This study presents a performance evaluation of eight Atmotube PRO sensors using US Environmental Protection Agency (US EPA) guidelines. The Atmotube PRO sensors were collocated side by side with a reference-grade Fidas monitor in an outdoor setting for a 14-week period in the city centre of Leeds, UK. We assessed the linearity and bias for PM1, PM2.5, and PM10. The result of the PM2.5 assessment showed the Atmotube PRO sensors had particularly good precision with a coefficient of variation (CoV) of 28 %, 18 %, and 15 % for PM2.5 data averaged every minute, hour, and day, respectively. The inter-sensor variability assessment showed two sensors with low bias and one sensor with a higher bias in comparison with the sensor average. Simple univariate analysis was sufficient to obtain good fitting quality to a Fidas reference-grade monitor (R2>0.7) at hourly averages, although poorer performance was observed using a higher time resolution of 15 min averaged PM2.5 data (R2 of 0.48–0.53). The average error bias, root mean square error (RMSE), and normalized root mean square error (NRMSE) were 3.38 µg m−3 and 0.03 %, respectively. While there were negligible influences of temperature on Atmotube PRO-measured PM2.5 values, substantial positive biases (compared to a reference instrument) occurred at relative humidity (RH) values > 80 %. The Atmotube PRO sensors correlated well with the PurpleAir sensor (R2 of 0.88, RMSE of 2.9 µg m−3). In general, the Atmotube PRO sensors performed well and passed the base-testing metrics as stipulated by recommended guidelines for low-cost PM2.5 sensors. Calibration using the multiple linear regression model was enough to improve the performance of the PM2.5 data of the Atmotube PRO sensors.

Details

Title
Performance evaluation of Atmotube PRO sensors for air quality measurements in an urban location
Author
Shittu, Aishah I 1 ; Pringle, Kirsty J 2   VIAFID ORCID Logo  ; Arnold, Stephen R 3   VIAFID ORCID Logo  ; Pope, Richard J 4 ; Graham, Ailish M 3   VIAFID ORCID Logo  ; Reddington, Carly 3   VIAFID ORCID Logo  ; Rigby, Richard 5   VIAFID ORCID Logo  ; McQuaid, James B 3   VIAFID ORCID Logo 

 Institute for Climate and Atmospheric Science, University of Leeds, Leeds, UK; Department of Science Laboratory Technology, Federal Polytechnic Ilaro, Ilaro, Nigeria 
 Software Sustainability Institute, Edinburgh Parallel Computing Centre, University of Edinburgh, Edinburgh, UK 
 Institute for Climate and Atmospheric Science, University of Leeds, Leeds, UK 
 School of Earth and Environment, University of Leeds, Leeds, UK; National Centre for Earth Observation, University of Leeds, Leeds, UK 
 Centre for Environmental Modelling And Computation, University of Leeds, Leeds, UK 
Pages
817-828
Publication year
2025
Publication date
2025
Publisher
Copernicus GmbH
ISSN
18671381
e-ISSN
18678548
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3166115523
Copyright
© 2025. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.