Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Featured Application

Conventional vs. digital impressions for soft tissue change.

Abstract

Traditionally, soft tissue records are obtained by dental impression using impression materials; however, accurately recording the soft tissue immediately after tooth extraction is difficult. We measured the tissue changes after tooth extraction and compared two impression modalities (digital versus conventional) by measuring the changes at the soft tissue level. In this case, 15 patients with 17 single extraction sites were enrolled. Conventional impression (CI) using vinyl polysiloxane material and digital impression (DI) using an intraoral scanner were prepared immediately after extraction (T0) and at 2 months post-extraction (T1). Standard tessellation language files were generated for superimposition of the tissue surface. The tissue changes and discrepancies were measured on the superimposed surfaces. The differences in the changes and the discrepancy between the tissue surface impression at each time point were compared. At all measuring levels, the total tissue change was significantly different between groups DI and CI (p < 0.05). DI exhibited a more pronounced tissue surface at both time points, and the total discrepancy was statistically significantly greater at T0 than at T1 (p < 0.05). The values from DI and CI demonstrated small but significantly different for the same study material. The interpretation of such differences may depend on the clinical situation or scientific value.

Details

Title
Dimensional Changes in Extraction Sockets: A Pilot Study Evaluating Differences between Digital and Conventional Impressions
Author
Min-Woo Baek 1   VIAFID ORCID Logo  ; Hyun-Chang, Lim 2   VIAFID ORCID Logo  ; Noh, Kwantae 3 ; Seong-Ho, Choi 4   VIAFID ORCID Logo  ; Dong-Woon, Lee 5   VIAFID ORCID Logo 

 Department of Periodontology, Dental Hospital, Veterans Health Service Medical Center, Seoul 05368, Korea; [email protected] 
 Department of Periodontology, Periodontal-Implant Clinical Research Institute, School of Dentistry, Kyung Hee University, Seoul 02447, Korea; [email protected] 
 Department of Prosthodontics, School of Dentistry, Kyung Hee University, Seoul 02447, Korea; [email protected] 
 Department of Periodontology, College of Dentistry, Research Institute for Periodontal Regeneration, Yonsei University, Seoul 03722, Korea; [email protected] 
 Department of Periodontology, Dental Hospital, Veterans Health Service Medical Center, Seoul 05368, Korea; [email protected]; Department of Periodontology, Dental Hospital, Wonkwang University College of Dentistry, Iksan 54538, Korea 
First page
7662
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20763417
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2700544871
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.