About the Authors:
Lan Wang
Contributed equally to this work with: Lan Wang, Chunming Rao
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Chunming Rao
Contributed equally to this work with: Lan Wang, Chunming Rao
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Kai Gao
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Yonghong Li
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Zhihao Fu
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Hua Bi
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Junzhi Wang
* E-mail: [email protected]
Affiliation: National Institutes of Food and Drug Control, Beijing, People's Republic of China
Introduction
With the rapid development of biotechnology, more and more biopharmaceuticals have been licensed to the market. The doses of biopharmaceuticals have increased from microgram to milligram or even gram for the demand of clinical treatment, and more biological products needed long-term and repeated administration. The host cells used to produce biopharmaceuticals can be sources of a range of complex, heterogeneous, and potentially unsafe impurities, and host cell DNA is among these. Much of the safety concerns associated with residual DNA in biological products lies in the possibility that host cell DNA may result in tumors or adverse reactions [1], [2]. E. coli expression system is favored for its advantages of low-cost, high productivity and easy operation, so it is often served as the preferred expression system of recombinant protein (e.g., recombinant cytokines, recombinant hormones, recombinant enzymes and recombinant vaccines, etc) [3]. A quality control is therefore needed to limit the residual DNA of E. coli derived biological products. The acceptable residual limit of DNA by World Health Organization (WHO) and European Union (EU) is up to 10 ng of residual DNA per dose [4]. The specification permitted by Food and Drug Administration (FDA) is 100 pg/dose [5]. In Pharmacopoeia of the People's Republic of China (Ch. P), the specification for DNA content is 10 ng/dose or less for bacteria-derived biologicals.
The methods used to determine the residual DNA content of biopharmaceuticals include hybridization, DNA-binding protein, q-PCR and fluorescence dye (PicoGreen), etc [6], [7], [8], [9], [10], [11]. Hybridization assay represents a semi-quantitative assay, while q-PCR and fluorescence dye give quantitative results. Quantitative assays are typically preferred instead of semi-quantitative assays because the results are considered more accurate and precise, which allows better process monitoring and release control. Generally, the laboratories or sponsors develop their own batch of E. coli DNA and use as the internal reference after UV absorption reading. This practice gives rise to systemic error and consequently makes the results less comparable between laboratories. In order to standardize residual DNA assay and improve inter-laboratory comparisons, we have established the first national reference standard of E. coli DNA suitable for two quantitative residual DNA assays (q-PCR and PicoGreen) and our results indicate that it satisfies the sensitivity and precision required for quantitative residual DNA assay. Presently, there are no public reports of similar reference standard studies for the determination of residual DNA contents of prokaryotic-derived recombinant products.
Materials and Methods
Preparation and quality control of E. coli DNA reference
E. coli BL21 (ATCC: BAA-1025) were selected as the source materials for E. coli DNA standards, revived and cultured in Luria Bertani (LB) medium at 37°C for 16 h with vigorous shaking. The bacterial cells were harvested by centrifugation at 6000 g for 15 min at 4°C. The bacterial pellet was resuspended in TE buffer (pH 8.0). The suspension was used for isolating genomic DNA using CTAB/phenol-chloroform DNA extraction method. Briefly, the bacterial suspension was added 20 mg/mL protease K and 10% SDS, mixed completely, and incubated at 37°C for 1 h. The lysate was then added 5 M NaCl and CTAB/NaCl solution preheated by 65°C, incubated for 20 min at 65°C, and extracted twice with 24∶1 chloroform: isoamyl alcohol. The supernatant was precipitated by 1∶1 isopropyl alcohol, washed twice with 70% alcohol solution, and the DNA was dissolved in TE buffer. For quality control of the genomic DNA, we analyzed DNA purity by determining the ratio of spectrophotometric absorbance at 260 nm to that of 280 nm, combined with electrophoresis.
Filling of the E. coli DNA reference
The extracted BL21 DNA was diluted with sterilized TE buffer (pH 8.0) to reach a final concentration of 100 μg/mL. The solution was dispensed in 1.0 mL vials (0.1 mL each) manually and stored at −70°C.
Concentration calibration of E. coli DNA reference
Participants.
Six laboratories from China, including five manufacturers and one national control laboratories, participated in the collaborative study to calibrate the concentration of E. coli DNA reference using UV absorption method.
Study design.
