Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Aim: The conometric concept was proposed as a possible connection between the abutment and the prosthetic coping. This research aimed to review the features and possible clinical uses of this connection in an implant-supported fixed prosthesis. Methods: An electronic search was conducted on an online database for the topic in object; articles published in international literature were considered and the research gave 17 results, and 6 parameters were analyzed. Results: This connection eliminated the possibility of cement residues in the subgingival region, reducing the risk of inflammation of peri-implant soft and hard tissues; not having to remove the cement residues, it is possible to place the margins in more apical portions, improving the aesthetics outcomes of the rehabilitations. It is also known that the retention by means of a screw causes a weakening of the restoration. The retentive force is adequate for fixed rehabilitation even after a high number of insertion–disengagement cycles; in vitro studies have also shown a high bacterial sealing. Implant rehabilitation using preformed components, such as conometric hoods, is helpful for CAD/CAM, so a digital workflow is possible. Several types of prosthesis were presented, all of which demonstrated adequate clinical performance in the follow-up observation. Conclusions: This type of connection seems to be suitable to support fixed implant rehabilitations, but long-term clinical studies are needed to validate this system.

Details

Title
The Conometric Connection for the Implant-Supported Fixed Prosthesis: A Narrative Review
Author
Saturnino Marco Lupi 1   VIAFID ORCID Logo  ; Todaro, Claudia 1 ; De Martis, Dario 1   VIAFID ORCID Logo  ; Blasi, Paola 2 ; Ruggero Rodriguez y Baena 1   VIAFID ORCID Logo  ; Storelli, Stefano 3 

 Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy 
 Private Practice, 16100 Genova, Italy 
 Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy 
First page
458
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
26731592
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2716583238
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.