Full Text

Turn on search term navigation

© 2024 by the authors. Published by MDPI on behalf of the Lithuanian University of Health Sciences. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background and Objectives: The steady spread of dengue virus (DENV) poses a profound public health threat worldwide. Reverse transcription real-time polymerase chain reaction (RT2-PCR) has been increasingly recognized as a reference method for the diagnosis of acute dengue infection. The goal of this study was to assess the diagnostic accuracy of five different RT2-PCR kits for the detection of DENV in a historically processed set of sera samples. Materials and Methods: In this retrospective study, 25 sera samples from routinely processed unique adult patients with a known DENV status (previously tested in both molecular and serological assays) were tested in parallel using four conventional (RealStar Dengue PCR Kit 3.0, Clonit’ngo Zika, Dengue & Chikungunya, BioPerfectus Zika Virus/Dengue Virus/Chikungunya Virus Real Time PCR Kit and Novaplex Tropical fever virus) and one sample-to-result (STANDARD M10 Arbovirus Panel) RT2-PCR assays. Additionally, an end-point dilution analysis was conducted in quintuplicate on six serial dilutions of an RNA preparation obtained from a culture-grown DENV serotype 1 strain for a total of 150 tests. Results: The overall accuracy of the evaluated tests ranged from 84% to 100%. In particular, the sensitivity of three conventional RT2-PCR assays (RealStar, Clonit’ngo and Novaplex) was 100% (95% CI: 79.6–100%), while it was lower (73.3%; 95% CI: 48.1–89.1%) for the BioPerfectus kit. The sample-to-result STANDARD M10 panel performed comparatively well, showing a sensitivity of 92.9% (95% CI: 68.5–98.7%). No false positive results were registered in any assay. The end-point dilution analysis suggested that the RealStar kit had the lowest limit of detection. Conclusions: Available RT2-PCR kits for the detection of DENV are highly specific and generally sensitive and, therefore, their implementation in diagnostic pathways is advisable.

Details

Title
Diagnostic Accuracy of Five Molecular Assays for the Detection of Dengue Virus
Author
Scarpaleggia, Marianna 1   VIAFID ORCID Logo  ; Garzillo, Giada 1 ; Lucente, Miriana 2 ; Fraccalvieri, Chiara 2 ; Randazzo, Nadia 2 ; Massaro, Elvira 1 ; Galano, Barbara 2 ; Ricucci, Valentina 2 ; Bruzzone, Bianca 2 ; Domnich, Alexander 2   VIAFID ORCID Logo 

 Department of Health Sciences, University of Genoa, 16132 Genoa, Italy; [email protected] (M.S.); [email protected] (G.G.); [email protected] (E.M.) 
 Hygiene Unit, San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; [email protected] (M.L.); [email protected] (C.F.); [email protected] (N.R.); [email protected] (B.G.); [email protected] (V.R.); [email protected] (B.B.) 
First page
1557
Publication year
2024
Publication date
2024
Publisher
MDPI AG
ISSN
1010660X
e-ISSN
16489144
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3110577855
Copyright
© 2024 by the authors. Published by MDPI on behalf of the Lithuanian University of Health Sciences. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.