1. Introduction
Restoring endodontically treated teeth has long been a biological and biomechanical challenge [1]. Factors affecting the outcome of coronal restoration have been investigated extensively. The extent of coronal tissue loss, the use of a root anchorage, and the design of the peripheral limit, particularly with or without a circumferential ferrule, are still topics of discussion [2]. Until recently, the dehydration of treated teeth [3,4] and/or additional loss of tissues due to the canal preparation [5] were hypotheses used to explain long-term failures due to root fractures. During the last decade, the evolution of CAD/CAM procedures and pulp regeneration therapeutics has led to new solutions for the restoration of endodontically treated teeth. It has already been reported that CAD/CAM endocrown restorations could be performed on posterior teeth with root canal treatment (Rct), a solution that has been assessed as having a low risk of failure after several years [6,7,8]. It was also reported that CAD/CAM endocrowns could be safely recommended to restore severely damaged permanent molars with pulpitis treated with full pulpotomy (FP) [9]. The combination of an endocrown and full pulpotomy has the advantage of preserving the residual biological potential of the pulp and ensuring an endo-prosthetic continuum with the objective of long-term success. Before carrying out further clinical trials, in vitro assessments are needed to base clinical procedures on evidence. Three points should be taken into consideration: (I) It is unknown whether the mechanical behavior of endocrowns differs between teeth being treated with full pulpotomy or root canal treatment. (II) The design of the coronal preparation has already been investigated, but the results are still being debated [2]. In particular, additional experiments comparing coronal preparation with or without a peripheral ferrule are needed. (III) Contradictory results have been reported on the relative resistance of both composite and ceramic materials used for endocrown milling [10].
This study has a supplementary goal that concerns the interest of using 3D-printed resin simulators rather than human teeth for in vitro experiments. Collecting sound human molars with the same anatomical characteristics [11] for in vitro studies as well as for educational issues is difficult. Moreover, the first and second molars collected for studies are often damaged before being extracted due to the carious process or restorations, and the third molars are often cut during extraction to preserve most of the bone. The dental community would certainly benefit from using validated simulators instead of natural human teeth. Dental simulators have been created with different materials [12,13]. Three-dimensional-printed resin simulators were first developed for pedagogical purposes [14], and it was reported that their use had positive effects on students’ self-confidence [15]. Three-dimensional-printed simulators have not yet been used in comparison with human teeth during experimental mechanical tests.
This in vitro study was primarily designed to compare the fracture resistance of human mandibular molars, treated either with full pulpotomy or with root canal treatment and then prepared according to two designs of coronal preparation to be finally restored with an endocrown milled using either a composite or ceramic block. The second goal was to assess whether 3D-printed resin simulators could be a reliable alternative for human teeth during in vitro strength tests.
2. Materials and Methods
2.1. Samples and Study Design
Human teeth (HT): Authorizations for using natural human teeth were obtained from patients treated in the dental department of the University Hospital of Clermont-Ferrand, France. One hundred and ten human mandibular molars, extracted for orthodontic or periodontal reasons, without caries, enamel cracks, or anatomical defects, were collected and kept in sodium chloride (NaCl 0.9%) solution. The teeth were randomly divided into eleven groups according to endodontic treatments, types of coronal preparation, and milling materials for endocrowns (Figure 1): 10 teeth were kept sound without any preparation; 50 teeth received root canal treatment; and 50 other teeth received full pulpotomy. In each subgroup of 50 teeth, 10 teeth were left without restoration after endodontic treatment (Rct or FP). The other 40 were divided into 4 groups of 10 according to the material used and the type of coronal preparation.
The number of samples needed was estimated from a preliminary pilot study analyzing the fracture strength resistance between natural root-canal-treated teeth restored with flat margin endocrowns vs. those restored with 2 mm circumferential ferrule endocrowns. The mean strength value was higher for teeth restored with flat margin endocrowns (1630 ± 320.3 N versus 1076 ± 328.1 Newtons, respectively) (SD = 406.3). Calculations were based on this difference for a continuous criterion with independent values and indicated the need for at least 10 samples for each group (α = 5%; β = 15%; epiR package 0.9–30).
The procedures for endodontic treatment and coronal preparation are detailed in Table 1.
Resin simulators (RSs): One first lower left molar was created using 3D modeling using Blender software (v3.2.1, Blender Foundation) with one mesial root with two independent canals and one distal root with one central canal. Four versions of this model were then created, differing in the presence or absence of an endodontic access cavity and the type of crown preparation (Figure 2): 10 duplicates of the model without coronal preparation or an access cavity (Figure 2a), 20 duplicates with an access cavity (Figure 2b), 40 duplicates with flat peripherical coronal preparation (Figure 2c), and 40 duplicates with a 2 mm peripherical ferrule (Figure 2d). The simulators were manufactured using a STRATASYS™ Objet30 Prime 3D printer (Polyjet technology, Eden Pairie, MN, USA) with RGD525 resin, which provides the best mechanical characteristics. The simulators were built using multiple 28 µm photo-polymerized layers from root to crown. The surface finish was defined as glossy, which improves strength, and no post-curing protocol was used.
2.2. Study Criteria
The main study criterion was the fracture strength resistance given in Newtons. The secondary criterion was the type of fracture [16]: (i) a catastrophic fracture was below the cementoenamel junction and extended up to the root; (ii) a favorable fracture was one that was above the cementoenamel junction. The explicative factors were (i) the type of endodontic treatment, RCT or FP; (ii) the type of preparation for the endocrowns, with a 2 mm circumferential ferrule (Fer) or flat margin (Fla); and (iii) the material of the endocrowns, ceramic (IPS e.max CAD®, Ce, Ivoclar-Vivadent, Schaan, Liechenstein) or composite (Cerasmart®, Co., GC, Tokyo, Japan).
2.3. Loading Test
All 110 human teeth and 110 3D-printed resin simulators were embedded individually in self-cured epoxy resin (U-Pol Plastikit, Wellingborough, UK). Each sample was placed in the fixture of a universal testing machine (Zwick Roell UTS 20K, Ars-Laquenexy, France). The compression tests were carried out with a 5 mm diameter stainless steel sphere placed on the middle of the occlusal face and according to a 45° angle to the long axis. The samples were loaded at a rate of 0.5 mm/min until fracture. A measurement was made automatically every 0.1 s. A 30% reduction in the load strength resulted in automatically stopping the recording.
2.4. Statistical Analysis
The data were statistically analyzed with SPSS software (28.0.1.1, IBM Corp, USA). The distribution of each group was tested using a Shapiro–Wilk test. In the case where all groups had a normal distribution, the groups were compared using a one-way analysis of variance (ANOVA) with a Student–Newman–Keuls post hoc test. If one group showed an abnormal distribution, the samples were compared using a Kruskal–Wallis test. The distribution of the fracture type was compared with a chi-square test. The human teeth and resin simulator strength values were compared for each condition with a Mann–Whitney test. The equality of variance between the RS groups and HT groups was compared with Levene’s test.
3. Results
3.1. Strength Test Values
The mean values of the maximum forces leading to the fracture of the sample groups are presented in Figure 3 and Figure 4.
The Shapiro–Wilk test validated a normal distribution for all the groups of human teeth but did not validate a normal distribution for the resin simulators. An analysis of variance (ANOVA) was performed for the human teeth groups and then a Kruskal–Wallis test was performed to compare the results for the groups of human teeth and resin simulators (Table 2).
For the human teeth groups, the ANOVA test separated two homogeneous groups, the negative controls grouping the root-canal-treated teeth or full-pulpotomy-treated teeth without coronal restoration (Rct− and FP−) and all the other samples, i.e., the untreated sound teeth (positive control, C+) and the treated and restored teeth. The negative control groups showed significantly lower resistance than the untreated sound teeth or the teeth treated with coronal restoration.
The results of the Kruskal–Wallis test were different for the resin simulators in contrast with natural human teeth. The resin simulators with ceramic restorations and either endodontic treatment (Rct or FP) had greater resistance than the simulators without treatment and those without restoration. Untreated simulators (positive control, C+) had the same resistance as simulators with endodontic treatment without restoration (negative controls, Rct− and FP−). Simulators with composite restorations had the same fracture resistance as simulators without restoration except for those with composite restorations with circumferential ferrule preparation and in the case of Rct.
3.2. Fracture Type
Amongst the 110 human teeth, 36 had favorable fractures. The distribution of the type of fracture depending on the different groups is visible in Table 3.
The type of fracture was always less favorable for treated teeth than for sound teeth. The type of fracture in all the groups of treated teeth was the same as that in the negative control groups except for that in the group of teeth treated with pulpotomy and flat margin ceramic endocrowns (FP-Fla-Ce), which was always catastrophic.
Amongst the 110 resin simulators, 3 had favorable fractures. The distribution of the type of fracture depending on the different groups is visible in Table 4.
The type of fracture was catastrophic for resin simulators regardless of the material, the preparation, or the endodontic treatment.
4. Discussion
To our knowledge, this is the first work assessing the in vitro mechanical behavior of molars treated either with pulpotomy or root canal treatment and the first one that has demonstrated that the mechanical behavior of resin simulators does not reproduce that of human teeth. For human teeth, pulpotomy and root canal treatment had similar impacts on the strength resistance and the type of tooth fracture, regardless of the composition of the milling material and the type of peripheral limit. These results suggest that indications to use endocrown restoration should not be based on the mechanical resistance of endodontically treated teeth. Other parameters such as the pulpal diagnosis, the risk factors for occlusal and proximal wear, and the ferrule effect should be considered. Finally, the interest of the ferrule effect should be re-examined, at least with the objective of improving the mechanical resistance of endocrowns.
Pulpal diagnosis should be performed first to indicate either pulpotomy or root canal treatment. Full pulpotomy has been indicated for the treatment of reversible pulpitis associated with a carious lesion or a healthy pulp after traumatic pulp exposure in primary teeth and immature permanent teeth [17]. In mature permanent teeth, it was used as an emergency procedure before root canal treatment in teeth with irreversible pulpitis [18]. During the last decade, a better understanding of pulpal biology and the development of bioactive materials has led to reinvestigating pulpotomy as a definitive treatment for vital mature permanent teeth needing root canal treatment due to inflammatory conditions. Pulpotomy and root canal treatment demonstrate comparable and effective postoperative pain relief since the pulpotomy procedure provides a significant gain in time compared with root canal treatment [19]. Pulpal necrosis or the infection of one or more canals are contraindications for performing a pulpotomy. Many recent studies have shown that the quality of coronal restoration, its sealing, and the delay before its implementation are key factors for the success of a pulpotomy [20,21,22]. A better tooth survival rate is observed if the restoration is carried out within two days of pulpal exposure, thus emphasizing the need to limit the number of treatment sessions and the time between them [23]. Thus, when pulpotomy is biologically indicated and endocrown restoration can be performed within a short time, this treatment can be offered to patients without loss of chance from a mechanical point of view for the tooth compared with root canal treatment. Moreover, patients spend less time in the chair, and the iatrogenic risks inherent to root canal treatment (instrumental fracture, stripping, etc.) can be avoided. This is particularly true in molars where iatrogenic perforations are more frequent, especially if they have significant curvatures [24]. Today, the use of posts is limited because it does not increase tooth resistance and is indicated only in case of high loss of dental tissue to increase the retention of restorations [25]. Furthermore, the use of posts in the posterior sector is considerably reduced, and an endocrown [26] or overlay with a composite build-up [27] is proposed for a severely damaged tooth. In this respect, the indication for pulpotomy treatment is no longer limited.
The use of the WaveOne Primary file for the endodontic treatments performed in this study is justified by its ease of use (single instrument) and the lower risk of instrumental fracture and root microcracks via its reciprocal movement. Studies have shown that reciprocating motion induces lower tensile and compressive stress in the flexed region of the instrument, thus providing greater fatigue resistance compared with continuous rotative movement [28,29]. High-taper instruments, such as the WaveOne Primary (25/0.08), can contribute to deeper infected-tissue removal, achieving the appropriate irrigant penetration level [30], and a recent systematic review concluded that it is not clear whether a difference in taper angle can determine differences in root fracture resistance; therefore, it is not possible to provide clinical recommendations regarding the use of endodontic instruments with a high (≥6%) or a low (<6%) taper [31].
This study showed that the resistance strength of the restored teeth was similar when comparing composite and ceramic endocrowns. This point has been discussed in previous studies and remains a subject of interest. Finite element studies have shown less stress generated for ceramic [32,33,34,35] and composite [36,37,38] endocrowns. In contrast, in vitro studies have reported better resistance with less favorable fractures for ceramic endocrowns [16,39] than for composite endocrowns [16,40,41,42]. Moreover, indications for the use of ceramic rather than composite endocrowns should be considered with regard to the high rate of composite wear [43,44]. Clinicians are faced with a conflictual choice between ceramic and composite endocrowns. On the one hand, a composite material leads to fractures of the endocrown, allowing the tooth to be re-restored. On the other hand, ceramic material offers a sustainable solution to restore proximal and occlusal contacts. An original two-piece combination of one build-up made of a resin composite in the pulp chamber and a ceramic overlay was proposed. It was demonstrated that the mechanical resistance of the two-piece restorations was similar to that of ceramic endocrowns [45]. For teeth treated with pulpotomy, a layer of material used for pulp capping is always present in the chamber volume and more or less fills all the pulp volume, as performed in a build-up. In such situations, the question is whether the pulp-capping material could have sufficient biomechanical qualities to be considered as a core build-up. Several studies have reported the use of mineral trioxide aggregate (MTA) material, calcium-enriched mixture (CEM), and Biodentine® for pulp capping after full pulpotomy. It was demonstrated that Biodentine® has a higher resistance value to compressive strength than CEM or MTA, which reaches the resistance of dentine [46] but remains lower than that of a composite [47]. In order to replace a composite core with a Biodentine® core, it is necessary to verify whether it is possible to bond a ceramic endocrown on Biodentine®. It was shown that regarding resistance to shear, the bond strength is lower for the Biodentine®/ceramic interface than for the composite/ceramic interface [48]. To improve the resistance of the Biodentine®/ceramic interface, some authors suggest applying a composite layer between the Emax overlay and the Biodentine® core. The bonding system with 10-MDP seems to give a better interface quality than other bonding systems [49]. Further studies are necessary to investigate the quality of the interface between both materials used for endocrowns and a core build-up and, particularly, to test whether the quality of the interface also depends on the type of ceramic used for endocrowns.
The present study showed that there is no ferrule effect in the case of preparations for endocrowns. However, when the teeth were prepared for full crowns, the ferrule effect was considered an important criterion for survival prognosis. This effect was recently discussed in a systematic review [2]. In vitro studies showed a protective effect of the ferrule in relation to the fracture [50,51,52], and in vivo studies showed a very high survival rate in which failures were due to the debonding of the endocrown and not to the fracture [7,8]. The advantages of preparations with a ferrule were related to the height of the ferrule and the bevel of the margin. A recent finite element study proposed to perform a 20° bevel, which would produce the same effect as a conventional ferrule [37]. In the present study, a 2 mm ferrule was chosen because it was reported in the literature that this value was necessary to protect teeth with full crowns from catastrophic failure. Although one study showed that a height of 1 mm was a better value for an endocrown restoration [51], another study showed a contradictory result, with better protection with a 2 mm ferrule than with a 1 mm ferrule [52]. In the present study, the presence of a ferrule had no effect on the fracture resistance, although the absolute resistance value was recorded for the group with a ceramic endocrown with a ferrule preparation (group Rct-Fer-Ce). Including a smaller number of groups with a focus on teeth treated with pulpotomy might increase the possibility of making these differences significant.
This study demonstrated that 3D-printed resin simulators could not be used in place of human teeth for in vitro resistance studies. However, the variance of the mean strength value was lower for 3D-printed simulators than for human teeth. This suggests that the modeling of resin simulators allows controlling the variability of natural human teeth size and shape. Thus, the modeling of simulators could be interesting in experimental studies in which new materials with mechanical behaviors close to those of enamel and dentin are used in printers.
One limitation of this study is the absence of artificial aging. Given the large number of conditions tested in this study, the addition of thermocycling would have doubled the number of teeth needed. However, collecting teeth is a complex part of this type of study in a health care system that encourages the conservation of teeth and where, in the concept of minimally invasive surgery, the extraction of complete teeth is rare. Another limitation is that this study was conducted on mandibular molars and cannot be generalized for other posterior teeth, particularly the maxillary premolar, which is a tooth at high risk of fracture. For certain in vitro studies, for example, the use of a fiber post increased the fracture resistance of maxillary premolars [53], which is not the case for the other posterior teeth [25]. A finite element study suggested that endocrowns could be the best restoration for maxillary premolars [54]. Further studies could be designed to investigate the effect of the type of teeth on endocrown fracture resistance. Finally, one can question the relevance of comparing the in vitro fracture resistance of natural teeth treated either with root canal treatment or full pulpotomy. The starting hypothesis was the fact that, in vivo, dentin moisture decreases Young’s modulus of radicular dentine [55] and, in turn, acts as a protective factor against fracture. However, in in vitro studies, not all avulsed teeth contained pulp tissue, and one cannot expect any difference in fracture resistance between groups with root canal treatment or pulpotomy. In vivo long-term follow-up studies would therefore be necessary to estimate the impact of the presence of vital pulp tissue on tooth strength. In such studies, other parameters could act as confounding factors, as the extent of the tissue damage would be greater in teeth with root canal treatment than in teeth with pulpotomy.
5. Conclusions
Pulpotomy and root canal treatment had similar impacts on the strength resistance and the type of fracture of teeth restored with endocrowns, regardless of the composition of the milling material and the type of peripheral limit. Within the limits of this study, this work suggested that endocrowns can, therefore, be chosen as a restoration for teeth treated with pulpotomy. This study provides new perspectives for treating teeth with inflammatory pulpal disease in one single chairside session in combination with the use of CAD/CAM processing. Three-dimensional-printed resin simulators should not be used in place of human teeth for in vitro resistance studies because their behavior in fracture resistance tests (strength test values and type of fracture) is not comparable to that of human teeth.
Conceptualization, M.-L.M.-S., N.D. and M.H.; methodology, M.-L.M.-S., A.G., N.D., O.F. and M.H.; formal analysis, N.D., M.H. and E.N.; investigation, M.-L.M.-S., N.D. and A.G.; writing—original draft preparation, N.D. and M.-L.M.-S.; writing—review and editing, M.H. and E.N.; visualization, O.F.; supervision, N.D. All authors have read and agreed to the published version of the manuscript.
Human teeth (HT): Authorizations for using natural human teeth were obtained from patients treated in the dental department of the University Hospital of Clermont-Ferrand, France.
Informed consent was obtained from all subjects involved in the study.
Data are available upon request.
The authors would like to thank Jean-Luc Veyrune and Thierry Orliaguet for their financial and administrative support, respectively. The authors would also thank Caroline Eschevins for her technical assistance. The authors would like to thank Geoffrey Lefebvre, Annaëlle Saintilan, Cyril Claise, and Charles Kolbach for their help in the data collection. This study was supported by GC (Tokyo, Japan), who donated the materials used in this study.
The authors declare no conflict of interest.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Figure 1. Study design. C+: sound teeth (positive control); FP−: teeth with FP and no restoration (negative control for FP-treated teeth); FP-Fla-Ce: FP-treated teeth restored with a flat margin ceramic endocrown; FP-Fla-Co: FP-treated teeth restored with a flat margin composite endocrown; FP-Fer-Ce: FP-treated teeth restored with a ceramic endocrown with 2 mm circumferential ferrule; FP-Fer-Co: FP-treated teeth restored with a resin composite endocrown with a 2 mm circumferential ferrule; Rct-Fla-Ce: root-canal-treated teeth restored with a ceramic endocrown with a flat margin; Rct-Fla-Co: root-canal-treated teeth restored with a resin composite endocrown with flat margin; Rct-Fer-Ce: root-canal-treated teeth restored with a ceramic endocrown with a 2 mm circumferential ferrule; Rct-Fer-Co: root-canal-treated teeth restored with a composite endocrown with a 2 mm circumferential ferrule; Rct−: teeth with RCT without restoration (negative control for root-canal-treated teeth). This study design was duplicated with 3D-printed resin simulators.
Figure 2. Three-dimensional representation of the different resin simulators. (a) resin simulator representing sound teeth; (b) resin simulator representing teeth with an access cavity used as negative control; (c) resin simulator representing teeth with a flat peripherical coronal preparation, and (d) resin simulator representing teeth with a 2 mm peripherical ferrule.
Figure 3. Comparison of strength test mean values assessed for human teeth according to the type of endodontic treatment, the type of coronal preparation, and the materials used for endocrown milling (Student–Newman–Keuls post-ANOVA; ***: p < 0.001).
Figure 4. Comparison of strength test mean values assessed for resin simulators according to the type of endodontic treatment, the type of coronal preparation, and the materials used for endocrown milling (Kruskal–Wallis; *: p < 0.05, **: p < 0.01, and ***: p < 0.001).
Procedures for endodontic treatment and coronal preparation.
Endodontic Treatments | |
Root canal treatment: | The pulp chamber was opened with a diamond bur (Komet, Gebrüder Brasseler, Lemgo, Allemagne). |
Full pulpotomy: | After opening and creating the access cavity, a third coronary preparation was made with a Gates Glidden Drill no. 2 (Dentsply Sirona, Bensheim, Germany). |
Coronal Preparations | |
Flat margin coronal preparation: | The depth of occlusal reduction was marked on the teeth with a specialized bur (Deep Marker, Komet, Gebrüder Brasseler, Lemgo, Germany). The margin was regularized with a diamond wheel bur (Komet, Gebrüder Brasseler, Lemgo, Germany). |
Peripherical ferrule preparation: | After the flat margin preparation, the deep marker was reused to mark a 2 mm height on each face, and a 2 mm guided bur was used to perform the ferrule preparation. |
Endocrown Materials and Protocols | |
Restoration design and milling: | Teeth were mounted in a master model and scanned with Cerec Primescan (Dentsply Sirona Dental System, Benscheim, Germany). |
Emax adhesive protocol: | Endocrown intrados were etched for 20 s using 9% hydrofluoric acid (Porcelain Etch, Ultradent, South Jordan, USA). After rinsing (30 s) and drying, a silane coupling agent was applied for 1 min (Monobond Plus, Ivoclar Vivadent, Schaan, Lichtenstein). |
Cerasmart (GC Tokyo, Japan) adhesive protocol: | Endocrown intrados were etched for 20 s using 9% hydrofluoric acid (Porcelain Etch, Ultradent, South Jordan, USA). After rinsing (30 s) and drying, a primer agent was applied (G Multi Primer, GC, Tokyo, Japan). |
Comparison of strength test values according to the type of endodontic treatment, the type of preparation, and the materials used for endocrowns for the human teeth and the resin simulators (Kruskal–Wallis test, NS: Not Significant).
Human Teeth (p) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
C+ | FP-Fla-Ce | FP-Fla-Co | FP-Fer-Ce | FP-Fer-Co | Rct-Fla-Ce | Rct-Fla-Co | Rct-Fer-Ce | Rct-Fer-Co | FP− | Rct− | ||
Resin |
C+ | - | NS | NS | NS | NS | NS | NS | NS | NS | 0.003 | 0.009 |
FP-Fla-Ce | 0.008 | - | NS | NS | NS | NS | NS | NS | NS | <0.001 | <0.001 | |
FP-Fla-Co | NS | NS | - | NS | NS | NS | NS | NS | NS | <0.001 | <0.001 | |
FP-Fer-Ce | 0.001 | NS | NS | - | NS | NS | NS | NS | NS | <0.001 | <0.001 | |
FP-Fer-Co | NS | NS | NS | NS | - | NS | NS | NS | NS | 0.001 | 0.003 | |
Rct-Fla-Ce | <0.001 | NS | NS | NS | NS | - | NS | NS | NS | <0.001 | <0.001 | |
Rct-Fla-Ce | NS | NS | NS | NS | NS | 0.05 | - | NS | NS | <0.001 | 0.002 | |
Rct-Fer-Ce | 0.014 | NS | NS | NS | NS | NS | NS | - | NS | <0.001 | <0.001 | |
Rct-Fer-Co | NS | NS | NS | NS | NS | NS | NS | NS | - | <0.001 | <0.001 | |
FP− | NS | <0.001 | NS | <0.001 | NS | <0.001 | NS | <0.001 | 0.024 | - | NS | |
Rct− | NS | <0.001 | NS | <0.001 | NS | <0.001 | NS | <0.001 | 0.02 | NS | - |
Comparison of distribution of the type of fracture in each group for the human teeth (chi-square test, NS: Not Significant).
Group | Favorable Fracture (n) | Catastrophic |
Significance Compared with the Positive Control (p) | Significance Compared with the Negative Control (FP− or Rct−) (p) |
---|---|---|---|---|
C+ | 10 (100%) | 0 | ||
FP− | 5 (50%) | 5 (50%) | <0.01 | |
FP-Fla-Ce | 0 | 10 (100%) | <0.001 | <0.01 |
FP-Fla-Co | 3 (30%) | 7 (70%) | <0.01 | NS |
FP-Fer-Ce | 1 (10%) | 9 (90%) | <0.001 | NS |
FP-Fer-Co | 3 (30%) | 7 (70%) | <0.01 | NS |
Rct− | 4 (40%) | 6 (60%) | <0.01 | |
Rct-Fla-Ce | 2 (20%) | 8 (80%) | <0.001 | NS |
Rct-Fla-Ce | 3 (30%) | 7 (70%) | <0.01 | NS |
Rct-Fer-Ce | 2 (20%) | 8 (80%) | <0.001 | NS |
Rct-Fer-Co | 3 (30%) | 7 (70%) | <0.01 | NS |
Total | 36 (32.7%) | 74 (67.3%) |
Comparison of distribution of the type of fracture in each group for the resin simulators (chi-square test, NS: Not Significant).
Group | Favorable Fracture (n) | Catastrophic |
Significance Compared with the Positive Control (p) | Significance Compared with the Negative Control (FP− or Rct−) (p) |
---|---|---|---|---|
C+ | 0 | 10 (100%) | ||
FP− | 0 | 10 (100%) | NS | |
FP-Fla-Ce | 0 | 10 (100%) | NS | NS |
FP-Fla-Co | 1 (10%) | 9 (90%) | NS | NS |
FP-Fer-Ce | 0 | 10 (100%) | NS | NS |
FP-Fer-Co | 1 (10%) | 9 (90%) | NS | NS |
Rct− | 0 | 10 (100%) | NS | |
Rct-Fla-Ce | 0 | 10 (100%) | NS | NS |
Rct-Fla-Ce | 1 (10%) | 9 (90%) | NS | NS |
Rct-Fer-Ce | 0 | 10 (100%) | NS | NS |
Rct-Fer-Co | 0 | 10 (100%) | NS | NS |
Total | 3 (2.7%) | 107 (97.3%) |
References
1. Ferrari, M.; Pontoriero, D.I.K.; Ferrari Cagidiaco, E.; Carboncini, F. Restorative Difficulty Evaluation System of Endodontically Treated Teeth. J. Esthet. Restor. Dent.; 2022; 34, pp. 65-80. [DOI: https://dx.doi.org/10.1111/jerd.12880]
2. Dotto, L.; Girotto, L.P.S.; Correa Silva Sousa, Y.T.; Pereira, G.K.R.; Bacchi, A.; Sarkis-Onofre, R. Factors Influencing the Clinical Performance of the Restoration of Endodontically Treated Teeth: An Assessment of Systematic Reviews of Clinical Studies. J. Prosthet. Dent.; 2022; [DOI: https://dx.doi.org/10.1016/j.prosdent.2022.03.030]
3. Helfer, A.R.; Melnick, S.; Schilder, H. Determination of the Moisture Content of Vital and Pulpless Teeth. Oral Surg. Oral Med. Oral Pathol.; 1972; 34, pp. 661-670. [DOI: https://dx.doi.org/10.1016/0030-4220(72)90351-9]
4. Papa, J.; Cain, C.; Messer, H.H. Moisture Content of Vital vs Endodontically Treated Teeth. Endod. Dent. Traumatol.; 1994; 10, pp. 91-93. [DOI: https://dx.doi.org/10.1111/j.1600-9657.1994.tb00067.x]
5. Soares, C.J.; Santana, F.R.; Silva, N.R.; Preira, J.C.; Pereira, C.A. Influence of the Endodontic Treatment on Mechanical Properties of Root Dentin. J. Endod.; 2007; 33, pp. 603-606. [DOI: https://dx.doi.org/10.1016/j.joen.2007.01.016]
6. Munoz-Sanchez, M.L.; Bessadet, M.; Lance, C.; Bonnet, G.; Veyrune, J.L.; Nicolas, E.; Hennequin, M.; Decerle, N. Survival Rate of CAD-CAM Endocrowns Performed by Undergraduate Students. Oper. Dent.; 2021; 46, pp. 505-515. [DOI: https://dx.doi.org/10.2341/20-126-C]
7. Belleflamme, M.M.; Geerts, S.O.; Louwette, M.M.; Grenade, C.F.; Vanheusden, A.J.; Mainjot, A.K. No Post-No Core Approach to Restore Severely Damaged Posterior Teeth: An up to 10-Year Retrospective Study of Documented Endocrown Cases. J. Dent.; 2017; 63, pp. 1-7. [DOI: https://dx.doi.org/10.1016/j.jdent.2017.04.009]
8. Fages, M.; Raynal, J.; Tramini, P.; Cuisinier, F.J.; Durand, J.-C. Chairside Computer-Aided Design/Computer-Aided Manufacture All-Ceramic Crown and Endocrown Restorations: A 7-Year Survival Rate Study. Int. J. Prosthodont; 2017; 30, pp. 556-560. [DOI: https://dx.doi.org/10.11607/ijp.5132]
9. Munoz-Sanchez, M.-L.; Linas, N.; Decerle, N.; Nicolas, E.; Hennequin, M.; Cousson, P.-Y. A Combination of Full Pulpotomy and Chairside CAD/CAM Endocrown to Treat Teeth with Deep Carious Lesions and Pulpitis in a Single Session: A Preliminary Study. Int. J. Environ. Res. Public Health; 2020; 17, 6340. [DOI: https://dx.doi.org/10.3390/ijerph17176340]
10. Beji Vijayakumar, J.; Varadan, P.; Balaji, L.; Rajan, M.; Kalaiselvam, R.; Saeralaathan, S.; Ganesh, A. Fracture Resistance of Resin Based and Lithium Disilicate Endocrowns. Which Is Better?—A Systematic Review of in-Vitro Studies. Biomater. Investig. Dent.; 2021; 8, pp. 104-111. [DOI: https://dx.doi.org/10.1080/26415275.2021.1932510]
11. Lee, S.-J.; Lee, S.; Lim, J.; Ahn, S.-J.; Kim, T.-W. Cluster Analysis of Tooth Size in Subjects with Normal Occlusion. Am. J. Orthod. Dentofac. Orthop.; 2007; 132, pp. 796-800. [DOI: https://dx.doi.org/10.1016/j.ajodo.2005.12.037]
12. Robberecht, L.; Hornez, J.-C.; Dehurtevent, M.; Dufour, T.; Labreuche, J.; Deveaux, E.; Chai, F. Optimization and Preclinical Perception of an Artificial Simulator for Endodontic Training: A Preliminary Study. J. Dent. Educ.; 2017; 81, pp. 326-332. [DOI: https://dx.doi.org/10.1002/j.0022-0337.2017.81.3.tb06278.x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28250039]
13. Reymus, M.; Stawarczyk, B.; Winkler, A.; Ludwig, J.; Kess, S.; Krastl, G.; Krug, R. A Critical Evaluation of the Material Properties and Clinical Suitability of In-house Printed and Commercial Tooth Replicas for Endodontic Training. Int. Endod. J.; 2020; 53, pp. 1446-1454. [DOI: https://dx.doi.org/10.1111/iej.13361]
14. Höhne, C.; Schmitter, M. 3D Printed Teeth for the Preclinical Education of Dental Students. J. Dent. Educ.; 2019; 83, pp. 1100-1106. [DOI: https://dx.doi.org/10.21815/JDE.019.103]
15. Delfosse, C.; Marquillier, T.; Ndoye, S.; Cousson, P.-Y.; Hennequin, M.; Catteau, C. Effect on Undergraduate Student Self-Confidence in Using 3D Printed Primary Molars for Root Canal Treatment Simulation Training. Eur. Arch. Paediatr. Dent.; 2023; 24, pp. 105-116. [DOI: https://dx.doi.org/10.1007/s40368-022-00764-0]
16. Altier, M.; Erol, F.; Yildirim, G.; Dalkilic, E.E. Fracture Resistance and Failure Modes of Lithium Disilicate or Composite Endocrowns. Niger. J. Clin. Pract.; 2018; 21, pp. 821-826. [DOI: https://dx.doi.org/10.4103/njcp.njcp_175_17]
17. American Academy of Pediatric Dentistry. Pulp Therapy for Primary and Immature Permanent Teeth. Pediatr. Dent.; 2017; 39, pp. 325-333.
18. Eren, B.; Onay, E.O.; Ungor, M. Assessment of Alternative Emergency Treatments for Symptomatic Irreversible Pulpitis: A Randomized Clinical Trial. Int. Endod. J.; 2018; 51, pp. e227-e237. [DOI: https://dx.doi.org/10.1111/iej.12851]
19. Eghbal, M.J.; Haeri, A.; Shahravan, A.; Kazemi, A.; Moazami, F.; Mozayeni, M.A.; Saberi, E.; Samiei, M.; Vatanpour, M.; Akbarzade Baghban, A. et al. Postendodontic Pain after Pulpotomy or Root Canal Treatment in Mature Teeth with Carious Pulp Exposure: A Multicenter Randomized Controlled Trial. Pain. Res. Manag.; 2020; 2020, 5853412. [DOI: https://dx.doi.org/10.1155/2020/5853412]
20. Asgary, S.; Fazlyab, M.; Sabbagh, S.; Eghbal, M. Outcomes of Different Vital Pulp Therapy Techniques on Symptomatic Permanent Teeth: A Case Series. Iran. Endod. J.; 2014; 9, pp. 295-300.
21. Awawdeh, L.; Al-Qudah, A.; Hamouri, H.; Chakra, R.J. Outcomes of Vital Pulp Therapy Using Mineral Trioxide Aggregate or Biodentine: A Prospective Randomized Clinical Trial. J. Endod.; 2018; 44, pp. 1603-1609. [DOI: https://dx.doi.org/10.1016/j.joen.2018.08.004] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/30292451]
22. Taha, N.A.; Abdelkhader, S.Z. Outcome of Full Pulpotomy Using Biodentine in Adult Patients with Symptoms Indicative of Irreversible Pulpitis. Int. Endod. J.; 2018; 51, pp. 819-828. [DOI: https://dx.doi.org/10.1111/iej.12903] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29397003]
23. Zanini, M.; Hennequin, M.; Cousson, P. Which Procedures and Materials Could Be Applied for Full Pulpotomy in Permanent Mature Teeth? A Systematic Review. Acta Odontol. Scand.; 2019; 77, pp. 541-551. [DOI: https://dx.doi.org/10.1080/00016357.2019.1614217] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/31146622]
24. Sarao, S.K.; Berlin-Broner, Y.; Levin, L. Occurrence and Risk Factors of Dental Root Perforations: A Systematic Review. Int. Dent. J.; 2021; 71, pp. 96-105. [DOI: https://dx.doi.org/10.1111/idj.12602] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32815551]
25. Bhuva, B.; Giovarruscio, M.; Rahim, N.; Bitter, K.; Mannocci, F. The Restoration of Root Filled Teeth: A Review of the Clinical Literature. Int. Endod. J.; 2021; 54, pp. 509-535. [DOI: https://dx.doi.org/10.1111/iej.13438]
26. Biacchi, G.R.; Mello, B.; Basting, R.T. The Endocrown: An Alternative Approach for Restoring Extensively Damaged Molars. J. Esthet. Restor. Dent.; 2013; 25, pp. 383-390. [DOI: https://dx.doi.org/10.1111/jerd.12065]
27. Magne, P.; Goldberg, J.; Edelhoff, D.; Güth, J.-F. Composite Resin Core Buildups With and Without Post for the Restoration of Endodontically Treated Molars Without Ferrule. Oper. Dent.; 2016; 41, pp. 64-75. [DOI: https://dx.doi.org/10.2341/14-258-L]
28. Bürklein, S.; Börjes, L.; Schäfer, E. Comparison of Preparation of Curved Root Canals with Hyflex CM and Revo-S Rotary Nickel-Titanium Instruments. Int. Endod. J.; 2014; 47, pp. 470-476. [DOI: https://dx.doi.org/10.1111/iej.12171]
29. Gavini, G.; Caldeira, C.L.; Akisue, E.; Candeiro, G.T.D.M.; Kawakami, D.A.S. Resistance to Flexural Fatigue of Reciproc R25 Files under Continuous Rotation and Reciprocating Movement. J. Endod.; 2012; 38, pp. 684-687. [DOI: https://dx.doi.org/10.1016/j.joen.2011.12.033]
30. Usman, N.; Baumgartner, J.; Marshall, J. Influence of Instrument Size on Root Canal Debridement. J. Endod.; 2004; 30, pp. 110-112. [DOI: https://dx.doi.org/10.1097/00004770-200402000-00012]
31. Puleio, F.; Lo Giudice, G.; Militi, A.; Bellezza, U.; Lo Giudice, R. Does Low-Taper Root Canal Shaping Decrease the Risk of Root Fracture? A Systematic Review. Dent. J.; 2022; 10, 94. [DOI: https://dx.doi.org/10.3390/dj10060094] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/35735636]
32. Gulec, L.; Ulusoy, N. Effect of Endocrown Restorations with Different CAD/CAM Materials: 3D Finite Element and Weibull Analyses. BioMed Res. Int.; 2017; 2017, 5638683. [DOI: https://dx.doi.org/10.1155/2017/5638683] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29119108]
33. Abtahi, S.; Alikhasi, M.; Siadat, H. Biomechanical Behavior of Endocrown Restorations with Different Cavity Design and CAD-CAM Materials under a Static and Vertical Load: A Finite Element Analysis. J. Prosthet. Dent.; 2022; 127, pp. 600.e1-600.e8. [DOI: https://dx.doi.org/10.1016/j.prosdent.2021.11.027]
34. Meng, Q.; Zhang, Y.; Chi, D.; Gong, Q.; Tong, Z. Resistance Fracture of Minimally Prepared Endocrowns Made by Three Types of Restorative Materials: A 3D Finite Element Analysis. J. Mater. Sci. Mater. Med.; 2021; 32, 137. [DOI: https://dx.doi.org/10.1007/s10856-021-06610-x]
35. He, J.; Zheng, Z.; Wu, M.; Zheng, C.; Zeng, Y.; Yan, W. Influence of Restorative Material and Cement on the Stress Distribution of Endocrowns: 3D Finite Element Analysis. BMC Oral Health; 2021; 21, 495. [DOI: https://dx.doi.org/10.1186/s12903-021-01865-w] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/34610825]
36. Zheng, Z.; He, Y.; Ruan, W.; Ling, Z.; Zheng, C.; Gai, Y.; Yan, W. Biomechanical Behavior of Endocrown Restorations with Different CAD-CAM Materials: A 3D Finite Element and in Vitro Analysis. J. Prosthet. Dent.; 2021; 125, pp. 890-899. [DOI: https://dx.doi.org/10.1016/j.prosdent.2020.03.009]
37. Zheng, Z.; Sun, J.; Jiang, L.; Wu, Y.; He, J.; Ruan, W.; Yan, W. Influence of Margin Design and Restorative Material on the Stress Distribution of Endocrowns: A 3D Finite Element Analysis. BMC Oral Health; 2022; 22, 30. [DOI: https://dx.doi.org/10.1186/s12903-022-02063-y]
38. Sedrez-Porto, J.A.; Rosa, W.L.d.O.d.; da Silva, A.F.; Münchow, E.A.; Pereira-Cenci, T. Endocrown Restorations: A Systematic Review and Meta-Analysis. J. Dent.; 2016; 52, pp. 8-14. [DOI: https://dx.doi.org/10.1016/j.jdent.2016.07.005]
39. Acar, D.H.; Kalyoncuoğlu, E. The Fracture Strength of Endocrowns Manufactured from Different Hybrid Blocks under Axial and Lateral Forces. Clin. Oral Investig.; 2021; 25, pp. 1889-1897. [DOI: https://dx.doi.org/10.1007/s00784-020-03495-y] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32813076]
40. Sedrez-Porto, J.A.; Münchow, E.A.; Cenci, M.S.; Pereira-Cenci, T. Which Materials Would Account for a Better Mechanical Behavior for Direct Endocrown Restorations?. J. Mech. Behav. Biomed. Mater.; 2020; 103, 103592. [DOI: https://dx.doi.org/10.1016/j.jmbbm.2019.103592]
41. Pedrollo Lise, D.; Van Ende, A.; De Munck, J.; Umeda Suzuki, T.Y.; Cardoso Vieira, L.C.; Van Meerbeek, B. Biomechanical Behavior of Endodontically Treated Premolars Using Different Preparation Designs and CAD/CAM Materials. J. Dent.; 2017; 59, pp. 54-61. [DOI: https://dx.doi.org/10.1016/j.jdent.2017.02.007] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/28214537]
42. El-Damanhoury, H.M.; Haj-Ali, R.N.; Platt, J.A. Fracture Resistance and Microleakage of Endocrowns Utilizing Three CAD-CAM Blocks. Oper. Dent.; 2015; 40, pp. 201-210. [DOI: https://dx.doi.org/10.2341/13-143-L] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/25268039]
43. Matzinger, M.; Hahnel, S.; Preis, V.; Rosentritt, M. Polishing Effects and Wear Performance of Chairside CAD/CAM Materials. Clin. Oral Investig.; 2019; 23, pp. 725-737. [DOI: https://dx.doi.org/10.1007/s00784-018-2473-3] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/29770877]
44. Vanoorbeek, S.; Vandamme, K.; Lijnen, I.; Naert, I. Computer-Aided Designed/Computer-Assisted Manufactured Composite Resin versus Ceramic Single-Tooth Restorations: A 3-Year Clinical Study. Int. J. Prosthodont; 2010; 23, pp. 223-230. [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/20552087]
45. Carvalho, A.O.; Bruzi, G.; Anderson, R.E.; Maia, H.P.; Giannini, M.; Magne, P. Influence of Adhesive Core Buildup Designs on the Resistance of Endodontically Treated Molars Restored With Lithium Disilicate CAD/CAM Crowns. Oper. Dent.; 2016; 41, pp. 76-82. [DOI: https://dx.doi.org/10.2341/14-277-L]
46. Kayahan, M.B.; Nekoofar, M.H.; Kazandağ, M.; Canpolat, C.; Malkondu, O.; Kaptan, F.; Dummer, P.M.H. Effect of Acid-Etching Procedure on Selected Physical Properties of Mineral Trioxide Aggregate. Int. Endod. J.; 2009; 42, pp. 1004-1014. [DOI: https://dx.doi.org/10.1111/j.1365-2591.2009.01610.x]
47. Subash, D.; Shoba, K.; Aman, S.; Bharkavi, S.K.I.; Nimmi, V.; Abhilash, R. Fracture Resistance of Endodontically Treated Teeth Restored with Biodentine, Resin Modified GIC and Hybrid Composite Resin as a Core Material. J. Clin. Diagn. Res.; 2017; 11, pp. ZC68-ZC70. [DOI: https://dx.doi.org/10.7860/JCDR/2017/28263.10625]
48. Al-Manei, K.K. Shear Bond Strength of E. Max Ceramic Restoration to Hydraulic Calcium Silicate Based Cement (Biodentine): An In Vitro Study. Eur. Endod. J.; 2020; 5, pp. 288-294. [DOI: https://dx.doi.org/10.14744/eej.2020.75046]
49. Pradelle-Plasse, N.; Mocquot, C.; Semennikova, K.; Colon, P.; Grosgogeat, B. Interface between Calcium Silicate Cement and Adhesive Systems According to Adhesive Families and Cement Maturation. Restor. Dent. Endod.; 2021; 46, e3. [DOI: https://dx.doi.org/10.5395/rde.2021.46.e3]
50. Ahmed, M.A.A.; Kern, M.; Mourshed, B.; Wille, S.; Chaar, M.S. Fracture Resistance of Maxillary Premolars Restored with Different Endocrown Designs and Materials after Artificial Ageing. J. Prosthodont. Res.; 2022; 66, pp. 141-150. [DOI: https://dx.doi.org/10.2186/jpr.JPR_D_20_00082]
51. Einhorn, M.; DuVall, N.; Wajdowicz, M.; Brewster, J.; Roberts, H. Preparation Ferrule Design Effect on Endocrown Failure Resistance: Ferrule Design Effect Endocrown Failure Resistance. J. Prosthodont.; 2019; 28, pp. e237-e242. [DOI: https://dx.doi.org/10.1111/jopr.12671]
52. Tribst, J.P.M.; de Oliveira Dal Piva, A.M.; Jager, N.; Bottino, M.A.; Kok, P.; Kleverlaan, C.J. Full-Crown Versus Endocrown Approach: A 3D-Analysis of Both Restorations and the Effect of Ferrule and Restoration Material. J. Prosthodont.; 2021; 30, pp. 335-344. [DOI: https://dx.doi.org/10.1111/jopr.13244] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/32856743]
53. Iaculli, F.; Rengo, C.; Lodato, V.; Patini, R.; Spagnuolo, G.; Rengo, S. Fracture Resistance of Endodontically-Treated Maxillary Premolars Restored with Different Type of Posts and Direct Composite Reconstructions: A Systematic Review and Meta-Analysis of in Vitro Studies. Dent. Mater.; 2021; 37, pp. e455-e484. [DOI: https://dx.doi.org/10.1016/j.dental.2021.06.007]
54. Lin, C.-L.; Chang, Y.-H.; Chang, C.-Y.; Pai, C.-A.; Huang, S.-F. Finite Element and Weibull Analyses to Estimate Failure Risks in the Ceramic Endocrown and Classical Crown for Endodontically Treated Maxillary Premolar. Eur. J. Oral Sci.; 2010; 118, pp. 87-93. [DOI: https://dx.doi.org/10.1111/j.1600-0722.2009.00704.x] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/20156270]
55. Huang, T.-J.G.; Schilder, H.; Nathanson, D. Effects of Moisture Content and Endodontic Treatment on Some Mechanical Properties of Human Dentin. J. Endod.; 1992; 18, pp. 209-215. [DOI: https://dx.doi.org/10.1016/S0099-2399(06)81262-8] [PubMed: https://www.ncbi.nlm.nih.gov/pubmed/1402574]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Endocrowns are designed to restore endodontically treated teeth with root canal treatment (Rct). Recently, endocrowns were proposed for teeth treated with full pulpotomy (FP). No data exist on in vitro evaluations for this combination. This study aimed to evaluate the mechanical behavior of pulpotomy-treated teeth with endocrowns according to different protocols for preparation design and materials and to assess whether 3D-printed resin simulators could be a reliable alternative for human teeth during in vitro strength tests. One hundred and ten extracted natural molars were randomized into 11 groups according to the type of endodontic treatment, the material used, and the design of peripheric preparation. One hundred and ten resin simulators were separated similarly. The samples were embedded in epoxy resin blocks before being subjected to oblique compressive load until failure. For natural teeth, the variance analysis separated two homogeneous groups, one regrouping the endodontically treated or pulpotomy-treated teeth without coronal restoration and the other one regrouping all the other samples, i.e., the untreated teeth (positive controls) and the treated and restored teeth. The strength resistance was lower for the resin simulators than for natural teeth in all groups. Within the limit of this study, strength resistance is not the most important criterion for choosing the type of material, preparation, or endodontic treatment for endocrowns. Resin simulators are not efficient for in vitro strength studies.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details



1 Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, F-63000 Clermont-Ferrand, France;
2 Institut Pascal UMR CNRS 6602, Université Clermont Auvergne, F-63000 Clermont-Ferrand, France;
3 Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, F-63000 Clermont-Ferrand, France;