It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Doc number: 11
Abstract
Background: In dislocated proximal tibial fractures, the most frequently used treatment is ORIF with screws and plates. Minimally-invasive techniques using external fixation are an alternative. The aim of this study was to analyse the clinical and radiological results using the Ilizarov technique in both uni- and bicondylar tibial fractures.
Methods: Thirty consecutive patients with isolated fractures of the proximal tibia were treated with the Ilizarov technique, 11 Schatzker I-IV with 2-3 rings and 19 Schatzker V-VI with 3-4 tibial rings and a femoral, hinged, two-ring extension. Unrestricted weight-bearing was allowed. Pre and post-operatively, conventional radiographs, computerized tomography scans, post-operative pain assessments and complications were evaluated. The knee function was evaluated with the EQ-5D, NHP and KOOS scores, as well as self-appraisal.
Results: All the fractures healed. Twenty-five patients achieved a range of motion better than 10-100º. The type I-IV fractures had a shorter operating time and hospital stay, as well as better knee flexion, and the self-appraisal indicated that they tolerated the treatment better. Pin infections occurred in 4% of the pin sites, but only two patients required debridement. Two patients developed compartment syndrome and underwent fasciotomy. No patient complained of functional knee instability. Two patients underwent a total knee arthroplasty because of residual pain. The overall result was judged as satisfactory in twenty-seven patients.
Conclusions: The Ilizarov method produces a good clinical outcome and is a valuable treatment alternative in proximal tibial fractures of all types.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer