Abstract

Using multimodal wearable devices to diagnose cardiovascular diseases early is essential for providing timely medical assistance, particularly in remote areas. This approach helps prevent risks and reduce mortality rates. However, prolonged use of medical devices can lead to measurement inaccuracies, necessitating calibration to maintain precision. Unfortunately, wearable devices often lack affordable calibrators that are suitable for personal use. This study introduces a low-cost simulation system for phonocardiography (PCG) and photoplethysmography (PPG) signals designed for a multimodal smart stethoscope calibration. The proposed system was developed using a multicore microprocessor (MCU), two digital-to-analog converters (DACs), an LED light, and a speaker. It synchronizes dual signals by assigning tasks based on a multitasking function. A designed time adjustment algorithm controls the pulse transit time (PTT) to simulate various cardiovascular conditions. The simulation signals are generated from preprocessed PCG and PPG signals collected during in vivo experiments. A prototype device was manufactured to evaluate performance by measuring the generated signal using an oscilloscope and a multimodal smart stethoscope. The preprocessed signals, generated signals, and measurements by the smart stethoscope were compared and evaluated through correlation analysis. The experimental results confirm that the proposed system accurately generates the features of the physiological signals and remains in phase with the original signals.

Details

1009240
Business indexing term
Title
Development of a Low-Cost Multi-Physiological Signal Simulation System for Multimodal Wearable Device Calibration
Author
Tumenkhuslen, Delgerkhaan 1 ; Wei, Qun 2   VIAFID ORCID Logo  ; Jung Jiwoo 3 ; Lee, Sangwon 3 ; Gangoh, Na 1 ; Kim Bongjo 1 ; Kim, In-Cheol 4 ; Park, Heejoon 5   VIAFID ORCID Logo 

 Department of Biomedical Engineering, Graduate School of Medicine, Keimyung University, Daegu 42601, Republic of Korea; [email protected] (T.D.); [email protected] (J.J.); [email protected] (S.L.); [email protected] (G.N.); [email protected] (B.K.) 
 Department of Biomedical Engineering, College of Engineering, Keimyung University, Daegu 42601, Republic of Korea; [email protected], Clairaudience Co., Ltd., Daegu 42601, Republic of Korea 
 Department of Biomedical Engineering, Graduate School of Medicine, Keimyung University, Daegu 42601, Republic of Korea; [email protected] (T.D.); [email protected] (J.J.); [email protected] (S.L.); [email protected] (G.N.); [email protected] (B.K.), Clairaudience Co., Ltd., Daegu 42601, Republic of Korea 
 Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Republic of Korea; [email protected] 
 Department of Biomedical Engineering, College of Engineering, Keimyung University, Daegu 42601, Republic of Korea; [email protected] 
Publication title
Volume
13
Issue
6
First page
239
Number of pages
15
Publication year
2025
Publication date
2025
Publisher
MDPI AG
Place of publication
Basel
Country of publication
Switzerland
e-ISSN
22277080
Source type
Scholarly Journal
Language of publication
English
Document type
Journal Article
Publication history
 
 
Online publication date
2025-06-10
Milestone dates
2025-04-25 (Received); 2025-06-06 (Accepted)
Publication history
 
 
   First posting date
10 Jun 2025
ProQuest document ID
3223943038
Document URL
https://www.proquest.com/scholarly-journals/development-low-cost-multi-physiological-signal/docview/3223943038/se-2?accountid=208611
Copyright
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Last updated
2025-06-25
Database
ProQuest One Academic