Abstract
Background
The study aims to investigate Shear Wave Elastography's accuracy in assessing pediatric cholestasis and differentiating biliary atresia from other causes. The early diagnosis of cholestasis in newborns, when caused by true liver disease and not physiological or transient jaundice is usually eluded. To maximize the diagnostic reliability of ultrasound as an initial imaging modality to diagnose biliary atresia, ultrasound elastography has been introduced as a quantitative non-invasive sonographic technique to measure liver stiffness which is presumed to be different in biliary atresia from other cholestasis as well as follow-up liver stiffness post-Kasai operation.
Results
Ten patients (34.48%) were diagnosed with cholestasis with normal/low GGT. Five patients (17.24%) were diagnosed with hepatitis, and 2 patients had syndromes (10.34%). Other causes were found in 11 patients (37.93%). Major bile duct obstruction with fibrosis/cirrhosis was the majority of findings found in biliary atresia patients (100%), most of them with mild fibrosis (40%), followed by moderate (36.67%), then marked fibrosis (13.33%) and secondary cirrhosis (10%). ROC curve analysis shows that the best cut-off value for SWE = 1.97 with a sensitivity of 75.0% and specificity of 83.5%, with positive and negative predictive values were 82.8% and 74.1%, respectively. Mean shear wave elastography was significantly higher among the biliary atresia group (median 2.86) than in non-biliary atresia (median 1.81) and control groups (median 1.64) (P < 0.001) The best cut-off value of shear wear elastography for predicting outcome in pediatric patients post-Kasai procedure was 3.55, with a sensitivity of 66.7%, specificity of 64.7%, positive and negative predictive values were 25% and 91.7% respectively, with accuracy 65%.
Conclusion
The results of this study suggest that shear-wave elastography is a useful diagnostic tool for differentiating biliary atresia from other causes of cholestasis in pediatric patients, with a high sensitivity and specificity. Further studies are needed to validate the findings and determine the optimal cut-off value for shear wear elastography in clinical practice.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Cairo University Hospitals, Diagnostic and Intervention Radiology Department, Cairo, Egypt (GRID:grid.476980.4)
2 Cairo University Hospitals, Gasteroenterology Unit, Pediatric Department, Cairo, Egypt (GRID:grid.476980.4)