Abstract
Background
Automated surveillance methods that re-use electronic health record data are considered an attractive alternative to traditional manual surveillance. However, surveillance algorithms need to be thoroughly validated before being implemented in a clinical setting. With semi-automated surveillance patients are classified as low or high probability of having developed infection, and only high probability patients subsequently undergo manual record review. The aim of this study was to externally validate two existing semi-automated surveillance algorithms for deep SSI after colorectal surgery, developed on Spanish and Dutch data, in a Swedish setting.
Methods
The algorithms were validated in 225 randomly selected surgeries from Karolinska University Hospital from the period January 1, 2015 until August 31, 2020. Both algorithms were based on (re)admission and discharge data, mortality, reoperations, radiology orders, and antibiotic prescriptions, while one additionally used microbiology cultures. SSI was based on ECDC definitions. Sensitivity, specificity, positive predictive value, negative predictive value, and workload reduction were assessed compared to manual surveillance.
Results
Both algorithms performed well, yet the algorithm not relying on microbiological culture data had highest sensitivity (97.6, 95%CI: 87.4–99.6), which was comparable to previously published results. The latter algorithm aligned best with clinical practice and would lead to 57% records less to review.
Conclusions
The results highlight the importance of thorough validation before implementation in other clinical settings than in which algorithms were originally developed: the algorithm excluding microbiology cultures had highest sensitivity in this new setting and has the potential to support large-scale semi-automated surveillance of SSI after colorectal surgery.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer