Abstract
Background
One major goal of total knee arthroplasty (TKA) is to achieve balanced medial and lateral gaps in flexion and extension. While bone resections are planned by the surgeon, soft tissue laxity is largely intrinsic and patient-specific in the absence of additional soft tissue releases. We sought to determine the variability in soft tissue laxity in patients undergoing TKA.
Methods
We retrospectively reviewed 113 patients undergoing TKA. Data on preoperative knee deformity were collected. Data from a dynamic intraoperative stress examination were collected by a robotic tracking system to quantify maximal medial and lateral opening in flexion (85–95 degrees) and extension (-5–20 degrees). T-tests were used to assess the differences between continuous variables.
Results
A valgus stress opened the medial compartment a mean of 4.3 ± 2.3 mm (0.0–12.4 mm) in extension and 4.6 ± 2.3 mm (0.0–12.9 mm) in flexion. A varus stress opened the lateral compartment a mean of 5.4 ± 2.4 mm (0.3–12.6 mm) in extension and 6.2 ± 2.5 mm (0.0–13.4 mm) in flexion.
The medial compartment of varus knees opened significantly more in response to valgus stress than valgus knees in both extension (5.2 mm vs. 2.6 mm; P < 0.0001) and flexion (5.4 mm vs 3.3 mm; P < 0.0001). The lateral compartment of valgus knees opened significantly more in response to varus stress than varus knees in both extension (6.7 mm vs. 4.8 mm; P < 0.0001) and flexion (7.4 mm vs. 5.8 mm; P = 0.0003).
Conclusions
Soft tissue laxity is highly variable in patients undergoing TKA, contributing anywhere from 0–13 mm to the post-resection gap. Only a small part of this variability is predictable by preoperative deformity. These findings have implications for either measured-resection or gap-balancing techniques.
Level of Evidence
Level III.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer