Full text

Turn on search term navigation

© 2023 Calvo-Lobo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has been previously used to assess skin temperature related to muscle tissue conditions in the triceps surae of athletes. Nevertheless, the reliability and repeatability of an infrared thermography device designed for materials, such as the Manual Infrared Camera PCE-TC 30, have yet to be determined to measure skin temperature of the triceps surae muscle tissue of athletes.

Objective

The purpose was to determine the procedure’s intra- and inter-session reliability and repeatability to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device in the triceps surae muscle tissue of athletes, which was initially designed to measure the superficial temperature of materials.

Methods

A total of 34 triceps surae muscles were bilaterally assessed from 17 healthy athletes using the Manual Infrared Camera PCE-TC 30 thermography device to determine intra- (at the same day separated by 1 h) and inter-session (at alternate days separated by 48 h) reliability and repeatability of the skin temperature of the soleus, medial and lateral gastrocnemius muscles. The triceps surae complex weas measured by a region of interest of 1 cm2 through five infrared thermography images for each muscle. Statistical analyses comprised intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MCD), systematic error of measurement, correlation (r), and Bland-Altman plots completed with linear regression models (R2).

Results

Intra- and inter-session measurements of the proposed infrared thermography procedure showed excellent reliability (ICC(1,2) = 0.968–0.977), measurement errors (SEM = 0.186–0.232 °C; MDC = 0.515–0.643 °C), correlations (r = 0.885–0.953), and did not present significant systematic error of measurements (P > 0.05). Adequate agreement between each pair of measurement moments was presented by the Bland-Altman plots according to the limits of agreement and non-significant linear regression models (R2 = 0.000–0.019; P > 0.05).

Conclusions

The proposed procedure to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device presented excellent intra- and inter-session reliability and repeatability in athletes’ triceps surae muscle tissue. Future studies should consider the SEM and MDC of this procedure to measure the skin temperature of soleus, medial, and lateral gastrocnemius muscles to promote triceps surae muscle prevention and recovery in athletes.

Details

Title
Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
Author
Calvo-Lobo, Cesar; San-Antolín, Marta; García-García, Daniel; Becerro-de-Bengoa-Vallejo, Ricardo; Losa-Iglesias, Marta Elena; Cosín-Matamoros, Julia; Casado-Hernández, Israel; Martínez-Jiménez, Eva María; Mazoteras-Pardo, Victoria; Rodríguez-Sanz, David
Publication year
2023
Publication date
Mar 9, 2023
Publisher
PeerJ, Inc.
e-ISSN
21678359
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2784989047
Copyright
© 2023 Calvo-Lobo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.