Content area

Abstract

Aim: Computer-aided design/computer-aided manufacturing (CAD/CAM) technology is gaining popularity in dentistry, and more recently, used to fabricate custom post-and cores (PC) for endodontically treated teeth. The purpose of this study was to evaluate the overall retention of conventional cast gold post-and-cores compared to CAD/CAM fabricated printed, milled titanium post-and-core and milled zirconia post-and-cores based on load, time of dislodgement '. Results: Pull out test revealed higher retention values for (CPTPC) and (CMTPC) among the groups. When compared to (CMZPC), conventional (CCGPC) revealed significantly better retention values .Cohesive failure was observed with groups I, II and IV. However, group III revealed a mixed type of failure.

Details

Business indexing term
Location
Company / organization
Title
Evaluate the retention of conventional cast gold post-and-cores compared to CAD/CAM fabricated printed, milled titanium post-and-core and milled zirconia post-and-cores based on load - an invitro study
Author
Sharma, Yesh 1 ; Kumari, Shweta 2 

 Reader, Department of Conservative Dentistry and Endododntics, Pacific Dental College and Hospital, Udaipur, Rajasthan, India; 
 Intern, Pacific Dental College and Hospital, Udaipur, Rajasthan, India 
Volume
13
Issue
3
Pages
50-53
Publication year
2025
Publication date
Mar 2025
Section
Case Report
Publisher
Journal of Advanced Medical and Dental Sciences Research (JAMDSR)
Place of publication
Amritsar
Country of publication
India
Publication subject
e-ISSN
23219599
Source type
Scholarly Journal
Language of publication
English
Document type
Journal Article
ProQuest document ID
3194730518
Document URL
https://www.proquest.com/scholarly-journals/evaluate-retention-conventional-cast-gold-post/docview/3194730518/se-2?accountid=208611
Copyright
Copyright Journal of Advanced Medical and Dental Sciences Research (JAMDSR) 2025
Last updated
2025-04-25
Database
2 databases
  • ProQuest One Academic
  • ProQuest One Academic