Full Text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

The type of implant-abutment connection is one of the factors influencing the distribution of occlusal forces. This study aims to investigate the biomechanical performance of the mandibular all-on-4 treatment with different implant–abutment connections. Two connection types with 30° abutments and 18-mm implant fixtures were chosen for the posterior implants of the all-on-4 assembly. For the external hexagon connection (EHC) group, the implants with 4 mm in diameter were used. For the internal hexagon connection (IHC) group, we selected implants with 4.3 mm in diameter. A vertical force of 190 N was applied to the cantilever region. The FEA results indicated that the most stressed region in the two groups was prosthetic screws, followed by multi-unit abutments (MUAs). The lowest values of von Mises stress were both observed on the bone. The peak stress value of the implant screw and implant fixture in the EHC group were 37.75% and 33.03% lower than the IHC group, respectively. For stress distribution patterns, the load force tended to be concentrated at locations where components were interconnected. The EHC and IHC are clinically durable under the tested loading conditions, but the prosthetic screws and MUAs can be the weak point on the posterior implant within the mandibular all-on-four assembly. The peak stress values of implant screw and implant fixture in the EHC groups were lower than the IHC group.

Details

Title
Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant–Abutment Connections: A Three-Dimensional Finite Element Study
Author
Wang, Pei-Shuang 1 ; Ming-Hsu, Tsai 2   VIAFID ORCID Logo  ; Yu-Ling, Wu 1 ; Chen, Hung-Shyong 3 ; Yao-Ning, Lei 1 ; Aaron Yu-Jen Wu 1   VIAFID ORCID Logo 

 Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan 
 Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan 
 Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan; Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833, Taiwan 
First page
515
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
20794983
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2882585116
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.