Abstract
Background
Recent data demonstrated that personalized dosimetry-based selective internal radiotherapy (SIRT) is associated with better outcome for unresectable hepatocellular carcinoma (HCC).
Aim
We aim to evaluate the contribution of personalized predictive dosimetry (performed with Simplicity90® software) in our population of HCC patients by comparing them to our historical cohort whose activity was determined by standard dosimetry.
Methods
This is a retrospective, single-center study conducted between February 2016 and December 2020 that included patients with HCC who received SIRT after simulation based on either standard dosimetry (group A) or, as of December 2017, on personalized dosimetry (group B). Primary endpoints were best overall response (BOR) and objective response rate (ORR) evaluated by mRECIST at 3 months. Safety and toxicity profiles were evaluated at 1- and 3-months post-treatment. For group A we compared the activity to be administered determined a posteriori using Simplicit90Y® and the activity actually administered determined by the standard approach.
Results
Between February 2016 and December 2020, 66 patients received 69 simulations leading to 40 treatments. The median follow-up time was equal for both groups, 21 months (range 3–55) in group A and 21 months (range 4–39) in group B. The per patient analysis revealed a significant benefit of personalized predictive dosimetry in terms of better overall response at 3 months (80% vs. 33.3%, p = 0.007) and at 6 months (77.8% vs. 22.2%, p = 0.06). This trend was found in the analysis by nodule with a response rate according to mRECIST of 87.5% for personalized dosimetry versus 68.4% for standard dosimetry at 3 months, p = 0.24. Only one grade 3 biological toxicity (hyperbilirubinemia) was noted in group A. The comparison between the administered activity and the recommended activity recalculated a posteriori using Simplicit90Y® showed that the vast majority of patients who progressed (83.33%) received less activity than that recommended by the personalized approach or an inadequate distribution of the administered activity.
Conclusions
Our study aligns to recent literature and confirms that the use of personalized dosimetry allows a better selection of HCC patients who can benefit from SIRT, and consequently, improves the effectiveness of this treatment.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
; Collette, Benoît 2 ; Tancredi, Illario 3 ; Vouche, Michael 3 ; Pezzullo, Martina 3 ; Bouziotis, Jason 4 ; Moreno-Reyes, Rodrigo 2 ; Trotta, Nicola 2 ; Levillain, Hugo 2 ; Van Laethem, Jean Luc 1 ; Verset, Gontran 1 1 Université Libre de Bruxelles (ULB), Department of Gastroenterology, Hepatopancreatology and Digestive Oncology, Hôpital Erasme/Bordet Institute-Hôpital Universitaire de Bruxelles, Brussels, Belgium (GRID:grid.4989.c) (ISNI:0000 0001 2348 0746)
2 Université Libre de Bruxelles (ULB), Department of Nuclear Medicine, Hôpital Erasme/Bordet Institute-Hôpital Universitaire de Bruxelles, Brussels, Belgium (GRID:grid.4989.c) (ISNI:0000 0001 2348 0746)
3 Université Libre de Bruxelles (ULB), Department of Radiology, Hôpital Erasme/Bordet Institute-Hôpital Universitaire de Bruxelles, Brussels, Belgium (GRID:grid.4989.c) (ISNI:0000 0001 2348 0746)
4 Université Libre de Bruxelles (ULB), Department of Biomedical Research, Hôpital Erasme/Bordet Institute-Hôpital Universitaire de Bruxelles, Brussels, Belgium (GRID:grid.4989.c) (ISNI:0000 0001 2348 0746)