Abstract

Safety and efficacy of coronary drug-eluting stents (DES) are often preclinically tested using healthy or minimally diseased swine. These generally show significant fibrotic neointima at follow-up, while in patients, incomplete healing is often observed. The aim of this study was to investigate neointima responses to DES in swine with significant coronary atherosclerosis. Adult familial hypercholesterolemic swine (n = 6) received a high fat diet to develop atherosclerosis. Serial OCT was performed before, directly after, and 28 days after DES implantation (n = 14 stents). Lumen, stent and plaque area, uncovered struts, neointima thickness and neointima type were analyzed for each frame and averaged per stent. Histology was performed to show differences in coronary atherosclerosis. A range of plaque size and severity was found, from healthy segments to lipid-rich plaques. Accordingly, neointima responses ranged from uncovered struts, to minimal neointima, to fibrotic neointima. Lower plaque burden resulted in a fibrotic neointima at follow-up, reminiscent of minimally diseased swine coronary models. In contrast, higher plaque burden resulted in minimal neointima and more uncovered struts at follow-up, similarly to patients’ responses. The presence of lipid-rich plaques resulted in more uncovered struts, which underscores the importance of advanced disease when performing safety and efficacy testing of DES.

Details

Title
Plaque burden is associated with minimal intimal coverage following drug-eluting stent implantation in an adult familial hypercholesterolemia swine model
Author
Razzi, Francesca 1 ; Dijkstra, Jouke 2 ; Hoogendoorn, Ayla 1 ; Witberg, Karen 1 ; Ligthart, Jurgen 1 ; Duncker, Dirk J. 1 ; van Esch, Jan 3 ; Wentzel, Jolanda J. 1 ; van Steijn, Volkert 3 ; van Soest, Gijs 1 ; Regar, Evelyn 4 ; van Beusekom, Heleen M. M. 5 

 Erasmus MC, Department of Cardiology, Rotterdam, The Netherlands (GRID:grid.5645.2) (ISNI:000000040459992X) 
 Leiden University Medical Center, Leiden, The Netherlands (GRID:grid.10419.3d) (ISNI:0000000089452978) 
 Delft University of Technology, Department of Chemical Engineering, Delft, The Netherlands (GRID:grid.5292.c) (ISNI:0000 0001 2097 4740) 
 University Hospital Ludwig-Maximilians University, Munich, Germany (GRID:grid.5252.0) (ISNI:0000 0004 1936 973X) 
 Erasmus MC, Department of Cardiology, Rotterdam, The Netherlands (GRID:grid.5645.2) (ISNI:000000040459992X); Erasmus MC, University Medical Center, Department of Cardiology, Rotterdam, The Netherlands (GRID:grid.5645.2) (ISNI:000000040459992X) 
Pages
10683
Publication year
2023
Publication date
2023
Publisher
Nature Publishing Group
e-ISSN
20452322
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2831896944
Copyright
© The Author(s) 2023. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.