Full text

Turn on search term navigation

© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Respiratory rate (RR) changes in the elderly can indicate serious diseases. Thus, accurate estimation of RRs for cardiopulmonary function is essential for home health monitoring systems. However, machine learning (ML) algorithm errors embedded in health monitoring systems can be problematic in medical decision-making because some data have much larger sample sizes in the training set than others. This difference in sample size implies biosignal data imbalance. Therefore, we propose a novel methodology that combines bootstrap-based imbalanced continuous power spectral generation (IPSG) with ML approaches to estimate RRs and uncertainty to address data imbalance. The sample differences between normal breathing (12–20 breaths per minute (brpm)), dyspnea (≥20 brpm), and hypopnea (<8 brpm) show significant data imbalance, which can affect the learning of ML algorithms. Hence, the normal breathing part with a large amount of data is well-trained. In contrast, the dyspnea and hypopnea parts with relatively fewer data are not well-trained, and this data imbalance makes it difficult to estimate the reference variables of the actual dyspnea and hypopnea data parts, thus generating significant errors. Hence, we apply ML models by mixing artificial feature curves generated using a bootstrap model with the original feature curves to estimate RRs and solve this problem. As a result, the nonparametric bootstrap approach significantly increases the number of artificial feature curves. The generated artificial feature curves are selectively utilized in the highly imbalanced parts. Therefore, we confirm that IPSG is efficiently trained to predict the complex nonlinear relationship between the feature vectors obtained from the photoplethysmography signal and the reference RR. The proposed methodology shows more accurate prediction performance and uncertainty. Combining the proposed Gaussian process regression (GPR) with IPSG based on the Beth Israel Deaconess Medical Center dataset, the mean absolute error of the RR is 0.79 and 1.47 brpm. Our approach achieves high stability and accuracy by randomly mixing original and artificial feature curves. The proposed GPR-IPSG model can improve the performance of clinical home-based monitoring systems and design a reliable framework.

Details

Title
Imbalanced Power Spectral Generation for Respiratory Rate and Uncertainty Estimations Based on Photoplethysmography Signal
Author
Lee, Soojeong 1 ; Al-antari, Mugahed A 2   VIAFID ORCID Logo  ; Gyanendra Prasad Joshi 3   VIAFID ORCID Logo  ; Gu, Yeong Hyeon 2   VIAFID ORCID Logo 

 Department of Computer Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea 
 Department of Artificial Intelligence and Data Science, Sejong University, Seoul 05006, Republic of Korea; [email protected] 
 Department of AI Software, Kangwon National University, Samcheok 10587, Kangwon State, Republic of Korea; [email protected] 
First page
1437
Publication year
2025
Publication date
2025
Publisher
MDPI AG
e-ISSN
14248220
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3176348741
Copyright
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.