ARTICLE
Received 24 Jul 2015 | Accepted 22 Oct 2015 | Published 24 Nov 2015
Focusing light inside scattering media in a freely addressable fashion is challenging, as the wavefront of the scattered light is highly disordered. Recently developed ultrasound-guided wavefront shaping methods are addressing this challenge, albeit with relatively low modulation efciency and resolution limitations. In this paper, we present a new technique, time-reversed ultrasound microbubble encoded (TRUME) optical focusing, which can focus light with improved efciency and sub-ultrasound wavelength resolution. This method ultrasonically destroys microbubbles, and measures the wavefront change to compute and render a suitable time-reversed wavefront solution for focusing. We demonstrate that the TRUME technique can create an optical focus at the site of bubble destruction with a size of
B2 mm. We further demonstrate a twofold enhancement in addressable focus resolution in a microbubble aggregate target by exploiting the nonlinear pressure-to-destruction response of the microbubbles. The reported technique provides a deep tissue-focusing solution with high efciency, resolution, and specicity.
DOI: 10.1038/ncomms9968 OPEN
Optical focusing inside scattering media with time-reversed ultrasound microbubble encoded light
Haowen Ruan1,*, Mooseok Jang1,* & Changhuei Yang1
1 Department of Electrical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, California 91125, USA. * These authors contributed equally to this work. Correspondence and requests for materials should be addressed to H.R. (email: mailto:[email protected]
Web End [email protected] ) or to M.J.(email: mailto:[email protected]
Web End [email protected] ).
NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 1
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968
Creating an optical focus inside a scattering medium such as biological tissue has great potential in various applications. However, optical scattering, a dominant lightmatter
interaction within biological tissue, poses a very signicant challenge. Recent developed wavefront shaping techniques have begun to address this15 by exploiting the deterministic and time-symmetric nature of scattering. Focusing light through scattering media has been realized by iterative optimization methods2,6, optical phase conjugation (OPC)712, and direct measurement of the transmission matrix at large scale1315.
Determining the correct wavefront to focus light from outside of a scattering medium to a point within requires a feedback or tagging mechanism. Typically, these mechanisms arise from a localized guidestar point. Examples of guidestars include second harmonic generation16, uorescence17,18 and kinetic19,20 targets. While individual guidestars enable light shaped to focus to their physical location, these techniques fundamentally lack addressability if dense and randomly distributed sets of guidestars are present.
Alternatively, ultrasound-assisted techniques, such as photoacoustic-guided15,2123 and time-reversed ultrasonically encoded (TRUE)2427 optical focusing techniques, employ a focused ultrasound beam as a virtual guidestar. Unlike the above techniques, it is easy to move or scan an ultrasound focus to new positions. While TRUE has a speed advantage over the photoacoustic approach, the TRUE guidestar is generally weak and typically o1% of the probe light eld that passes through the ultrasound focus is tagged28,29. Moreover, the resolution achieved is limited by the ultrasound focus size. Although more advanced TRUE techniques, such as iterative TRUE3032 and time reversal of variance-encoded light33, may break this resolution barrier, it comes at the expense of time. For practical biological applications with tight time constraints, efcient and fast techniques are highly desired.
Here we present a high resolution, deep tissue optical focusing technique termed time-reversed ultrasound microbubble encoded (TRUME) optical focusing. Microbubbles have been widely used in ultrasonic imaging as ultrasound contrast agents because they generate stronger echoes and nonlinear acoustic signals compared with surrounding tissue34,35. Several other advantages of microbubbles are their small size compared with typical ultrasound wavelengths, which enables acoustic super-resolution imaging3638 and their ability to enable ultrasound modulated optical imaging inside scattering media3941. Furthermore, like uorescent markers, microbubbles can be modied to bind to selected biomarkers, suggesting promise for functional imaging and therapeutic applications34.
We demonstrate that the selective nonlinear destruction of microbubbles with a focused ultrasound beam can serve as effective, highly localized and freely addressable guidestar mechanism. In brief, TRUME works by measuring the scattered optical eld before and after the ultrasonic destruction of the microbubble. Subsequently, by playing back the phase conjugate version of the difference of these two elds, TRUME can generate a focus at the location of the destroyed microbubble. Although multiple foci could be created at the same time when multiple microbubbles are present within the original ultrasound focus, we show that careful selection of the ultrasound pressure can lead to destruction of microbubbles in an addressable volume that is smaller than the ultrasound focus. This is a result of the nonlinear pressure-to-destruction response curve associated with the microbubbles. This technique combines the advantages of both physical and virtual guidestars to provide efcient, fast and addressable deep tissue optical focusing.
ResultsPrinciples. Our TRUME set-up uses a digital OPC (DOPC) system as its wavefront recording and playback engine8,31
(Fig. 1a). In the recording phase, the scattered eld from the sample is recorded by the camera of the DOPC system. In the playback step, a phase-conjugated version of the recorded phase is displayed on the spatial light modulator (SLM) and a collimated blank beam is modulated to form the playback light eld. Precise alignment of the camera and SLM allows high delity phase conjugate playback of the record eld. Experimentally, this DOPC system is able to control B105 optical modes simultaneously42.
Here we demonstrate TRUME in transmission geometry (Fig. 1a), in which a sample beam transmits through the sample in the z direction and part of the scattered light is measured by the camera on the other side of the sample. An ultrasound beam is focused on the microbubbles embedded between two diffusers through water coupling. TRUME operates in three steps. First, an optical eld (Field A) is measured by the camera (Fig. 1b) with phase shifting digital holography43. Second (Fig. 1c), ultrasound is applied to destroy the targeted microbubble, immediately followed by the measurement of a second optical eld (Field B). The difference of the elds (Fields AB) is the scattered eld solution associated with the microbubble. The DOPC system computes this difference eld and plays back a phase conjugate copy. Since the difference eld primarily contains only information from the microbubble, the conjugated beam focuses to the position of the destroyed microbubble (Fig. 1d).
TRUME shares the same mathematical framework as guidestar techniques using kinetic objects19,20. The optical eld on the target plane Et can be decomposed into a microbubble diffracted eld Em and a background eld Eb, which describes the eld after microbubble destruction: Et Em Eb. Since the camera and
SLM contain discrete components, it is convenient to discretize Em and Eb as column vectors with n complex elements, with each element mapping to an optical mode on the two-dimensional target plane. We may then connect this target eld to the eld on the measurement plane E0t through a matrix equation:
E0t TEt T(Em Eb). Here T is an m n matrix describing
the scattering medium and E0t is a column vector of m elements, with each element mapping to an optical mode on the two-dimensional measurement plane. Similarly, the eld measured after microbubble destruction can be given by E0b TEb. The
difference eld on the measurement plane is thus,
E0dE0t E0b
T Em Eb
TEb TEm:
1
Here subtraction effectively removes the impact of the background eld on the measurement plane, resulting in a eld that appears to be scattered from the microbubbles only. Finally, we playback the conjugated eld E0 d with an optical gain a provided by the playback beam (Fig. 1a). Assuming time-reversal symmetry, we may express playback as a multiplication with T from the left with the conjugate transpose of the difference eld. Therefore, the playback eld Ep on the target plane takes the form:
Ep aE0 dT a TEm
T
aE mT T abE m:
2
Here we assume minimal absorption within the sample to apply the approximation T TEbI, in which b is the fraction of scattered light eld that is measured in the DOPC system and I is an identity matrix. The playback light effectively cancels out the random transmission matrix to refocus at the location of microbubble destruction.
The TRUME technique relies on a novel guidestar mechanism, popping a gas-lled microbubble using ultrasound, to generate
2 NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968 ARTICLE
the optical eld difference. This mechanism leverages both the optical and acoustic refractive index mismatch between gas and liquid to accomplish efcient conversion of acoustic signal to optical signal. Given the fact that microbubbles have excellent biocompatibility, this guidestar combines its advantages in optics, acoustics and biology to provide a solution for focusing light inside biological tissue.
Visualization and efciency characterization of the focus. To validate TRUME focusing, we directly visualized the target plane
using a 10 microscope system (see Methods section) before
and after the TRUME procedure. In this experiment, we shifted the front diffuser along the x direction (to the open position in Fig. 2a) for direct imaging of the target plane during the focusing phase. The target sample here is composed of microbubbles embedded in agarose gel within an acrylic capillary tube (see Methods section) as shown in Fig. 2b. Immediately after measuring the rst optical eld, a 20-MHz focused ultrasound beam was used to destroy one microbubble, followed by the measurement of the second eld. We then imaged the target plane again to conrm the destruction of the microbubble (Fig. 2c) and
Field A
Field B
Field difference
Camera
3
Reference beam
2
Ultrasound transducer
Diffusers
Playback beam
1
Phase
conjugation
Sample beam
SLM
Lens i ii
iii
x y
Beam splitters
DOPC
z
Tube
y
1
Microbubbles
2
3
x
Figure 1 | Principle of TRUME technique. (a) Illustration of the experimental set-up (see Supplementary Figs 1 and 2 for schematic diagram in detail). The microbubbles perfuse inside an acrylic tube, which is sandwiched between two diffusers. A DOPC system is used as a phase conjugation mirror to time-reverse the light back to the sample. (bd) Illustration of TRUME optical focusing technique in three steps. At the rst step, the camera of the DOPC system captures a transmitted optical eld (Field A) before applying ultrasound to the sample (b). Ultrasound bursts are then used to destroy the targeted microbubble (c), resulting in a different optical eld (Field B). The difference between two elds yields an optical eld that appears to emerge from the destroyed microbubble. The conjugated phase of the difference eld is then sent to the SLM to create a playback beam, which focuses light at the position of microbubble destruction (d). Yellow arrows, numbers and signal ows indicate recording process; green ones represent playback.
a
Open position
Objective
64 k
0
DOPC
32 k
x y z
y
x
TRUME TRUE
Figure 2 | Visualization of the target plane. (a) Illustration of the observation set-up. The front diffuser was shifted to the open position before and after TRUME for direct visualization. A 10 microscope system was used to observe the target plane. (b,c) Images of a microbubble before and after applying
ultrasound. (d) Optical focus created at the position of microbubble destruction. (e) Focusing results of TRUE technique. Scale bar, 10 mm.
NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 3
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968
directly visualized the focus created at the position of destroyed microbubble (Fig. 2d). The measured peak intensity to background intensity ratio (PBR) of the TRUME focus in Fig. 2d is B510 (Supplementary Methods).
For comparison, we also measured the focusing prole of TRUE (Fig. 2e and Supplementary Methods). The PBR of the TRUME focus is around two orders of magnitude higher than that of TRUE (PBR B2 in Fig. 2e), since the TRUME
concentrates light at fewer optical modes and has a stronger modulation efciency per mode.
We separately measured the modulation efciency of ultra-sound in a clear medium (Supplementary Fig. 3 and Supplementary Methods), and found that B0.5% of light passing through the ultrasound focus (2 MPa peak pressure) is modulated. In comparison, the proportion of light passing through the location of the bubble that is modulated by bubble destruction reaches B25% (Supplementary Fig. 3). This large difference in modulation efciency is the primary reason why the TRUME guidestar offers a stronger focus.
