ARTICLE
Received 9 Oct 2014 | Accepted 4 Feb 2015 | Published 11 Mar 2015
The perspective of using live cells as lenses could open new revolutionary and intriguing scenarios in the future of biophotonics and biomedical sciences for endoscopic vision, local laser treatments via optical bres and diagnostics. Here we show that a suspended red blood cell (RBC) behaves as an adaptive liquid-lens at microscale, thus demonstrating its imaging capability and tunable focal length. In fact, thanks to the intrinsic elastic properties, the RBC can swell up from disk volume of 90 up to a sphere reaching 150 , varying focal length from negative to positive values. These live optouidic lenses can be fully controlled by triggering the liquid buffers chemistry. Real-time accurate measurement of tunable focus capability of RBCs is reported through dynamic wavefront characterization, showing agreement with numerical modelling. Moreover, in analogy to adaptive optics testing, blood diagnosis is demonstrated by screening abnormal cells through focal-spot analysis applied to an RBC ensemble as a microlens array.
DOI: 10.1038/ncomms7502
Red blood cell as an adaptive optouidic microlens
L. Miccio1,*, P. Memmolo1,2,*, F. Merola1,*, P.A. Netti2 & P. Ferraro1
1 Consiglio Nazionale delle Ricerche (CNR)Istituto di Cibernetica E. Caianiello, Via Campi Flegrei 34, Pozzuoli (NA) I-80078, Italy. 2 Center for Advanced Biomaterials for Health Care@CRIB, Istituto Italiano di Tecnologia, Largo Barsanti e Matteucci 53, Napoli 80125, Italy. * These authors contributed equally to this work. Correspondence and requests for materials should be addressed to L.M. (email: mailto:[email protected]
Web End [email protected] ).
NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 1
& 2015 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502
Red blood cell (RBCs) anomalies are signicant symptoms for identication of health disorders. In particular, several blood diseases involve modication in the morphology of
such cells, that is, sickle-cell disease, malaria and spherocytosis13. For these reasons, many non-invasive optical imaging systems have been developed for the investigation of RBC morphology as a diagnostic clinical factor48. In particular, quantitative phase-contrast methods have been explored for three-dimensional (3D) shape retrieving of live and unlabelled erythrocytes measuring volumes, refractive indexes and morphological parameters912. However, all the aforementioned imaging methods require interferometric analysis and/or complex image processing for morphology retrieval in two-dimensional and 3D and, most important, the diagnosis is subjective, as it depends on the physicians personal evaluation of such images. Moreover, huge steps forward have been taken in the last years in the eld of photonic techniques applied to medical science with the aim to make less invasive and more efcient current therapies or for developing new ones. In particular, challenging results have been obtained by enlarging the potential capabilities of optical tweezers (OTs) as a no-contact tool for cell manipulation1315. Recently, for the rst time, optical trapping has been aimed in vivo at manipulating RBCs within subdermal capillaries on living mice16. At the same time, many efforts have been spent to go towards the miniaturization of a photonic device that could open new ways for endoscopic analysis1719.
In this context, we propose a new concept where cells can be manipulated and adopted as functional and active optical elements. Specically, we model RBCs as optouidic nanomicro-lenses2022 by demonstrating, in vitro, their focus tunability and imaging capability. Human erythrocytes, in their mature state and under physiological and healthy conditions, are exible biconcave disks with homogeneous distribution of the refractive index. By an optical point of view, we will take benet of the intrinsic great deformability2325 and the lack of nucleus and organelles26 thus modelling and demonstrating that an RBC is a sort of disk-shaped microstructured envelope that changes its shape and is exploitable as a tunable liquid-lens. In fact RBCs are very exible and their deformability allows them to bring oxygen even through the smallest capillaries in the vascular system. RBC morphology variation is achievable by triggering the liquid buffer osmolarity thus permitting swelling from the biconcave microuid disk, with a volume of about 90 , up to a sphere reaching 150 . By considering the RBC average refractive index4 ranging between1.38 and 1.42 immersed in a liquid buffer with lower refractive index (1.334), we show that this focal length can change in a range of about 20 mm, from deep negative values to positive ones.
A further functionality that we exploit here is about blood diagnostics. Here we demonstrate that, by exploiting the new concept of bio-microlenses and in analogy to indirect adaptive optics (IAO)-testing tools (that is, ShackHartmann)27, it is possible to discern between healthy and anomalous RBCs, thus providing a completely new, faster and much more objective diagnostic criterion. We will validate the RBC-focusing properties for providing full morphology identication. Any classical shape retrieval and conventional image-processing analysis will not be necessary. Examples of fast blood screening, 3D morphology retrieval and imaging properties of the RBC lens are reported.
ResultsRBC focal length tunability. RBC is modelled as a pure phase object, and simulation is performed implementing a modication of the formula for the ideal RBC biconcave shape28 (see Supplementary Methods 1 and Supplementary Figs 1 and 2 for details). We consider a monochromatic plane wave propagating
thorough it that behaves as an aberrated lens. Therefore the diffracted wavefront at the exit pupil of the microlens, computed using a phase-retrieval approach29, is expressed as a linear combination of Zernike polynomials3033.
j x; y
X
a
j
Zj x; y 1
Through computation we noted that the focal properties of normal discocyte are mainly due only to the rst two quadratic polynomial terms, which correspond to the contributions of Zernike coefcients of order 4 and 12, that is, focus shift, a4, and
third-order spherical aberrations, a12, while other terms are negligible. Meanwhile spherocytes (Methods) can be described essentially only by a focus-shift term, a4. To demonstrate the different focal properties between discocytes and spherocytes, we employ interference (that is, digital holography (DH)) microscopy (see Methods)3438. Specically, to prove the tunable focal length of an RBC optouidic lens, we manage a dynamic experiment switching a single RBC between discocyte (mainly a negative lens) to spherocyte (a positive lens). Noteworthy, RBCs change shape in a reversible way by varying buffers osmolarity (see Methods). RBC sample, immersed in isotonic solution, is injected into a micro-channel. Soon after, a hypotonic solution is introduced causing, in about 10 s, signicant RBC swelling. Variation of the erythrocyte shape and consequent focal-length shifts are monitored in real time using the holographic microscope. Despite a discocyte being quite a complex lens, its focal length changes in a very clear way. Essentially, in a more accurate model, it is a lens having a strong spherical aberration. While the inner part (that is, for paraxial rays) has a negative focal length, the edges behave as a sort of toroid lens having a positive focal length for no-paraxial rays. The induced swelling of the RBC causes the substantial change of its shape, thus cancelling the central concavity. Consequently, the virtual focus (that is, negative focal spot) disappears completely while a reinforcement of the real focal spot occurs
The experimental results fully conrm this behaviour as shown in Fig. 1 and Supplementary Movie 1, where real-time measurements are compared with theoretical expectations, thus showing noteworthy agreement. In Fig. 1a, the diffraction propagation of the retrieved complex wavefront along the optical axis is reported. Wavefront is retrieved by numerical reconstruction of a real-time digital holographic recording during the experiment. The intensity distributions, in the transverse plane and along the optical axis (plane xz), show very distinctly that, for a spherocyte RBC, the virtual focal spot vanishes completely, while the discocyte is swelling (see Supplementary Movie 1). Focal-length change during RBC swelling is also conrmed by a wavefront Zernike analysis reported in Fig. 1 and Supplementary Movie 2, where Zernike shape tting (Fig. 1b) and principal Zernike coefcients (Fig. 1c) are calculated. It should be noted that, the theoretical trends of Zernike coefcients (left of Fig. 1c) show how the spherical aberration goes to zero; meanwhile focus shift is maximized. The same happens in the experimental case (right of Fig. 1c), for which virtual and real focal lengths of an RBC, that is, before and after its swelling, can be directly derived by Zernike coefcients. In particular, the RBC in Fig. 1 presents in this case virtual foci before the sample plane at about 7.4 mm
while its real focus, after hypotonic solution adding, is calculated at a distance of about 10.8 mm. Detailed model of discocyte RBC by Zernike polynomials is described in the Supplementary Methods 1; Supplementary Figs 1 and 2. We report in Fig. 1d only the simulated maximum intensity peak correspondent to the virtual focus. The entire simulation results on the light intensities distribution is shown in Supplementary Movie 3. In literature, the
2 NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2015 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502 ARTICLE
Plane of the RBC
Plane of the RBC
Osmolarity
Discocyte
model x
x
z axis
Real RBC
zernike fitting
y
15 m
Virtual focus
15 m
Discocyte
real
Spherocyte
model
Spherocyte
real
z axis
z axis
z axis
y
2 m
0 m
x
y
Real focus
x
y
Zernike coefficient a 4 a 12(%)
40 20
0
100
80 60 40 20
0
100 80 60
Focus shift a Spherical aberration a
Zernike coefficient a 4 a 12(%)
Time TimeFigure 1 | RBC behaves as a microlens. (a) The left part presents the phase-shifts in plane (xy) for a single RBC, simulated and real both discocyte and spherocyte. On the right, the correspondent light intensity distributions in the plane (xz), for a plane monochromatic wave propagating from the left through the cell, are reported. RBC behaves as a tunable lens passing from a virtual focus to a real one by changing buffer osmolarity. Scanning range along the z axis is between 15 and 15 mm. Supplementary Movie 1 shows this process in real time. (b) The two retrieved wavefronts obtained from real RBC
before and after swelling, while c reports, both theoretically and experimentally, the energy percentage of Zernike coefcients, during the hypotonic solution addition (during swelling spherical aberration goes to zero, meanwhile focus shift is maximized). Supplementary Movie 2 shows the Zernike-tting outputs and the focusing coefcients variation in real time. (d) Simulation results: in the top row are three simulated RBC shapes; in the bottom row the maximum intensity occurs for discocyte in the plane (xy) at a distance z 7 mm from the RBC plane. Scale bar 5 mm.
Light source
scattering theory3940 is considered for interaction of light with RBCs. However, the model described here is in the framework of geometrical optics and furnishes a good approximation of the interaction between light and the RBC lens.
RBC-biolens imaging properties. We performed a simple experimental test to demonstrate the imaging capability of an RBC. A spherocyte RBC is used to image a sub-micrometre pattern achieving an increased magnication of about 20%. For demonstrating the magnifying properties of the biolens in hypotonic solution, we inserted a piece of a digital versatile disc (DVD) (780 nm pitch) between the light source and the RBC, behaving as a biconvex lens. By considering the distance between the RBC and the grating xed at 16 mm, and by making the approximation that a spherocyte is a thin convergent lens, with focal length equal to 9 mm, we calculate a real image with magnication Mth 1.29. In Fig. 2a a schematic view of the experi
ment is showed. In Fig. 2b,c a comparison between a portion of the DVD grating and the same magnied portion seen through the biolens is reported. We observe an increase in the mumber of pixels (from 26 to 32) in the magnied image of one grating period, which corresponds to MexpE1.22, quite in agreement with the calculated value.
Successively, we have used OTs (see Methods) to manage the position in 3D of the RBC. Magnied image of the DVD grating is visible in the centre of the cell. Supplementary Movie 4 describes the whole raster-scanning process while the RBC lens is
moved rst vertically along the optical axis, then in the transversal plane. The distortion of the magnied lines of the grating is due to the spherical aberration of the lens (see Fig. 2c).
DVD grating
Magnified
DVD grating
RBC lens
780 nm
26 Pixels
32 Pixels
Figure 2 | RBC imaging properties. (a) Schematic view of the imaging test. A piece of a DVD is inserted as a test object between the light source and the RBC in hypotonic solution, the latter behaving as a biconvex lens. (b,c) Comparison between the grating and its magnied image thorough the biolens.
NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 3
& 2015 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502
These results demonstrate that RBC can behave as a tunable and optouidic lens, having an imaging capability.
Real-time blood screening through focal-spot aberrations. Once it is proved that an RBC can be seen as an optouidic microlens, it is possible to assert that any specic RBC morphology has its own focusing property. Since any blood disease has a typical shape, this implies that erythrocytes presenting more complicated shapes or deviations from normal healthy cases can be denitely identied by their focal spots, thus allowing blood disorder identication. In fact, any deviation from the healthy RBC morphology can be read as a sum of aberrations in the propagated optical wavefront passing through the cells, exactly as it occurs for any optical system. First, we analysed separately two different samples, made of hundreds of RBC, in two different osmolarity conditions. We performed numerous tests to get data from a statistical point of view, with the aim to estimate the focal-length ranges useful to determine the percentage of healthy cells in a crowded RBC ensemble. For the spherocyte ensemble, we measure real foci in front of the microlens array at a distance of about 9.72 mm while the discocyte ensemble presents virtual foci before the sample plane at about 6.33 mm. The corresponding
s.d. are 1.06 and 0.84 mm. The results are displayed in Fig. 3a,b. Viewing the RBC ensemble as an array of microlenses is, in principle, a very powerful diagnostic tool. In fact, by exploiting all the base concepts of IAO, an RBCs full 3D morphometry can be retrieved. The innovative diagnostic aspect is demonstrated in Figs 4 and 5 and Supplementary Movie 5. The all-optical-based analysis is performed illuminating the sample with monochromatic light, necessary to have a denite focusing effect that otherwise cannot be obtained (chromatic aberrations hinder the formation of sharp focal spots as displayed in Fig. 3c). It is important to note that no interferometry is required. A very fast pre-screening test is realized where the output establishes the percentage of healthy cells from the evaluation of the spot
ellipticity in the virtual focus plane. Results are reported in Fig. 4 and Supplementary Movie 5. Visualization of the spots and percentage of detected healthy and doubtful cells are furnished simultaneously, thanks to the test characteristic to be quasi real time. To validate the pre-screening process, we conducted a more sophisticated analysis based on the IAO27 to have deeper information on the real cell shape. The optical intensities in the plane behind the RBCs are recorded for the entire eld of view. For each intensity focal spot, an iterative Fourier transform algorithm calculate the wavefront aberrations where the output phase is modelled as a combination of Zernike polynomials making the assumption that only tilts, focus shift, spherical aberration, astigmatism and coma terms are present. Zernike coefcients for normal discocytes are essentially two, that is, focus shift and spherical aberration terms that justify the presence of the virtual focus in the plane before the RBC ensemble. Conversely, spherocytes present the focus coefcient several orders of magnitude higher than the others thus resulting in real foci.
Finally, abnormal shapes present the other coefcients with non-negligible values. Interestingly, the retrieved wavefront expressed by the Zernike polynomials can be used for full 3D morphological visualization under symmetry assumptions41 (see Fig. 5c). The approach presented can be applied to samples made of hundreds of cells supplying information on each RBC present in the ensemble as shown in Fig. 5. Detailed description of RBC shape retrieval is reported in the Supplementary Methods and Supplementary Figs 3 and 4. The approach can be proposed as an optics-based diagnostic tool. In fact, RBC focus-footprint is a clear and simple marker about its morphology for a fast easy pre-screening in vitro analysis. In fact, as shown in Fig. 4, the method is able to detect easily the percentage of normal discocytes in an ensemble by evaluating the number of spots and their ellipticity in the calculated virtual focal plane (z 6.33). In case the
percentage of discocytes (that is, healthy cells) is low with respect to an a-priori xed value, further and deeper analysis can
Gaussian fit f f = 9.72 m
Experimental data
7 8 9 10
Focal plane (m)
11 12
f
f = 6.33 m
Experimental data Gaussian fit
7.5 7
8 6
6.5
5.5
Focal plane (m)
5
Figure 3 | Focusing of an RBC ensemble. (a,b) Static test: phase-contrast reconstructions in the image plane and intensity reconstructions in average focal planes of two samples of RBCs in different osmolarity conditions and investigation of corresponding focusing properties. In both cases, RBCs are analysed to retrieve their focal lengths from which average and s.d. values are calculated (see histograms on the right). (c)Typical white-light images of an RBC sample in focus and out of focus. No sharp focal spots can be detected. Scale bar, 5 mm (for both images).
4 NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2015 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502 ARTICLE
100 80
Spots percentage (%)
100
80 60 40 20
0
100
80 60 40 20
0
Focalized spots HealthyDoubt
Spots percentage (%)
Spots percentage (%)
60
40 20
0
Figure 4 | RBC pre-screening process. (ac) Frames of Supplementary Movie 5 where a real-time RBCs pre-screening is performed, by analysing the intensity spots in the virtual focus plane (z 6.33 mm). Healthy discocytes correspond to a quasi-circular intensity spot (green); red spots correspond to
doubtful cases. The distinction between healthy and doubtful is obtained by evaluating the ratio between minor and major axes of a best-t ellipse of each spot (ellipticity). The healthiness level is considered 40.8. Blue histograms represent the number of RBCs detected, green and red ones are the percentage of healthy and doubtful cases, respectively. For each of the three frames, the correspondent intensity images are reported to validate the unambiguous relation between spots and cells.
Intensity patterns Retrieved wavefront 3D shapes
Figure 5 | RBCs shape retrieval from spot analysis. (a) Intensity patterns at the real focus plane. (b) For each spot, the corresponding wavefront is calculated to retrieve the phase distribution able to generate such intensity spots, which is computed by a combination of Zernike polynomials for each retrieved. The results for all the spots of the ensemble are displayed. (c) 3D morphology of two RBCs are shown.
be considered for retrieving abnormal RBC shapes by processing the spots intensities in the calculated real focal plane (z 9.72),
as demonstrated in the results of Fig. 5.
DiscussionIn this paper, RBCs are modelled as optouidic microlenses with well-dened optical properties. Experimental evidences, numerical simulations and nal practical application have been provided for this new concept. From the tunability experiment reported in Fig. 1 and the experimental results in Fig. 3, it is clear that spherocyte and discocyte have opposite concavities, therefore they focus laser light at real and virtual foci, behind and before the lens, respectively, thus conrming that an RBC can be considered as an optouidic lens able to change its focal length from negative to positive values. In ref. 42, the physical properties
(refractive index, shape and volume) of RBCs are characterized for several buffers osmolarities. We demonstrated here that the focal length depends also on the buffer chemistry and it is strictly related to such physical parameters. Therefore, in the tuning experiment, by dening the medium osmolarity, we control the nal stage of RBCs in terms of focal lengths. We demonstrated the magnifying properties of the RBC when it is employed as an active lens. Indeed, a grating with a pitch of 780 nm is imaged through the RBC lens resulting in a magnication of about 1.22. Moreover, by using OTs, the RBC lens is moved in three dimensions to scan a little part of the grating, thus behaving as a guided magnifying lens that can be foreseen as a sort of raster-scanning imaging inside the human body. Finally, a new paradigm is opened on biomedical application. In fact, by seeing RBCs as microlens array, there is the possibility to discriminate normal healthy cells from all other abnormal shapes
NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 5
& 2015 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502
by analysing optical focal spots with a monochromatic or quasi-monochromatic light source. We discuss and show that the method is fast and effective and allows for unambiguous identication of discocytes RBC from all the abnormal ones by evaluating the spots ellipticity in the virtual focus plane. Such a pre-screening procedure is based on the fact that normal discocyte biolenses present focus spots placed along the optical axis but in the opposite direction with respect to the abnormal ones. Furthermore, we prove that 3D RBC shape can be evaluated through the analysis of focal spots in the biolens forward focal plane. The presented approach is developed in analogy to wavefront aberration analysis by IAO, a well-known technology usually employed in astronomy as well as in optical communications and sensing. We demonstrate that focal spots are strictly correlated to the morphology as shown in Fig. 5. Consequently, future blood diagnosis can be achieved by abandoning the concept of diagnosis through classical imaging.
The concept demonstrated here is disruptively new. In fact, at the best of our knowledge, it is the rst time that a cell can be assumed as an active and tuneable lens. Experimental evidence of tunability, imaging and diagnostics reported here demonstrate in full the in vitro proof of principle. In our opinion, this could open the route for potential impacts either for future blood diagnostics and in vivo endoscopy. Recent improvement in biophotonics as the manipulation of RBCs from the outside of the vein16 and, at the same time, new papers on the miniaturization of OT on a single bre17,43,44 could convincingly lead to envisage an integration of the presented technique for endoscopy. For example, it could be investigated a bre-based system able to manipulate and trap RBCs inside the vein. The application could be the imaging of the RBC themselves to perform diagnosis. Indeed, by the same authors, the possibility to image a xed object hidden by a dense ow of RBCs has been recently proved45. In particular in the Fig. 4d of such paper xed RBCs are clearly visible thorough a dense layer of owing erythrocytes.
Concerning in vitro blood screening, the important improvement of the presented technique is that neither image segmentation nor traditional phase computing is required, thus resulting in quasi real-time output. In fact, as shown in Fig. 5, the analysis just needs the map of the focal spots to accomplish pre-screening. Thus the proposed technique could be able to easily detect blood disorders involving shape abnormalities, for example, sickle-cell disease, spherocytosis, elliptocytosis and malaria. Moreover, it is expected that the device for such a diagnostic tool could be adapted at lab-on-chip scale, because the optical set-up is very easy as it uses only a camera and a laser light source in the visible range that indeed nowadays are very compact and of low cost.
Methods
Sample preparation and isolation of erythrocytes. All experiments were done with heparinized blood drawn within the hour before use. Healthy blood was collected from one of the co-authors, who gave informed consent. The sample was prepared as follows: B3 ml of heparinized whole blood was withdrawn into a haematocrit tube. Blood was centrifuged at room temperature, for 15 min at 2,500 r.p.m. to separate it into its component parts (plasma, buffy coat and RBCs at the bottom of the centrifuge tube). The pellet (E1.5 ml) was collected and 100 ml of erythrocytes were diluted with a saline solution of 0.90% w/v of sodium chloride (NaCl) in sterile water up to a nal volume of 2 ml. The osmolarity of the medium was about 308 mOsm l 1 and it was isotonic with the membrane of
RBCs. No visible haemolysis occurred. For the hypotonic and hypertonic solutions, we used a medium osmolarity of about 205 and 410 mOsm l 1, respectively.
When RBCs are in a hypotonic environment, the cell interiors accumulate water that ows across the cell membrane into the cell, causing it to expand. On the contrary, when the environment is hypertonic, the cell eliminates water and shrinks. Finally, in an isotonic solution, water exchange between the cell and the environment is balanced, and no change in cell volume occurs. These situations are described in Supplementary Fig. 1, resulting in different shapes of the cells depending on the tonicity of the solution.
Digital holography and the OT apparatus. We integrate a microscope based on DH arrangement and an OT modulus to simultaneously image and manipulate biological samples31,34 (Fig. 6). The DH set-up is made by a 400 -mW at 532 nm bre-coupled laser that acts as a source for a MachZehnder interferometer
Object beam
Solid state
@ 532 nm
Reference beam
3 W
IR laser
MO
1001.25
CCD
IR filter
BS
SLM
Figure 6 | Optical experimental arrangement. DH-OT set-up for simultaneous imaging and trapping. DH set-up is based on a MachZehder interferometer where the object beam passes through the sample and then it is led to interfere with the reference beam by a Beam Splitter cube (BS). The interferograms are recorded by the camera (charge-coupled device (CCD)). The OT arrangement is realized by an infrared (IR) laser emitting at 1,064 nm. Multiple traps are managed by the spatial light modulator (SLM) inserted into the set-up following the standard 4f conguration. A lter is used to avoid the IR laser intensities that could be recorded during the experiments. Both DH and OT lasers paths are aligned in a 100x high-numerical aperture microscope objective (MO).
6 NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2015 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms7502 ARTICLE
(Fig. 6), whose main beam is directed into a customized inverted microscope equipped with an oil immersion 100 microscope objective, allowing bright-eld
imaging of the cells. The reference beam is recombined with the rst one by a beam splitter generating interference fringe patterns (called digital holograms) of the samples that are recorded by a 1,024 1,024 charge-coupled device camera (AVT
Technologies). The OT apparatus is realized by using a 3-W infrared laser source in combination with a Phase Only Spatial Light Modulator (by Holo-Eye), with the aim of trapping and moving multiple RBC lenses in 3D. In particular, the OT modulus is used to demonstrate the imaging properties of RBCs (Supplementary Movie 4). The trapping laser emits at 1,064 nm; the beam is expanded to t the aperture of the spatial light modulator operating in reection mode. Then, the laser beam is injected into the microscope objective (mumerical apperture 1.25)
thorough a standard 4f optical conguration (not shown for simplicity). RBCs (after separation from the other blood cells) are placed in a Petri dish and analysed by this apparatus.
References
1. Ford, J. Red blood cell morphology. Int. J. Lab. Hematol. 35, 351357 (2013).2. Khairy, K., Foo, J. J. & Howard, J. Shapes of red blood cells: comparison of 3D confocal images with the bilayer-couple model. Cell Mol. Bioeng. 1, 173181 (2008).
3. Lim, G., Wortis, M. & Mukhopadhyay, R. Stomatocytediscocyteechinocyte sequence of the human red blood cell: Evidence for the bilayercouple hypothesis from membrane mechanics. Proc. Natl Acad. Sci. USA 99, 1676616769 (2002).
4. Park, Y. K. et al. Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum. Proc. Natl Acad. Sci. USA 105, 1373013735 (2008).
5. Rappaz, B. et al. Measurement of the integral refractive index and dynamic cell morphometry of living cells with digital holographic microscopy. Opt. Express 13, 93619373 (2005).
6. Mavandadi, S. et al. A mathematical framework for combining decisions of multiple experts toward accurate and remote diagnosis of malaria using tele-microscopy. PloS ONE 7, 46192 (2012).
7. Yi, F., Moon, I., Javidi, B., Boss, D. & Marquet, P. Automated segmentation of multiple red blood cells with digital holographic microscopy. J. Biomed. Opt. 18, 026006 (2013).
8. Kim, K., Kim, K. S., Park, H. J., Ye, J. C. & Park, Y. K. Real-time visualization of 3-D dynamic microscopic objects using optical diffraction tomography. Opt. Express 21, 3226932278 (2013).
9. Kim, T. et al. White-light diffraction tomography of unlabelled live cells. Nat. Photon. 8, 256263 (2014).
10. Moon, I., Javidi, B., Yi, F., Boss, D. & Marquet, P. Automated statistical quantication of three-dimensional morphology and mean corpuscular hemoglobin of multiple red blood cells. Opt. Express 20, 1029510309 (2012).
11. Roma, P. M. S., Siman, L., Amaral, F. T., Agero, U. & Mesquita, O. N. Total three-dimensional imaging of phase objects using defocusing microscopy: Application to red blood cells. App. Phys. Lett. 104, 251107 (2014).
12. Ding, H. & Popescu, G. in Coherent Light Microscopy-Imaging and Phase Analysis (eds Ferraro, P., Wax, A. and Zalevsky, Z) Ch. 9 (Springer series in surface sciences) (Springer, 2010).
13. Jordan, P. et al. Creating permanent 3D arrangements of isolated cells using holographic optical tweezers. Lab Chip 5, 12241228 (2005).
14. Dholakia, K. & Cizmar, T. Shaping the future of manipulation. Nat. Photon. 5, 335342 (2011).
15. Grier, D. G. A revolution in optical manipulation. Nature 424, 810816 (2003).16. Zhong, M.-C., Wei, X.-B., Zhou, J.-H., Wang, Z.-Q. & Li, Y.-M. Trapping red blood cells in living animals using optical tweezers. Nat. Commun. 4, 1768 (2012).
17. Liberale, C. et al. in Lab-on-Fiber Technology Vol. 56 (eds Cusano, A., Consales, M., Crescitelli, A. & Ricciardi, A.) Ch. 8 (Springer Series in Surface Sciences) (Springer, 2015).
18. Psaltis, D., Quake, S. R. & Yang, C. Developing optouidic technology through the fusion of microuidics and optics. Nature 442, 381386 (2006).
19. Schmidt, H. & Hawkins, A. R. The photonic integration of non-solid media using optouidics. Nat. Photon. 5, 598604 (2011).
20. McLeod, E. & Ozcan, A. Nano-imaging enabled via self-assembly. Nano Today 9, 560573 (2014).
21. Lee, J. Y. et al. Near-eld focusing and magnication through self-assembled nanoscale spherical lenses. Nat. Lett. 460, 498501 (2009).
22. Dong, L., Agarwal, A. K., Beebe, D. J. & Jiang, H. Adaptive liquid microlenses activated by stimuli responsive hydrogels. Nat. Lett. 442, 551554 (2006).
23. McWhirter, J. L., Noguchi, H. & Gompper, G. Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries. Proc. Natl Acad. Sci. USA 106, 60396043 (2009).
24. Bambardekar, K., Dharmadhikari, A. K., Dharmadhikari, J. A., Mathur, D. & Sharma, S. Measuring erythrocyte deformability with uorescence, uid forces, and optical trapping. J. Biomed. Opt. 13, 064021 (2008).
25. Saraogi, V., Padmapriya, P., Apurba, P., Tatu, U. S. & Natarajan, V. Change in spectrum of Brownian uctuations of optically trapped red blood cells due to malarial infection. J. Biomed. Opt. 15, 037003 (2010).
26. Tycko, D. H., Metz, M. H., Epstein, E. A. & Grinbaum, A. Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. Appl. Opt. 24, 13551365 (1985).
27. Booth, M. J. Adaptive optics in microscopy. Philos. Trans. A Math. Phys. Eng. Sci. 365, 28292843 (2007).
28. Yu, L., Sheng, Y. & Chou, A. Three-dimensional light-scattering and deformation of individual biconcave human blood cells in optical tweezers. Opt. Express 21, 1217412184 (2013).
29. Fienup, J. R. Phase retrieval algorithms: a personal tour. Appl. Opt. 52, 4556 (2013).
30. Zernike, F. Beugungstheorie des Schneidenverfahrens und Seiner Verbesserten Form, der Phasenkontrastmethode. Physica 1, 689704 (1934).
31. Malacara, D. & DeVare, S. L. in Optical Shop Testing 2nd edn (ed. Malacara,D.Ch. 13, 455495 (Wiley Interscience, 1992).32. Miccio, L. et al. Direct full compensation of the aberrations in quantitative phase microscopy of thin objects by a single digital hologram. App. Phys. Lett. 90, 041104 (2007).
33. Miccio, L. et al. Tunable liquid microlens arrays in electrode-less conguration and their accurate characterization by interference microscopy. Opt. Express 17, 24872499 (2009).
34. Kemper, B. et al. in Handbook of Coherent-Domain Optical Methods. (ed. Tuchin, V. V.) Ch. 6 (Springer, 2013).
35. Merola, F. et al. Digital holography as a method for 3D imaging and estimating biovolume of motile cells. Lab Chip 13, 45124516 (2013).
36. Cardenas, N. & Mohanty, S. K. Optical tweezers assisted quantitative phase imaging led to thickness mapping of red blood cells. App. Phys. Lett. 103, 013703 (2013).
37. Cotte, Y. et al. Marker-free phase nanoscopy. Nat. Photon. 7, 113117 (2013).38. Miccio, L. et al. Particle tracking by full-eld complex wavefront subtraction in digital holography microscopy. Lab Chip 14, 11291134 (2014).
39. Lim, J. et al. Born approximation model for light scattering by red blood cells. Biomed. Opt. Express 2, 27842791 (2011).
40. Ding, H. F., Wang, Z., Nguyen, F., Boppart, S. A. & Popescu, G. Fourier transform light scattering of inhomogeneous and dynamic structures. Phys. Rev. Lett. 101, 238102 (2008).
41. Memmolo, P. et al. 3D morphometry of red blood cells by digital holography. Cytometry A 85, 10301036 (2014).
42. Park, Y. K. et al. Measurement of the nonlinear elasticity of red blood cell membranes. Phys. Rev. E 83, 051925 (2011).
43. Zeng, X., Smith, C. T., Gould, J. C., Heise, C. P. & Jiang, H. Fiber endoscopes utilizing liquid tunable-focus microlenses actuated through infrared light.J. Microelectromech. Syst. 20, 583593 (2011).44. Aljasem, K., Werber, A., Seifert, A. & Zappe, H. Fiber optic tunable probe for endoscopic optical coherence tomography. J. Opt. A Pure Appl. Opt. 10, 044012 (2008).
45. Bianco, V. et al. Imaging adherent cells in the microuidic channel hidden by owing RBCs as occluding objects by a holographic method. Lab Chip 14, 2499 (2014).
Author contributions
L.M., P.M., F.M. and F.P. conceived and designed the research and wrote the manuscript.
P.F. and P.A.N. supervised the project. F.M. and L.M. performed the experiments; P.M.
made all the numerical models and numerical analysis. All the authors revised the results
and the manuscript.
Additional information
Supplementary Information accompanies this paper at http://www.nature.com/naturecommunications
Web End =http://www.nature.com/
http://www.nature.com/naturecommunications
Web End =naturecommunications Competing nancial interests: The authors declare no competing nancial interests. Reprints and permission information is available online at http://npg.nature.com/reprintsandpermissions/
Web End =http://npg.nature.com/
http://npg.nature.com/reprintsandpermissions/
Web End =reprintsandpermissions/
How to cite this article: Miccio, L. et al. Red blood cell as an adaptive optouidic
microlens. Nat. Commun. 6:6502 doi: 10.1038/ncomms7502 (2015).
NATURE COMMUNICATIONS | 6:6502 | DOI: 10.1038/ncomms7502 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 7
& 2015 Macmillan Publishers Limited. All rights reserved.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Mar 2015
Abstract
The perspective of using live cells as lenses could open new revolutionary and intriguing scenarios in the future of biophotonics and biomedical sciences for endoscopic vision, local laser treatments via optical fibres and diagnostics. Here we show that a suspended red blood cell (RBC) behaves as an adaptive liquid-lens at microscale, thus demonstrating its imaging capability and tunable focal length. In fact, thanks to the intrinsic elastic properties, the RBC can swell up from disk volume of 90 fl up to a sphere reaching 150 fl, varying focal length from negative to positive values. These live optofluidic lenses can be fully controlled by triggering the liquid buffer's chemistry. Real-time accurate measurement of tunable focus capability of RBCs is reported through dynamic wavefront characterization, showing agreement with numerical modelling. Moreover, in analogy to adaptive optics testing, blood diagnosis is demonstrated by screening abnormal cells through focal-spot analysis applied to an RBC ensemble as a microlens array.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer