Background: Catheter ablation has been established as a curative treatment strategy for ventricular arrhythmias. The standard procedure of most ventricular arrhythmias originating from the right ventricle is performed via the femoral vein. However, a femoral vein access may not achieve a successful ablation in some patients.
Case presentation: We reported a case of a 29-year old patient with symptomatic premature ventricular contractions was referred for catheter ablation. Radiofrequency energy application at the earliest endocardial ventricular activation site via the right femoral vein could not eliminate the premature ventricular contractions. Epicardial mapping could not obtain an earlier ventricular activation when compared to the endocardial mapping, and at the earliest epicardial site could not provide an identical pace mapping. Finally, we redeployed the ablation catheter via the right subclavian vein by a long sheath. During mapping of the subvalvular area of the right ventricle, a site with a good pace mapping and early ventricular activation was found, and premature ventricular contractions were eliminated successfully.
Conclusion: Ventricular arrhythmias originating from the subtricuspid annulus may be successfully abolished via a trans-subclavian approach and a long sheath. Although access via the right subclavian vein for mapping and ablation is an effective alternative, it is not a routine approach.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer