Full Text

Turn on search term navigation

© 2012 Maarten W. Peeters. This is an open-access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Introduction

The aim of the study was to evaluate whether subject positioning would affect the measurement of raw body volume, thoracic gas volume, corrected body volume and the resulting percent body fat as assessed by air displacement plethysmography (ADP).

Methods

Twenty-five young adult men (20.7±1.1y, BMI = 22.5±1.4 kg/m2) were measured using the BOD POD® system using a measured thoracic gas volume sitting in a ‘forward bent’ position and sitting up in a straight position in random order.

Results

Raw body volume was 58±124 ml (p<0.05) higher in the ‘straight’ position compared to the ‘bent’ position. The mean difference in measured thoracic gas volume (bent-straight = −71±211 ml) was not statistically significant. Corrected body volume and percent body fat in the bent position consequently were on average 86±122 ml (p<0.05) and 0.5±0.7% (p<0.05) lower than in the straight position respectively.

Conclusion

Although the differences reached statistical significance, absolute differences are rather small. Subject positioning should be viewed as a factor that may contribute to between-test variability and hence contribute to (in)precision in detecting small individual changes in body composition, rather than a potential source of systematic bias. It therefore may be advisable to pay attention to standardizing subject positioning when tracking small changes in PF are of interest.The cause of the differences is shown not to be related to changes in the volume of isothermal air in the lungs. It is hypothesized and calculated that the observed direction and magnitude of these differences may arise from the surface area artifact which does not take into account that a subject in the bent position exposes more skin to the air in the device therefore potentially creating a larger underestimation of the actual body volume due to the isothermal effect of air close to the skin.

Details

Title
Subject Positioning in the BOD POD® Only Marginally Affects Measurement of Body Volume and Estimation of Percent Body Fat in Young Adult Men
Author
Peeters, Maarten W
First page
e32722
Section
Research Article
Publication year
2012
Publication date
Mar 2012
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1338841938
Copyright
© 2012 Maarten W. Peeters. This is an open-access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.