Content area

Abstract

Additive manufacturing (AM) offers precision and efficiency in occlusal splint fabrication; however, the combined influence of build orientation and post-curing duration on the mechanical performance of splint resins remains insufficiently explored. This in vitro experimental study evaluated the effects of three build orientations (0°, 45°, and 90°) and three post-curing protocols (uncured, standard, and extended) on the flexural strength (FS), flexural modulus (FM) and Vickers hardness number (VHN) of a Class IIa biocompatible occlusal splint resin (NextDent Ortho Rigid). A total of 180 specimens were fabricated using a vat polymerization-type 3D printing system. Statistical analyses were conducted using one-way analyses of variance and Tukey’s tests at a significance level of α = 0.05. Both build orientation and post-curing duration significantly affected FS and VHN (p < 0.001). The combination of 45° build orientations and extended post-curing produced the highest FS (169.76 MPa) and FM (7502.17 MPa), exceeding values typically reported for 3D-printed splints, while the 90° orientation with extended curing achieved the highest VHN (21.88). Hardness gains, however, plateaued beyond standard curing, indicating a trade-off between strength and surface hardness. These results demonstrate that print orientation and post-curing time are decisive parameters in optimizing the mechanical performance of 3D-printed occlusal splints. For high-load clinical applications such as bruxism, prioritizing flexural strength over surface hardness may improve appliance longevity, supporting 45° orientation with extended curing as an evidence-based manufacturing approach.

Details

1009240
Business indexing term
Title
Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin
Author
Sahin Mustafa 1   VIAFID ORCID Logo  ; Buyuk Suleyman Kutalmış 2   VIAFID ORCID Logo  ; Simsek Huseyin 3   VIAFID ORCID Logo  ; Akdoğan Tuncer 4   VIAFID ORCID Logo  ; Safiyenur, Bircan 3   VIAFID ORCID Logo  ; Toroglu, Mustafa Serdar 1 

 Department of Orthodontics, Faculty of Dentistry, Çukurova University, Adana 01250, Türkiye; [email protected] (M.S.); storoğ[email protected] (M.S.T.) 
 Department of Orthodontics, Faculty of Dentistry, Ordu University, Ordu 52200, Türkiye 
 Department of Pedodontics, Faculty of Dentistry, Ordu University, Ordu 52200, Türkiye; [email protected] (H.S.); [email protected] (S.B.) 
 Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Çukurova University, Adana 01250, Türkiye; [email protected] 
Publication title
Volume
12
Issue
12
First page
1322
Number of pages
14
Publication year
2025
Publication date
2025
Publisher
MDPI AG
Place of publication
Basel
Country of publication
Switzerland
Publication subject
e-ISSN
23065354
Source type
Scholarly Journal
Language of publication
English
Document type
Journal Article
Publication history
 
 
Online publication date
2025-12-04
Milestone dates
2025-11-18 (Received); 2025-12-03 (Accepted)
Publication history
 
 
   First posting date
04 Dec 2025
ProQuest document ID
3286260648
Document URL
https://www.proquest.com/scholarly-journals/effect-print-orientation-post-curing-duration-on/docview/3286260648/se-2?accountid=208611
Copyright
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Last updated
2025-12-24
Database
ProQuest One Academic