Deep tissue optical focusing. To study the performance of TRUME for focusing through biological tissue, we used two pieces of 2-mm-thick biological tissue as our diffusive medium (see Methods section). The experimental set-up matches that shown in Fig. 2a. The images of the microbubble before and after destruction are shown in Fig. 3a,b. We directly observed the target plane (Fig. 3ce) after the TRUME process. An optical focus (Fig. 3c,e) was created using TRUME, with PBR of B23 (Supplementary Methods). Fitted Gaussian proles (to the one-dimensional data through the centre of the focus in the x and y directions) show the focus full width at half maximum (FWHM; Fig. 3e) is 2.40.2 mm in the x direction and 1.70.2 mm in the y direction (95% condence bounds). To conrm that this optical focus was created due to OPC, we shifted the SLM phase pattern in both x and y directions by 10 pixels. As shown in Fig. 3d, the optical focus vanishes as expected. The optical elds measured before and after microbubble destruction, as well as the subtracted eld, are shown in Fig. 3fh, respectively.
Demonstration of ow stream monitoring. One application of the TRUME focusing technique may be to perform cytometry behind a scattering media by using microbubbles, which are currently used as contrast agents in blood circulation ultrasound imaging34. To demonstrate this potential application (Fig. 4a), we
mixed uorescent microspheres (4 mm) and microbubbles in 1X phosphate buffered saline and pumped the solution through an acrylic tube (see Methods section). We rst formed an optical focus, as shown in Fig. 4b, by implementing the TRUME technique to focus on a microbubble at the target location. Fluorophores that subsequently ow across the focus then interact with the focused light spot to emit uorescence. The uorescence was ltered with an emission lter and detected by a single-photon-counting module outside the scattering medium (see Methods section). The resulting signal is shown in Fig. 4c. After counting, the front diffuser was shifted to the open position and the uorescent microspheres were imaged with an emission lter for verication (Fig. 4d). The agreement of the results positively validates this proof-of-concept.
Addressable focus resolution improvement. Our demonstrations of TRUME thus far destroy an isolated microbubble with a relatively large ultrasound focus (one to two orders of magnitude larger), forming one sharp optical focus. If multiple microbubbles are clustered together, then the ultrasound focus may destroy more than one bubble. In this scenario, TRUME will generate an optical focus signicantly broader than the focus we have discussed thus far. To distinguish the two focus types, we will use the term addressable focus to refer to the achievable TRUME focus in the scenario where microbubbles are dense.
The addressable focus size is statistically determined by the pressure-to-destruction response of the bubbles. Interestingly, the probability of microbubble destruction varies nonlinearly as a function of pressure. In the ideal case where all microbubbles have the same destruction threshold, one can set the peak ultrasound pressure to be right at the threshold so that only the microbubble at the centre of the ultrasound focus will be destroyed and therefore obtain an addressable focus size that is equal to the single bubble TRUME focus size. In practice, however, the actual pressure-to-destruction response curve is not a simple step function. Nevertheless, the more nonlinear the response curve is, the sharper addressable focus we can achieve with TRUME.
To better characterize the pressure-to-destruction response and determine the TRUME addressable focus resolution achievable with our system, we experimentally measured the cumulative distribution function of the microbubble destruction s(P) by counting the number of microbubbles destroyed as a function of pressure (Supplementary Fig. 4 and Supplementary Methods). As
104
102
1.7 0.2 m
100
64 k
32 k
0
2.4 0.2 m
Figure 3 | Optical focusing in 2-mm-deep chicken tissue. Two pieces of 2-mm-thick chicken tissues were used as diffusers. (a) A microbubble in a tube before destruction. (b) After destruction. (c) A light focus was created at the position of the destroyed microbubble (PBR B23). (d) The optical focus vanished as the SLM shifts 10 pixels in both x and y directions. (e) 10X zoom-in image of the optical focus with quantied resolution. (f,g) Central part (200 pixels by 200 pixels) of the optical elds captured before (f) and after (g) the destruction of the microbubble. (h) Difference of the elds in f,g. Scale bar, 10 mm.
4 NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968 ARTICLE
shown in Fig. 5a (red), the cumulative distribution function reveals a strong nonlinear relationship between destruction probability and pressure. Given a focused ultrasound prole P(x) (Fig. 5a, green; see also Methods section), we were able to calculate the microbubble destruction probability over position s(P(x)) (Fig. 5a, blue), which predicts the addressable focus resolution of TRUME. The resulting prole is signicantly
narrower than the ultrasound pressure prole, implying that the nonlinear relationship would effectively improve the addressable focus resolution of TRUME.
To experimentally conrm the improvement of addressable focus resolution of TRUME, we used a thin microbubble sheet (see Methods section) to visualize the distribution of the foci as ultrasound pressure increases. To cover the entire ultrasound
255
128
0
255
128
0
APD counts
Lens
DOPC
0 10 20
104 2
1
0
Emission filtery
z
Time (s)
Fluorescent microspheres
x
y
Photodetector
x
Figure 4 | Demonstration of ow stream monitoring through a scattering sample. (a) Illustration of the experimental set-up. An external single-photon-counting module (SPCM) was used to detect the excited uorescence through the uorescence lter. (b) A light focus was created with TRUME.(c) Photon counts recorded by the SPCM as the optical focus probed the owing microspheres. (d) Image of the uorescent microspheres after passing through the optical focus in the x direction. Scale bar, 10 mm.
Position, x (m)
1
8.7
5.2
0.75
Probability of microbubble
destruction, [afii9846]
0.2
0.15
0 0 0.5 1.0 1.5 2.0 50 25
0.5
0.1
0.25
0
Cumulative probability of microbubble destruction, [afii9846](P )
Pressure profile, P(x )
Destructed microbubble distribution, [afii9846](P(x ))
0.05
Pressure, P (MPa)
0 25
50 0 1.5 3.0 4.5 6.0
y
x
2.2
(MPa)
Lateral Axial Lateral Axial
1.0
00.2
Measured P
Measured [afii9846] Gaussian fit of [afii9846]
50
0.8
0
1.0
0.6
.88
.2
0.8
0.2
300
40
FWHM (m)
.6
.
0
30
200
0.4
0.4
0.4
.4
20
100
0.2
10
Pressure profile P Measured [afii9846]
Predicted [afii9846]
0 0 2
50
25
300
200
100
25
50
100
200
300
4
6 8
0 0 2
4
6 8
Peak pressure (MPa)
Peak pressure (MPa)
Position, x (m)
Position, y (m)
Theoretical P
Figure 5 | Addressable focus resolution improvement by exploiting nonlinear microbubble destruction. (a) Calculation of microbubble destruction probability distribution over position (blue) based on the measured cumulative distribution function of the microbubble destruction s(P) (red) and the theoretical ultrasound pressure prole P(x) (green). (b) Two-dimensional distribution map of TRUME foci over pressure levels. This distribution map aggregates centroids of the TRUME foci from 135 sets of data. (c) Comparison of the TRUME focus probability distribution (histograms, with Gaussian t) and the ultrasound pressure prole (green) in both lateral (left) and axial (right) directions. The histograms were calculated from the low-pressure map (left gure in b). (d) Theoretical (for example, FWHM of the blue curve in a) and experimental (for example, FWHM of the blue curve in c) TRUME addressable focus resolution over pressure. Green lines mark the FWHM of the ultrasound prole. Error bar indicates 95% condence bounds. Scale bar in b, 50 mm.
NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 5
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968
focus ( 6 dB) with the current observation system and further
improve the resolution, we used a 45-MHz, high numeric-aperture ultrasound beam with a measured beam diameter of B40 mm and focal zone of B270 mm ( 6 dB; see Methods
section) in this experiment (see Supplementary Fig. 5 for the experimental results using 20 MHz ultrasound). We applied 15 levels of ultrasound pressure (linearly from 1.7 to 8.7 MPa) to the sample and measured the elds before and after each insonation. We then played back the corresponding eld difference sequentially, recorded the resulting focus patterns (Supplementary Fig. 6), and applied a watershed algorithm to extract each focus centroid (see Methods section). To collect meaningful statistics, this process was repeated 135 times at different unaffected regions of the microbubble sheet. We aggregated the measured TRUME focus centroids into a statistical map as shown in Fig. 5b, where foci are displayed in three pressure groups. The prole of the foci broadens as the ultrasound pressure becomes higher, conrming the nonlinearity effect in TRUME.
To quantify the addressable focus resolution improvement, we calculated the FWHM of Gaussian proles that are tted to the histograms of each statistical map along both lateral (x) and axial (y) directions. Figure 5c shows the Gaussian ts and histograms of the lower pressure group (o2.2 MPa, Fig. 5b, left) where microbubbles start to collapse. We also measured the ultrasound pressure proles, which closely match with their theoretical proles in both directions (see Methods section). The FWHM of the Gaussian t to the centroid histogram in the lateral (x) direction is 19 mm, while that of theoretical ultrasound focus is 40 mm. Likewise, the FWHM of the TRUME addressable focus along the axial (y) direction is 130 mm, which is also lower than that of the ultrasound focus (270 mm). We further studied the effect of ultrasound pressure on the nonlinearity-induced resolution improvement by calculating the FWHMs of the Gaussian ts of both the theoretical microbubble destruction distribution (for example, blue curve in Fig. 5a) and TRUME focus histogram proles (for example, blue curve in Fig. 5c) at various pressure levels. As shown in Fig. 5d, both experimental and theoretical FWHMs are lower than that dened by the ultrasound focus (green line) when the ultrasound pressure is oB5 MPa. The discrepancy between these two curves is attributable to variations between the samples.
DiscussionCombining the advantages of a physical and a virtual guidestar, TRUME can selectively focus light to a size of B2 mm in deep tissue, given the distribution of microbubbles it targets is sufciently sparse. When the microbubble distribution is dense, we show that TRUME may still achieve an addressable focus resolution B2 times higher than that dened by its ultrasound focus. As this method simply requires two measurements and no iterations, it is intrinsically fast and a good match with in vivo applications. Next, we list several factors that affect TRUME performance and outline several of its potential applications.
The size of an individual focus depends on that of the microbubble that is typically at micrometre scale, approximately tenfold smaller than a TRUE focus. Although ultrasound focus could cover multiple microbubbles, TRUME further connes the targeting range by taking the advantage of the nonlinear relationship between microbubble destruction probability and ultrasound pressure. The addressable focus resolution improvement was largely limited by the broad size distribution of the microbubbles, and thus can be enhanced by reducing the standard deviation of the radius of microbubbles, via separation techniques44 or methods based on established protocols45,46.
Alternatively, simultaneously focusing to multiple microbubble locations might also be a desired experimental goal, like when using microbubbles as selective markers (for example, binding to certain disease markers)34.
The PBR of TRUME is measured to be two orders of magnitude greater than that of TRUE (B510 versus B2, using a ground glass diffuser sample and the set-up in Fig. 2). Two factors lead to this large PBR increase. First, TRUME practically encodes signicantly fewer optical modes, even if multiple microbubbles are present within the ultrasound focus. Second, the modulation efciency of TRUME is much higher than TRUE. In our experiment, we found B25% modulation of the light passing through the TRUME guidestar. In comparison, a TRUE guidestar with a peak pressure of 2 MPa only modulates B0.5%
of its contained light.
The time needed to destroy a microbubble depends on the mechanisms of microbubble destruction, which can be classied into fragmentation and diffusion47. Fragmentation occurs when ultrasound pressure is relatively high and the microbubble is destroyed on a timescale of microseconds, which suggests the TRUME mechanism is likely applicable to in vivo tissue experiments. In the case where low ultrasound pressure is used, acoustic driven diffusion is the dominant destruction mechanism. This process typically spans tens of microseconds, depending on both the ultrasound parameters (pressure, frequency, cycles and so on) and microbubbles properties (size, shell material and encapsulated gas)47. In this paper, the ultrasound pulse duration was 28.6 ms (one camera frame period), within which incomplete gas dissolution was also observed under certain circumstances, such as with low ultrasound pressure and a large microbubble diameter (Supplementary Movies 13). This effect results in a size decrease rather than complete disappearance of the microbubble. Intriguingly, decreasing the size of the microbubble between capturing two optical elds also enables TRUME to form an optical focus at the targeted microbubble (Supplementary Fig. 7 and Supplementary Note 1), because it shares the same effect as the complete microbubble destructioninducing difference between two optical elds.
It should be noted that the lifetime of a TRUME focus depends on the tissue decorrelation time. To achieve a longer focusing duration, one may need to use the incomplete destruction approach. In this case, the TRUME focus can be repeatedly created by decreasing the size of the microbubble each time until complete destruction. Alternatively it is also possible to dynamically maintain the optical focus by using the ultrasound-driven microbubble oscillation effect48, which is also able to induce optical eld variation.
Taking advantage of parallel eld measurement, this DOPC-based technique creates optical foci in hundreds of milliseconds (B280 ms in our experiments), a timescale short enough for ex vivo or even some in vivo biological applications with appropriate tissue immobilization methods49. It should be noted that no frame averaging was needed for any of our TRUME experiments. Like other eld subtraction approaches, the background elds need to remain highly correlated as the light intensity fraction encoded by the microbubble is typically very small. This requirement suggests that we must capture the two elds in a sufciently short time period to overcome in vivo tissue decorrelation given that microbubbles can induce eld variation during this time interval. Technically, this can be achieved by using a high speed camera. Off-axis holography-based eld measurement or binary phase measurement would further improve the system speed by reducing the number of frames needed for eld measurement11,50.
Microbubbles are usually made with albumin or lipid, which stabilizes high molecular weight gases, such as perutren.
6 NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968 ARTICLE
Microbubbles like these have been widely used as ultrasound contrast agents and proven for some applications in the human body. Their biocompatibility makes them a promising optical guidestar in biological tissue. Besides ultrasonic imaging, micro-bubbles also have promising applications in gene and drug delivery51, where their ultrasonic destruction can release a therapeutic payload. Furthermore, microbubbles can also be targeted to regions of disease by surface conjugation of specic ligands or antibodies, which bind to the disease markers34. Recently, genetically encoded gas nanostructures from microorganisms have been demonstrated as a promising candidate as molecular reporters52. All these applications imply that microbubbles have high specicity and selectivity, with which TRUME focusing may provide precise optical mediation for drugs, cells or molecules. Example applications range from selective photo-thermal therapy for targeting tumour cells53,54 to specic light delivery in optogenetics55.
The prospect of using TRUME to perform imaging is less obvious and deserves some elaboration. Like other physical guidestar assisted wavefront shaping techniques, the TRUME focus position is collocated with the physical guidestar location and cannot be freely repositioned to perform raster scans. TRUME may potentially be combined with a newly described optical memory effect56 to perform scanning and imaging. Specically, it has been demonstrated that lateral translation of the input optical wavefront can retain some of its focusing ability through scattering media with high scattering anisotropy. TRUME can potentially be used to generate the initial focus that can then be freely scanned within a small proximal region using this optical memory effect.
Methods
Set-up. The TRUME experiment was carried out in a custom-built set-up. The schematic diagram of the set-up is illustrated in Supplementary Fig. 1. A pulsed laser beam (532 nm wavelength, 7 ns pulse width, 20 kHz repetition rate and 7 mm coherent length) generated from a Q-switch laser (Navigator, Spectra-Physics) was spilt into three beams: a sample beam, a reference beam and a playback beam. Both of the sample beam and the reference beam were shifted by 50 MHz using an acousto-optical modulator (AFM-502-A1, IntraAction). The interference between the transmitted sample beam and reference beam was measured by the camera (PCO.edge, PCO) of the DOPC system. The playback beam was modulated with the conjugated phase of the subtracted eld by an SLM (Pluto, Holoeye), which was precisely aligned to the camera through a beam splitter.
The 20-MHz ultrasound burst was generated by a transducer with a 12.7-mm focal length and 6.35 mm element diameter (V317, Olympus), and the 45-MHz ultrasound burst was generated by a transducer that has a 6-mm focal length and6.35 mm element diameter (nominal frequency at 50 MHz, calibrated peak frequency at 44.4 MHz, V3330, Olympus). Both transducers were driven by a RF power amplier (30W1000B, Amplier Research).
To directly visualize the results, a custom-built microscope with a 20
objective (SLMPlan N, Olympus) and a tube lens of 100 mm focal length was used to image the target plane to a charge-coupled device camera (Stingray F145, Allied Vision Technologies). To demonstrate the cytometry application, the uorescent signals were ltered by a 561-nm long-pass (LP02-561RE-25, Semrock) and a 582/75-nm band-pass lter (FF01-582/75-25, Semrock) and detected by a single-photon-counting module (SPCM-AQRH-14, Perkinelmer).
Signal ow. The signal ow is shown in detail in Supplementary Fig. 2. The sample beam and reference beam were modulated by 50 MHz signals generated from two channels of a function generator (AFG 3252, Tektronix). The optical eld transmitted through the sample was measured by the camera (exposure time:20 ms, framerate: 35 fps) of the DOPC system using 4-phase shifting-based digital holography43. The phase shifting was synchronised with the camera exposure by controlling signals from a data acquisition card (PCI-6281, NI). The ultrasound burst signal (10 cycles, 10 ms interval) was generated by another function generator (4065, BK Precision) and time-gated (28.6 ms) by the data acquisition card.
Sample preparation. The microbubbles (Optison, GE health care) was diluted to 10% (v/v%) in 1% (w/w%) agarose gel in aqueous phase or 1X phosphate buffered saline (demonstration of ow stream monitoring) and perfused in an acrylic capillary tube (inner diameter: 50 mm, outer diameter: 100 mm, Paradigm Optics), which was positioned inside a clear polystyrene cuvette. Polyacrylamide gel (10%)
was used to ll the space in the cuvette to secure the capillary tube. Two diffusers (10 10 mm, 220 grit ground glass, Edmund Optics) were placed outside the
cuvette in parallel with B10 mm distance in between. The microbubble sheet was B20 mm thick and sandwiched between two blocks of agarose gel with dimensions of 10 mm (x) 10 mm (y) 3 mm (z). The microbubble sheet was positioned
between and parallel to the diffusers. The ultrasound beam was aligned to the microbubble sheet by maximizing the amplitude of the echo received from the focus.
In the ow stream monitoring experiment, uorescent microspheres with 4 mm diameter (FluoSpheres 580/605, Life Science) were used as targets. In the ex vivo tissue experiment, fresh chicken breast tissue was used as diffusive medium. For each tissue diffuser, a piece of 2-mm-thick chicken breast tissue slice (10 mm(x) 10 mm (y)) was sandwiched between two pieces of cover glass separated by a
2-mm spacer.
Ultrasound beam characterization. We calculated the theoretical ultrasound pressure eld using the fast near-eld method57. We rst calculated the pressure elds at different single frequencies ranging from 1 to 100 MHz, and summed the proles with a weight accounting for transducer response and frequency spectrum of ultrasound pulse train.
The ultrasound pressure was measured in room temperature water using a calibrated hydrophone (HGL-0085, Onda). To characterize the prole of the ultrasound beam, we operated the transducer in pulse-echo mode using a pulser-receiver (5900PR, Olympus) and scanned a line target (air lled polycarbonate tube, inner diameter 22.5 mm, outer diameter 25 mm, Paradigm Optics) by translating the transducer in the lateral and axial direction, respectively58. This method provides a more accurate measurement than using the hydrophone because the active diameter of the hydrophone is larger than the waist of the ultrasound beam generated by the V3330 transducer. The peakpeak voltages of the echoes were measured by an oscilloscope (DPO 3012, Tektronix). Because the measurement was based on single cycle burst, side lobes were not shown.
Watershed algorithm. We rst binarized the image with a threshold that was seven times higher than the background intensity. This step outputs a binary image in which only the pixels around the peak have the value of 1. We then segmented the binary image with a watershed algorithm and extracted the centroid of each focal spots.
References
1. Mosk, A. P., Lagendijk, A., Lerosey, G. & Fink, M. Controlling waves in space and time for imaging and focusing in complex media. Nat. Photon. 6, 283292 (2012).
2. Vellekoop, I. M. Feedback-based wavefront shaping. Opt. Express 23, 1218912206 (2015).
3. Kim, M., Choi, W., Choi, Y., Yoon, C. & Choi, W. Transmission matrix of a scattering medium and its applications in biophotonics. Opt. Express 23, 1264812668 (2015).
4. Yu, H. et al. Recent advances in wavefront shaping techniques for biomedical applications. Curr. Appl. Phys. 15, 632641 (2015).
5. Horstmeyer, R., Ruan, H. & Yang, C. Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue. Nat. Photon. 9, 563571 (2015).
6. Vellekoop, I. M. & Mosk, A. P. Focusing coherent light through opaque strongly scattering media. Opt. Lett. 32, 23092311 (2007).
7. Yaqoob, Z., Psaltis, D., Feld, M. S. & Yang, C. Optical phase conjugation for turbidity suppression in biological samples. Nat. Photon. 2, 110115 (2008).
8. Cui, M. & Yang, C. Implementation of a digital optical phase conjugation system and its application to study the robustness of turbidity suppression by phase conjugation. Opt. Express 18, 34443455 (2010).
9. Papadopoulos, I. N., Farahi, S., Moser, C. & Psaltis, D. Focusing and scanning light through a multimode optical ber using digital phase conjugation. Opt. Express 20, 1058310590 (2012).
10. Hillman, T. R. et al. Digital optical phase conjugation for delivering two-dimensional images through turbid media. Sci. Rep. 3, 1909 (2013).
11. Wang, D. et al. Focusing through dynamic tissue with millisecond digital optical phase conjugation. Optica 2, 728735 (2015).
12. Lee, K., Lee, J., Park, J.-H., Park, J.-H. & Park, Y. One-wave optical phase conjugation mirror by actively coupling arbitrary light elds into a single-mode reector. Phys. Rev. Lett. 115, 153902 (2015).
13. Popoff, S. M. et al. Measuring the transmission matrix in optics: an approach to the study and control of light propagation in disordered media. Phys. Rev. Lett. 104, 100601 (2010).
14. Yu, H. et al. Measuring large optical transmission matrices of disordered media. Phys. Rev. Lett. 111, 153902 (2013).
15. Chaigne, T. et al. Controlling light in scattering media non-invasively using the photoacoustic transmission matrix. Nat. Photon. 8, 5864 (2013).
16. Hsieh, C., Pu, Y., Grange, R. & Psaltis, D. Digital phase conjugation of second harmonic radiation emitted by nanoparticles in turbid media. Opt. Express 18, 533537 (2010).
NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 7
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms9968
17. Vellekoop, I. M., Cui, M. & Yang, C. Digital optical phase conjugation of uorescence in turbid tissue. Appl. Phys. Lett. 101, 081108 (2012).
18. Katz, O., Small, E., Guan, Y. & Silberberg, Y. Noninvasive nonlinear focusing and imaging through strongly scattering turbid layers. Optica 1, 170174 (2014).
19. Zhou, E. H., Ruan, H., Yang, C. & Judkewitz, B. Focusing on moving targets through scattering samples. Optica 1, 227232 (2014).
20. Ma, C., Xu, X., Liu, Y. & Wang, L. V. Time-reversed adapted-perturbation (TRAP) optical focusing onto dynamic objects inside scattering media. Nat. Photon. 8, 931936 (2014).
21. Kong, F. et al. Photoacoustic-guided convergence of light through optically diffusive media. Opt. Lett. 36, 20532055 (2011).
22. Caravaca-Aguirre, A. M. et al. High contrast three-dimensional photoacoustic imaging through scattering media by localized optical uence enhancement. Opt. Express 21, 2667126676 (2013).
23. Lai, P., Wang, L., Tay, J. W. & Wang, L. V. Photoacoustically guided wavefront shaping for enhanced optical focusing in scattering media. Nat. Photon. 9, 126132 (2015).
24. Xu, X., Liu, H. & Wang, L. V. Time-reversed ultrasonicallyencoded optical focusing into scattering media. Nat. Photon. 5, 154157 (2011).
25. Wang, Y. M., Judkewitz, B., DiMarzio, C. A. & Yang, C. Deep-tissue focal uorescence imaging with digitally time-reversed ultrasound-encoded light. Nat. Commun. 3, 928 (2012).
26. Si, K., Fiolka, R. & Cui, M. Fluorescence imaging beyond the ballistic regime by ultrasound pulse guided digital phase conjugation. Nat. Photon. 6, 657661 (2012).
27. Ma, C., Xu, X. & Wang, L. V. Analog time-reversed ultrasonically encoded light focusing inside scattering media with a 33,000 optical power gain. Sci. Rep. 5,
8896 (2015).28. Jang, M., Ruan, H., Judkewitz, B. & Yang, C. Model for estimating the penetration depth limit of the time-reversed ultrasonically encoded optical focusing technique. Opt. Express 22, 57875807 (2014).
29. Kothapalli, S.-R. & Wang, L. V. Ultrasound-modulated optical microscopy.J. Biomed. Opt. 13, 054046 (2008).30. Si, K., Fiolka, R. & Cui, M. Breaking the spatial resolution barrier via iterative sound-light interaction in deep tissue microscopy. Sci. Rep. 2, 748 (2012).
31. Ruan, H., Jang, M., Judkewitz, B. & Yang, C. Iterative time-reversed ultrasonically encoded light focusing in backscattering mode. Sci. Rep. 4, 7156 (2014).
32. Suzuki, Y., Tay, J. W., Yang, Q. & Wang, L. V. Continuous scanning of a time-reversed ultrasonically encoded optical focus by reection-mode digital phase conjugation. Opt. Lett. 39, 34413444 (2014).
33. Judkewitz, B., Wang, Y. M., Horstmeyer, R., Mathy, A. & Yang, C. Speckle-scale focusing in the diffusive regime with time-reversal of variance-encoded light (TROVE). Nat. Photon. 7, 300305 (2013).
34. Lindner, J. R. Microbubbles in medical imaging: current applications and future directions. Nat. Rev. Drug Discov. 3, 527532 (2004).
35. Goertz, D. E. et al. High frequency nonlinear B-scan imaging of microbubble contrast agents. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 6579 (2005).
36. Viessmann, O. M., Eckersley, R. J., Christensen-Jeffries, K., Tang, M. X. & Dunsby, C. Acoustic super-resolution with ultrasound and microbubbles. Phys. Med. Biol. 58, 64476458 (2013).
37. OReilly, M. A. & Hynynen, K. A super-resolution ultrasound method for brain vascular mapping. Med. Phys. 40, 110701 (2013).
38. Desailly, Y., Couture, O., Fink, M. & Tanter, M. Sono-activated ultrasound localization microscopy. Appl. Phys. Lett. 103, 174107 (2013).
39. Benchimol, M. J. et al. Phospholipid/Carbocyanine Dye-Shelled Microbubbles as Ultrasound-Modulated Fluorescent Contrast Agents. Soft Matter 9, 23842388 (2013).
40. Liu, Y., Feshitan, J. A., Wei, M.-Y., Borden, M. A. & Yuan, B. Ultrasound-modulated uorescence based on uorescent microbubbles. J. Biomed. Opt. 19, 085005 (2014).
41. Ruan, H., Mather, M. L. & Morgan, S. P. Ultrasound modulated optical tomography contrast enhancement with non-linear oscillation of microbubbles. Quant. Imaging Med. Surg. 5, 916 (2015).
42. Jang, M., Ruan, H., Zhou, H., Judkewitz, B. & Yang, C. Method for auto-alignment of digital optical phase conjugation systems based on digital propagation. Opt. Express 22, 1405414071 (2014).
43. Yamaguchi, I., Matsumura, T. & Kato, J.-I. Phase-shifting color digital holography. Opt. Lett. 27, 11081110 (2002).
44. Shekhar, H., Rychak, J. J. & Doyley, M. M. Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging. Med. Phys. 40, 082903 (2013).
45. Pancholi, K. P., Farook, U., Moaleji, R., Stride, E. & Edirisinghe, M. J. Novel methods for preparing phospholipid coated microbubbles. Eur. Biophys. J. 37, 515520 (2008).
46. Palanchon, P., Klein, J. & de Jong, N. Production of standardized air bubbles: application to embolism studies. Rev. Sci. Instrum. 74, 25582563 (2003).47. Chomas, J. E., Dayton, P., Allen, J., Morgan, K. & Ferrara, K. W. Mechanisms of contrast agent destruction. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 48, 232248 (2001).
48. Thomas, D. H., Sboros, V., Emmer, M., Vos, H. & de Jong, N. Microbubble oscillations in capillary tubes. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 60, 105114 (2013).
49. Jang, M. et al. Relation between speckle decorrelation and optical phase conjugation (OPC)-based turbidity suppression through dynamic scattering media: a study on in vivo mouse skin. Biomed. Opt. Express 6, 7285 (2015).
50. Ma, C., Zhou, F., Liu, Y. & Wang, L. V. Single-exposure optical focusing inside scattering media using binarized time-reversed adapted perturbation. Optica 2, 869 (2015).
51. Ferrara, K., Pollard, R. & Borden, M. Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery. Annu. Rev. Biomed. Eng. 9, 415447 (2007).
52. Shapiro, M. G. et al. Biogenic gas nanostructures as ultrasonic molecular reporters. Nat. Nanotechnol. 9, 311316 (2014).
53. El-Sayed, I. H., Huang, X. & El-Sayed, M. A. Selective laser photo-thermal therapy of epithelial carcinoma using anti-EGFR antibody conjugated gold nanoparticles. Cancer Lett. 239, 129135 (2006).
54. Schnarr, K. et al. Gold nanoparticle-loaded neural stem cells for photothermal ablation of cancer. Adv. Healthc. Mater. 2, 976982 (2013).
55. Gradinaru, V., Mogri, M., Thompson, K. R., Henderson, J. M. & Deisseroth, K. Optical deconstruction of parkinsonian neural circuitry. Science 324, 354359 (2009).
56. Judkewitz, B., Horstmeyer, R., Vellekoop, I. M., Papadopoulos, I. N. & Yang, C. Translation correlations in anisotropically scattering media. Nat. Phys. 11, 684689 (2015).
57. Chen, D. & McGough, R. J. A 2D fast near-eld method for calculating near-eld pressures generated by apodized rectangular pistons. J. Acoust. Soc. Am. 124, 15261537 (2008).
58. Raum, K. & OBrien, W. D. Pulse-echo eld distribution measurement technique for high-frequency ultrasound sources. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 44, 810815 (1997).
Acknowledgements
We thank Dr Daifa Wang for developing the idea, Mr Roarke Horstmeyer for the comments on the mathematics and the manuscript, and Mr Joshua Brake as well as Mr Edward Zhou for helpful discussions. We also like to thank Dr Mikhail G. Shapiro,Dr Stephen P. Morgan and Dr Melissa L. Mather for the discussions on microbubbles. This work is supported by the National Institutes of Health (1DP2OD007307-01),the National Institutes of Health BRAIN Initiative (1U01NS090577-01) and the GIST-Caltech Collaborative Research Proposal (CG2012).
Author contributions
H.R. and M.J. contributed equally to the work. H.R. conceived the idea. H.R., M.J. and C.Y. developed the idea and designed the experiments, which were carried out by H.R. and M.J. Data analysis was carried out by H.R. and M.J. with help from C.Y. who also supervised the project. All authors contributed to the preparation of the manuscript.
Additional information
Supplementary Information accompanies this paper at http://www.nature.com/naturecommunications
Web End =http://www.nature.com/ http://www.nature.com/naturecommunications
Web End =naturecommunications
Competing nancial interests: The authors declare no competing nancial interests.
Reprints and permission information is available online at http://npg.nature.com/reprintsandpermissions/
Web End =http://npg.nature.com/ http://npg.nature.com/reprintsandpermissions/
Web End =reprintsandpermissions/
How to cite this article: Ruan, H. et al. Optical focusing inside scattering media with time-reversed ultrasound microbubble encoded light. Nat. Commun. 6:8968 doi: 10.1038/ncomms9968 (2015).
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the articles Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
Web End =http://creativecommons.org/licenses/by/4.0/
8 NATURE COMMUNICATIONS | 6:8968 | DOI: 10.1038/ncomms9968 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Nov 2015
Abstract
Focusing light inside scattering media in a freely addressable fashion is challenging, as the wavefront of the scattered light is highly disordered. Recently developed ultrasound-guided wavefront shaping methods are addressing this challenge, albeit with relatively low modulation efficiency and resolution limitations. In this paper, we present a new technique, time-reversed ultrasound microbubble encoded (TRUME) optical focusing, which can focus light with improved efficiency and sub-ultrasound wavelength resolution. This method ultrasonically destroys microbubbles, and measures the wavefront change to compute and render a suitable time-reversed wavefront solution for focusing. We demonstrate that the TRUME technique can create an optical focus at the site of bubble destruction with a size of ∼2 μm. We further demonstrate a twofold enhancement in addressable focus resolution in a microbubble aggregate target by exploiting the nonlinear pressure-to-destruction response of the microbubbles. The reported technique provides a deep tissue-focusing solution with high efficiency, resolution, and specificity.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer