1 Introduction
Sea spray aerosol (SSA) is a major natural source of aerosols produced when wave breaking entrains air into ocean surface water, which subsequently breaks up into bubbles. These bubbles rise to the surface, where they burst and produce both a large number of relatively small film drops resulting from the disintegration of the bubble film cap (for bubbles with diameters 2 mm) and a smaller number of jet drops resulting from the collapse of the bubble cavity, which are typically larger in size than the film drops . Along with wind speed, sea state, seawater temperature, salinity, and the physicochemical and biological state of the ocean have been shown to influence the production of SSA
SSA can have a significant impact on Earth's radiation budget by scattering incoming solar radiation directly and by acting as cloud condensation nuclei . Although coarse-mode SSA typically dominates mass emissions, fine-mode SSA has a more significant impact on radiative transfer because it more effectively scatters solar radiation under clear-sky conditions . In addition, sub-micrometre SSA plays a crucial role in the concentration of cloud condensation nuclei . Therefore, it is necessary to parameterize the entire SSA size spectrum to obtain better estimates of climate forcing from model simulations.
Many sea spray source functions have been presented in the literature, varying by more than an order of magnitude at any given wind speed . One reason for the discrepancy could be the method used to obtain sea spray source functions. For example, Liu et al. (2021) used particle diameters as a proxy for sea salt, which is not representative of sea spray source functions. Another reason for this may be the large number of environmental variables that impact the SSA production process. For instance, while SSA production has traditionally been parameterized as a function of wind speed, recent studies have attempted to include the impact of seawater temperature
The large variability in sea spray source functions produced by different laboratory studies may also be due to the different approaches used to derive them. Three types of approaches have been used to estimate SSA emissions. The first approach uses laboratory experiments to mimic the wave-breaking process
Many studies estimate SSA emission fluxes indirectly using laboratory experiments. In these experiments, SSA is generated under controlled conditions using wave chambers
In contrast to indirect laboratory approaches, the eddy covariance (EC) method provides direct estimates of vertical turbulent aerosol fluxes . However, relatively few studies have used the EC method to estimate SSA emission fluxes over the open sea . Although this approach has the advantage of directly quantifying SSA emission fluxes, a major drawback is the requirement for aerosol instrumentation capable of fast response and sampling rates. Since optical particle counters (OPCs) are currently the only fast-response aerosol instruments that provide size-resolved measurements, the EC method is limited to the particle size range covered by these instruments, typically 0.1 (where denotes the dry particle diameter). Thus, obtaining size-resolved SSA fluxes across the full size spectrum relevant to SSA emissions using the EC method remains challenging. In addition, another drawback of the EC method is that it cannot provide information on the chemical and microbial properties of the aerosols and therefore cannot quantify the emission flux of bacteria associated with SSA, for example.
To circumvent these issues, attempted to scale laboratory-derived SSA emission estimates to in situ EC SSA emissions measured at a coastal sampling site in the Baltic Sea. They obtained a wind-speed-dependent SSA emission flux over the particle size range of . However, as their dataset had only a limited number of data points from an open-sea sector, fluxes from sectors with short fetch, and shallow waters that had to be included. As these sectors were likely affected by coastal wave breaking, the usefulness of their measurements in understanding open-sea SSA emissions is likely limited. To address this issue, we conducted two field campaigns in the Baltic Sea. During these campaigns, we conducted EC flux measurements on the island of Östergarnsholm and simultaneously performed measurements using a laboratory sea spray simulation chamber filled with fresh seawater collected within the flux footprint area. Our EC analysis focused on sectors representing open-sea conditions. Combining these two approaches allowed us to directly quantify the magnitude of the SSA flux and to extend our emission estimates below the lower particle size limit of the OPC, obtaining wind-speed- and wave-state-dependent SSA emission fluxes over the particle size range of . The parameterizations developed in this study mark the first of their kind for low-salinity waters. While previous parameterizations were based on a global oceanic average salinity of 35 g kg, our work specifically addresses the unique conditions of low-salinity environments. Additionally, the scaling factor established through our study will enable quantification of emission fluxes of specific particle classes emitted with SSA, such as organics or bacteria in future work.
2 Measurement site and methods
To estimate SSA production fluxes using both in situ EC measurements and a laboratory sea spray simulation chamber, we conducted co-located ship-based experiments near the Integrated Carbon Observation System (ICOS) station on the island of Östergarnsholm in the Baltic Sea (572548.4 N, 185902.9 E). We carried out two campaigns, the first using the Polish research vessel Oceania in May 2021 and the second using the Swedish research vessel Electra in August 2021. Throughout both campaigns, the sea spray simulation chamber was positioned aboard ships, which were stationary in close proximity to the flux footprint area of the EC flux tower. To avoid disturbing the EC flux measurements during the first campaign, R/V Oceania was anchored approximately 5 km away from the station. This distance kept the ship outside the flux footprint. During the second campaign, R/V Electra was anchored near the island in a wind sector influenced by the presence of Gotland. We excluded data from this sector since it could have affected our measurements.
Extensive studies have been conducted on the footprint of the EC flux tower, and identified an open-sea sector from 80 to 220 south of the station that has an undisturbed wave field without bottom topography or coastal features. In this sector, the ocean depth rapidly increases to deeper than 20 m. However, in the sector north of 80, the water is shallower and the bottom topography is likely to influence SSA emissions. Similarly, SSA emissions in the sector west and north of 220 are likely to be influenced by the presence of Gotland and the island of Östergarnsholm, and the bottom topography is likely to affect the wave field properties when the wave period is high. Therefore, in our data analysis, we only used aerosol EC fluxes obtained within the 80–220 sector. Figure depicts the locations of the flux station and the ships as well as the wind sectors identified by .
Figure 1
This map shows the locations of the EC flux tower on the island of Östergarnsholm (red triangle) and the research vessels, along with the positions of the EXO2 multi-parameter sensor and waverider buoy. Reference pictures of the flux tower are also included. Wind sectors are identified based on the classification by . Map BSHC.
[Figure omitted. See PDF]
2.1 EC aerosol flux towerStockholm University has installed a 12 m tower for measuring aerosol EC fluxes adjacent to the 30 m ICOS mast on Östergarnsholm, as shown in Fig. , which is used to measure EC greenhouse gas fluxes. A horizontal head ultrasonic anemometer (Gill HS, Gill Instruments Ltd, UK) was placed on a platform at the top of the aerosol flux tower, with the three-axis sonic head 12 m above the average sea surface level. Wind speed in three dimensions (, , ) and the atmospheric temperature derived from the speed of sound () were recorded at 20 Hz. The open side of the horizontal head faced south to maximize the quality of measurements in the open-sea sector (80–220).
A high-speed open-path HO and CO sensor was mounted at 10.4 m height on a co-located mast with 8 m horizontal separation and recorded at 20 Hz (Licor-7500A, Li-Cor Environmental Ltd, UK).
Ambient air was sampled vertically downward through a 5 m long stainless-steel sampling line with a (6.35 mm) outer diameter (5.35 mm inner diameter). To prevent precipitation from entering the sampling line, a 180 bend was installed at the top of the sample line. The sampling line led to an OPC (model 1.109, Grimm Aerosol Technik GmbH, Germany) that sampled at 1.2 L min and that was mounted on a second platform at 7 m height. The OPC was calibrated by Grimm Aerosol Technik GmbH, and its first-order response time (see Sect. A1.2) was measured at the Department of Environmental Science, Stockholm University. The OPC was set to count the aerosol number concentration in 15 size classes with diameters , with a time resolution of 1 s. Given the flow through the sample line and the dimensions of the tube, the flow in the sampling line should have been laminar ( 322), where is the sampling flow of the OPC, is the diameter of the sampling line, and is the kinematic viscosity.
