1. Introduction
Cryptogenic strokes account for one-third of ischemic strokes, and are defined as strokes of undetermined cause, more than one competing cause, or with incomplete diagnostic investigation [1]. Cardioembolic sources are likely important causes of cryptogenic strokes, and patent foramen ovale (PFO), an incomplete postnatal fusion of the septum primum and secundum, may be a source of cardioembolism [2]. PFO is present in 25% of the general population, and this increases to 40–56% in patients with cryptogenic stroke aged <55 years [3,4]. However, with its high prevalence in the general population, PFO may be incidental in some cases of cryptogenic stroke [5,6]. The American Academy of Neurology guidelines state that it is difficult to determine with certainty whether a patient’s PFO is the cause of stroke, but PFO closure probably reduces stroke risk in selected patients younger than 60 years with embolic-appearing infarction [7]. This is supported by the recently published CLOSE and REDUCE randomized controlled trials (RCT) in patients under 60 years [8,9]. In contrast, earlier RCTs such as the CLOSURE I and PC trial did not show a convincing benefit with PFO closure [10,11]. Furthermore, PFO closure is associated with risks such as atrial fibrillation (AF) and periprocedural complications [8], therefore careful case selection for patients who may benefit from PFO closure is essential.
Characteristics of the PFO, such as right-to-left shunt (RLS), may predispose an individual to ischemic stroke. Theoretically, a greater severity of RLS may increase the risk of paradoxical embolism through the PFO, causing ischemic stroke [12]. In several case-control studies, patients with PFO and acute stroke or transient ischemic attack (TIA) have been reported to have a greater frequency and size of RLS on TEE or transcranial Doppler (TCD) bubble studies [13,14]. The severity of RLS on TCD appeared to correlate with the risk of paradoxical embolism score (RoPE) in one study [15], suggesting it may be predictive of pathogenic PFO in contrast to incidental PFO [16]. However, other studies found no effect of shunt size on recurrent stroke or death [17,18]. Exploratory subgroup analysis of RCTs equally showed mixed and contradictory results [8,9]. Therefore, further evidence is needed to better characterize the impact of shunt size on the risk of ischemic stroke, which may inform the use of shunt size as a criterion for PFO closure in future studies.
In this cohort study of patients with cryptogenic stroke and medically-managed PFO, we aim to investigate the association of shunt size with the risk of recurrent stroke, mortality and newly detected AF, and to identify predictors of recurrent stroke.
2. Methods
We performed a retrospective cohort study at a tertiary stroke center. Between January 2014 and December 2020, all consecutive patients with ischemic stroke or TIA who had undergone a non-invasive TCD bubble study with agitated saline were screened for inclusion [19,20]. Patients were included if they were at least 18 years old and had been diagnosed with cryptogenic stroke (stroke of unknown origin) according to the TOAST classification (one cause, more than one cause, no cause after work-up, and no cause with extensive or complete work-up) [21]. Patients with large artery atherosclerosis, lacunar stroke, cardioembolic causes (such as AF) and other definite causes of stroke were excluded. Cryptogenic stroke patients were excluded if they had a negative TCD bubble study or had undergone a PFO closure (Figure 1).
2.1. Data Collection
We collected information on baseline demographic parameters, clinical parameters, stroke characteristics, investigations, anti-thrombotic regimes, and post-stroke events. The demographics and clinical variables were selected based on the guidelines of the American Heart Association and American Stroke Association for stroke prevention [22]. A thrombophilia screen was conducted as part of the young stroke work-up. This comprised screening for lupus anticoagulants, anti-cardiolipin IgMs, anti-cardiolipin IgGs, anti-B2-glycoprotein 1 IgMs, anti-B2-glycoprotein 1 IgGs, protein C levels, protein S levels, antithrombin-3, factor V Leiden mutation, prothrombin mutation, homocysteine levels, antinuclear antibodies (ANA), perinuclear anti-neutrophil cytoplasmic antibodies (p-ANCA), antineutrophil cytoplasmic antibodies (c-ANCA), and D-dimer [23,24]. A positive thrombophilia screen was defined by a positive result on 2 counts, at least 6 weeks apart, consistent with the laboratory criteria of Sapporo preliminary classification criteria for antiphospholipid syndrome [25].
Echocardiographic parameters from transthoracic echocardiogram (TTE) and transesophageal echocardiogram (TEE) were chosen based on the association with recurrent stroke events in previous literature, such as the left atrium (LA) diameter and left ventricular ejection fraction [18,26,27,28]. We calculated the RoPE score of all the patients included in our study. The RoPE score predicts the likelihood of pathogenic versus incidental PFO in patients with cryptogenic stroke [16,29]. Factors included in the score are a history of hypertension, diabetes, stroke or TIA, current smoking, cortical infarct on imaging, and age.
2.2. TCD Protocol
Non-invasive TCD bubble study with agitated saline was used as an initial screening method for PFO evaluation in patients with ischemic stroke because it has excellent sensitivity and accuracy for PFO detection [30]. The TCD bubble study was performed according to a previously published protocol [31]. Agitated microbubble saline solution was injected through an 18-gauge catheter inserted into the antecubital vein. Continuous TCD monitoring of at least one middle cerebral artery (MCA) was performed for microembolic signals. The Valsalva maneuverer (VM) was performed 4–6 s after the agitated saline injection. Considerable (about 20%) reduction in MCA flow velocities indicates an adequate VM. TCD monitoring is performed for another 16–20 s. Since the RLS grade is affected by the body position during the test, we performed the procedure in supine and sitting positions, and selected the higher value for grading of shunt severity [31].
2.3. Grading of Shunt Sizes
Patients who were detected to have a RLS were further divided into two groups of small and large shunts based on the Spencer logarithmic scale (SLS). There are currently two main systems for grading the size of PFO shunts: the International Consensus Criteria (ICC) or the SLS [32]. In the ICC grading, a shunt is considered present and functional in the presence of at least one air microbubble; whereas in the SLS, the embolic tracts are counted and graded against a 6-level logarithmic scale to further stratify the severity of the shunt. While both grading scales have high accuracy in detecting the presence of a shunt, the SLS has a higher positive predictive value in detecting large and functional RLS compared to the ICC (60% vs. 32%), and a lower false-positive rate [32,33]. Therefore, SLS was used to compare shunt sizes in this study. The Spencer grading of 1 (1–10 microbubbles), 2 (11–30 microbubbles), or 3 (31–100 microbubbles) represents a small shunt, while a Spencer grading of 4 (101–300 microbubbles) or 5 (>300 microbubbles) is a large shunt [32].
2.4. Clinical Outcomes
The primary outcome of this study was recurrent ischemic stroke, which was diagnosed with neuroimaging. The secondary outcomes were all-cause mortality and new AF detection. New AF was diagnosed if it lasted ≥30 s on prolonged cardiac monitoring or entire duration on the 12-lead electrocardiogram in accordance with the European Society of Cardiology guidelines [34]. Patients determined to require further monitoring were recommended for an implantable loop recorder (ILR).
2.5. Statistical Analysis
Data analysis was performed using IBM SPSS version 27 (IBM Corp., Version 27.0. Armonk, NY, USA). Median, first, and third quartiles (Q1, Q3) were reported for non-parametric variables. Means and standard deviations (SD) were reported for continuous variables. Frequencies and percentages were presented for categorical variables. Student’s t-test was used to compare continuous parameters, while Fisher’s exact test or chi-squared test was used to compare categorical parameters.
We compared the baseline characteristics, stroke characteristics, imaging results, and risk of primary and secondary outcomes in patients with large versus small shunts on univariate analysis. To identify variables associated with recurrent stroke in patients with PFO and cryptogenic stroke, univariate analysis comparing patients with recurrent stroke and those without were performed. Significant results were pooled into the multivariate logistic regression model, but significant factors found in literature reviews associated with increased risk of recurrent stroke were also included. A multivariable logistic regression model adjusting for RoPE score and LA diameter > 40 mm was performed for the association of large shunts with recurrent stroke. A time-to-event analysis using the Kaplan–Meier method and log-rank test statistic to compare the risk of recurrent ischemic stroke between small shunts and large shunts was performed. The significance level was set at a p-value of <0.05.
2.6. Statement of Ethics
This study was granted exemption from requiring written informed consent. The study protocol was reviewed and approved by the National Healthcare Group Domain Specific Review Board, approval number 2021/00623.
3. Results
A total of 794 patients with ischemic stroke or TIA and TCD were identified in the study period. The final cohort included 234 patients with cryptogenic stroke or TIA and medically managed PFO, comprising a small shunt group of 135 patients (57.7%) and a large shunt group of 99 patients (42.3%) (Figure 1). The patients had a mean age of 50.5 ± 10.9 years, 31.2% (n = 73) were female, and the median period of follow-up was 348 days (Q1–Q3: 147–1096) following the index ischemic stroke. All patients with TCD-confirmed PFO underwent a TTE. A TEE was performed for 22.6% (n = 53) of patients, and did not detect the presence of a PFO in 26.4% (n = 14) of them. The cohort had a median RoPE score of 6 (Q1–Q3 5–7) and an atrial septal aneurysm was detected in 1.0% (n = 2) of the cohort.
3.1. Large vs. Small Shunt: Baseline Patient Characteristics
There was no significant difference in age, ethnicity, co-morbidities, or presence of thrombophilia between the large and small shunt groups (Table 1). Similarly, stroke characteristics such as NIHSS, bilateral infarcts and infarcts involving the cortex, and TTE features such as PFO visualization, atrial septal aneurysm, LVEF < 50%, and LA diameter > 40 mm were not significantly different. The RoPE score was not found to be associated with shunt size (large shunt: median 5 (Q1–Q3: 4–7), small shunt: median 6 (Q1–Q3: 4–7), p = 0.734). ILR implantation was more frequent in patients with small shunts compared to those with large shunt in our study population, 8.1% (n = 11) vs. 2.0% (n = 2), p = 0.043 (Table 1). Antithrombotic regimes were not found to be associated with shunt size (Table 1).
3.2. Large vs. Small Shunt: Primary and Secondary Outcomes
In total, 4.7% (n = 11) of patients with PFO had a recurrent stroke episode. Recurrent stroke events were higher in patients with large shunts (8.1%, n = 8) compared to those with small shunts (2.2%, n = 3) (p = 0.036) (Table 2). All-cause mortality occurred in 3% (n = 4) of the small shunt group and none of the patients in the large shunt group, which was not statistically significant (p = 0.140) (Table 2). New AF detection was similar between small and large shunt groups (small shunt: 1.5% [n = 2], large shunt: 1.0% [n = 1], p = 0.751).
3.3. Predictors of Recurrent Stroke
Comparing PFO patients with recurrent stroke versus no recurrent stroke, those with recurrent stroke were more likely to have large shunts (recurrent stroke: 72.7% [n = 8], no recurrent stroke: 40.8% [n = 91], p = 0.036) (Table 3). They were also more likely to be Indian and less likely to be Chinese (p = 0.006). All other co-morbidities, stroke characteristics, echocardiographic parameters, and RoPE scores showed no significant difference between patients with recurrent stroke and those without. On Kaplan–Meier analysis, the incidence of recurrent stroke was higher in PFO patients with large compared to small shunts (p = 0.035). The risk of recurrent stroke was highest in the first 250 days after the index event, with 12% occurring within the first 250 days in the large shunt group (Figure 2).
After adjusting for shunt size, RoPE score, and LA diameter > 40 mm, multivariate analysis showed that the presence of a large shunt was an independent predictor of recurrent stroke (aOR 4.09, 95% CI: 1.04–16.0, p = 0.043) (Table 4). The RoPE score and LA diameter > 40 mm was not found to be significantly associated with recurrent stroke episodes, with aORs of 0.869 (95% CI 0.615–1.23, p = 0.428) and 0.667 (95% CI 0.134–3.31, p = 0.620), respectively.
4. Discussion
The main findings of our cohort study of patients with cryptogenic stroke and medically managed PFO were (1) patients with large shunts were significantly more likely to have recurrent stroke than small shunts, (2) the association of large shunts with recurrent stroke was independent of RoPE score and LA size, and (3) baseline characteristics of patients with or without recurrent stroke were similar, except for ethnicity.
The proportion of recurrent ischemic stroke was 4.7% in this cohort study, which increased to 8.1% in patients with large shunt PFOs. The recurrence rates were higher than those observed in medical arms of several RCTs on PFO closure, which reported a yearly incidence of less than 2% per year [35]. However, in most RCTs, such as the CLOSE, REDUCE, RESPECT, CLOSURE I, and PC trials, only patients <60 years were included [8,9,35]. The DEFENSE-PRO trial, which included patients up to 80 years with a mean age of 54 ± 12 years, reported a two-year ischemic stroke rate of 10.5%, similar to our study [36]. As the risk of recurrent stroke increases with age, the higher mean age may contribute to the higher rate of stroke recurrence observed in our study. Our finding that risk of recurrent stroke was higher in patients with large shunt PFOs was consistent with the subgroup analysis of several RCTs on cryptogenic patients aged <60 years. Exploratory analysis in the REDUCE RCT showed a significant reduction in recurrent stroke with PFO closure and antiplatelet therapy versus antiplatelet alone in patients with moderate-to-large shunts, but not those with small shunts [9]. Although the CLOSE RCT did not find any heterogeneity in treatment effect based on shunt size, PFO closure with antiplatelet therapy significantly reduced recurrent stroke compared to antiplatelets alone [8]. Meta-regression of five RCTs showed probable greater benefit of PFO closure in larger shunts, although this was confounded by larger proportion of patients with moderate-to-large shunts compared to antiplatelet agents rather than anticoagulation [37]. The underlying mechanism for this may be that larger shunts facilitate paradoxical embolism through the RLS more easily [12]. PFO may also cause turbulent blood flow and in situ thrombi formation, which may be affected by the PFO morphology and RLS [12]. In contrast, other studies did not show an association of PFO size with stroke risk. A prospective cohort study of 581 cryptogenic stroke by Mas et al. demonstrated that the presence of PFO and size of PFO on TEE bubble study was not associated with increased risk of recurrent stroke [18]. Similarly, Homma et al. on general ischemic stroke patients also found no association of PFO presence and size of PFO on TEE with recurrent stroke or death [17]. TEE, however, is less sensitive than TCD in detecting RLS [38]. Some patients with PFO may have been missed as reported in the studies by Mas et al. and Homma et al. [17,18], and it should be noted that PFO is likely incidental in stroke subtypes such as lacunar or small vessel disease, therefore PFO studies should focus on the cryptogenic stroke population.
