It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Aims
It is unclear whether activated partial thromboplastin time (aPTT) or anti‐Xa is more accurate for monitoring heparin anticoagulation in mechanical circulatory support (MCS) patients. This study investigates the relationship between aPTT and anti‐Xa in MCS patients and identifies predictors of discordance.
Methods and results
aPTT and anti‐Xa were simultaneously measured in a prospective cohort of MCS patients receiving unfractionated heparin at a tertiary academic medical centre. Therapeutic aPTT and anti‐Xa levels were 60–100 s and 0.3–0.7 IU/mL, respectively, and concordance was defined as both levels being subtherapeutic, therapeutic, or supratherapeutic. To identify predictors of discordance, both a machine learning random forest model and a multivariate regression model were applied to patient demographics, device type, and 14 laboratory variables; 23 001 pairs of simultaneously measured aPTT/anti‐Xa were collected from 699 MCS patients. aPTT and anti‐Xa were concordant in 35.5% of paired observations and discordant in 64.5% (aPTT > antiXa 61.5%; aPTT < antiXa 3.0%). Discordance with a high aPTT relative to anti‐Xa (aPTT > antiXa) was associated with high INR, eGFR, and total bilirubin, as well as low platelets, haemoglobin, pre‐albumin, white blood cell count, and haptoglobin. Total artificial heart and durable ventricular assist devices were more likely to be associated with aPTT > anti‐Xa than temporary MCS devices.
Conclusions
aPTT and anti‐Xa were frequently discordant in MCS patients receiving heparin anticoagulation. Clinical conditions common in MCS patients such as concurrent warfarin use, malnutrition, haemolysis, and thrombocytopenia, as well as durable type of MCS devices were associated with a high aPTT relative to anti‐Xa.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
; Li, Ang 2 ; Beckman, Jennifer A. 3 ; Kim, Christopher 3 ; Granich, Marian A. 3 ; Mondin, John 1 ; Sabath, Daniel E. 3 ; Garcia, David A. 3 ; Mahr, Claudius 1 1 Medical City Healthcare, Dallas, TX, USA
2 Division of Hematology & Oncology, Baylor College of Medicine, Houston, TX, USA
3 University of Washington, Seattle, WA, USA