Because access to the sampling site is limited and the amount of electrical power at the site is restricted, it was not possible to dry the aerosol sample. Therefore, the OPC conducted all measurements at ambient temperature and humidity. All the instruments were recorded and monitored using a gateway and PC running the LabVIEW software SCOL-EC developed by Stockholm University .
2.2 EC method and calculations
To estimate aerosol fluxes using the EC method, high-frequency measurements of aerosol number concentrations are correlated with the vertical wind speed . These measurements are averaged over time, typically at 30 min intervals, to obtain the total and size-resolved net aerosol fluxes ( and ), represented here using overlines and primes () to denote the 30 min means and turbulent fluctuations, respectively. The net aerosol fluxes are a result of transport caused by both upward motions (emission fluxes) and downward eddy motions (deposition fluxes). However, only emissions from sources within the flux footprint will contribute to upward fluxes. Aerosol particles that originate outside the flux footprint will not have a positive correlation with the vertical wind component and thus will not contribute to upward fluxes. Instead, they will contribute to downward fluxes through dry deposition. Therefore, by estimating the dry deposition flux and subtracting it from the net aerosol flux, it is possible to derive the SSA emission flux.
The CALCEDDY LabVIEW program, which was developed at Stockholm University , was used for eliminating spikes exceeding 6 times the standard deviation, double rotation of the coordinates, linear detrending of the data, correcting for lags (using a lag time ranging from 0 to 9 s with the largest correlation between and ), and calculating covariances, averages, and standard deviations.
2.3 EC footprint
In the simplest terms, the flux footprint refers to the area that the instruments on the tower “see”. It represents the area upwind of the tower within which aerosol fluxes are detected by these instruments. Under stationary conditions, the footprint represents the area from where the measured fluxes originate, whether they are fluxes of momentum, heat, gases, or aerosols. The size of the footprint depends on various factors, such as the measurement height , atmospheric stability , friction velocity , and wind direction. Several methods can be used to determine the footprint. In the case of Östergarnsholm, it has been thoroughly studied using backward dispersion modelling and flux footprint modelling . According to , for measurements taken at a height of 10 m above the surface, 80 % of the fluxes originated 800 m upwind of the tower for unstable atmospheric stability conditions, 1500 m upwind of the tower for neutral atmospheric stability conditions, and 6500 m upwind of the tower for stable atmospheric conditions.
2.4 EC aerosol flux errors
In order to quantify aerosol fluxes using the EC approach, we need to consider potential measurement errors resulting from physical phenomena, instrument problems, and the specifics of our particular set-up. Although there are a number of potential flux errors, many can be prevented, minimized, or corrected. In this section, we introduce the different corrections we have applied to process our data. Further details can be found in Appendix .
We distinguish between two types of errors: random stochastic errors () and systematic errors (). For most systematic errors, there are established methods to estimate the error, which allows us to correct the measurements. In this study, systematic errors were calculated in MATLAB version 9.90.2037887 (R2022b) update 8 using the AERosol Eddy Covariance flux errors and corrections (AEREC) 2.0 code developed at Stockholm University. However, for random errors, we can only estimate the magnitude () using statistical relationships. In the following, we provide a description of the errors that we have quantified, with an emphasis on aerosol flux errors.
2.4.1 Systematic EC aerosol flux errors
Systematic errors can result in a fixed bias, a relative bias that scales with the magnitude of what is being measured, or a bias that varies over time. In the EC flux system used in this study, the lateral separation between the sonic anemometer and the OPC results in a negligible error (), especially considering that the OPC data were only recorded at 1 Hz. We calculated aerosol EC fluxes for 30 min periods, which is a standard approach in many EC studies
Differences in the properties of the footprint in the sectors surrounding the mast can also cause errors when the instantaneous wind direction changes during the 30 min flux periods. However, we will only consider data from the open-sea sector in our analysis, assuming that the surface properties of the footprint in this sector are fairly consistent.
Other systematic errors are large enough that we need to try to quantify them and correct the observed flux for these errors. These include the error introduced by flux losses at high frequency in closed-path systems, which is often referred to as low-pass filtering, i.e. signal damping in the sampling line to the OPC and the limited response time of the OPC. We also need to consider the effect of density fluctuations (Webb correction).
A short summary of systematic errors, along with their estimated magnitudes, is provided below in the order in which they were estimated and corrected. Table in Sect. summarizes the results (see also Fig. S1 in the Supplement). For a more detailed description of the error estimation and corrections, refer to Sect. in the Appendix.
One of the largest sources of error results from the attenuation of turbulent fluctuations in the sampling line and the OPC, which leads to an underestimation of the EC flux that is almost constant across all the particle sizes (except for the largest size bins). This error is significant, corresponding to 14.8 % of the observed EC flux (see Table and Fig. S1).
The impact of the limited response time of the OPC was estimated on the basis of . To include the smallest eddies in EC fluxes, instruments capable of high-frequency measurements (10–20 Hz) are required. However, since the OPC used in this study was only capable of making measurements at 1 Hz, there is a substantial attenuation of the flux in our measurements that is almost constant with size (except for the largest size bins). When normalized to the average total number flux, this error corresponds to 13.3 of the total aerosol number flux (see also Fig. S1 and Table ).
High-frequency losses were assessed using two different methods: (1) following the approach by and (2) comparing the co-spectrum to the co-spectrum of heat. The estimated high-frequency flux losses ranged from 1 % to 13.9 %.
Losses of aerosols due to particle diffusion, impaction, and sedimentation within the sampling line can lead to an underestimation of the measured aerosol number concentration that varies with particle size. To estimate these losses, we used a program developed by . Since we minimized the bends and the length of the sampling line to the OPC and since most of the particles measured by the OPC fall within the accumulation mode, the losses in the sampling line were relatively small. When normalized to the average total number flux, the errors due to losses in the sampling range were from 0.6 for the smallest OPC size bin centred at to 1.5 for the largest OPC size bin centred at (see Fig. S1 and Table ).
To account for the influence of water vapour fluxes on scalar concentrations of interest relative to total moist air, a correction known as Webb correction is required . This error accounted for 5.3 % relative error in the smallest size bin to 0 % in the largest size bin (see Table and Fig. S1). One possible explanation for the small magnitude of this correction is the damping of density fluctuations in the sampling line. This aligns with the observations of , who noted a significant dampening of water vapour fluctuations in their sampling lines.
2.4.2 Random EC aerosol flux errors
Random errors are dependent on the sample size, and as such a higher number of data points result in smaller random errors because they average out. When calculating EC fluxes, it is essential to consider a number of random errors, including variations in the prevailing wind direction and resulting differences in footprint properties during the 30 min averaging periods. However, as mentioned previously, we only considered fluxes obtained during periods when the wind blew from the open-sea sector, assuming that the footprint surface properties were similar across this sector.
For particle-counting instruments such as OPCs and CPCs, a fraction of the random error is related to the discrete counting of the particles. The discrete counting error increases with increasing particle size and decreasing particle concentration. In the case of this dataset, the discrete counting error accounted for a relative flux error of 3 (maximum 12.9 % at ). The random error was determined to vary between 35 % and 42 %, obtained by shifting and by 3 min and 5 min, respectively, and calculating the standard deviation of the computed co-variance. Unlike systematic errors, random errors cannot be corrected, and instead we will indicate them as error bars in the following data analysis.
2.5 Estimation of sea spray aerosol emission fluxes using an aerosol dry deposition model
To estimate the actual SSA emissions, we need to model the dry deposition fluxes and subtract them from the corrected net aerosol fluxes. To do so, we use
1 Here is the size-dependent aerosol dry deposition velocity for each size bin diameter , following the approach of and . We use the parameterization of dry aerosol deposition by for , set for the wind tunnel parameters corresponding to water surfaces at ms. Therefore, the emission flux for the entire OPC size range is 2
2.6 Spectral analysisTo identify EC data points that should be excluded from the analysis, we calculated the turbulence power spectra and co-spectra using a fast Fourier transform (FFT) for each 30 min time period. The power spectra and co-spectra were frequency-weighted and normalized by the variance or covariance, respectively. We excluded a 30 min period if the slope of the power spectrum deviated notably from on the normalized scale in the inertial sub-range or if the slope approached 1 (white noise) at a frequency lower than the expected response time of the instrument. Similarly, we excluded a 30 min period if the slope of the co-spectra deviated notably from the slope. We divided the 30 min time periods into three categories: (A) good data, (B) non-ideal data, and (C) poor data. Examples of the power spectra and co-spectra for aerosol, temperature, horizontal wind speed, and water vapour fluxes for “good data” are presented in Fig. S2. As can be seen in Fig. S3, the impact of the spectral analysis on the size-resolved fluxes was small. In the following analysis, we used only data from 30 min periods that were classified as “good”.
2.7 Production of nascent SSA using a laboratory sea spray simulation chamber
A laboratory sea spray simulation chamber was used to generate nascent SSA during two research cruises in the vicinity of Östergarnsholm. R/V Oceania was stationed there from 19 May 2021 at 16:00 to 22 May 2021 at 00:00 (local time, LT) and again from 23 May 2021 at 00:00 to 24 May 2021 at 04:00 LT. R/V Electra was also in the area from 10 August 2021 at 09:30 to 22 August 2021 at 08:00 LT but had to leave its anchored position on 16 August at 08:00 LT to return to the harbour in Fårösund for refuelling due to poor weather conditions. The ship returned to Östergarnsholm on 18 August at 08:00 LT, but it was not possible to anchor in the same position, and the ship had to return to the nearby harbour each evening (17:00–08:00 LT) until the end of the campaign. Therefore, in the following sections, we only include chamber measurements obtained when the ship was located close to the station on Östergarnsholm.
The sea spray simulation chamber used for the experiments is described in detail in . In summary, SSA particles were generated by a plunging jet that hits the water surface from a height of 40 cm, entraining air into the water. The entrained air rises in the form of bubbles that burst and expel droplets, which are eventually dried and sampled into aerosol instrumentation. The sea spray simulation chamber operates under a slight positive pressure by introducing particle-free sweep air to exclude the possibility of outside air contamination and to ensure that the headspace of the chamber is well-mixed. Although the chamber can be temperature-controlled, it was operated without temperature control in this study because the seawater in the chamber was constantly being replaced and thus was at ambient temperature. This makes our experiments comparable to previous chamber experiments that used a plunging jet and fresh seawater
2.7.1 Measurements of the aerosol size distribution
The size distribution of the aerosols produced in the chamber was measured using a custom-built differential mobility particle sizer (DMPS), which consisted of a Vienna-type differential mobility analyser (DMA) and a condensation particle counter (CPC, model 3772, TSI, USA) with a flow rate of 1 L min that measured particles with electrical mobility diameters between and distributed over 37 size bins. We also used a white-light optical particle size spectrometer with a flow rate of 5 L min (WELAS 2300 HP sensor and Promo 2000 H, Palas GmbH, Germany, hereafter called WELAS), which measured particles with optical diameters between and distributed over 59 bins. To combine the size distributions measured by the DMPS and WELAS, we have converted the optical diameters measured by WELAS to volume-equivalent diameters assuming a refractive index of for sea salt particles, which corresponds to the value of NaCl . We carried out the conversion using the software provided by the manufacturer (PDAnalyze Version No. 2.024, Palas GmbH, Karlsruhe, Germany), which was based on instrument-specific Mie calculations. The diameters of the aerosol particles were also shape-corrected according to . Before sampling, we dried the particle-laden air in two Nafion dryers (model MD-700-36F/48F, Perma Pure, USA) that were horizontally mounted in front of the DMPS and WELAS. We monitored the temperature and relative humidity (RH) of the sample with two sensors (HYTELOG-USB, B+B Thermo-Technik GmbH) mounted in front of the sampling inlets of the WELAS and DMPS system to ensure that the measured particle diameters could be considered dry diameters. The average RH (measured behind WELAS) was for the Oceania campaign and for the Electra campaign (mean standard deviation).
To estimate losses in the sampling lines we used the Particle Loss Calculator Software . After correcting for all factors, we combined the DMPS and WELAS data at measured particle sizes of 0.35 . All sizing instruments were calibrated with polystyrene latex spheres.
2.7.2 Derivation of SSA production fluxes from the chamber measurements using the continuous whitecap method
To estimate the production flux of SSA particles using chamber measurements, we employed the continuous whitecap method
One of the most widely used sea spray source functions is based on the discrete whitecap method
3 It is important to note a key difference between the CWM we used and the DWM developed by Monahan and colleagues
To calculate the SSA production flux , we multiply the flux per whitecap area by the whitecap coverage using the following equation: 4 where is the measured size distribution, is the sweep flow, and is the seawater surface area inside the chamber covered by bubbles. However, our experimental set-up has a limitation: we did not determine the exact surface area of seawater covered by bubbles. For future research, we recommend measuring both air entrainment and the fraction of the water surface within the chamber covered by bubbles to improve flux estimates through this scaling approach. As an approximation, we estimated the fraction of the water surface covered by bubbles in previous experiments with artificial seawater at a salinity of g kg, C, and L min (Salter et al., 2014). These authors used a wide-angle lens to photograph the water surface inside the chamber, determining that approximately 6 % of the surface was covered by bubbles. Since these photos were taken at higher salinities, with an expectation of more and smaller bubbles, we adjusted the estimate, resulting in whitecap coverages of 2 % and 3 % for the Electra campaign at flow rates of 1.3 and 2.6 L min, respectively. Considering the Oceania campaign's significantly higher jet flow rate (3.5 L min) leading to increased bubble formation, we estimate that 21 % of the water surface in the chamber was covered by bubbles during this campaign. Those whitecap coverage estimates were determined by comparing the flux that would result from 100 % whitecap coverage to the magnitude of the emission fluxes derived from the EC measurements in the overlapping size range.
2.7.3 Derivation of SSA production fluxes from the chamber measurements using air entrainmentAnother method for obtaining estimates of the production flux of SSA particles from breaking waves and whitecaps using sea spray simulation chambers has been developed by and . These authors combined the number of particles produced per unit time in a logarithmic interval of with measurements of air entrainment or detrainment. This approach assumes that all air entrained into the water column detrains as bubbles that produce particles and does not consider other factors that may affect the air entrainment flux, such as breaking wave strength or sea state.
To apply this approach, we measured the volume of air entrained in a manner similar to under conditions relevant to our field measurements, using seawater from the footprint area ( g kg, C, and C, respectively, for the May and August campaigns). To measure the volume of air entrained by the plunging jet, we enclosed the jet in a stainless-steel tube, with the base of the tube submerged 10 mm below the seawater surface, and recorded the volumetric air flow 30 times using a flow meter (Gillibrator 2, Sensidyne, USA). Using these estimates of air entrainment, , we can estimate the particle production rate (per cubic metre) as follows:
5
The size-resolved interfacial flux is then obtained by multiplying the particle production rate by a parameterization of the air entrainment flux : 6
2.7.4 Derivation of SSA production fluxes by scaling size-resolved chamber measurements to ambient fluxesCombining EC flux measurements with chamber measurements enables us to estimate the sea spray source across the full particle size range. To achieve this, we compared the aerosol number concentration () measured in the sea spray simulation chamber across WELAS size bins () with the vertical aerosol number flux () from the EC flux system over size bins () and obtained a scaling factor. Because the WELAS operating on the sea spray chamber and the Grimm OPC-measuring EC fluxes on the tower are different and operate using different size bins, we interpolated the WELAS data to the EC flux OPC data range ( ) using the MATLAB spline function. This enabled us to estimate the ratio () of the EC flux to the concentration of particles measured in the sea spray simulation chamber (SSSC):
7 where has the unit metre per second.
It is important to note that the particles produced in the chamber experiments were dried before being sized and counted by DMPS and WELAS, while the EC flux OPC measured particles at ambient RH . For comparability, we have converted all diameters to radii at RH and referred to them as , unless explicitly stated otherwise. We used only the flux measurements obtained simultaneously with the chamber experiments to scale the chamber data.
3 Results and discussion3.1 Synoptic-scale and micro-meteorological overview
Figure displays a time series of micro-meteorological and synoptic parameters including wind speed, direction, friction velocity, air temperature, and RH as well as ambient aerosol concentrations and net fluxes from all the sectors. The fluxes from the coastal-influenced sector, which were excluded from the analysis, are indicated in grey. Upward aerosol fluxes dominated during both campaigns, with 491 half-hour periods being dominated by upward aerosol fluxes and 157 half-hour periods being dominated by downward aerosol fluxes across both campaigns.
Figure 2
Time series of relevant micro-meteorological and aerosol parameters for the Oceania and Electra campaigns. Panel (a) displays wind speed and direction as well as the friction velocity for the Oceania campaign. Panel (b) displays air temperature and relative humidity for both campaigns. Panel (c) shows the ambient particle concentration () and net fluxes measured on Östergarnsholm during the Oceania campaign. Panels (d) to (f) show the same parameters as panels (a) to (c) but for the Electra campaign.
[Figure omitted. See PDF]
Table provides an overview of synoptic-scale atmospheric and seawater properties, including wind speed and direction, fetch, atmospheric pressure, air and seawater temperature, salinity, concentration of dissolved oxygen, and chlorophyll in seawater, during the two campaigns. Frequency histograms of these parameters for both campaigns are also presented in Figs. S4 and S5. Additionally, wind roses of the prevailing wind directions and wind speeds during both campaigns are shown in Fig. S6. Measurements at the site indicated that, during both campaigns, the air mainly came from the west to south-west, accounting for 85 of the measurement time. Back-trajectories with endpoint heights at 100 m were computed using the HYSPLIT model for both campaigns and are presented in Figs. S7 and S8.
Table 1Overview of synoptic-scale atmospheric and seawater properties during the two campaigns, presented as the mean and standard deviation of values.
Atmospheric parameters | |||||
---|---|---|---|---|---|
(C) | RH () | (m s) | WD () | (hPa) | |
Oceania campaign, May | 10.4 1.4 | 80.6 9.9 | 6.4 1.9 | 229 53.8 | 1002 3.3 |
Electra campaign, August | 17.4 1.6 | 80.6 8.0 | 6.6 2.7 | 250.7 44.4 | 1003 7.4 |
Seawater properties | |||||
(C) | (g kg) | DO ( L) | CHL (mg m) | Fetch (km) | |
Oceania campaign, May | 9.8 0.4 | 7.0 0.01 | 379 15.8 | 3.9 0.3 | 264 264 |
Electra campaign, August | 18 1.1 | 6.7 0.1 | 282 3.6 | 5.2 1.1 | 188 298 |
During periods with southerly winds, the distance the sampled air mass spent above open water ranged from 500 to 1200 km, with the highest values observed during the Electra campaign. The local wind speed (averaged over 30 min intervals) ranged from 0 to 14 m s but was mostly between 4 and 10 m s (see Fig. and Table ). A clear seasonal increase in seawater and air temperature was observed between May and August. As a proxy for phytoplankton biomass, chlorophyll (CHL) was used. The Oceania campaign in May fell between the spring and summer blooms, while the Electra campaign in August coincided with the late stages of the summer bloom. Therefore, it is not surprising that higher levels of chlorophyll were measured during the Electra campaign (see Table ).
Table and the histograms in Fig. S9 provide an overview of the micro-meteorological conditions encountered during both campaigns in the open-sea sector. The mean stability was close to neutral during both campaigns with values of 0.02 0.18 during the May campaign and 0.06 0.12 during the August campaign. Stability affects the turbulent exchange of heat and water vapour, where unstable conditions lead to enhanced turbulence and stable conditions suppress turbulent exchange (see also , for stratification characteristics). This is also reflected in the latent and sensible heat fluxes. Sensible heat fluxes in the open-sea sector were close to zero during the May campaign (0.22 10.1 W m) and upward during the August campaign (7.02 14.14 W m). The latent heat fluxes were higher in August than in May (11.9 13.9 W m in the open-sea sector in May compared to 41.1 21.6 W m in August), which can be explained by increased evaporation as a result of higher seawater temperatures in August. Similar patterns in stability and latent or sensible heat exchange have previously been observed at Östergarnsholm . The mean friction velocity for the open-sea sector was 0.21 m s during the May campaign and 0.26 m s during the August campaign, which agrees well with the measurements reported in . Since variations in micro-meteorological parameters in the open-sea sector were small between the two campaigns (except for the heat fluxes), we have combined these datasets in the analysis that follows.
Table 2Overview of the micro-meteorological conditions encountered during both campaigns in the open-sea sector (80–220). The values are presented as a mean and standard deviation. The table includes sensible heat flux , latent heat flux , neutral drag coefficient (CD), wave age (), and significant wave height ().
CD | ||||||||
---|---|---|---|---|---|---|---|---|
() | (W m) | (W m) | (m s) | (m) | () | () | (m) | |
Oceania campaign | 0.02 | 0.22 | 11.88 | 0.21 | 9.85 | 1.2 | 1.12 | 0.59 |
0.18 | 10.10 | 13.94 | 0.09 | 7.62 | 1.3 | 0.47 | 0.24 | |
Electra campaign | 0.06 | 7.02 | 41.11 | 0.26 | 1.44 | 1.2 | 0.99 | 0.85 |
0.12 | 14.14 | 21.6 | 0.1 | 9.09 | 3.7 | 0.32 | 0.34 |
A description of the diurnal cycles of the ambient aerosol concentration and fluxes, as well as the micro-meteorological parameters and seawater properties mentioned above, is also provided in Sect. S1 in the Supplement.
3.2 Ambient aerosol concentrations and fluxesIn total, we obtained 648 half-hour estimates of the net aerosol flux by combining the data from the two campaigns, of which 386 originated from the open-sea sector. After excluding data periods characterized as non-ideal or poor, based on spectral quality control and data points when the ships were not located close to the station, we were left with 203 half-hour periods.
Figure S1b shows the size-resolved aerosol net fluxes () before and after applying all corrections. Additionally, it shows the aerosol emission flux derived from the corrected net aerosol flux after subtracting the aerosol dry deposition flux.
As shown in Table , the median uncorrected net flux was m s, which increased to m s after applying all the corrections. The estimated median total dry deposition flux was m s, several orders of magnitude lower than the SSA emission flux ( 1 %), which was estimated to be m s (median of the integrated fluxes across all OPC size bins). However, the dry deposition is still significant for the largest size bins. Previous studies over the open sea have estimated deposition fluxes of between 14 and 30 of the net flux .
Table 3
The table presents the median values of the uncorrected and fully corrected net aerosol number fluxes, along with the systematic and random aerosol errors. In addition, the table shows the modelled aerosol dry deposition flux and the estimated emission flux. The OPC bins are labelled as .
Aerosol EC flux | Symbol | Magnitude | Relative error or correction | Notes |
---|---|---|---|---|
(median) | (median) | |||
Unit | m s | |||
Uncorrected OPC EC flux, size-resolved | 1.1 () to 0 () | – | ||
Total | 1.9 | – | ||
Corrected OPC EC flux, size-resolved | 1.52 () to 7 () | – | ||
Total | 2.5 | |||
Aerosol EC flux errors | ||||
Systematic flux errors (positive values correspond to underestimated fluxes and positive corrections) | ||||
Fluctuation attenuation | 1.43 () to 0 () | 14.8 % | ||
in the sampling line | ||||
Losses due to the limited response time | 1.26 () to 0 () | 13.3 | ||
Particle losses in the sampling line | 6.35 () to 0.03 () | 0.6 () to 1.5 () | Size-dependent, | |
Webb correction | 1.47 () to 0.00 () | 5.3 () to 0 () | Size-dependent | |
Random flux errors | ||||
Overall random error | – | 35 %–42 % | Estimated | |
Discrete counting error | 6.66 () to 4.4 () | 2.8 () to 3 (), maximum 12.9 () | Size-dependent | |
Dry deposition flux | 7.23 () to 2.75 () | 0.24 () to 0.5 () | Size-dependent | |
Emission estimate, size-resolved | 2.3 () to 4.5 () | – | ||
Total | 2.9 |
Similar to a previous study in this region , the correction for aerosol losses in the sampling line and the correction that accounts for dry deposition fluxes had only minor impacts on total and size-resolved fluxes. This is likely because the OPC mostly samples the accumulation mode, where deposition in sampling tubes or surfaces within the flux footprint is minimal.
3.2.1 Dependence of aerosol net fluxes on the micro-meteorologyThe correlations between the measured net aerosol fluxes and micro-meteorological parameters, such as drag coefficient, roughness length, friction velocity, stability, sensible and latent heat flux, as well as turbulent kinetic energy, are shown in Fig. . The net aerosol fluxes demonstrate positive correlations with the wind speed, roughness length, friction velocity, turbulent kinetic energy, significant wave height, and wave Reynolds number and a negative correlation with wave age. In the following sections, we will focus on the dependence of the emission flux on the wind speed , significant wave height , and wave Reynolds number , which was calculated based on ( represents the viscosity of water and was calculated for the average seawater temperature and salinity encountered during this study).
Figure 3
Scatterplots of the net aerosol flux from the open-sea sector with (a) wind speed , (b) wind direction, (c) drag coefficient CD, (d) roughness length , (e) friction velocity , (f) stability , (g) sensible heat flux , (h) latent heat flux , (i) turbulent kinetic energy, (j) wave age, (k) wave height, and (l) wave Reynolds number. The grey dots show all the data points, and the blue lines show binned data. The correlation coefficients and levels of significance for each parameter with the EC flux are given in each panel.
[Figure omitted. See PDF]
3.2.2 Dependence of aerosol emission fluxes on wind speedAs shown in Fig. a, the SSA emission fluxes exhibit a logarithmic increase with a linear increase in wind speed:
8 which is consistent with the findings of many previous studies .
Figure 4
SSA emission flux versus (a) wind speed m s, (b) significant wave height, and (c) wave Reynolds number. The grey dots represent the 30 min emission fluxes, while the blue lines represent binned data (mean and standard deviation) and the orange lines represent fits to the individual 30 min data periods. Additionally, we compare our results to those from previous studies.
[Figure omitted. See PDF]
We have included the fit for the relationship between wind speed and net flux from a coastal site in the Baltic Sea reported in for comparison.
Factors such as aerosol dry deposition fluxes, boundary layer height, salinity, seawater temperature, fetch, sea ice fraction, seawater depth, wave field, and the presence of surfactants at the seawater surface can affect the slope and intercept of the fit in Fig. a. Furthermore, the fit parameters are dependent on particle size. Figure S10 shows that a log-linear relationship between SSA fluxes and wind speed can also be observed in each separate size bin of the OPC. The slopes , intercepts , and coefficients of determination for the size-resolved SSA emission fluxes are presented as a function of aerosol size in Fig. S11. The change in slope with size provides an estimate of the number of additional particles per surface area and second that are emitted for the same change in wind speed, with the highest increase observed for particle diameters between 0.3 and 1 , where the correlation coefficients are highest. Since particles of this size likely originate as film drops, this indicates that film drop production is potentially more sensitive to changes in wind speed than jet drop production under the conditions in which our measurements were made. When comparing the fits of the separate size bins to the findings from , we note a reasonable agreement with the slopes of the fits observed in their study except for the largest size bin.
3.2.3 Dependence of aerosol emission fluxes on wave propertiesFigure b and c present a comparison between the aerosol emission and two wave parameters, significant wave height and wave Reynolds number . Binning the data into regularly distanced intervals based on the median values reveals trends. The emission flux shows a power-law increase with increasing significant wave height, which is similar to the relationship reported by (although their emission flux was more than an order of magnitude higher since they used a CPC to measure the SSA emission fluxes for particles nm). Additionally, there is a linear increase in the emission flux with increasing wave Reynolds number, which agrees very well with the parameterizations by and .
In their study, observed that higher values of and resulted in higher size-resolved aerosol emission fluxes across all the aerosol sizes ( ). The effect was found to be stronger for than for . In Fig. we present our own findings on how size-resolved aerosol emission fluxes depend on , , and and compare them to the results of . Note that we did not include the data from in Fig. since their flux measurements were several orders of magnitude higher than ours, likely for the reasons outlined earlier.
We found that our sea spray aerosol emissions, like those reported by , are strongly influenced by the significant wave height . Specifically, we observed a significant difference in size-resolved aerosol fluxes of a factor of 1–3 depending on the size bin (at a probability value of and at a significance level of 5 ) for m and m. Similarly, the data from differed by a factor of 1–5 for the same wave height ranges. Moreover, for wind speeds m s and m s, we found a difference in aerosol flux of more than an order of magnitude (at a probability value of and at a significance level of 5 ), while reported a much smaller difference, even over a wider range of .
Finally, from Fig. c, it is apparent that the wave Reynolds number strongly affects the size-resolved aerosol emission fluxes that we observed. In this regard, our dataset exhibits a similar trend compared to the parameterization of .
Figure 5
Size-resolved emission flux dependence on (a) wind speed, (b) significant wave height, and (c) wave Reynolds number compared to the parameterization from . Values are presented as a mean and standard deviation.
[Figure omitted. See PDF]
3.3 Simulated sea spray production in the chamber experiments with water from the footprint areaFigure shows a time series of the particle concentration measured in the headspace of the sea spray simulation chamber as well as flux estimates derived from the entrainment method from the continuous whitecap method and from scaling the chamber data to in situ fluxes. The figure also includes seawater properties such as seawater temperature, salinity, chlorophyll , and dissolved oxygen, which were monitored during both the Oceania and Electra campaigns. Periods when the research vessels were not anchored close to the station were excluded, while periods when the wind was blowing from outside the open-sea sector are shaded.
Figure 6
Time series of various measurements from the sea spray simulation chamber during the Oceania and Electra campaigns. Panel (a) displays the particle concentration measured in the headspace of the sea spray simulation chamber, along with flux estimates derived from the entrainment method, the continuous whitecap method, and scaling the chamber data to the in situ fluxes. Shaded periods indicate when the ship was not anchored close to Östergarnholm or when the wind was blowing from outside the open-sea sector. Panels (b) and (c) show the seawater temperature and salinity and the concentrations of chlorophyll and dissolved oxygen for the Oceania campaign, respectively. Panels (d–f) display the same measurements as panels (a–c) but for the Electra campaign.
[Figure omitted. See PDF]
When contrasting the data between the two campaigns, it is crucial to highlight that the experiments conducted in the Oceania campaign involved a higher plunging jet flow rate (3.5 L min as opposed to 1.3 and 2.6 L min during the Electra campaign). Consequently, this resulted in elevated particle concentrations recorded during the Oceania campaign. The sudden increase in particle concentration on 14 August was due to an increase in the plunging jet flow rate from 1.3 to 2.6 L min. Another factor that may have contributed to the higher particle concentration measured during the Oceania campaign is the lower seawater temperatures in May (around 10 C) compared to August (around 17 C). Previous studies have observed an increase in particle production at lower seawater temperatures
Salinity was fairly constant during both campaigns (6.4–7 g kg). As the solubility of oxygen in water decreases with increasing temperatures, it is not surprising that the dissolved oxygen concentrations during the May campaign were higher than during the August campaign. Additionally, the concentration of chlorophyll was higher during the August campaign. Chlorophyll is often used as a proxy for biological productivity, which in turn can influence the concentration of dissolved oxygen through photosynthesis and respiration.
Figure S12 shows the mean number size distribution and total concentration of SSA particles in the headspace of the sea spray simulation chamber measured by DMPS and WELAS at different jet flow rates during both campaigns. It is evident from this comparison that the total number of particles produced in the sea spray chamber increased with an increasing jet flow rate, while the size distribution remained constant at each respective jet flow rate, with a mode centred at 100 nm and a second mode with a smaller magnitude centred at 500 nm. This aerosol size distribution is similar to the size distribution of inorganic sea salt measured with the same experimental set-up at g kg .
For the range of particle sizes where both DMPS and WELAS conducted measurements with a 100 counting efficiency (i.e. between 0.3 and 0.8 dry diameter), the measurements were found to be in good agreement. This justifies our decision to combine the data from the two instruments at a dry diameter of 0.35 .
In a previous study, used a sea spray simulation chamber that was similar to the one used in this study but smaller. They also continuously replaced the seawater in their chamber with fresh local seawater and observed a dependence of the SSA size distribution measured in the headspace of their chamber on wind speed and dissolved oxygen concentration. Following their example, we investigated whether wind speed and dissolved oxygen saturation could potentially influence the size distribution and overall concentration of SSA produced in our chamber. To do so, we binned the data into three wind categories (0–5, 5–10, and 10 m s) and with respect to dissolved oxygen into subsaturated (DO), saturated (), and supersaturated () seawater.
In contrast to , we observed no significant differences in the size-resolved particle concentration at different wind speeds ( at a significance level of 5 ) or varying DO saturations ( at a significance level of 5 ) (see also Figs. S13 and S14). We only observed a weak positive correlation between wind speed and total particle concentration for the Electra campaign (, at L min and , at L min) but no significant correlation for the Oceania campaign (, ). Moreover, we observed only a weak negative correlation between the total particle concentration in the headspace of the simulation chamber and the concentration of chlorophyll in the seawater (, at L min and , at L min) and a weak positive correlation between the total particle concentration in the headspace of the simulation chamber and the concentration of FDOM in the seawater (, at L min and , at L min) during the Electra campaign. Unfortunately, we did not have sufficient data points of chlorophyll and FDOM concentration for the Oceania campaign to derive a correlation. Scatterplots for these parameters versus particle concentration are shown in Fig. S15.
3.4 Scaling the sea spray simulation chamber measurements to aerosol emission fluxesWe used three different approaches to convert the particle concentration measured in the headspace of the simulation chamber to emission fluxes. The first approach involved using the CWM (described in detail in Sect. ), while the second approach used air entrainment measurements to derive SSA emission fluxes (explained in Sect. ). The third approach, which we adapted from , involved scaling the particle concentrations measured in the simulation chamber headspace to the in situ emission fluxes in the particle size range where both the WELAS and Grimm OPC used in the EC flux system conducted measurements (detailed in Sect. ).
To calculate the average scaling factor for all size bins , it is necessary to have a similar slope between the chamber headspace number size distribution over and the flux distribution over . To test for this similarity, we conducted a Kolmogorov–Smirnov test on the particle size range . The test revealed that the slopes were not significantly different at a probability value of and at a significance level of .
Scaling the sea spray simulation chamber data to the in situ fluxes we measured in this study allowed us to scale the concentration of any scalar measured in the sea spray simulation chamber air to the emission fluxes EF using the following equation:
9
Examples of this could include the mass emission of compounds collected on filters connected to the sea spray simulation chamber or the number of sampled bacteria. Using this scaling factor, they could be scaled to mass emission (g m s) or number emission fluxes (bacteria cells m s).
It is important to note that the scaling factor is specific to each sea spray simulation chamber and cannot be applied to another chamber, as the experimental set-up will vary depending on factors such as the flow rate of the plunging jet and the chamber dimensions.
Since we used different plunging jet rates during the Oceania campaign (3.5 L min) and the Electra campaign (1.3 and 2.6 L min), we had to derive separate scaling factors for each jet flow rate. Figure S16 shows how the scaling factor depends on the jet flow rate. Furthermore, since in situ fluxes were measured at ambient RH ( 80 % on average), while particles produced in the chamber were dried before being measured, we have converted all the diameters to radii at RH 80 .
Despite the good agreement of the slopes in , we would like to draw the reader's attention to the disparity between the emission fluxes derived from in situ measurements and the scaled chamber data at . At , the scaled chamber data yield emission fluxes that are higher than the emission fluxes derived from in situ measurements. Since the EC method provides a direct measurement of the fluxes, those measurements should be considered more realistic. We cannot entirely exclude the possibility of wall effects in the chamber experiments, particularly at high jet flow rates. In an ideal sea spray simulation chamber, all the bubbles would burst without interacting with the chamber walls. However, in the current study, although the dimensions of the chamber are such that most bubbles burst without interacting with the walls, some bubbles are likely to have been influenced by the walls. One possible effect of these wall interactions is that the lifetime of bubbles interacting with the walls is reduced. Simply put, they burst upon impact with the walls instead of remaining on the water surface, potentially reducing the coalescence of bubbles at the water surface. It is possible that reduced coalescence would cause bubbles to burst when they are slightly smaller but more numerous than if there were no walls and the bubbles were allowed to coalesce and form larger but fewer bubbles. It is more difficult to ascertain, however, how this effect could impact the size and number of the aerosols produced. Furthermore, it should be considered that the EC measurements were also impacted by sea spray production history, such as the impact of fetches and water depth. On the other hand, the seawater in the sea spray simulation chamber is purely local, which might introduce additional uncertainty when merging the two datasets.
Figure compares the fluxes derived from chamber experiments using the continuous whitecap method, air entrainment measurements, and simple scaling with the EC fluxes measured on the island of Östergarnsholm. The fluxes obtained from the scaled chamber data agree well with the flux estimates from the entrainment method and the whitecap method.
Figure 7
Comparison of the mean in situ aerosol emission fluxes measured on the island of Östergarnsholm with simulation chamber measurements that are scaled to the mean emission flux derived from both campaigns, together with the fluxes estimated using the continuous whitecap method and air entrainment measurements. The scaled fluxes from the chamber measurements are presented as a mean with a standard error, while the EC-derived aerosol emission fluxes are presented as a mean with a random error and a discrete counting error. For comparison, EC-derived aerosol fluxes from and SSA parameterizations from and are also included.
[Figure omitted. See PDF]
3.5 Comparison of scaled chamber data and in situ emission fluxes to previous studiesFigure also illustrates the comparison between the scaled chamber fluxes, in situ emission fluxes, and existing sea spray parameterizations by and ( m s and C). Both parameterizations show reasonably good agreement with the in situ data, with slightly higher values from the Mårtensson parameterization and slightly lower values from the Salter parameterization. These parameterizations were derived from chamber experiments with artificial seawater at salinities of 33 and 35 g kg, respectively. However, reported an increase in aerosol particle production at lower salinities (6–8 g kg) relevant to the Baltic Sea, where these measurements were conducted, compared to higher salinities ( 35 g kg). The authors attributed this to an increased number of large bubbles at lower salinities, which tend to produce numerous small film drops. The only previous sea spray aerosol flux measurements from the Baltic Sea were conducted by , which show emission fluxes that agree well with the emission fluxes derived from this study.
In their study, attempted to scale co-located chamber experiments to EC flux measurements using the same approach employed in the current study. However, they were unable to derive a scaling factor between the chamber measurements and in situ fluxes due to differences in the slopes of the size distributions resulting from both methods. This discrepancy may have been due to the inclusion of fluxes obtained from sectors with short fetches and shallow waters. The success of the current dataset in this regard is likely attributed to the use of a large, homogeneous dataset that is clearly defined as open sea with a long fetch.
3.6 Wind-speed- and wave-state-dependent parameterizations of the scaled chamber data
In Sect. and , we discussed the dependence of SSA emission fluxes on both wind speed and wave state. In this section, we have developed parameterizations of the aerosol emission flux as a function of wind speed and wave Reynolds number, which takes into account wave height, friction velocity, and seawater viscosity, which in turn depends on seawater temperature and salinity. Both parameterizations are valid for seawater temperatures between 10 and 20 C and salinities between 6 and 7 g kg, which represent large parts of the Baltic Proper during the summer half of the year. We used scaled chamber data that encompass dry particle diameters as a basis for the parameterizations. To parameterize the emission flux, we fit the scaled chamber data (binned based on wind speed or wave Reynolds number) to the sum of three log-normal distributions of the form
10
In the wind-speed-dependent parameterization, the magnitude of each mode is parameterized by a log-linear relationship. For the wave-state-dependent parameterization, we adopted a similar approach to that used by . Table provides the modal diameters (), geometric standard deviations (), and log-linear relationships for the magnitude EF for each mode. Figures S17 and S18 illustrate how the derived relationships fit the modes of the scaled chamber data with increasing wind speeds and wave Reynolds number, respectively.
Figure 8
Comparison of the wind-speed- and wave-state-dependent parameterizations derived from this study with those from studies, including , , and . Panel (a) shows emission estimates at 10 m s, while panel (b) shows the estimated mass emission flux for particles with dry diameters , which is the range in which the parameterization is valid. The wave-state-dependent parameterization is based on averaging the wave Reynolds number within the corresponding wind speed bins and using these mean wave Reynolds number values as the foundation for the parameterization.
[Figure omitted. See PDF]
Table 4The modal diameters , geometric standard deviations (), and log-linear relationships for the number fluxes (EF) of each of the three log-normal modes in the parameterization derived in this study.
EF | EF | |||
---|---|---|---|---|
Mode 1 | 0.095 | 2.6 | ||
Mode 2 | 0.5 | 1.72 | ||
Mode 3 | 1.3 | 1.75 |
Figure shows that the wind-speed-dependent parameterization derived in this study produces size-resolved number emission fluxes and mass emission estimates that agree well with those obtained from the parameterizations by , , and . Although recent studies suggest that sea state is a better predictor of SSA emissions than wind speed alone , our wave Reynolds number-dependent parameterization yields lower mass emission fluxes than the wind-speed-dependent parameterizations, particularly at wind speeds above m s. When compared to the mass estimates from the in situ EC flux measurements over the measured size range (see Fig. S19), these agree very well for wind speeds m s but deviate for higher wind speeds. The parameterizations by , , and were developed for high-salinity conditions. Thus, it is reasonable to expect lower mass production in the sea spray simulation chamber at lower salinities ( g kg), such as those encountered in the Baltic Sea . To the best of our knowledge, prior studies have not specifically examined the influence of lower salinity on wave-breaking patterns. However, this factor could potentially elucidate some of the disparities observed between our flux estimates and those conducted in higher-salinity waters.
4 Summary and conclusionIn this study, we compared SSA production fluxes derived from sea spray simulation chamber measurements and in situ EC fluxes measured close to the ICOS station on the island of Östergarnsholm during two ship-based campaigns in May and August 2021. By combining these datasets, we quantified the magnitude and size-resolved spectrum of SSA fluxes using fast EC flux measurements across the full range of particle sizes relevant for SSA emissions. During the two campaigns, we observed a log-linear relationship between the total in situ emission fluxes and wind speed, a power-law relationship between the total emission fluxes and significant wave height, and a linear relationship between the total emission fluxes and wave Reynolds number, similar to what has been reported in several previous studies. In contrast, we did not observe any significant impact of wind speed or dissolved oxygen concentration on the size-resolved particle production in the sea spray simulation chamber experiments, as reported in previous studies. We only observed a weak negative correlation between the particle production and the concentration of chlorophyll together with a weak positive correlation between the particle production and the concentration of FDOM in the seawater.
We were able to scale the chamber measurements at three different jet flow rates to obtain realistic emission fluxes using three different approaches: (1) the continuous whitecap method, (2) measurements of air entrainment, and (3) scaling the chamber measurements to the in situ emission fluxes. The measured in situ fluxes and scaled chamber data also agreed well with previous flux measurements from the Baltic Sea and the parameterizations by and .
Finally, we derived wind-dependent and wave-state-dependent parameterizations of SSA emissions at low salinities representative of the Baltic Proper. The number and mass emission estimates derived from the wind-speed-dependent parameterization are in good agreement with previous studies, while the wave-state-dependent parameterization yields lower mass emission estimates. We attributed this difference to the lower salinity of the Baltic Sea and the fact that the Baltic Sea is a semi-enclosed sea and might not always be representative of open-ocean conditions.
The combination of laboratory experiments and EC measurements in this study is crucial for understanding how well laboratory estimates of SSA emission fluxes represent in situ emission fluxes. This has significant implications for several reasons. Laboratory estimates of SSA emission fluxes cover the entire range of aerosol particle sizes produced by bursting bubbles. However, the accuracy of laboratory systems in replicating the wave-breaking process is still uncertain. Nevertheless, the reasonably good agreement between laboratory emission estimates using the air entrainment scaling and the in situ fluxes suggests that this approach can provide realistic estimates of SSA production. Secondly, certain aerosol types and properties cannot be effectively measured at the high frequencies required for EC measurements. For instance, the EC approach is inadequate for accurately estimating bacteria fluxes from the ocean to the atmosphere. On the other hand, laboratory systems are capable of measuring bacteria fluxes. Therefore, combining laboratory measurements with EC measurements allows us to derive realistic estimates of bacteria flux.
Based on these findings, our future work will involve utilizing multi-year EC measurements to investigate seasonal cycles in SSA emission fluxes from a coastal site in the Baltic Sea. Our focus will be particularly on emissions of bioaerosols contained within SSA. By integrating measurements from both the laboratory sea spray chamber and EC techniques, our aim is to develop a comprehensive understanding of SSA fluxes and the environmental factors influencing them.
Appendix A Loss estimates and systematic error corrections
A1 Systematic errors
A1.1 Losses in aerosol fluxes due to the limited response time of the OPC
To accurately measure EC fluxes, instruments must have a time resolution of 10–20 Hz to capture the smallest eddies. However, some instruments like OPCs are unable to achieve this resolution, resulting in significant flux attenuation. To correct for this, we used the equations for the atmospheric surface layer from . By solving the integral of transfer functions and co-spectra analytically, they derived the flux attenuation () as follows:
A1
Here is the ideal flux that would have been measured if the sensor response time was not too long (where is either or ), is the dimensionless frequency at the co-spectral maximum and is a function of atmospheric stability, is the instrument's first-order response time, and is the mean wind speed at measurement height . Here for stable stratification and for neutral and unstable stratification. The normalized frequency can be estimated for stable stratification () as follows: A2
For neutral and unstable conditions, . The first-order response time should be determined experimentally following and . determined to be 0.3 s for the Grimm 1.109 OPC. This allows us to calculate the systematic error of the limited response time as A3
Therefore, the corrected flux is A4
A1.2 Fluctuation attenuation due to air transport in the tubes of closed-path systemsAttenuation of turbulent fluctuations in the sampling tube causes an underestimation of the EC flux (). Co-spectral power frequency transfer functions can be used to estimate the corresponding loss of particle fluctuations in laminar flow . Following and , we used a first-order response time of 0.4 s to estimate the damping in the sampling lines and the OPC, which will be described in detail in the next section. The aerosol EC fluxes were corrected as follows:
A5
A1.3 Aerosol particle losses within the sampling lineParticle losses due to Brownian diffusion, impaction, interception, and sedimentation in the sampling line were estimated using a program written by . Since the OPC mostly measures particles in the accumulation mode, Brownian diffusion was small within the OPC range. The sampling lines were arranged vertically to minimize deposition losses. Therefore, the corrected aerosol flux for each size bin is
A6 where is the corrected size-dependent tube particle losses, and the corrected total aerosol flux for the entire OPC size range is A7
A1.4 Webb correctionThe Webb correction , also known as the WPL correction after all three co-authors, is required because fluctuations in temperature and humidity can cause fluctuations in scalar concentrations that are not related to the trace gas flux to be measured. For a scalar , such as gas or particles, with an average concentration , the Webb correction can be written as
A8
Here, is the ratio of molar masses of dry air and water, is the dry air density, and is the average water vapour concentration or density. We applied this correction to both HO and CO fluxes calculated from the Licor7500, resulting in the corrected fluxes for CO and HO:
Temperature fluctuations in tubing with high thermal conductivity are reduced to 1 of their initial value when the tubing length-to-diameter ratio was for laminar flow and for turbulent flow . For our OPC, which has laminar flow, the ratio is approximately 787. Thus, for the OPC, we can simplify the Webb correction equation to A11
The corrected aerosol number flux or is now A12
A2 Random errorsA2.1 Discrete counting error of aerosol EC fluxes
The OPC operates by passing air flow through a laser mounted at a 90 angle to a photodiode. On the opposite side of the photodiode, there is a copper mirror that produces light reflection for the photodiode. Each size channel of the OPC has been calibrated separately in comparison to a reference instrument. When a particle passes through the laser, it creates a voltage spike in the photodiode. The height of this signal determines the particle size. Instruments like the OPC and CPCs count each particle discretely. For such instruments, a large part of the random errors is related to the discrete nature of the data. The error in the aerosol number concentration is proportional to , where is the total count per half-hour period, or , where L min is the sample flow of the OPC and is the sampling period. This is often called the discrete counting error or the square root counting error. When applied to or , the error expression (for either an individual size bin or the total OPC size range) becomes A13 where is the vertical wind variance .
Data availability
The data from this study are available at the Bolin Centre for Climate Research database at 10.17043/zinke-2023-baltic-emissions-1 .
The supplement related to this article is available online at:
Author contributions
EDN, JZ, MES, and PZ designed the experiments. EDN, PM, and EMM maintained the EC flux station. AR and EN prepared the buoy data and Licor data. JZ and PZ carried out the chamber experiments. The data analysis was conducted by JZ with the help of EDN and EMM. JZ, EDN, and MES prepared the manuscript with contributions from all the co-authors.
Competing interests
At least one of the (co-)authors is a member of the editorial board of Atmospheric Chemistry and Physics. The peer-review process was guided by an independent editor, and the authors also have no other competing interests to declare.
Disclaimer
Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.
Acknowledgements
The ICOS station at Östergarnsholm is maintained by Uppsala University and VR. The Institute of Oceanology, at the Polish Academy of Science, enabled us to use their research vessel, Oceania, anchoring the ship near Östergarnsholm for several days to conduct our sea spray simulation experiments aboard the ship, close to the aerosol flux tower at Östergarnsholm. Furthermore, we thank the crew and captain of R/V Oceania and R/V Electra and the technical staff at ACES, Stockholm University, for their support. We are grateful to Marcin Stokowski for sharing the CTD and dissolved oxygen data for the Oceania cruise with us. The wave data were kindly provided by Heidi Pettersson from the Finnish Meteorological Institute (FMI). We also acknowledge the NOAA Air Resources Laboratory (ARL) for providing the HYSPLIT transport and dispersion model and the READY website (
Financial support
The CROISSANT project is financed by the Swedish Research Council project 2018-04255. The aerosol flux tower and system were financed initially by FORMAS, project no. 2007-1362, and have since received contributions from several FORMAS and VR projects. This research was also supported by the Polish National Agency for Academic Exchange under the Bekker Program (Decision PPN/BEK/2019/1/00043/DEC/1) and VR under project 2016-05100. The research is also supported financially by the Bolin Climate Centre at Stockholm University and logistically by Uppsala University. The article processing charges for this open-access publication were covered by Stockholm University.
Review statement
This paper was edited by Matthias Tesche and reviewed by Mingxi Yang and two anonymous referees.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2024. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
To compare in situ and laboratory estimates of sea spray aerosol (SSA) production fluxes, we conducted two research campaigns in the vicinity of an eddy covariance (EC) flux tower on the island of Östergarnsholm in the Baltic Sea during May and August 2021. To accomplish this, we performed EC flux measurements for particles with diameters between 0.25 and 2.5
To obtain an estimate of the size-resolved emission spectrum for particles with dry diameters between 0.015 and 10
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details






1 Department of Environmental Sciences, Stockholm University, Stockholm, Sweden; Bolin Centre for Climate Research, Stockholm University, Stockholm, Sweden
2 Department of Environmental Sciences, Stockholm University, Stockholm, Sweden; Bolin Centre for Climate Research, Stockholm University, Stockholm, Sweden; Institute of Oceanology, Polish Academy of Science, Sopot, Poland
3 Department of Environmental Sciences, Stockholm University, Stockholm, Sweden; Department of Earth Sciences, Uppsala University, Uppsala, Sweden
4 Department of Earth Sciences, Uppsala University, Uppsala, Sweden