Abstract

The applicability of three kinds of electrode configurations used to delineate a buried horizontal pipe was studied. A 3D resistivity imaging survey was carried out along eight parallel lines using pole-pole, pole-dipole, and dipole-dipole arrays with 1m minimum electrode spacings. Roll-along measurements were carried out to cover a rectangular grid. The 2D and 3D least squares algorithms based on the robust inversion method were used in the inversion of the apparent resistivity data sets. The 2D inversion of data sets could not delineate the orientation and dimension of the subsurface anomalies clearly. To obtain more accurate results, a 3D joint inversion of the pole-pole and pole-dipole data sets was performed, as well as of pole-pole and dipole-dipole data sets. In this case, both horizontal and vertical dimensions of subsurface structures were resolved. The resulting model obtained from each array was compared to those of joint inversion method. The result showed that the horizontal resolution does not improve so much as that in the vertical direction when joint inversion is applied.[PUBLICATION ABSTRACT]