Background
Rebound hyperglycemia may occur following glucagon treatment for severe hypoglycemia. We assessed rebound hyperglycemia occurrence after nasal glucagon (NG) or injectable glucagon (IG) administration in patients with type 1 diabetes (T1D) and type 2 diabetes (T2D).
Methods
This was a pooled analysis of 3 multicenter, randomized, open-label studies (NCT03339453, NCT03421379, NCT01994746) in patients ≥18 years with T1D or T2D with induced hypoglycemia. Proportions of patients achieving treatment success [blood glucose (BG) increase to ≥70 mg/dL or increase of ≥20 mg/dL from nadir within 15 and 30 minutes]; BG ≥70 mg/dL within 15 minutes; in-range BG (70-180 mg/dL) 1 to 2 and 1 to 4 hours postdose; and BG >180 mg/dL 1 to 2 and 1 to 4 hours postdose were compared. Incremental area under curve (iAUC) of BG >180 mg/dL and area under curve (AUC) of observed BG values postdose were analyzed. Safety was assessed in all studies.
Results
Higher proportions of patients had in-range BG with NG vs IG (1-2 hours: P = .0047; 1-4 hours: P = .0034). Lower proportions of patients had at least 1 BG value >180 mg/dL with NG vs IG (1-2 hours: P = .0034; 1-4 hours: P = .0068). iAUC and AUC were lower with NG vs IG (P = .025 and P < .0001). As expected, similar proportions of patients receiving NG or IG achieved treatment success at 15 and 30 minutes (97-100%). Most patients had BG ≥70 mg/dL within 15 minutes (93-96%). The safety profile was consistent with previous studies.
Conclusion
This study demonstrated lower rebound hyperglycemia risk after NG treatment compared with IG.
Clinical Trial Registration
NCT03421379, NCT03339453, NCT01994746
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details


1 Department of Medicine, Division of Endocrinology and Diabetes, University of Minnesota , Minneapolis, MN 55455 , USA
2 Diabetes Unit, Endocrinology and Nutrition Department, Hospital Clínic de Barcelona , Barcelona 08036 , Spain
3 Eli Lilly and Company , Indianapolis, IN 46225 , USA
4 Diabetes Therapeutics and Research Center, Institute of Advanced Medical Sciences, Tokushima University , Tokushima 770-8503 , Japan
5 Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus , Aurora, CO 80045 , USA