Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Robotics in otology has been developing in many directions for more than two decades. Current clinical trials focus on more accurate stapes surgery, minimally invasive access to the cochlea and less traumatic insertion of cochlear implant (CI) electrode arrays. In this study we evaluated the use of the RobOtol® (Collin, Bagneux, France) otologic robot to insert CI electrodes into the inner ear with intraoperative ECochG analysis. This prospective, pilot study included two adult patients implanted with Advanced Bionics (Westinghouse PI, CA, USA) cochlear implant, with HiFocus™ Mid-Scala electrode array. The standard surgical approach was used. For both subjects, who had residual hearing in the implanted ear, intraoperative and postoperative ECochG was performed with the AIMTM system. The surgeries were uneventful. A credible ECochG response was obtained after complete electrode insertion in both cases. Preoperative BC thresholds compared to intraoperative estimated ECochG thresholds and 2-day postoperative BC thresholds had similar values at frequencies where all thresholds were measurable. The results of the ECochG performed one month after the surgery showed that in both patients the hearing residues were preserved for the selected frequencies. The RobOtol® surgical robot allows for the correct, safe and gentle insertion of the cochlear implant electrode inside the cochlea. The use of electrocochleography measurements during robotic cochlear implantation offers an additional opportunity to evaluate and modify the electrode array insertion on an ongoing basis, which may contribute to the preservation of residual hearing.

Details

Title
Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography—A Pilot Study
Author
Gawęcki, Wojciech 1   VIAFID ORCID Logo  ; Balcerowiak, Andrzej 2 ; Podlawska, Paulina 2 ; Borowska, Patrycja 2 ; Gibasiewicz, Renata 2 ; Szyfter, Witold 2 ; Wierzbicka, Małgorzata 3 

 Department of Otolaryngology and Laryngological Oncology, Poznan University of Medical Sciences, 60-355 Poznan, Poland; Department of Otolaryngology and Laryngological Oncology, Heliodor Swiecicki Clinical Hospital, 60-355 Poznan, Poland 
 Department of Otolaryngology and Laryngological Oncology, Heliodor Swiecicki Clinical Hospital, 60-355 Poznan, Poland 
 Department of Otolaryngology and Laryngological Oncology, Heliodor Swiecicki Clinical Hospital, 60-355 Poznan, Poland; Institute of Human Genetics, Polish Academy of Sciences, 60-479 Poznan, Poland 
First page
7045
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20770383
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2748540814
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.