Introduction
Graves’ disease (GD) is an organ-specific autoimmune disease of the thyroid gland that affects predominantly women (ratio about 8:1) between 30 and 50 years old and is the most common cause of hyperthyroidism in iodine-replete populations [1]. The mechanism of hyperthyroidism in GD is the production of autoantibodies to the Thyroid Stimulating Hormone Receptor (TSH-R) that mimic the effects of the thyrotropin. The TSH-R belongs to the family of 7TM G-protein coupled receptors and is expressed by thyroid follicular cells and, to a much lower level, by thymocytes and fibroblasts of retro-orbital tissue [2]. Based on their functional effect on TSH-R, three types of antibodies can be considered: stimulating, blocking, and cleaving (“neutral” in biological activity terms) TRAb [3]. The stimulating TRAb are the most common and the cause of hyperthyroidism in GD patients [4].
The autoantibodies to the TSH-R are of high affinity but remain at a low absolute concentration as they are produced by a limited number of clones of B lymphocytes and plasma cells and this may explain why in a few patients, the response may shift from producing predominantly stimulating to blocking or neutral antibodies with the corresponding change in the state of the thyroid function and the clinical symptoms [5, 6].
Like other autoimmune diseases, GD is a chronic condition that requires early diagnosis to prevent permanent tissue damage e.g., osteoporosis, ophthalmopathy, myopathy, and personality changes. The diagnostic is based on the recognition of the symptoms of hyperthyroidism, goiter, eye signs, and the measurement of thyroid hormones and TSH.
Measurement of TRAbs is important to confirm GD and rule out other causes of hyperthyroidism making the diagnosis much more accurate [7–9] and can be critical in cases of Graves’ Ophthalmopathy (GO) [10, 11] without hyperthyroidism. Since the discovery of TRAb more than 60 years ago as long-acting thyroid stimulator (LATS) by Adams and Purves [12], the measurement of TRAb has progressively improved in sensitivity, specificity, reliability, and usability and this has expanded its clinical application as reflected in many recent guidelines and surveys [13–17].
TRAb tests can be divided into main two categories depending on the detection method used: competition immunoassays and bioassays. Competition immunoassays detect all types of anti-TRAbs by measuring their ability to compete with a labeled ligand (TSH or a monoclonal antibody (MoAb) to TSH-R) for binding to the TSH receptor. Bioassays can detect the stimulating or blocking effect of the TRAb by measuring the production cAMP, the TSH-R intracellular signal, by cells expressing the TSH-R [11, 14]. Even if discrimination among the types of TRAbs could be of great interest in given clinical situations, such as in cases of unexplained changes in the thyroid function during or after pregnancy [18], competition immunoassays, that are easier, faster, and can be automated, are the tests commonly used in clinical diagnostic laboratories.
TRAb are autoantibodies and as such, they are not a molecularly defined analyte but a mixture of high-affinity IgG that bind selected epitopes of the TSH-R that varies among individuals and fluctuates within one individual. Small changes in the level, affinity, or fine specificity of the TRAb can result in major changes in their capacity to activate the TSH-R. Measuring TRAbs is, therefore, challenging, and generations of tests using different TSH-R preparations and ligands have been developed over the years, while in parallel, labeling and detection methods have also improved for the immunoassays in general. Therefore, the number of reports comparing tests in terms of sensitivity, specificity, safety, and cost-effectiveness as applied to different populations, have grown over the years [19–25] reflecting that none of them have yet met all the expectations of the clinical endocrinologist.
Therefore, the objective of this work is to compare the accuracy in terms of sensitivity and specificity of two automated 3rd generation immunoassays in use for TRAb testing of a clinical laboratory.
Materials and methods
A comparative study was designed and conducted from February 2019 to July 2019 and the STARD guidelines were followed. The project was carried out at the Clinical Laboratories of Hospital Universitario Dr. Peset in Valencia (Spain), ISO 9001:2015 certified.
Informed consent was not requested as per ethics committee indication. The reason is that data was appropriately anonymized and all determinations were requested by specialists as part of the routine diagnostic testing. The study just included the determination requested by the specialists performed with two different methods. Medical decisions were taken according to the Hopitals’ routine testing method results.
Patients
Baseline demographics and clinical characteristics of patients are given in Table 1.
[Figure omitted. See PDF.]
Participants were divided in different clinical groups according to their diagnosis (Table 1 and Fig 1):
1. Group 1: 29 newly diagnosed untreated GD patients (NDGD)
2. Group 2: composed by 27 cases of GD patients in remission (GD-R)
3. Group 3: composed by 76 cases of GD patients under treatment, GD-T
4. Group 4: 18 cases of Autoimmune Thyroiditis (AIT), composed by 11 classical Hashimoto’s thyroiditis and 7 postpartum thyroiditis, as assessed by TPO positive antibodies, imaging and hormones levels.
5. Group 5: 35 patients with non-toxic Multinodular Goiter (MNG) as assessed by history, image, and hormone levels.
6. Group 6: Other Thyroid Diseases (OTD), 56 patients with thyroid diseases other than GD, i.e., non-immune hyper or hypothyroidism, iatrogenic thyroid disorders, single thyroid nodules, and thyroid cancer.
7. Group 7: Miscellaneous (MISC), 60 cases referred to our laboratory because of diseases unrelated to thyroid pathology. This group was considered the control group in the study.
[Figure omitted. See PDF.]
We did not make a category of patients with Graves’ Orbitopathy (GO), due to the low number of patients with GO (n = 3).
Thyroid pathology diagnoses were established by qualified endocrinologists from Endocrinology and Nutrition Service from Hospital Universitario Dr. Peset, according to the American Thyroid Association and European Thyroid Association guidelines [13, 15].
Samples
Eligibility criteria.
Consecutive samples received at the laboratory for TRAb testing from both Primary Care and Endocrinology specialists. To be included samples had to conform to the general pre-analytical requirements of the laboratory as established in the corresponding Standard Operating Procedure. None was excluded because of hemolysis, lipemia, or bilirubin, as these features do not interfere with the tests according to the specifications of the method. A total of 307 samples were initially tested but 6 were excluded from analysis, 2 due to incomplete clinical information, and 4 because they were duplicates. Results from 301 samples were used for the statistical analysis.
TRAb test measurement methods
TRAb were measured in freshly obtained or -80ºC kept serum samples in parallel by two immunoassays, the fluorescence enzyme immunoassay (FEIA) EliA™ anti-TSH-R that uses the Phadia 250 auto-analyzer (Phadia A.B, Thermo Fisher Scientific, Uppsala, Sweden) and the electrochemiluminiscent immunoassay (ECLIA) Elecsys® anti-TSH-R method run in a COBAS 6000 auto-analyzer (Roche Diagnostics International Ltd, Basel, Switzerland).
The EliA™ anti-TSH-R test is an immunoassay that detects both stimulating and blocking antibodies. It is a competitive assay based on a human recombinant TSH-R (rTSH-R) immobilized to a solid phase (wells). Serum samples are dispensed to the wells for TRAb autoantibodies to bind to the TSH-R. A β-galactosidase labeled mouse monoclonal stimulating anti-TSH-R antibody is added in a second step. This MoAb binds the TSH-R epitopes that remain free after the patients’ antibodies binding. After washing the free antibodies, the substrate for generating the fluorochrome is added and after a short incubation, the reaction is arrested and fluorescence measured: intensity is inversely proportional to TRAb in the problem sample. Finally, the fluorescence readings are converted into a titer of anti-TSH-R antibodies using a 6-point calibration curve [24].
The Elecsys® anti-TSH-R method (Roche Diagnostics Ltd, Basel, Switzerland), is also an immunoassay that works using the same competitive principle as EliA™ test, but with three major differences: it uses an immobilized purified porcine TSH-R (pTSH-R) as antigen, a human monoclonal stimulating autoantibody, M22, labeled with ruthenium as a competitor, and a chemiluminescent based detection. The more antibodies present in the patient serum sample, the less luminescence is detected in the final measurement [25].
Both assays were carried out according to manufacturer specifications. Their most relevant technical parameters are showed in Table 2.
[Figure omitted. See PDF.]
Statistical analysis
The number of patients required for this study was estimated by extrapolation from reference reports describing similar accuracy comparative studies for TRAb measurement (24,25).
For calculating the diagnostic accuracy of the tests, results from patients already under treatment were not included as anti-thyroid drugs may reduce TRAb levels. Results in the grey zone for EliA™ test were considered negative in this comparison.
Statistical analysis was performed using SAS system 9.4 (SAS, Cary, USA) and GraphPad Prism (GraphPad Software, San Diego, USA) software packages. A two-sided value of p < 0.05 was considered statistically significant.
The results were compared as quantitative and qualitative variables, by applying Spearman’s correlation and Passing-Bablok respectively. TRAb values below the lower limits and over the upper limits of quantitation (LoQ and UpQ respectively) were considered equal to limit values for statistical purposes. Bland-Altman test was not applicable as the Shapiro-Wilk test showed that TRAb results were not normally distributed. Results are given as median with range and the subsequent statistical analysis was performed with Cohen’s kappa to study the agreement of categorical variables (positive vs. negative) and Kruskal-Wallis test to compare the groups of patients.
Receiver operating characteristic (ROC) curves were plotted and analyzed using Analyse-it Version 4.60 for Microsoft Excel (Leeds, UK) to compare the area under the curve (AUC) by both methods. Clinical sensitivity, specificity, predictive value, and likelihood ratio (LR) were also calculated.
Results and discussion
Anti-TSH-R immunoassays performance comparison
The main results are summarized in Table 3. Spearman correlation showed significant positive linearity of results for both tests (0.725). It was therefore adequate to apply the Passing-Bablok test where the titers from both tests were shown not to be comparable as they showed systematic and proportional differences (Fig 2).
[Figure omitted. See PDF.]
Correlation between EliA™ and Elecsys® TRAb. TRAb are displayed in UI/l. Dotted line (- - - -) corresponds to identity. Blue line corresponds to Passing Bablock regression and double dotted line (-- -- --) to 95% CI bands. Tests values are displayed as orange circles.
[Figure omitted. See PDF.]
Bland-Altman plot was performed for a specific descriptive purpose, as the result differences were not normally distributed according to Shapiro-Wilk test p<0.0001 (Fig 3) and therefore this is not the most adequate representation for the results of these tests.
[Figure omitted. See PDF.]
Inter-assay agreement between EliA™ and Elecsys® TRAb. The dashed line (........) corresponds to bias. Lower (-8.036) and upper (6.195) 95% limits of agreement are plotted as speckled lines. Y-axis plots the difference scores of EliA™ and Elecsys® TRAb measurements against the mean for each studied sample.
Cohen’s kappa index for categorized values was k = 0.8176, indicating strong agreement which was higher for negative than for positive results (99.5% and 78.5%, respectively).
The comparison between paired clinical groups, performed by Kruskal-Wallis test (Fig 4) showed that NDGD is statistically different from all the other groups for both Elecsys® and EliA™ methods, with the logical exception of GD-T.
[Figure omitted. See PDF.]
A. Elecsys® TRAb levels in the different groups enrolled in the study. B. EliA™ TRAb levels in the different groups enrolled in the study. TRAb levels are displayed as data ranks obtained by transforming to continue data ranks using Roche’s test. For each box plot, the central line represents the median; the boxes limits represent the upper and lower quartile; black points are outliers (a value more than 1.5 times the interquartile range above/below the interquartile values); and the black lines are the whiskers, which extend from the interquartile ranges to the maximum values that are not classed as outliers.
NDGD, newly diagnosed untreated GD patients; GD-R, GD patients in remission; GD-T, GD patients under treatment; AIT, Autoimmune Thyroiditis; MNG, Multinodular Goiter non-toxic; OTD, Other Thyroid Diseases; MISC, Miscellaneous.
According to ROC analysis (Fig 5), the optimal cut-off (OCO) for EliA™ method is 3.2 IU/L, at which the EliA™ method has a sensitivity of 96.6% and a specificity of 99.4%
[Figure omitted. See PDF.]
ROC curve of both methods at manufacturer cut-off values.
The sensitivity and specificity of Elecsys® method at the manufacturer given cut-off value, 1.75 IU/L, are 100% and 95.3% respectively.
The area under the curve (AUC) for Elecsys® was 0.995 and 0.996 for EliA™. They showed the high diagnostic efficiency of both methods with a minimal non-statistically significant difference.
The value of TRAb measurement in GD diagnosis and treatment monitoring is widely accepted in clinical practice and it is now included in scientific society guidelines. Even though currently used competitive assays do not distinguish between the different types of TRAb activities, overall binding TSH inhibition measurement is sufficient for supporting clinical diagnosis in most cases. The exceptions are a few complex clinical situations such as neonatal hyperthyroidism where a bioassay could be useful [14].
Given the different calibration standards used, Elecsys® and EliA™ results are not directly comparable. This lack of direct comparability among 3rd generation methods has already been reported [21]. Articles comparing different TRAb assays including the EliA™ or the Elecsys® tests have been published, but to our knowledge, this is the first head-to-head direct comparison (Table 4).
[Figure omitted. See PDF.]
In our analysis, the Elecsys® shows slightly higher sensitivity while the EliA™ test a slightly higher specificity. Villalta et al. [24] compared EliA™ with TRAK™ RIA, Brahms (Thermo Scientific, Hennigsdorf, Germany) and Immulite™ TSI assay (Siemens Healthcare, Llanberis, UK) but not the Elecsys. For the EliA™ test the reported specificity of 99.6% is very similar to the 99.4% in our study, but in our series the optimal cut-off of 3.2 IU/L is closer to the upper limit of normality provided by the manufacturer, and slightly lower than the optimal cut-off of 3.8 IU/L reported in their paper.
In the report of Struja et al. [25], the EliA™ test was the most specific (97.9% at the manufacturer cut-off of 3.3 IU/L) and showed a specificity of 97.7% at the same cut-off in Luthers’ work [26]. Sensitivity was much lower in Struja and Luther series (71.7% and 79% respectively), but both studies included GD patients under treatment while we did not.
In the paper of Villalta et al. [24] the EliA™ sensitivity for untreated GD was of 94.7% which is slightly lower than our result of 96.6%. Adopting their cut-off point to our series, the sensitivity would be down to 73.8% because some of our untreated GD patients (5/29) are in the low positive range, from 3.3 to 3.8 IU/L.
In relation to Elecsys® anti-TSH-R method, Dourudian et al. found a sensitivity of 95% and a specificity of 97% when comparing their GD patients to a healthy control group [23] However, when they compared GD patients to a mixed group of healthy and disease controls, the specificity decreased to 90%. The sensitivity of Elecsys® in our series is 100%, as we did include any case of seronegative GD during the period of the study. We may have to re-assess this issue in future work.
There is a good concordance between Elecsys® and EliA™ for negative results and a total concordance for clearly positive results. The controversy is focused on Elecsys® low positives that could be equivocal/negative for EliA™. But this is an expected result when comparing one assay that prioritizes sensitivity with another prioritizing specificity. In their comparative study, Autilio et al. [27] found the four near cut-off false positives Elecsys® corresponding to chronic autoimmune thyroiditis cases. We also found six near cut-off positives by Elecsys® that by EliA™ were five negative and one equivocal, all of them corresponded to the OTD group.
A patient from OTD group with a nodular thyroid gland having a single dominant nodule was positive for both methods, but in this case, we cannot strictly consider this a false positive as overlapping cases of GD and multinodular thyroid are not rare.
The overall impression considering quantitative and qualitative results is that both Elecsys® and EliA™ are good methods for TRAb measurement in clinical laboratories. Whether to prioritize sensitivity or specificity and how to manage the results around cut-off and how to deal with grey zone results are difficult questions. The fundamentals of the two methods are different for these aspects. EliA™ prioritizes specificity and defines a grey zone to report intermediate results. Elecsys®, at the manufacturer’s cut-off value of 1.75 IU/L, clearly prioritizes sensitivity.
In this study, we have focused on test performance, however, other test characteristics like assay time, sample volume, and precision are also worthy of evaluation when selecting the appropriate test for a specific laboratory. Nevertheless, it is difficult to draw general conclusions, as their impact mainly depends on the type of laboratory system used, and the laboratory workflow. Sample volume is not critical in daily routine, however, lower volume sample needs are always better for patients.
As other studies have suggested [28], our results support the use of a higher cut-off point for the Elecsys® test in clinical laboratory use, as our preference is to prioritize a higher specificity. In principle, for low prevalence diseases as most autoimmune diseases, a small reduction in specificity is translated into an excess of false positives, as compared to false negatives caused by a small reduction in sensitivity. Moreover, this test is much more a confirmatory test than a screening test in the diagnostic strategy of GD, addressing a parameter in which positivity has been sometimes considered pathognomonic [29, 30].
In the same line with the results from Villalta et al. [24] series for Hashimoto’s thyroiditis patients, we observed an absence of TRAb positivity in our AIT patients group.
In relation to establishing a single cut-off or considering grey zones, both ways to report results are perfectly valid if the interpretation is carefully reported to the clinicians. It is also important that clinicians understand the limitations of the technique in use, and this is the role of clinical laboratory specialists.
Our study has two main limitations, first, we did not include a healthy patients group as the negative control, which is always good to have. Second, we did not evaluate the performance of both tests for patients’ disease follow-up and relapse prediction. This is also a key point when deciding which test to include in the daily routine, and our next objective as follow-up performance data is scarce on TRAb measurement methods.
Conclusions
In conclusion, both methods are perfectly valid and useful for routine TRAb analysis, with a trend to specificity in the case of EliA™. Moreover, it is very important to raise awareness to the clinicians on the proper interpretation of results falling in the grey zone or close to cut-off values. Given the increasing agreement on literature about TRAb utility in GD diagnosis and management and in order to minimize costs, TRAb measurements must be appropriately integrated into the routine of GD diagnosis and management.
Supporting information
S1 Graphical abstract.
https://doi.org/10.1371/journal.pone.0270890.s001
(TIF)
Acknowledgments
We greatly acknowledge to Dr. Ricardo Pujol Borrell -Immunology Division Senior Consultant at Hospital Universitari Vall D’Hebrón- for his kind support during manuscript edition and Dr. Elisa Caballero Calabuig and Dr. Marcelino Gómez Balaguer—Nuclear Medicine and Endocrinology Services from Hospital Universitario Dr. Peset- for their kind advice and collaboration to clinical data evaluation. Finally, we want to acknowledge Thermo Fisher Scientific for providing TSH-R tests.
Citation: López Ortega JM, Martínez PS, Acevedo-León D, Capell NE (2022) Anti-TSH receptor antibodies (TRAb): Comparison of two third generation automated immunoassays broadly used in clinical laboratories and results interpretation. PLoS ONE 17(7): e0270890. https://doi.org/10.1371/journal.pone.0270890
About the Authors:
José María López Ortega
Contributed equally to this work with: José María López Ortega, Pilar Salvador Martínez, Delia Acevedo-León, Núria Estañ Capell
Roles: Conceptualization, Data curation, Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Writing – original draft, Writing – review & editing
E-mail: [email protected]
Affiliation: Autoimmunity and Allergy Division, Clinical Laboratories, Dr. Peset University Hospital, Valencia, Spain
https://orcid.org/0000-0003-0542-6505
Pilar Salvador Martínez
Contributed equally to this work with: José María López Ortega, Pilar Salvador Martínez, Delia Acevedo-León, Núria Estañ Capell
Roles: Conceptualization, Supervision, Validation, Writing – review & editing
Affiliation: Autoimmunity and Allergy Division, Clinical Laboratories, Dr. Peset University Hospital, Valencia, Spain
Delia Acevedo-León
Contributed equally to this work with: José María López Ortega, Pilar Salvador Martínez, Delia Acevedo-León, Núria Estañ Capell
Roles: Investigation, Supervision, Validation, Writing – review & editing
Affiliation: Hormones and Immunology Division, Clinical Laboratories, Dr. Peset University Hospital, Valencia, Spain
https://orcid.org/0000-0001-8070-374X
Núria Estañ Capell
Contributed equally to this work with: José María López Ortega, Pilar Salvador Martínez, Delia Acevedo-León, Núria Estañ Capell
Roles: Investigation, Supervision, Validation, Writing – review & editing
Affiliation: Hormones and Immunology Division, Clinical Laboratories, Dr. Peset University Hospital, Valencia, Spain
1. Taylor PN, Albrecht D, Scholz A, Gutierrez-Buey G, Lazarus JH, Dayan CM, et al. Global epidemiology of hyperthyroidism and hypothyroidism. Vol. 14, Nat Rev Endocrinol. 2018; 14(5):301–316. pmid:29569622
2. Giménez-Barcons M, Colobran R, Gómez-Pau A, Marín-Sánchez A, Casteràs A, Obiols G, et al. Graves’ disease TSHR-stimulating antibodies (TSAbs) induce the activation of immature thymocytes: a clue to the riddle of TSAbs generation? J Immunol. 2015;194(9):4199–4206. pmid:25801430
3. Morshed S, Davies T. Graves’ disease mechanisms: The role of stimulating, blocking, and cleavage region TSH receptor antibodies. Horm Metab Res. 2015 14;47(10):727–734. pmid:26361259
4. Effraimidis G, Wiersinga WM. Mechanisms in endocrinology: autoimmune thyroid disease: old and new players. Eur J Endocrinol. 2014;170(6):R241–52. pmid:24609834
5. Davies TF, Latif R. Editorial: TSH receptor and autoimmunity. Front Endocrinology. (Lausanne). 2019;10:19. pmid:30761086
6. Wong M, Inder WJ. Alternating hyperthyroidism and hypothyroidism in Graves’ disease. Clin Case Rep. 2018;6(9):1684–1688. pmid:30214742
7. Quadbeck B, Hoermann R, Roggenbuck U, Hahn S, Mann K, Janssen O. Sensitive thyrotropin and thyrotropin-receptor antibody determinations one month after discontinuation of antithyroid drug treatment as predictors of relapse in Graves’ disease. Thyroid. 2005;15(9):1047–1054. pmid:16187913
8. Gastaldi R, Poggi E, Mussa A, Weber G, Vigone MC, Salerno M, et al. Graves disease in children: Thyroid-stimulating hormone receptor antibodies as remission markers. J Pediatr. 2014;164(5):1189–1194..e1. pmid:24518168
9. Bell L, Hunter AL, Kyriacou A, Mukherjee A, Syed AA. Clinical diagnosis of Graves’ or non-Graves’ hyperthyroidism compared to TSH receptor antibody test. Endocr Connect. 2018;7(4):504–510. pmid:29531156
10. Jang SY, Shin DY, Lee EJ, Lee SY, Yoon JS. Relevance of TSH-receptor antibody levels in predicting disease course in Graves’ orbitopathy: Comparison of the third-generation TBII assay and Mc4-TSI bioassay. Eye. 2013;27(8):964–971.: pmid:23743527
11. Barbesino G, Tomer Y. Clinical utility of TSH receptor antibodies. Vol. 98, Journal of Clinical Endocrinology and Metabolism. 2013. p. 2247–2255. pmid:23539719
12. Adams D, Purves H. Abnormal responses in the assay of thyrotropin. Proc Univ Otago Med School. 1956; 34:11–12.
13. Tozzoli R, Bagnasco M, Giavarina D, Bizzaro N. TSH receptor autoantibody immunoassay in patients with Graves’ disease: Improvement of diagnostic accuracy over different generations of methods. Systematic review and meta-analysis. Autoimmun Rev. 2012; 12(2):107–113. pmid:22776786
14. Tozzoli R. The increasing clinical relevance of thyroid-stimulating hormone receptor autoantibodies and the concurrent evolution of assay methods in autoimmune hyperthyroidism. J Lab Precis Med. 2018;3:27. https://jlpm.amegroups.com/article/view/4282/5285.
15. Ross D, Burch H, Cooper D, Greenlee M, Laurberg P, Maia A, et al. 2016 American Thyroid Association Guidelines for Diagnosis and Management of Hyperthyroidism and Other Causes of Thyrotoxicosis. Thyroid. 2016;26(10):1343–1421. pmid:27521067
16. Goichot B, Leenhardt L, Massart C, Raverot V, Tramalloni J, Iraqi H. Diagnostic procedure in suspected Graves’ disease. Ann Endocrinol (Paris). 2018;79(6):608–617. pmid:30220410
17. Kahaly G, Bartalena L, Hegedüs L, Leenhardt L, Poppe K, Pearce S. 2018 European thyroid association guideline for the management of Graves’ hyperthyroidism. Eur Thyroid J. 2018;7(4):167–186. pmid:30283735
18. Kung A, Jones B. A change from stimulatory to blocking antibody activity in Graves’ disease during pregnancy. J Clin Endocrinol Metab. 1998;83(2):514–518. pmid:9467567
19. Massart C, Sapin R, Gibassier J, Agin A, D’Herbomez M. Intermethod variability in TSH-receptor antibody measurement: Implication for the diagnosis of Graves disease and for the follow-up of Graves ophthalmopathy. Clin Chem. 2009;55(1):183–186. pmid:19028818
20. Massart C, D’Herbomez M. Thyroid-stimulating hormone receptor antibody assays: Recommendation for correct interpretation of results in Graves disease. Clin Chem. 2013;59(5):855. pmid:23396139
21. Tozzoli R, Kodermaz G, Villalta D, Bagnasco M, Pesce G, Bizzaro N. Accuracy of receptor-based methods for detection of thyrotropin-receptor autoantibodies: A new automated third-generation immunoassay shows higher analytical and clinical sensitivity for the differential diagnosis of hyperthyroidism. Autoimmun Highlights. 2010;1(2):95–100. pmid:26000113
22. Diana T, Wüster C, Olivo P, Unterrainer A, König J, Kanitz M, et al. Performance and Specificity of 6 Immunoassays for TSH Receptor Antibodies: A Multicenter Study. Eur Thyroid J. 2017;6(5):243–9. pmid:29071236
23. Doroudian S, Pedersen IB, Knudsen CS, Handberg A, Andersen SL. Comparison of three competitive immunoassays for measurement of TSH receptor antibodies in patients with Graves’ disease. Scand J Clin Lab Invest. 2017;77(7):535–40. pmid:28737965
24. Villalta D, D’Aurizio F, Da Re M, Ricci D, Latrofa F, Tozzoli R. Diagnostic accuracy of a new fluoroenzyme immunoassay for the detection of TSH receptor autoantibodies in Graves’ disease. Auto Immun Highlights. 2018;9(1):3. pmid:29435670
25. Struja T, Jutzi R, Imahorn N, Kaeslin M, Boesiger F, Kutz A, et al. Comparison of Five TSH-receptor antibody assays in Graves’ disease: Results from an observational pilot study. BMC Endocr Disord. 2019;19(1):38. pmid:31023276
26. Luther T, Sjölander S, Kast M, Konrad C. Clinical performance of anti-TSH-R. Freiburg: Thermo-Fisher Scientific and the identifier form the last page 55-5501-26; 2017.
27. Autilio C, Morelli R, Locantore P, Pontecorvi A, Zuppi C, Carrozza C. Stimulating TSH receptor autoantibodies immunoassay: analytical evaluation and clinical performance in Graves’ disease. Ann Clin Biochem. 2018;55(1):172–177. pmid:28388869
28. Noh J, Miyazaki N, Ito K, Takeda K, Hiramatsu S, Morita S, et al. Evaluation of a New Rapid and Fully Automated Electrochemiluminescence Immunoassay for Thyrotropin Receptor Autoantibodies. Thryroid Res. 2018;11(1):2. pmid:19014323
29. Rydzewska M, Jaromin M, Pasierowska IE, Stozek K, Bossowski A. Role of the T and B lymphocytes in pathogenesis of autoimmune thyroid diseases. Thyroid Res. 2018;11(1). pmid:29449887
30. Menconi F, Oppenheim Y, Tomer Y. Graves Disease. In: Shoenfeld Y et al., editor. Diagnostic Criteria in Autoimmune Diseases. Humana Press (Totowa, NJ 07512 USA); 2008. pp 231–235.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2022 López Ortega et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Graves’ disease (GD) is the most common cause of hyperthyroidism in iodine-replete populations. It is an autoimmune disease caused by autoantibodies to the TSHR (TRAb). Although the diagnostic is mainly clinical, measuring TRAb improves accuracy and provides valuable prognostic information. The aim of this study was to compare the performance of two of the most widely used immunoassays i.e., EliA™ anti-TSH-R and Elecsys® anti-TSH-R. We have carried out a comparative study measuring TRAb by the two immunoassays in consecutive sera samples referred to the laboratory for TRAb measurement. Autoantibodies were measured in all samples in parallel by the two techniques. The two techniques were highly concordant as demonstrated by a Cohen’s kappa of 0.82. At the manufacturer recommended cut-off, sensitivity of Elecsys® TRAb test was higher (100% vs. 96.6%), while specificity of the EliA™ TRAb test was higher (99.4% vs. 95.3%). In most patients TRAb are detected by any of two tests which are both well suited for Clinical Laboratories use. However, a higher specificity may constitute an advantage for measurement used not for screening but for diagnostic purposes, as anti-TSH-R is.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer