Abstract
Background
Shake flasks are essential tools in biotechnological development due to their cost efficiency and ease of use. However, a significant challenge is the miniaturization of process analytical tools to maximize information output from each cultivation. This study aimed to develop a respiration activity online measurement system via off-gas analysis, named “Transfer rate Online Measurement” (TOM), for determining the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and the respiration quotient (RQ) in surface-aerated bioreactors, primarily targeting shake flasks.
Results
Sensors for off-gas analysis were placed in a bypass system that avoids the shaking of the electronics and sensors. An electrochemical oxygen sensor and an infrared CO2 sensor were used. The bypass system was combined with the established method of recurrent dynamic measurement phases, evaluating the decrease in oxygen and the increase in CO2 during stopped aeration. The newly developed measurement system showed high accuracy, precision and reproducibility among individual flasks, especially regarding CTR measurement. The system was compared with state-of-the-art RAMOS technology (Respiration Activity Monitoring System, see explanation below) and calibrated with a non-biological model system. The accuracy of RQ measurement was +-4% for the tested range (8% filling volume, OTR and CTR: 0–56 mmol/L/h), allowing for the determination of metabolic switches and quantitative analysis of metabolites. At ambient CO2 levels, a CTR resolution of less than 0.01 mmol/L/h was possible. The system was applied to the microbial model systems S. cerevisiae, G. oxydans, and E. coli. Physiological states, such as growth vs. protein production, could be revealed, and quantitative analysis of metabolites was performed, putting focus on RQ measurements.
Conclusions
The developed TOM system showcases a novel approach to measuring OTR, CTR, and RQ in shaken bioreactors. It offers a robust and accurate solution for respiration activity analysis. Due to its flexible design and tunable accuracy, it enables measurement in various applications and different shake flasks.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer