Content area
Abstract
Heat stress is one of the most common complaints of health care employees who wear isolation gowns to protect themselves from biological agents, particularly during the warmer seasons. This study was conducted in a climatic chamber to determine the influence of airflow within isolated hospital gowns on physiological-perceptual heat strain indices. The experiment was conducted in three trials: regular clothes (CON), an impenetrable gown without air blowing (GO), and a gown with air blowing (GO + FAN) at temperature conditions of 27 °C and 25% relative humidity (RH). During the trial, physiological-perceptual response data were recorded for a half-hour on a treadmill at a speed of km/hr and a slope of 0% activity at 5-min intervals. The ASHRAE Likert scale was used to assess thermal comfort (TC), thermal sensation (TS), and skin wetness sensation (WS). As the results show, there was a significant difference in mean scores for TC and WS in both sexes when working in the CON, GO, and GO + FAN groups (P < 0.001). In women, the mean scores for TS, TC, and WS reduced considerably (P < 0.001) in the GO and GO + FAN in the amount of 10 and 12 CFM (20