Full Text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

In this paper, we propose a multi-channel photonic crystal fiber sensor, which adopts dual-polarization and multiple materials to effectively reduce the mutual interference between channels and enhance the surface plasmon resonance, thus achieving simultaneous detection of a multi-channel with low interference. Four channels are polished around the cylindrical fiber, and then different metal films (gold or silver) and plasmonic materials (titanium dioxide, thallium pentoxide, or graphene) are added to the sensing area of each channel. All channels detect refractive indices in the range of 1.34 to 1.42. The sensing performance of the fiber optic sensor was numerically investigated using the full vector finite element method. After the optimization of structural parameters, the maximum wavelength sensitivity of channel-1, channel-2, channel-3, and channel-4 are 49,800 nm/RIU, 49,000 nm/RIU, 35,900 nm/RIU, and 36,800 nm/RIU, respectively. We have theoretically analyzed the sensor’s capabilities for partial bio-detection and simulated its detection capability with a wavelength sensitivity of 11,500 nm/RIU for normal red blood cells and 12,200 nm/RIU for MCF-7 cancerous cells. Our proposed sensor has a novel design, can detect multiple channels simultaneously, has strong anti-interference capability and high sensitivity, and has good sensing characteristics.

Details

Title
Highly Sensitive Multi-Channel Biosensor for Low-Interference Simultaneous Detection
Author
Su, Jiapeng 1 ; Xiao, Gongli 1   VIAFID ORCID Logo  ; Yang, Hongyan 2   VIAFID ORCID Logo  ; Chen, Jiayu 1 ; Li, Haiou 1 ; Liu, Xingpeng 1 ; Luo, Yunhan 3 ; Li, Jianqing 4   VIAFID ORCID Logo 

 Guangxi Key Laboratory of Precision Navigation Technology and Application, Guilin University of Electronic Technology, Guilin 541004, China 
 Guangxi Key Laboratory of Optoelectronic Information Processing, School of Optoelectronic Engineering, Guilin University of Electronic Technology, Guilin 541004, China 
 College of Science & Engineering, Jinan University, Guangzhou 510632, China 
 Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, Macau University of Science and Technology, Macau 999078, China 
First page
246
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
20794991
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2767275010
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.