Abstract

Doc number: 45

Abstract

Background: There has been controversy over the diagnostic thresholds of hemoglobin A1c (HbA1c ) for diabetes. In addition, no study has examined the thresholds of glycated albumin (GA) and 1,5-anhydroglucitol (1,5-AG) for diagnosing diabetes using the presence of diabetic retinopathy (DR). We examined the optimal thresholds of various glycemic measures for diagnosing diabetes based on the prevalence of DR in community-dwelling Japanese subjects.

Methods: A total of 2,681 subjects aged 40-79 years underwent a 75-g oral glucose tolerance test, measurement of HbA1c , GA, and 1,5-AG, and an ophthalmic examination in 2007-2008. The associations of glycemic measures with DR status were examined cross-sectionally. DR was assessed by an examination of the fundus photograph of each eye and graded according to the International Clinical Diabetic Retinopathy Disease Severity Scale. We divided the values of glycemic measures into ten groups on the basis of deciles. The receiver operating characteristic (ROC) curve analysis was performed to determine the optimal threshold of each glycemic measure for detecting the presence of DR.

Results: Of the subjects, 52 had DR. The prevalence of DR increased steeply above the ninth decile for fasting plasma glucose (FPG) (6.2-6.8 mmol/l), for 2-hour postload glucose (PG) (9.2-12.4 mmol/l), for HbA1c (5.9-6.2% [41-44 mmol/mol]), and for GA (16.2-17.5%), and below the second decile for 1,5-AG (9.6-13.5 μg/mL). The ROC curve analysis showed that the optimal thresholds for DR were 6.5 mmol/l for FPG, 11.5 mmol/l for 2-hour PG, 6.1% (43 mmol/mol) for HbA1c , 17.0% for GA, and 12.1 μg/mL for 1,5-AG. The area under the ROC curve (AUC) for 2-hour PG (0.947) was significantly larger than that for FPG (0.908), GA (0.906), and 1,5-AG (0.881), and was marginally significantly higher than that for HbA1c (0.919). The AUCs for FPG, HbA1c , GA, and 1,5-AG were not significantly different.

Conclusions: Our findings suggest that the FPG and HbA1c thresholds for diagnosing diabetes in the Japanese population are lower than the current diagnostic criterion, while the 2-hour PG threshold is comparable with the diagnostic criterion. 2-hour PG had the highest discriminative ability, whereas FPG, HbA1c , GA, and 1,5-AG were similar in their ability.

Details

Title
Thresholds of various glycemic measures for diagnosing diabetes based on prevalence of retinopathy in community-dwelling Japanese subjects: the Hisayama Study
Author
Mukai, Naoko; Yasuda, Miho; Ninomiya, Toshiharu; Hata, Jun; Hirakawa, Yoichiro; Ikeda, Fumie; Fukuhara, Masayo; Hotta, Taeko; Koga, Masafumi; Nakamura, Udai; Kang, Dongchon; Kitazono, Takanari; Kiyohara, Yutaka
Pages
45
Publication year
2014
Publication date
2014
Publisher
BioMed Central
e-ISSN
14752840
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1503159250
Copyright
© 2014 Mukai et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.