhammad Amin Ibrahim 4   VIAFID ORCID Logo  ; Nishizaki, Hiromitsu 5 ; Toyoura, Masahiro 6   VIAFID ORCID Logo  ; Mao, Xiaoyang 6 

 Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), Arau 02600, Perlis, Malaysia; [email protected] (M.H.); [email protected] (A.Z.); Advanced Sensor Technology, Centre of Exellence (CEASTech), Universiti Malaysia Perlis (UniMAP), Arau 02600, Perlis, Malaysia 
 Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), Arau 02600, Perlis, Malaysia; [email protected] (M.H.); [email protected] (A.Z.); Centre of Advanced Sensor and Technology, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia 
 Department of Otorhinolaryngology Head and Neck Surgery, Universiti Teknologi MARA, Shah Alam 47000, Selangor, Malaysia; [email protected] 
 Department of Internal Medicine, Faculty of Medicine, Universiti Teknologi MARA, Shah Alam 47000, Selangor, Malaysia; [email protected] 
 Faculty of Engineering, University of Yamanashi, Kofu 400-8511, Yamanashi, Japan; [email protected] 
 Department of Computer Science and Engineering, University of Yamanashi, Kofu 400-8511, Yamanashi, Japan; [email protected] (M.T.); [email protected] (X.M.) 
First page
5249
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
14248220
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2694063509
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.