We thank Cioni et al. for their suggestions and comments [1]. The limitations of a retrospective study using real-world data are ever-present. Moreover, the statistical analysis of these studies presents challenges.
-
We agree that using the most recent adjustments is optimal. We expect that using the updated adjustments will have minimal effects on our findings. Indeed, the difference, by calculating 38 data points, shows an average absolute difference of 0.031 mm (SRKT) and 0.036 mm (Holladay) in axial lengths between the 2011 and 2018 formulas. This suggests that the difference results in clinically non-significant changes. The IOL power results in a change of 1/100 to 1/10 of a Diopter, which is clinically not significant. (Diopters of IOLs are in 0.5 D increments.)
-
We used the Wilcoxon test as a sequential paired method, as shown in Table 3. This is an acceptable alternative analysis. We used the Friedman test for our previous IOL formula statistical analysis. Please see Rosen et al [2]. Note that we used both Wilcoxon and Friedman in this previously published manuscript, but this study involved an intervention—refractive surgery. One recent paper with an intervention (RK) used the Wilcoxon tests for pairwise comparisons with Bonferroni correction after the Friedman tests were significant. This paper compared three formulas [3].
-
A. We did mention the confounding variable, but since this is purely a mathematical calculation, the risk of confounding is minimal compared to the efficiency of using bilateral data in an uncommon phenomenon. The correlation of bilateral data, we believe, is more affected by interventions (for example, drugs and laser treatments where endpoints or outcomes are measured) or disease states rather than diagnostic tests which yield pure numbers [4].
The discussion in this article is about applying GEE and other methods of analyzing correlated data in interventional or outcome studies.
B. While we agree that sample size calculation can be performed, it is not imperative for the real-world mathematical data of IOL formulas analyzed retrospectively for accuracy. For prospective interventional studies, computing sample size is the rule. For rare diseases, this is challenging. High myopia in a predominantly Caucasian population is not too common. A multicenter prospective or retrospective study would be ideal and yield more samples to analyze.
-
We used ULIB because studies in the United States use this platform or database, and furthermore, Hoffer and Savini also recommended it. Thank you for the suggestion; we will look into this European database in our future studies and compare it with ULIB.
-
Thank you for your comment. Contrary to your assertion on the use of Python, this suggestion is indeed by Hoffer and Savini, in the fifth paragraph on the topic of constant optimization.
“Optimization of the unpublished formulas (e.g., Barrett Universal II, EVO, Kane, and Olsen) is not possible using only Excel. Hence, 2 possibilities exist: the first is to contact their authors and ask them to do it for you. The second is using specific computer programming languages able to extract data automatically from any database (e.g., Python Software Foundation, Wilmington, DE), enter them into the formula website, and generate a new database containing the predicted refraction for each eye. Regarding the Holladay 2 formula, which is also unpublished, it is possible to perform optimization using the Holladay IOL Consultant Software & Surgical Outcomes Assessment (
www.hicsoap.com ).”Therefore, on page 3 of our article, we stated,
“For the remaining four unpublished formulas, ULIB IOL constants and biometrics were input into the online calculators via Python (Python Software Foundation, Wilmington, DE, USA) as recommended by Hoffer and Savini.”[5]
We are confident that the statistical tests in this study are adequate. Nevertheless, we will apply some of your suggestions in our future studies when warranted.
Conceptualization, M.M.; methodology, M.M.; formal analysis, K.M.D. and D.P.B.; resources, P.C.H.; data curation, K.M.D., T.S.P. and I.M.D.; writing—original draft preparation, K.M.D., J.L.J., M.M., D.P.B. and T.S.P.; writing—review and editing, K.M.D., J.L.J., M.M. and Y.C.R.; supervision, M.M., Y.C.R. and P.C.H.; project administration, P.C.H.; funding acquisition, M.M. All authors have read and agreed to the published version of the manuscript.
The data presented are available upon request to the corresponding author. The data are not publicly available due to patient privacy.
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
1. Cione, F.; Di Stasi, M.; Sannino, C. Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947. J. Clin. Med.; 2023; 12, 2911. [DOI: https://dx.doi.org/10.3390/jcm12082911]
2. Rosen, D.B.; Heiland, M.B.; Tingey, M.; Liu, H.Y.; Kang, P.; Buckner, B.; Ronquillo, Y.C.; Hoopes, P.C.; Moshirfar, M. Intraocular Lens Calculation after Refractive Surgery: A Long-Term Retrospective Comparison of Eight Formulas. Med. Hypothesis Discov. Innov. Ophthalmol.; 2019; 8, pp. 121-128. [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31598512]
3. Li, M.; Wang, J.-D.; Zhang, J.-S.; Mao, Y.-Y.; Cao, K.; Wan, X.-H. Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. Eur. J. Med. Res.; 2023; 28, pp. 1-7. [DOI: https://dx.doi.org/10.1186/s40001-023-00998-8] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/36631867]
4. E Murdoch, I.; Morris, S.; Cousens, S.N. People and eyes: Statistical approaches in ophthalmology. Br. J. Ophthalmol.; 1998; 82, pp. 971-973. [DOI: https://dx.doi.org/10.1136/bjo.82.8.971] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/9828786]
5. Hoffer, K.J.; Savini, G. Update on Intraocular Lens Power Calculation Study Protocols. Ophthalmology; 2020; 128, pp. e115-e120. [DOI: https://dx.doi.org/10.1016/j.ophtha.2020.07.005] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32653457]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
The limitations of a retrospective study using real-world data are ever-present. [...]the statistical analysis of these studies presents challenges. Regarding the Holladay 2 formula, which is also unpublished, it is possible to perform optimization using the Holladay IOL Consultant Software & Surgical Outcomes Assessment (www.hicsoap.com).” [...]on page 3 of our article, we stated, “For the remaining four unpublished formulas, ULIB IOL constants and biometrics were input into the online calculators via Python (Python Software Foundation, Wilmington, DE, USA) as recommended by Hoffer and Savini.” Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details





1 Hoopes Vision, HDR Research Center, Draper, UT 84020, USA; John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, Salt Lake City, UT 84132, USA; Utah Lions Eye Bank, Murray, UT 84107, USA
2 School of Medicine, University of Utah, Salt Lake City, UT 84132, USA
3 Brigham Young University, Provo, UT 84602, USA
4 College of Osteopathic Medicine, Rocky Vista University, Ivins, UT 80112, USA
5 Hoopes Vision, HDR Research Center, Draper, UT 84020, USA