The TEE bubble study is considered the gold standard for the diagnosis of PFO due to its better ability to delineate cardiac anatomy [39], and it is often performed after the TCD screening test. A meta-analysis showed that the TEE had a high sensitivity and specificity of 89% and 91%, respectively, for PFO detection when compared to diagnosis by right heart catheterization, surgery, or autopsy [40]. However, in our cohort of patients with TCD-confirmed PFO who underwent TEE, 26.4% of patients did not have TEE-confirmed PFO. Based on previous studies, there is a wide range of TEE diagnostic accuracy, with 7–27% of TEE found to be false negatives and identified as positive on TCD [38]. The higher proportion of false-negatives on TEE suggests that the compliance and quality of TEE in detecting PFO may be variable in our institution, and we postulate that it may be due to the compliance of patients to perform effective Valsalva maneuvers during TEE, particularly when under sedation and with the TEE probe in the esophagus. Compared to TEE, TCD may detect small PFOs missed by TEE and is a more sensitive test in the detection of PFO and RLS with a sensitivity of 95–98% [41,42]. Furthermore, although TCD has high sensitivity and specificity for detecting RLS, it is unable to locate the site of RLS and may include extracardiac shunts such as pulmonary arterial venous malformations not seen on TEE [43]. Hence, this suggests that a combination of the TEE and the TCD is a complementary test and should be considered in the investigation of patients with a high suspicion of paradoxical emboli to achieve higher diagnostic accuracy [44,45]. In our cohort, TEE did not detect the presence of a PFO in 14 out of the 53 patients, which is consistent with previous studies [38]. Based on TCD, we found that large shunts on Spencer grading were predictive of recurrent stroke, corroborating with the benefit of PFO closure seen in exploratory analysis of recent RCTs. A RCT focused on PFO closure in large shunts identified on TCD or TEE is needed to confirm the observed predictive value of shunt size for recurrent PFO-related stroke.
RoPE score was not associated with shunt size or recurrent stroke in our study of medically managed PFO in cryptogenic stroke. The RoPE score, derived from 12 component studies, predicts the likelihood of PFO presence in patients with cryptogenic stroke, and infers from this if the index stroke event is attributable to the PFO [16]. The prevalence of PFO increased from 23% in RoPE score 0–3 to 73% in RoPE score 9 or 10 [16]. An analysis of pooled data from the CLOSURE-I, RESPECT, and PC trials found that the RoPE score anticipated the relative risk reduction of PFO closure versus medical therapy across all levels of the RoPE score (r = 0.95) [46]. However, this study only included trial populations, thus was limited to patients under 60 years-old, and further validation in real-world cohorts for patient selection for PFO closure is needed. The RoPE study also found that patients with a high RoPE score had a lower risk of ischemic stroke despite having a greater attributability to their PFO, and the risk of recurrent stroke remained high even after PFO closure in patients with a low RoPE score in a prospective registry study [47]. This suggests that RoPE may be useful in identifying a subgroup of cryptogenic stroke with likely PFO-related stroke, but as RoPE scores are probabilistic, a low RoPE score cannot rule out a PFO-related stroke with certainty [16,46]. Another limitation of the RoPE score is the exclusion of PFO anatomical features. In our study, baseline characteristics, including those in the RoPE score, were not associated with shunt size or recurrent stroke. Therefore, we propose that shunt size on TCD bubble study may allow further risk stratification for PFO-associated stroke in addition to RoPE score, and increase the accuracy of PFO-related stroke prediction.
LA enlargement is associated with increased risk of recurrent ischemic stroke [48], but the interaction with PFO-associated stroke is unclear. In a retrospective analysis of 1040 patients referred for PFO closure, patients who underwent PFO closure had larger LA diameter than those that were medically managed, which reduced significantly after PFO closure [49]. A LA diameter of ≥43 mm was also predictive of RoPE > 7 independently of RLS, and was also associated with RLS, atrial septum aneurysm, and multiple ischemic lesions on brain MRI, consistent with embolic strokes [49]. LA size measured by LA volume index was higher in patients with PFO and embolic stroke of undetermined source (ESUS), a subgroup of cryptogenic stroke, than controls with PFO in another study [50]. It has been proposed that RLS through a PFO may disrupt blood flow in the LA, leading to LA dysfunction and an AF-like pattern of blood flow, which may lead to clot formation [49]. However, as LA enlargement is an independent risk for recurrent stroke regardless of presence of PFO [48], it is difficult to ascertain the predictive value of LA size on PFO stroke risk. Interestingly, LA enlargement was not associated with recurrent stroke or shunt size in our study, and the discrepancy may be due to the inclusion of medically managed PFO only, resulting in a population with a smaller LA diameter overall. Results of our study would suggest that LA size is a less important factor in PFO-related stroke, but further studies are needed to clarify this complex relationship.
Although the baseline clinical characteristics were similar between patients with large and small shunts, we observed an association between ethnicity and recurrent stroke. Previous studies examining ethnic differences in patients with PFO found that white patients had larger PFO shunts than Black patients, but none researched a multiethnic Asian setting [51]. Our study demonstrated associations between the Indian ethnicity and recurrent stroke but not large shunt size, suggesting that perhaps the strokes were independent of PFO. Other studies found no significant differences in the prevalence of PFO or risk of recurrent stroke [52]. Further studies are needed to characterize any race or ethnic differences in stroke risk associated with PFO and the underlying mechanisms for this. To the best of our knowledge, this is the first study to evaluate PFO shunt size and recurrent stroke risk in a predominantly Asian population.
Strengths and Limitations
Several limitations of this study must be acknowledged. Firstly, this study is a single-center retrospective cohort, and may be susceptible to undiscovered confounding factors, even though we found no significant differences in clinically relevant clinical factors between patients with large and small shunts. Secondly, due to the small sample size of 234 patients, there were low event numbers for several clinical outcomes, particularly mortality and new AF detection, therefore they might be underpowered. It is difficult to assess if the AF may have been the cause of the stroke instead of the incidental stroke finding. In addition, the low number of recurrent stroke events increased the probability of overfitting the multivariable regression model, thus limiting the applicability of the results to other datasets. Thirdly, TCD cannot differentiate between PFO and extracardiac causes of RLS. As TEE is invasive, TEE was performed on only 22.6% (n = 53) patients in our study, and their important PFO anatomical characteristics were not included in our analysis. This low rate of evaluation in our real-world cohort was in part contributed by the unwillingness of patients to consider PFO closure even if TEE had confirmed a significant PFO. TCD is recognized to be a good screening test for PFO; it has good sensitivity, is non-invasive, and can be performed without sedation. Therefore, it is increasingly used as the first-line investigation in many centers [53], including our institution. Fourthly, our study cohort excluded patients with PFO closure. In our institution, as per the AHA/ASA guidelines, patients with larger shunt sizes or high-risk PFO were offered PFO closure. Hence, this may introduce a selection bias as the 16 patients who underwent PFO closure may have had larger shunt sizes, and there is a bias towards the inclusion of patients with smaller shunts in the medical arm. Our study provides further evidence for the association of shunt size on the risk of recurrent stroke in medically managed PFO in a real-world cohort of multiethnic Asian patients.
5. Conclusions
In our cohort of cryptogenic stroke patients with medically managed PFOs, those with large shunts were at a higher risk of recurrent stroke events, independently of RoPE score or LA diameter. RoPE score alone was not significantly associated with recurrent stroke or shunt size. Future studies may consider adopting shunt size on TCD as a feature of high-risk PFO in the case selection for PFO closure in cryptogenic stroke.
Conceptualization, L.L.L.Y., C.-H.S., V.K.S. and B.Y.Q.T.; Formal analysis, A.S.T.L. and C.-H.S.; Data curation, Y.H.T., J.T.F., Y.N.T., Y.Q.L., X.C. and K.H.-X.O.; Writing—original draft, I.C.Z.Y.L.; Writing—review & editing, J.S.Y.H., A.F.-W.H., Y.L., T.T.L., I.K., L.L.L.Y., C.-H.S., V.K.S. and B.Y.Q.T. All authors have read and agreed to the published version of the manuscript.
This study was granted exemption from requiring written informed consent. The study protocol was reviewed and approved by National Healthcare Group Domain Specific Review Board, approval number 2021/00623, and is therefore performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.
As no identifiable data was collected, patient consent was waived, and the study was exempt from review by the National Healthcare Group Domain Specific Review Board.
All data generated or analyzed during this study are included in this article. Further enquiries can be directed to the corresponding author.
The authors declare no conflict of interest.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Figure 1. Flowchart showing patient selection, patient inclusion, and exclusion criteria.
Figure 2. Kaplan–Meier curve comparing cumulative incidence of recurrent stroke between large (Spencer grade 4 or 5) and small (Spencer grade 1, 2, or 3) PFO shunts in patients concomitant cryptogenic stroke.
Characteristics of PFO patients with small and large shunt.
Small Shunt (Spencer Grade 1–3) |
Large Shunt (Spencer Grade 4–5) |
p-Value | |
---|---|---|---|
Patient characteristics | |||
Age (years) of stroke, mean (SD) | 50.2 (12.6) | 51.0 (13.9) | 0.665 |
Female, % (n) | 31.1 (42) | 31.3 (31) | 0.974 |
Race, % (n) | 0.385 | ||
Chinese | 62.2 (84) | 45.5 (45) | |
Malay | 8.9 (12) | 6.1 (6) | |
Indian | 11.1 (15) | 24.2 (24) | |
Others | 17.8 (24) | 24.2 (24) | |
Co-morbidities | |||
Hypertension, % (n) | 36.3 (49) | 28.3 (28) | 0.197 |
Diabetes mellitus, % (n) | 15.6 (21) | 13.1 (13) | 0.603 |
Dyslipidaemia, % (n) | 19.3 (26) | 27.3 (27) | 0.148 |
Ischaemic heart disease, % (n) | 3.7 (5) | 6.1 (6) | 0.400 |
Smoking, % (n) | 7.4 (10) | 14.1 (14) | 0.093 |
Previous stroke/TIA, % (n) | 10.4 (14) | 9.1 (9) | 0.745 |
Chronic kidney disease, % (n) | 1.5 (2) | 1.0 (1) | 0.751 |
Previous venous thromboembolism, % (n) | 1.5 (2) | 1.0 (1) | 0.751 |
Presence of thrombophilia, % (n) | 13.1 (53/61) | 18.5 (10/54) | 0.452 |
Stroke characteristics | |||
NIHSS on arrival, median (IQR) | 6 (1.8–12.5) | 8 (0.0–16.3) | 0.871 |
Tissue plasminogen activator, % (n) | 11.9 (16) | 12.1 (12) | 0.950 |
Endovascular thrombectomy, % (n) | 6.7 (9) | 6.1 (6) | 0.852 |
Bilateral infarcts, % (n) | 10.4 (14) | 12.1 (12) | 0.674 |
Infarct involving cortex, % (n) | 44.4 (60) | 54.5 (54) | 0.127 |
Large vessel occlusion, % (n) | 14.8 (20) | 17.1 (17) | 0.625 |
Antithrombotic regime | |||
Single antiplatelet treatment, % (n) | 60.7 (82) | 52.5 (52) | 0.453 |
Dual antiplatelet treatment, % (n) | 24.4 (33) | 30.3 (30) | 0.289 |
Anticoagulation, % (n) | |||
DOACs | 7.4 (10) | 6.1 (6) | 0.959 |
Vitamin K antagonist | 5.2 (7) | 5.1 (5) | 1.000 |
Overall | 12.6 (17) | 11.1 (11) | 0.986 |
Transthoracic echocardiogram (TTE) | |||
PFO visualized on TTE, % (n) | 3.0 (4) | 5.1 (5) | 0.412 |
Atrial septal aneurysm, % (n) | 0.07 (1) | 0.1 (1) | 0.825 |
LVEF < 50%, % (n) | 3.0 (4) | 7.1 (7) | 0.211 |
Dilated left atrial size ≥ 40 mm, % (n) | 19.3 (26) | 24.2 (24) | 0.420 |
Others | |||
Implantable Loop Recorder implantation, % (n) | 8.1 (11) | 2.0 (2) | 0.043 |
RoPE Score, median (IQR) | 6 (4–7) | 6 (5–7) | 0.734 |
Abbreviations: SD—standard deviation; NIHSS—National Institutes of Health Stroke Scale; IQR—interquartile range; DOACs—dual oral anticoagulant; LVEF—left ventricular ejection fraction; RoPE—risk of paradoxical embolism.
Long-term outcomes of PFO patients with small and large shunt.
Outcomes | Small Shunt (Spencer Grade 1–3) |
Large Shunt (Spencer Grade 4–5) |
p-Value |
---|---|---|---|
No. of days since follow-up, median (IQR) | 301 (143–903) | 400 (146–872) | 0.200 |
Recurrent ischemic stroke, % (n) | 2.2 (3) | 8.1 (8) | 0.036 |
Mortality, % (n) | 3.0 (4) | 0.0 (0) | 0.140 |
New atrial fibrillation detected, % (n) | 1.5 (2) | 1.0 (1) | 0.751 |
Abbreviations: IQR—interquartile range.
Univariate analysis evaluating associations of recurrent ischemic stroke.
Variables | No Recurrent Stroke |
Recurrent Stroke |
p-Value |
---|---|---|---|
Patient characteristics | |||
Age (years) of stroke, mean (SD) | 50.4 (13.3) | 52.3 (11.6) | 0.651 |
Female, % (n) | 31.4 (70) | 27.3 (3) | 0.774 |
Race, % (n) | 0.006 | ||
Chinese | 56.1 (125) | 36.4 (4) | |
Malay | 8.1 (18) | 0.0 (0) | |
Indian | 11.1 (33) | 54.5 (6) | |
Others | 21.1 (47) | 9.1 (1) | |
Large shunt (Spencer grade 4–5), % (n) | 40.8 (91) | 72.7 (8) | 0.036 |
Co-morbidities | |||
Hypertension, % (n) | 32.7 (73) | 36.4 (4) | 0.803 |
Diabetes mellitus, % (n) | 14.3 (32) | 18.2 (2) | 0.725 |
Dyslipidaemia, % (n) | 22.4 (50) | 27.3 (3) | 0.707 |
Ischaemic heart disease, % (n) | 4.9 (11) | 0.0 (0) | 0.451 |
Smoking, % (n) | 9.9 (22) | 18.2 (2) | 0.375 |
Previous stroke/TIA, % (n) | 9.9 (22) | 9.1 (1) | 0.933 |
Chronic kidney disease, % (n) | 1.3 (3) | 0.0 (0) | 1.00 |
Previous venous thromboembolism, % (n) | 1.3 (3) | (0) | 1.00 |
Presence of thrombophilia, % (n) | 16.2 (18/111) | 0.0 (0/4) | 1.00 |
Initial stroke characteristics | |||
Bilateral infarcts, % (n) | 11.2 (25) | 9.1 (1) | 0.827 |
Infarct involving cortex, % (n) | 49.3 (110) | 36.4 (4) | 0.401 |
Large vessel occlusion | 15.8 (33) | 36.4 (4) | 0.056 |
Imaging studies | |||
Patent foramen ovale detected on transthoracic echocardiography, % (n) | 4.6 (9) | 0.0 (0) | 0.467 |
Atrial septal aneurysm, % (n) | 1.0 (2) | 0.0 (0) | 0.748 |
LVEF < 50%, % (n) | 4.0 (9) | 18.2 (2) | 0.088 |
Dilated left atrial size ≥ 40 mm, % (n) | 21.5 (48) | 18.2 (2) | 0.792 |
Others | |||
Implantable Loop Recorder implantation, % (n) | 5.4 (12) | 9.1 (1) | 0.600 |
ROPE score, median (IQR) | 6 (5–7) | 5 (4–7) | 0.448 |
New atrial fibrillation detected | 1.3 (3) | 0.0 (0) | 0.699 |
Abbreviations: SD—standard deviation; NIHSS—National Institutes of Health Stroke Scale; IQR—interquartile range; LVEF—left ventricular ejection fraction; RoPE—risk of paradoxical embolism.
Multivariate logistic regression analysis of factors predicting recurrent stroke.
Variable | Adjusted Odds Ratio (95% CI) | p-Value |
---|---|---|
Large shunt (Spencer grade 4–5) | 4.09 (1.04–16.0) | 0.043 |
RoPE score | 0.869 (0.615–1.23) | 0.428 |
LA diameter > 40 mm | 0.667 (0.134–3.31) | 0.620 |
Abbreviations: CI—confidence Interval; RoPE—risk of paradoxical embolism; LA—left atrial.
References
1. Yaghi, S.; Bernstein, R.A.; Passman, R.; Okin, P.M.; Furie, K.L. Cryptogenic Stroke. Circul. Res.; 2017; 120, pp. 527-540. [DOI: https://dx.doi.org/10.1161/CIRCRESAHA.116.308447] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28154102]
2. Belkin, R.N.; Kisslo, J. Atrial septal aneurysm: Recognition and clinical relevance. Am. Heart J.; 1990; 120, pp. 948-957. [DOI: https://dx.doi.org/10.1016/0002-8703(90)90214-I] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/2220548]
3. Hara, H.; Virmani, R.; Ladich, E.; Mackey-Bojack, S.; Titus, J.; Reisman, M.; Gray, W.; Nakamura, M.; Mooney, M.; Poulose, A. et al. Patent foramen ovale: Current pathology, pathophysiology, and clinical status. J. Am. Coll. Cardiol.; 2005; 46, pp. 1768-1776. [DOI: https://dx.doi.org/10.1016/j.jacc.2005.08.038]
4. Lechat, P.; Mas, J.L.; Lascault, G.; Loron, P.; Theard, M.; Klimczac, M.; Drobinski, G.; Thomas, D.; Grosgogeat, Y. Prevalence of patent foramen ovale in patients with stroke. N. Engl. J. Med.; 1988; 318, pp. 1148-1152. [DOI: https://dx.doi.org/10.1056/NEJM198805053181802]
5. Koutroulou, I.; Tsivgoulis, G.; Tsalikakis, D.; Karacostas, D.; Grigoriadis, N.; Karapanayiotides, T. Epidemiology of Patent Foramen Ovale in General Population and in Stroke Patients: A Narrative Review. Front. Neurol.; 2020; 11, 281. [DOI: https://dx.doi.org/10.3389/fneur.2020.00281]
6. Koutroulou, I.; Tsivgoulis, G.; Karacostas, D.; Ikonomidis, I.; Grigoriadis, N.; Karapanayiotides, T. Prevalence of patent foramen ovale in the Greek population is high and impacts on the interpretation of the risk of paradoxical embolism (RoPE) score. Ther. Adv. Neurol. Disord.; 2020; 13, 1756286420964673. [DOI: https://dx.doi.org/10.1177/1756286420964673] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/33425013]
7. Dia, A.; Cifu, A.S.; Shah, A.P. Management of Patients with a Patent Foramen Ovale With History of Stroke or TIA. JAMA; 2021; 325, pp. 81-82. [DOI: https://dx.doi.org/10.1001/jama.2020.22176] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/33399834]
8. Mas, J.L.; Derumeaux, G.; Guillon, B.; Massardier, E.; Hosseini, H.; Mechtouff, L.; Arquizan, C.; Bejot, Y.; Vuillier, F.; Detante, O. et al. Patent Foramen Ovale Closure or Anticoagulation vs. Antiplatelets after Stroke. N. Engl. J. Med.; 2017; 377, pp. 1011-1021. [DOI: https://dx.doi.org/10.1056/NEJMoa1705915]
9. Sondergaard, L.; Kasner, S.E.; Rhodes, J.F.; Andersen, G.; Iversen, H.K.; Nielsen-Kudsk, J.E.; Settergren, M.; Sjostrand, C.; Roine, R.O.; Hildick-Smith, D. et al. Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke. N. Engl. J. Med.; 2017; 377, pp. 1033-1042. [DOI: https://dx.doi.org/10.1056/NEJMoa1707404] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28902580]
10. Furlan, A.J.; Reisman, M.; Massaro, J.; Mauri, L.; Adams, H.; Albers, G.W.; Felberg, R.; Herrmann, H.; Kar, S.; Landzberg, M. et al. Closure or Medical Therapy for Cryptogenic Stroke with Patent Foramen Ovale. N. Engl. J. Med.; 2012; 366, pp. 991-999. [DOI: https://dx.doi.org/10.1056/NEJMoa1009639]
11. Meier, B.; Kalesan, B.; Mattle, H.P.; Khattab, A.A.; Hildick-Smith, D.; Dudek, D.; Andersen, G.; Ibrahim, R.; Schuler, G.; Walton, A.S. et al. Percutaneous Closure of Patent Foramen Ovale in Cryptogenic Embolism. N. Engl. J. Med.; 2013; 368, pp. 1083-1091. [DOI: https://dx.doi.org/10.1056/NEJMoa1211716]
12. Ioannidis, S.G.; Mitsias, P.D. Patent Foramen Ovale in Cryptogenic Ischemic Stroke: Direct Cause, Risk Factor, or Incidental Finding?. Front. Neurol.; 2020; 11, 567. [DOI: https://dx.doi.org/10.3389/fneur.2020.00567] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32670184]
13. De Castro, S.; Cartoni, D.; Fiorelli, M.; Rasura, M.; Anzini, A.; Zanette, E.M.; Beccia, M.; Colonnese, C.; Fedele, F.; Fieschi, C. et al. Morphological and Functional Characteristics of Patent Foramen Ovale and Their Embolic Implications. Stroke; 2000; 31, pp. 2407-2413. [DOI: https://dx.doi.org/10.1161/01.STR.31.10.2407] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/11022072]
14. Tanzi, A.; Onorato, E.; Casilli, F.; Anzola, G.P. Is the search for right-to-left shunt still worthwhile?. Acta Neurol. Scand.; 2016; 133, pp. 281-288. [DOI: https://dx.doi.org/10.1111/ane.12456]
15. Wessler, B.S.; Kent, D.M.; Thaler, D.E.; Ruthazer, R.; Lutz, J.S.; Serena, J. The RoPE Score and Right-to-Left Shunt Severity by Transcranial Doppler in the CODICIA Study. Cerebrovasc. Dis.; 2015; 40, pp. 52-58. [DOI: https://dx.doi.org/10.1159/000430998] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/26184495]
16. Kent, D.M.; Ruthazer, R.; Weimar, C.; Mas, J.L.; Serena, J.; Homma, S.; Di Angelantonio, E.; Di Tullio, M.R.; Lutz, J.S.; Elkind, M.S. et al. An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke. Neurology; 2013; 81, pp. 619-625. [DOI: https://dx.doi.org/10.1212/WNL.0b013e3182a08d59]
17. Homma, S.; Sacco, R.L.; Di Tullio, M.R.; Sciacca, R.R.; Mohr, J.P. Effect of Medical Treatment in Stroke Patients With Patent Foramen Ovale. Circulation; 2002; 105, pp. 2625-2631. [DOI: https://dx.doi.org/10.1161/01.CIR.0000017498.88393.44]
18. Mas, J.L.; Arquizan, C.; Lamy, C.; Zuber, M.; Cabanes, L.; Derumeaux, G.; Coste, J.; Patent Foramen, O. Atrial Septal Aneurysm Study Group. Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both. N. Engl. J. Med.; 2001; 345, pp. 1740-1746. [DOI: https://dx.doi.org/10.1056/NEJMoa011503]
19. Palazzo, P.; Ingrand, P.; Agius, P.; Belhadj Chaidi, R.; Neau, J.P. Transcranial Doppler to detect right-to-left shunt in cryptogenic acute ischemic stroke. Brain Behav.; 2019; 9, e01091. [DOI: https://dx.doi.org/10.1002/brb3.1091]
20. Komar, M.; Olszowska, M.; Przewlocki, T.; Podolec, J.; Stepniewski, J.; Sobien, B.; Badacz, R.; Kablak-Ziembicka, A.; Tomkiewicz-Pajak, L.; Podolec, P. Transcranial Doppler ultrasonography should it be the first choice for persistent foramen ovale screening?. Cardiovasc. Ultrasound; 2014; 12, 16. [DOI: https://dx.doi.org/10.1186/1476-7120-12-16]
21. Adams, H.P., Jr.; Bendixen, B.H.; Kappelle, L.J.; Biller, J.; Love, B.B.; Gordon, D.L.; Marsh, E.E., 3rd. Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment. Stroke; 1993; 24, pp. 35-41. [DOI: https://dx.doi.org/10.1161/01.STR.24.1.35] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/7678184]
22. Kleindorfer, D.O.; Towfighi, A.; Chaturvedi, S.; Cockroft, K.M.; Gutierrez, J.; Lombardi-Hill, D.; Kamel, H.; Kernan, W.N.; Kittner, S.J.; Leira, E.C. et al. 2021 Guideline for the Prevention of Stroke in Patients With Stroke and Transient Ischemic Attack: A Guideline From the American Heart Association/American Stroke Association. Stroke; 2021; 52, pp. e364-e467. [DOI: https://dx.doi.org/10.1161/STR.0000000000000375] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/34024117]
23. Zhang, J.; Ren, Q.; Song, Y.; He, M.; Zeng, Y.; Liu, Z.; Xu, J. Prognostic role of neutrophil-lymphocyte ratio in patients with acute ischemic stroke. Medicine; 2017; 96, e8624. [DOI: https://dx.doi.org/10.1097/MD.0000000000008624] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29137097]
24. Alakbarzade, V.; Taylor, A.; Scully, M.; Simister, R.; Chandratheva, A. Utility of current thrombophilia screening in young patients with stroke and TIA. Stroke Vasc. Neurol.; 2018; 3, pp. 231-236. [DOI: https://dx.doi.org/10.1136/svn-2018-000169] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30637129]
25. Wilson, W.A.; Gharavi, A.E.; Koike, T.; Lockshin, M.D.; Branch, D.W.; Piette, J.C.; Brey, R.; Derksen, R.; Harris, E.N.; Hughes, G.R. et al. International consensus statement on preliminary classification criteria for definite antiphospholipid syndrome: Report of an international workshop. Arthritis Rheum.; 1999; 42, pp. 1309-1311. [DOI: https://dx.doi.org/10.1002/1529-0131(199907)42:7<1309::AID-ANR1>3.0.CO;2-F]
26. Yaghi, S.; Moon, Y.P.; Mora-McLaughlin, C.; Willey, J.Z.; Cheung, K.; Di Tullio, M.R.; Homma, S.; Kamel, H.; Sacco, R.L.; Elkind, M.S. Left atrial enlargement and stroke recurrence: The Northern Manhattan Stroke Study. Stroke; 2015; 46, pp. 1488-1493. [DOI: https://dx.doi.org/10.1161/STROKEAHA.115.008711] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/25908460]
27. Kamran, S.; Singh, R.; Akhtar, N.; George, P.; Salam, A.; Babu, B.; Own, A.; Hamid, T.; Perkins, J.D. Left Heart Factors in Embolic Stroke of Undetermined Source in a Multiethnic Asian and North African Cohort. J. Am. Heart Assoc.; 2020; 9, e016534. [DOI: https://dx.doi.org/10.1161/JAHA.120.016534]
28. Devereux, R.B.; Alonso, D.R.; Lutas, E.M.; Gottlieb, G.J.; Campo, E.; Sachs, I.; Reichek, N. Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings. Am. J. Cardiol.; 1986; 57, pp. 450-458. [DOI: https://dx.doi.org/10.1016/0002-9149(86)90771-X]
29. Thaler, D.E.; Di Angelantonio, E.; Di Tullio, M.R.; Donovan, J.S.; Griffith, J.; Homma, S.; Jaigobin, C.; Mas, J.L.; Mattle, H.P.; Michel, P. et al. The risk of paradoxical embolism (RoPE) study: Initial description of the completed database. Int. J. Stroke; 2013; 8, pp. 612-619. [DOI: https://dx.doi.org/10.1111/j.1747-4949.2012.00843.x]
30. D’Andrea, A.; Conte, M.; Riegler, L.; Scarafile, R.; Cocchia, R.; Pezzullo, E.; Cavallaro, M.; Di Maio, M.; Natale, F.; Santoro, G. et al. Transcranial Doppler Ultrasound: Incremental Diagnostic Role in Cryptogenic Stroke Part II. J. Cardiovasc. Echogr.; 2016; 26, pp. 71-77. [DOI: https://dx.doi.org/10.4103/2211-4122.187947]
31. Sharma, A.K.; Bathala, L.; Batra, A.; Mehndiratta, M.M.; Sharma, V.K. Transcranial Doppler: Techniques and advanced applications: Part 2. Ann. Indian Acad. Neurol.; 2016; 19, pp. 102-107. [DOI: https://dx.doi.org/10.4103/0972-2327.173407]
32. Lao, A.Y.; Sharma, V.K.; Tsivgoulis, G.; Frey, J.L.; Malkoff, M.D.; Navarro, J.C.; Alexandrov, A.V. Detection of right-to-left shunts: Comparison between the International Consensus and Spencer Logarithmic Scale criteria. J. Neuroimaging; 2008; 18, pp. 402-406. [DOI: https://dx.doi.org/10.1111/j.1552-6569.2007.00218.x]
33. Spencer, M.P.; Moehring, M.A.; Jesurum, J.; Gray, W.A.; Olsen, J.V.; Reisman, M. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J. Neuroimaging; 2004; 14, pp. 342-349. [DOI: https://dx.doi.org/10.1111/j.1552-6569.2004.tb00261.x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/15358955]
34. Calkins, H.; Brugada, J.; Packer, D.L.; Cappato, R.; Chen, S.-A.; Crijns, H.J.G.; Damiano, R.J., Jr.; Davies, D.W.; Haines, D.E.; Haissaguerre, M. et al. HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Heart Rhythm; 2007; 4, pp. 816-861. [DOI: https://dx.doi.org/10.1016/j.hrthm.2007.04.005] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/17556213]
35. Turc, G.; Calvet, D.; Guerin, P.; Sroussi, M.; Chatellier, G.; Mas, J.L.; Investigators, C. Closure, Anticoagulation, or Antiplatelet Therapy for Cryptogenic Stroke With Patent Foramen Ovale: Systematic Review of Randomized Trials, Sequential Meta-Analysis, and New Insights From the CLOSE Study. J. Am. Heart Assoc.; 2018; 7, [DOI: https://dx.doi.org/10.1161/JAHA.117.008356]
36. Lee, P.H.; Song, J.K.; Kim, J.S.; Heo, R.; Lee, S.; Kim, D.H.; Song, J.M.; Kang, D.H.; Kwon, S.U.; Kang, D.W. et al. Cryptogenic Stroke and High-Risk Patent Foramen Ovale: The DEFENSE-PFO Trial. J. Am. Coll. Cardiol.; 2018; 71, pp. 2335-2342. [DOI: https://dx.doi.org/10.1016/j.jacc.2018.02.046]
37. Mir, H.; Siemieniuk, R.A.C.; Ge, L.C.; Foroutan, F.; Fralick, M.; Syed, T.; Lopes, L.C.; Kuijpers, T.; Mas, J.-L.; Vandvik, P.O. et al. Patent foramen ovale closure, antiplatelet therapy or anticoagulation in patients with patent foramen ovale and cryptogenic stroke: A systematic review and network meta-analysis incorporating complementary external evidence. BMJ Open; 2018; 8, e023761. [DOI: https://dx.doi.org/10.1136/bmjopen-2018-023761] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30049703]
38. Stafford, M.B.; Bagley, J.E.; DiGiacinto, D. Comparison of Transthoracic Echocardiography, Transesophageal Echocardiography, and Transcranial Doppler in the Detection of Patent Foramen Ovale as the Etiology for Cryptogenic Stroke. J. Diagn. Med. Sonogr.; 2018; 35, pp. 127-133. [DOI: https://dx.doi.org/10.1177/8756479318816983]
39. Mojadidi, M.K.; Mahmoud, A.N.; Elgendy, I.Y.; Agarwal, N.; Tobis, J.M. Transesophageal Echocardiography for the Detection of Patent Foramen Ovale. J. Am. Soc. Echocardiogr.; 2017; 30, pp. 933-934. [DOI: https://dx.doi.org/10.1016/j.echo.2017.05.006]
40. Mojadidi, M.K.; Bogush, N.; Caceres, J.D.; Msaouel, P.; Tobis, J.M. Diagnostic accuracy of transesophageal echocardiogram for the detection of patent foramen ovale: A meta-analysis. Echocardiography; 2014; 31, pp. 752-758. [DOI: https://dx.doi.org/10.1111/echo.12462]
41. Nygren, A.T.; Jogestrand, T. Detection of patent foramen ovale by transcranial Doppler and carotid duplex ultrasonography: A comparison with transoesophageal echocardiography. Clin. Physiol.; 1998; 18, pp. 327-330. [DOI: https://dx.doi.org/10.1046/j.1365-2281.1998.00106.x]
42. Van, H.; Poommipanit, P.; Shalaby, M.; Gevorgyan, R.; Tseng, C.H.; Tobis, J. Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt. JACC Cardiovasc. Imaging; 2010; 3, pp. 343-348. [DOI: https://dx.doi.org/10.1016/j.jcmg.2009.12.012] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/20394894]
43. Messé, S.R.; Gronseth, G.S.; Kent, D.M.; Kizer, J.R.; Homma, S.; Rosterman, L.; Carroll, J.D.; Ishida, K.; Sangha, N.; Kasner, S.E. Practice advisory update summary: Patent foramen ovale and secondary stroke prevention. Rep. Guidel. Subcomm. Am. Acad. Neurol.; 2020; 94, pp. 876-885. [DOI: https://dx.doi.org/10.1212/WNL.0000000000009443]
44. Katsanos, A.H.; Spence, J.D.; Bogiatzi, C.; Parissis, J.; Giannopoulos, S.; Frogoudaki, A.; Safouris, A.; Voumvourakis, K.; Tsivgoulis, G. Recurrent stroke and patent foramen ovale: A systematic review and meta-analysis. Stroke; 2014; 45, pp. 3352-3359. [DOI: https://dx.doi.org/10.1161/STROKEAHA.114.007109]
45. Souteyrand, G.; Motreff, P.; Lusson, J.R.; Rodriguez, R.; Geoffroy, E.; Dauphin, C.; Boire, J.Y.; Lamaison, D.; Cassagnes, J. Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur. J. Echocardiogr.; 2006; 7, pp. 147-154. [DOI: https://dx.doi.org/10.1016/j.euje.2005.04.007] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/15927538]
46. Kent, D.M.; Saver, J.L.; Ruthazer, R.; Furlan, A.J.; Reisman, M.; Carroll, J.D.; Smalling, R.W.; Juni, P.; Mattle, H.P.; Meier, B. et al. Risk of Paradoxical Embolism (RoPE)-Estimated Attributable Fraction Correlates With the Benefit of Patent Foramen Ovale Closure: An Analysis of 3 Trials. Stroke; 2020; 51, pp. 3119-3123. [DOI: https://dx.doi.org/10.1161/STROKEAHA.120.029350]
47. Morais, L.A.; Sousa, L.d.; Fiarresga, A.; Martins, J.D.; Timóteo, A.T.; Monteiro, A.V.; Soares, C.; Agapito, A.; Pinto, F.; Ferreira, R.C. RoPE Score as a Predictor of Recurrent Ischemic Events After Percutaneous Patent Foramen Ovale Closure. Int. Heart J.; 2018; 59, pp. 1327-1332. [DOI: https://dx.doi.org/10.1536/ihj.17-489] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30305578]
48. Xu, Y.; Zhao, L.; Zhang, L.; Han, Y.; Wang, P.; Yu, S. Left Atrial Enlargement and the Risk of Stroke: A Meta-Analysis of Prospective Cohort Studies. Front. Neurol.; 2020; 11, 26. [DOI: https://dx.doi.org/10.3389/fneur.2020.00026] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32117002]
49. Rigatelli, G.; Zuin, M.; Adami, A.; Aggio, S.; Lanza, D.; d’Elia, K.; Braggion, G.; Russo, M.; Mazza, A.; Roncon, L. Left atrial enlargement as a maker of significant high-risk patent foramen ovale. Int. J. Cardiovasc. Imaging; 2019; 35, pp. 2049-2056. [DOI: https://dx.doi.org/10.1007/s10554-019-01666-x]
50. Lee, M.J.; Park, S.-J.; Yoon, C.H.; Hwang, J.-W.; Ryoo, S.; Kim, S.J.; Kim, G.-M.; Chung, C.-S.; Lee, K.H.; Bang, O.Y. Association of Left Atrial Enlargement with Cortical Infarction in Subjects with Patent Foramen Ovale. J. Stroke; 2016; 18, pp. 304-311. [DOI: https://dx.doi.org/10.5853/jos.2016.00290]
51. Rodriguez, C.J.; Homma, S.; Sacco, R.L.; Di Tullio, M.R.; Sciacca, R.R.; Mohr, J.P.; Investigators, P. Race-ethnic differences in patent foramen ovale, atrial septal aneurysm, and right atrial anatomy among ischemic stroke patients. Stroke; 2003; 34, pp. 2097-2102. [DOI: https://dx.doi.org/10.1161/01.STR.0000085828.67563.42] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/12920255]
52. Di Tullio, M.R.; Sacco, R.L.; Sciacca, R.R.; Jin, Z.; Homma, S. Patent Foramen Ovale and the Risk of Ischemic Stroke in a Multiethnic Population. J. Am. Coll. Cardiol.; 2007; 49, pp. 797-802. [DOI: https://dx.doi.org/10.1016/j.jacc.2006.08.063] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/17306710]
53. D’Andrea, A.; Dweck, M.R.; Holte, E.; Fontes-Carvalho, R.; Cameli, M.; Aboumarie, H.S.; Diener, H.C.; Haugaa, K.H. EACVI survey on the management of patients with patent foramen ovale and cryptogenic stroke. Eur. Heart J.—Cardiovasc. Imaging; 2020; 22, pp. 135-141. [DOI: https://dx.doi.org/10.1093/ehjci/jeaa318] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/33346351]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Introduction: Patent foramen ovale (PFO) is a potential source of cardiac embolism in cryptogenic ischemic stroke, but it may also be incidental. Right-to-left shunt (RLS) size may predict PFO-related stroke, but results have been controversial. In this cohort study of medically-managed PFO patients with cryptogenic stroke, we aimed to investigate the association of shunt size with recurrent stroke, mortality, newly detected atrial fibrillation (AF), and to identify predictors of recurrent stroke. Methods: Patients with cryptogenic stroke who screened positive for a RLS using a transcranial Doppler bubble study were included. Patients who underwent PFO closure were excluded. Subjects were divided into two groups: small (Spencer Grade 1, 2, or 3; n = 135) and large (Spencer Grade 4 or 5; n = 99) shunts. The primary outcome was risk of recurrent stroke, and the secondary outcomes were all-cause mortality and newly detected AF. Results: The study cohort included 234 cryptogenic stroke patients with medically-managed PFO. The mean age was 50.5 years, and 31.2% were female. The median period of follow-up was 348 (IQR 147-1096) days. The rate of recurrent ischemic stroke was higher in patients with large shunts than in those with small shunts (8.1% vs. 2.2%, p = 0.036). Multivariate analyses revealed that a large shunt was significantly associated with an increased risk of recurrent ischemic stroke [aOR 4.09 (95% CI 1.04–16.0), p = 0.043]. Conclusions: In our cohort of cryptogenic stroke patients with medically managed PFOs, those with large shunts were at a higher risk of recurrent stroke events, independently of RoPE score and left atrium diameter.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details






1 Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Level 10, NUHS Tower Block, 1E Kent Ridge Road, Singapore 119228, Singapore
2 Division of Neurology, Department of Medicine, National University Hospital, Singapore 119074, Singapore
3 Department of Emergency Medicine, Singapore General Hospital, Singapore 169608, Singapore; Pre-Hospital & Emergency Research Centre, Duke-National University of Singapore Medical School, Singapore 169857, Singapore; Centre for Population Health Research and Implementation, Singhealth Regional Health System, Singapore 168753, Singapore; Saw Swee Hock School of Public Health, National University of Singapore, Singapore 117549, Singapore
4 Department of Cardiology, National University Heart Centre, Singapore 119074, Singapore
5 Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Level 10, NUHS Tower Block, 1E Kent Ridge Road, Singapore 119228, Singapore; Division of Neurology, Department of Medicine, National University Hospital, Singapore 119074, Singapore
6 Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Level 10, NUHS Tower Block, 1E Kent Ridge Road, Singapore 119228, Singapore; Department of Cardiology, National University Heart Centre, Singapore 119074, Singapore