Abstract
Herein, we have constructed a magnetic graphene field-effect transistor biosensor (MGFETs) for highly sensitive detection of cardiac troponin I (CTNI). Graphene films transferred to ITO conductive glass as conductive channels. CTNI aptamer was immobilized onto the graphene film via 1-pyrene-butanoic acid succinimidyl ester (PBASE) to capture CTNI. Magnetic nanobeads (MBs) modified with CTNI antibody were added to the reaction chamber to form an aptamer/CTNI/antibody/magnetic nanobeads sandwich-type complex. We found that the magnetic force exerted on the complex leads to an impedance change of the graphene film. The reason for this result is that the magnetic field exerts an influence on the MBs, causing CTNI aptamer strand to bend, resulting in a change in the distance between the double conductive layers of the graphene film surface and the test solution. With periodic sampling integration, different concentrations of CTNI can be detected with high sensitivity. Due to the stringent recognition capability and high affinity between the CTNI aptamer and CTNI, MGFETs have the potential to detect various types of proteins. Furthermore, MGFETs also have the potential to be utilized for the detection of DNA or specific cells in the future.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Shandong Province Key Laboratory of Medical Physics and Image Processing Technology, School of Physics and Electronics, Shandong Normal University, 250358, Jinan, People’s Republic of China (ROR: https://ror.org/01wy3h363) (GRID: grid.410585.d) (ISNI: 0000 0001 0495 1805)