Precise directions were given to participants regarding sampling, dilution and storage prior to the start of the studies. In short, DNA reference was thawed, mixed well by vortex, and centrifuged at 10000 g for 2 min. A certain amount of DNA was taken and five-fold diluted with TE buffer. The optical path of spectrophotometry was set at 10 mm for the quartz cuvette, and the absorbency values at 260 nm and 280 nm wavelengths were recorded. The DNA concentration (μg/mL) was calculated by multiplying 50 with the absorbency value at 260 nm. All laboratories conducted three repeated assays for each vial, and the participants were requested to perform their assays on 5 different days. All raw data together with assay details were returned to NIFDC for analysis. All mean results are reported as unweighted geometric means with 95% confidence limits. Variability within and between laboratories has been expressed using coefficients of variation (%, CV). Participating laboratories listed in Table S1 and are referred to throughout this paper by a code number, allocated at random, and not related to the order of listing.
Stability studies
The stability of the candidate material, E. coli DNA in TE buffer, was tested by accelerate thermal degradation study and the real time stability study [12]. In the accelerated thermal degradation study, three vials of the candidate material were stored at different temperatures for 4 months. Each vial, stored at −20°C, 4°C, 25°C, 37°C, was assayed for DNA content and purity by spectrophotometry and electrophoresis. Additionally, in the real time stability study, three vials of the candidate material stored at −20°C for 24 months were tested for DNA content and electrophoresis purity.
Applicability studies of E. coli DNA reference
Fluorescence dye (PicoGreen) assay.
The protocol of fluorescence dye assay for residual DNA was based on Ch.P and instructions for Quant-iT PicoGreen dsDNA kit. Briefly, E. coli DNA reference was serially diluted (2-fold) with TE buffer from a starting concentration of 100 ng/mL to 0.781 ng/mL, and each dilution was performed in triplicate. Then equal volumes of diluted DNA reference and the Quant-iT PicoGreen working solution were mixed and incubated for 5 min at room temperature, protected from light. After incubation, the sample fluorescence was measured using excitation wavelength 480 nm and emission wavelength 520 nm in fluorescence microplate reader and analyzed using SOFTmaxPRO software.
Q-PCR assay.
Oligonucleotide primers against the 23S rRNA (GenBank accession number: V00331, GI: 42756) sequence of E. coli were used for detection of E. coli DNA by real-time PCR (Primer23S sense: 5′-GTC TGG AAA GGC GCG CGA-3′/Primer23S antisense: 5′-GTG TCC CGC CCT ACT CA-3′). Serial ten-fold dilutions from 102 pg/μL to 1 fg/μL of E. coli DNA reference were prepared in TE buffer, and each dilution was performed in triplicate. PCR reaction was then carried out with the above primer pairs using the templates of serially diluted genomic DNA. PCR was performed in 7500 FAST Real-Time PCR System (Applied Biosystems, USA) using the following conditions: initial heat denaturation at 95°C for 10 min, followed by 45 cycles each of 95°C for 15 s, 60°C for 1 min. Ten microliters (10 μL) of DNA reference were amplified in a total volume of 25 μL mixture of 1×Power SYBR Green PCR Master Mix, 0.2 μM of each primer. A standard curve for quantification was generated by plotting the log of the DNA concentration of the known standard (Log Co), against the cycle number at defined point (Ct).
Results
Preparation and quality control of E. coli DNA reference
The genomic DNA of BL21 was extracted and first analyzed by UV-visible spectrophotometer at wavelengths from 200 to 800 nm. As shown in Fig. 1A, the extracted DNA materials were of high quality and purity, evidenced by a strong absorption peak at about 260 nm as well as OD260/OD280 ratio of 1.8 to 1.9. In order to enlarge the observation of 260 nm absorption peak shape, Figure 1 shows a cut diagram with wavelengths from 240 nm to 350 nm. The genomic DNA of E. coli BL21 was also analyzed by 1.0% agarose gel electrophoresis. Fig. 1B showed a single DNA band. Taken together, these results indicated that the genomic DNA prepared were of high quality and purity and satisfies the requirements of Ch. P and WHO for DNA standard samples [13].
[Figure omitted. See PDF.]
Figure 1. Preparation and quality control of E. coli DNA reference standard.
(A) Analysis of E. coli genomic DNA with full wavelength scanning (240–350 nm). (B) Results of Agarose Gel electrophoresis for E. coli genomic DNA. M, λ-Hind III digest DNA marker. Lane 1, E. coli genomic DNA.
https://doi.org/10.1371/journal.pone.0074166.g001
Concentration calibration of E. coli DNA reference
A total of 1000 vials of E. coli DNA reference with a volume of 100 μL were prepared. Six certified, independent laboratories were invited to collaboratively calibrate the concentration and purity of the E. coli DNA. All participants performed 15 independent assays. A total of 90 results were obtained. The calibration results for E. coli DNA reference are summarized in Table 1. The overall geometric mean of DNA content was 96.2 μg/mL (95% confidence limits: 95.5–96.9 μg/mL, CV 3.4%, n = 90). Within-laboratory CVs ranged from 0.5% to 4.8% with an average of 2.1% indicating a small level of variability within each laboratory. The average ratio of OD260/OD280 was determined to be 1.88, well within the range of 1.8–1.9, indicating high purity of the DNA preparation (Fig. 2). In the following experiments, 96.2 μg/mLwas used for calculation and dilution purpose.
[Figure omitted. See PDF.]
Figure 2. Trend of OD260/OD280 in collaborative calibration study for E. coli DNA reference standard.
https://doi.org/10.1371/journal.pone.0074166.g002
[Figure omitted. See PDF.]
Table 1. The calibration results of E. coli DNA content by UV absorption (μg/mL).
https://doi.org/10.1371/journal.pone.0074166.t001
Stability study
E. coli DNA reference stored at elevated temperatures for a period of four months was assayed for DNA content and purity by spectrophotometry and electrophoresis. As shown in Fig. 3, there was no difference observed in the DNA content and purity between the stored samples (−20°C, 4°C, 25°C, 37°C) and samples at −20°C as reference controls. In addition, real time stability study was performed using the samples stored at −20°C for 24 months. The DNA content of the samples stored at −20°C was 98.3±1.4 μg/mL, and the electrophoresis showed a single band (Fig. 3C). These results confirmed that the E. coli DNA reference is stable at −20°C. In generally, for liquid reference standard, the recommended storage temperature is −70°C, in order to guarantee the long-term stability of the reference standard. So as the national standard, the storage temperature of the E. coli DNA reference is required for −70°C.
[Figure omitted. See PDF.]
Figure 3. Stability of E. coli DNA reference standard.
(A) The content and OD260/OD280 of E. coli DNA reference stored under four different temperatures for four months. (B) The electrophoresis of E. coli DNA reference stored under four different temperatures for four months. Because of high DNA content, some genomic DNA was stuck in the well. (C) The electrophoresis of E. coli DNA reference stored at −20°C for 24 months.
https://doi.org/10.1371/journal.pone.0074166.g003
Applicability studies of E. coli DNA reference
Using the E. coli DNA reference, the PicoGreen fluorescence method had high sensitivity up to 0.781 ng/mL of DNA with good linearity in the concentration range of 0.781–100 ng/mL. Furthermore, the fluorescence CV of each concentration was less than 10% indicating good precision using the DNA reference (Table 2). By SOFTmaxPRO software, the equation of the regression line was y = 1.95x+1.65, r = 0.9990. For q-PCR assay, the limit of quantification (LOQ) using the DNA reference was 1 fg/μL, and the log-linear regression plot (Fig. 4A) showed a strong linear relationship (r = 0.9940) between the log of the DNA concentration of the known standard (Log Co) and the Ct values. The amplification curve was smooth and the dissociation curves had a single peak (Fig. 4B and C). Therefore, the standards were suitable for residual DNA assay by PicoGreen and q-PCR.
[Figure omitted. See PDF.]
Figure 4. Results of real-time PCR for E. coli DNA reference standard.
(A) Standard curve. Ct was plotted against each concentration (Log Co). Ct represents the cycle at which reporter signal was first detected. (B) Amplification curves. 1–6: 102, 10, 1, 1×10−1, 1×10−2, 1×10−3 pg/μL. (C) Melting curves. It showed primer pair was specific for E. coli DNA.
https://doi.org/10.1371/journal.pone.0074166.g004
[Figure omitted. See PDF.]
Table 2. Results of PicoGreen assay for E. coli DNA reference.
https://doi.org/10.1371/journal.pone.0074166.t002
Consistency study of E. coli DNA reference
To evaluate the consistency of multiple vials of the DNA reference, the PicoGreen fluorescence method was used to test four different vials of the DNA reference. As shown in Fig. 5, four standard curves showed good consistency, and the fluorescence CVs of each concentration from four standard curves were less than 6%, which indicated the consistency of the DNA reference could meet the requirements of the national standard.
[Figure omitted. See PDF.]
Figure 5. The consistency analysis of E. coli DNA reference standard using PicoGreen fluorescence method.
https://doi.org/10.1371/journal.pone.0074166.g005
Discussion
One can address residual DNA in biopharmaceutical processes in two ways: by validating clearance during process validation or by monitoring residual DNA levels by routine testing of the drug substance [7]. Regardless of the analytical procedures for the quantification of residual DNA, the reference material of DNA content is required. Such reference material would improve inter-laboratory comparisons and also seen as a step towards standardization of methodologies. Recently, with the expiration of patent protection for original biologics, the guidelines for biosimilar products issued or drafted by EMEA, WHO, Canada and the United States [14], [15], [16], [17] all require head to head comparative studies of quality between similar biotherapeutic product (SBP) and reference biotherapeutic product (RBP, the original brand products). The DNA reference standard also plays an important role in impurity comparative studies between SBP and RBP. E. coli expression system was widely used to produce biological products, so this study was initiated to develop and evaluate an E. coli DNA reference for quantitative residual DNA assays, including q-PCR and fluorescence assay which are widely employed in China and other countries. The most commonly used E. coli strains for recombinant protein production include BL21, K12, and DH5α, etc. Any strain of E. coli could be used as the source material for the E. coli DNA reference for the above quantitative residual DNA assays, which were both non-strain specific assays. In this study, the clearly traceable E. coli BL21 from ATCC sources were selected as the source material for the E. coli DNA reference. For preparing this reference, WHO guidelines for standard materials were referred to and strictly followed [3], [18], [19], [20].
To meet the requirements for DNA standard, the following steps have been taken to ensure the quality and accuracy of E. coli DNA reference. First, the DNA reference solution was of high purity by a single peak at 260 nm and OD260/OD280 ratio of 1.8 to 1.9 (Fig. 1A), as well as a single band of electrophoresis (Fig. 1B). Second, the concentration of the DNA reference (96.2 μg/mL) was collaboratively calibrated by six independent, certified laboratories (Table 1 and Fig. 2). Third, results for accelerated degradation and real time stability studies indicated that the DNA reference solution was stable at −20°C (Fig. 3). In order to further control the stability of the DNA reference, we required the recommended storage temperature of the E. coli DNA reference was −70°C. Moreover, with high sensitivity (0.781 ng/mL and 1 fg/μL) and precision, it has satisfied the requirements for testing residual DNA of E. coli by PicoGreen and q-PCR (Table 2 and Fig. 4). Finally, the reference showed good consistency evaluated by PicoGreen assay (Fig. 5). Therefore, we have successfully established the DNA reference and it was adopted by the Expert Committee on Biological Standardization of P.R. China (code 2012–0026) in May 2012 as the 1st national standard for the determination of residual DNA content of E. coli derived products by fluorescence dye and q-PCR assay. The reference has been applied in National Control Laboratories and domestic industries in China for more than one year. It has been playing an important role in quantitatively detecting residual DNA for E. coli derived biologicals. Further studies are ongoing to investigate the quality of the standard throughout the life-time of the products as well as to gather stability data. It is the first time to report the E. coli DNA standard for quantitative residual DNA assay, which can provide clues for other similar reference product in the quality control of biologicals.
Supporting Information
[Figure omitted. See PDF.]
Table S1.
List of participating laboratories.
https://doi.org/10.1371/journal.pone.0074166.s001
(DOC)
Acknowledgments
We wish to thank all participants in the collaborative study for their time and invaluable expert contributions, as this study would not have been possible without their input. We would like to thank Dr. Shouchun Cao for helpful discussion.
Author Contributions
Conceived and designed the experiments: JW. Performed the experiments: LW ZF HB. Analyzed the data: CR KG JW. Wrote the paper: LW CR KG JW. Guided the experiments: CR KG YL JW.
Citation: Wang L, Rao C, Gao K, Li Y, Fu Z, Bi H, et al. (2013) Development of a Reference Standard of Escherichia coli DNA for Residual DNA Determination in China. PLoS ONE 8(9): e74166. https://doi.org/10.1371/journal.pone.0074166
1. Nissom PM (2007) Specific detection of residual CHO host cell DNA by real-time PCR. Biologicals 35: 211–215.
2. Knezevic I, Stacey G, Petricciani J, Sheets R (2009) Evaluation of cell substrates for the production of biologicals: Revision of WHO recommendations. Report of the WHO Study Group on Cell Substrates for the Production of Biologicals, Bethesda, USA. Biologicals 38: 162–169.
3. Gao K, Rao C, Tao L, Han C, Shi X, et al. (2012) Development and calibration of a standard for the protein content of granulocyte colony-stimulating factor products. Biologicals 40: 151–157.
4. European Union (2001) Position statement on the use of tumourigenic cells of human origin for the production of biological and biotechnological medicinal products, The European Agency for the Evaluation of Medicinal Products: Evaluation of medicinal products for human use. CPMP/BWP/1143/00.
5. U.S. Food and Drug Administration (1997) Points to consider in the manufacture and testing of monoclonal antibody products for human use. US Department of Health and Human Services, Food and Drug Administration, Center for Biologics Evaluation and Research.
6. Kang MJ, Yu H, Kim SK, Park SR, Yang I (2011) Quantification of trace-level DNA by real-time whole genome amplification. PLoS One 6: e28661.
7. Rathore AS, Sobacke SE, Kocot TJ, Morgan DR, Dufield RL, et al. (2003) Analysis for residual host cell proteins and DNA in process streams of a recombinant protein product expressed in Escherichia coli cells. J Pharm Biomed Anal 32: 1199–1211.
8. Desjardins P, Conklin D (2010) NanoDrop microvolume quantitation of nucleic acids. J Vis Exp 22 (45).
9. Singer VL, Jones LJ, Yue ST, Haugland RP (1997) Characterization of PicoGreen reagent and development of a fluorescence-based solution assay for double-stranded DNA quantitation. Anal Biochem 249: 228–238.
10. Kung VT, Panfili PR, Sheldon EL, King RS, Nagainis PA, et al. (1990) Picogram quantitation of total DNA using DNA-binding proteins in a silicon sensor-based system. Anal Biochem 187: 220–227.
11. Ji X, Lee K, DiPaolo B (2002) High-sensitivity hybridization assay for quantitation of residual E. coli DNA. Biotechniques 32: 1162–1167.
12. Campbell PJ (1974) International biological standards and reference preparations. I. Preparation and presentation of materials to serve as standards and reference preparations. J Biol Stand 2: 249–258.
13. WHO Expert Committee on Biological Standardization (2006) World Health Organ Tech Rep Ser 932: v–vi, 1–137.
14. European Medicine Evaluation Agency (2006) Guideline on similar biological medicinal products containing biotechnology-derived proteins as active substance: quality issues. pp. 5–7.
15. WHO website (2013) Guidelines on evaluation of similar biotherapeutic products (SBP). WHO expert committee on biological standardization, 19–23 October 2009. Available: http://apps.who.int/medicinedocs/documents/s19941en/s19941en.pdf. Accessed 2013 Aug 6.
16. Health Canada website (2013) Guidance for sponsors: Information and submission requirement for subsequent entry biologics (SEBs). 7–11. Available: http://www.hc-sc.gc.ca/dhp-mps/alt_formats/pdf/brgtherap/applic-demande/guides/seb-pbu/seb-pbu-2010-eng.pdf. Accessed 2013 Aug 6.
17. U.S. Food and Drug Administration website (2013) Quality Considerations in Demonstrating Biosimilarity to a Reference Protein Product. 10–15. Available: http://www.fda.gov/downloads/Drugs/GuidanceCompliance RegulatoryInformation/Guidances/UCM291134.pdf. Accessed 2013 Aug 6.
18. Niimi S, Oshizawa T, Naotsuka M, Ohba S, Yokozawa A, et al. (2002) Establishment of a standard assay method for human thrombomodulin and determination of the activity of the Japanese reference standard. Biologicals 30: 69–76.
19. Kline MC, Duewer DL, Travis JC, Smith MV, Redman JW, et al. (2009) Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard. Anal Bioanal Chem 394: 1183–1192.
20. Cao S, Dong G, Tang J, Li J, Liu J, et al. (2012) Development of a Vero cell DNA reference standard for residual DNA measurement in China. Hum Vaccin Immunother 9: 1–7.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2013 Wang et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
This collaborative study developed the first national Escherichia coli (E. coli) DNA reference standard for standardizing quantitative residual DNA assay methods, fluorescence dye (PicoGreen) and quantitative PCR (q-PCR), which were widely employed to measure residual DNA contents of prokaryotic-derived recombinant products. High purity of E. coli strain BL21 was extracted by the cetyl triethyl ammonium bromide (CTAB)/phenol chloroform method, analyzed by UV-visible spectrophotometry and electrophoresis, diluted with tris-EDTA (TE) buffer and manually dispensed. Then, with a cooperative calibration among six laboratories, including five manufacturers and one national control laboratory, the concentration of E. coli DNA standard solution was determined as 96.2 μg/mL (95% C.I: 95.5–96.9 μg/mL, CV 3.4%). The candidate showed excellent stability both from accelerated degradation study and real time stability study. The applicability study showed that the E. coli DNA reference could reach the sensitivity of 0.781 ng/mL and 1 fg/μL, respectively, in fluorescent dye and q-PCR assay, and also had good linearity and precision. The consistency of the reference could meet the requirements of the national reference standard. As a conclusion, the candidate material was suitable to serve as a China national standard for E. coli residual DNA determination. The successful establishment of the E. coli DNA standard will facilitate the standardization of quantitative methods for testing residual host cell DNA.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer