About the Authors:
Tingting Zhou
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Yun Tao
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Hua Jin
Affiliations Department of Chemistry, Changwon National University, Changwon, 641–773, Republic of Korea, Central Laboratory, Yanbian University Hospital, Yanji, Jilin, 133000, China
Bin Song
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Tao Jing
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Dan Luo
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Yusun Zhou
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Yikai Zhou
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Yong-Ill Lee
Affiliation: Department of Chemistry, Changwon National University, Changwon, 641–773, Republic of Korea
Surong Mei
* E-mail: [email protected]
Affiliation: State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
Introduction
Azithromycin (AZM) (Fig 1) is a macrolide antibiotic (MAC) that is extensively used to treat bacterial infections in human beings, including respiratory, urogenital, pneumococcal pneumonia, and bronchiolitis obliterans [1–3]. However, several side effects will occur when the accumulated dose of AZM exceeds a certain value. Several studies showed that AZM may increase the risk of cardiovascular death and that the interaction between AZM and simvastatin may cause rhabdomyolysis [4,5]. Therefore, the rapid, sensitive, and reliable determination of AZM dosage is of great significance from a health viewpoint.
[Figure omitted. See PDF.]
Fig 1. Chemical structures of six MACs and six other compounds tested in this study.
The six MACs are AZM, ERY, TM, OLE, TYL, and CLA. The six other compounds are DA, STM, GM, TC, NM, and TAP.
https://doi.org/10.1371/journal.pone.0147002.g001
Various methods have been developed for the detection of AZM, including bioassay [6,7], spectrophotometry [8], liquid chromatography [9–12], high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) [13,14] and electrochemical methods [15–18]. However, most of these methods are insufficient either in sensitivity, ease of access, or cost effectiveness. Among the aforementioned methods, the electrochemical protocol is preponderant because of its low cost, ease of preparation, fast response, high sensitivity, and real-time detection.
Sensitivity and selectivity are two common requirements in electrochemical analysis. A variety of carbon materials, including graphene [19,20], carbon nanotubes [21,22], mesoporous carbon [23,24], and metal nanoparticles and oxides [25,26] were extensively used to increase the sensitivity of electrochemical determination. A special type of porous carbon material, namely, acetylene black (AB), has recently attracted considerable attention in the field of electrochemical analysis because of its excellent electric conductivity, high accumulation efficiency and large surface area. These properties of AB are beneficial in improving the sensitivity of electrochemical detection. AB has been used in the sensitive determination of paeonol [27], chrysophanol [28], erythromycin (ERY) [29], and glucose [30]. By contrast, biosensors are used as sensing elements to enhance the selectivity of electrochemical analysis to specific enzymes and antibodies [31,32]. However, the activity and stability of enzymes and antibodies are significantly influenced by temperature, organic solvents, and acidic pH, which restrict their applications. Molecularly imprinted polymers (MIPs), which are considered artificial antibodies, contain recognition sites that are complementary in shape, size and chemical functionality to the target molecules. In sensing ability, the utilization of MIP in modifying sensors enables the development of chemical sensors that are comparable with biosensors in sensitivity [33–36]. MIP also has good chemical and physical stability over a wide range of experimental conditions and solvents. Thus, MIPs are extensively used in selective electrochemical analysis.
In this study, we constructed a novel electrochemical sensor for measuring AZM with MIP/AB composite as selective and sensitive sensing elements. ERY, which is a structural analog of AZM, was selected as the template molecule to prepare MIP. To the best of our knowledge, no electrochemical sensors composite have been developed for the detection of AZM based on the MIP/AB composite. The prepared MIP/AB P sensor exhibited excellent selectivity and sensitivity and satisfactory repeatability and stability in AZM analysis. Finally, the sensor was applied successfully for detection of AZM in tablets and biological samples.
Materials and Methods
Reagents
AZM, ERY, and tilmicosin (TM) were obtained from Sigma-Aldrich (USA). Oleandomycin (OLE), tylson (TYL), and clarithromycin (CLA) were obtained from Dr. Ehrenstorfer (Germany). Dopamine (DA), streptomycin (STM), gentamicin (GM), tetracycline (TC), neomycin (NM), and thiamphenicol (TAP) were purchased from Probe Biotechnology LLC (China). The chemical molecular structures of these substances are shown in Fig 1. AZM-dispersible tablets (250 mg) were obtained from a local pharmacy. Ethylene glycol dimethacrylate (EGDMA), methacrylic acid (MAA) and 2,2-azobisisobutyronitrile (AIBN) were obtained from Sigma-Aldrich (USA). In order to remove the polymerization inhibitor, MAA and EGDMA were purified by distillation in vacuum under nitrogen protection then stored at 4°C before use. AIBN was recrystallized from hot methanol and dried in a vacuum. AB (purity > 99.99%) was obtained from Strem Chemicals (USA). Paraffin oil and graphite powder were obtained from Sinopharm Chemical Reagent Co., Ltd. (China). Acetonitrile and methanol were purchased from KeMiOu Chemical Reagent Co. (China). All other chemicals were of analytical grade and obtained from Sinopharm Chemical Reagent Co., Ltd. (China). All solutions were freshly prepared with ultrapure water.
Instruments
The pore structure and surface area of MIPand NIP were detected by using the ASAP 2010 instrument from RMIT Applied Chemistry (Micromeritics, USA) in the Brunauer–Emmett–Teller (BET) nitrogen adsorption and desorption modes after the appropriate degassing and drying of the sample. The surface morphology of MIP was observed by using a field emission scanning electron microscope (Sirion 200, FEI, Holland). Electrochemical data were obtained from the CHI 660C electrochemistry workstations (Shanghai CH Instruments, China). The prepared MIP- or NIP-involved sensor was used as the working electrode. A saturated calomel electrode (SCE) and a platinum wire were employed as the reference and counter electrodes, respectively.
MIP Synthesis
The MIP synthesis procedure was based on precipitation polymerization according to our previous study [37]. Simplely, the template ERY (1.5 mmol) and functional monomer MAA (6 mmol) were dissolved in 50 mL mixture of methanol/acetonitrile (1/4, v/v) in a 100 mL round-bottomed glass bottle. Thereafter, the mixture was prepolymerized at 40°C for 12 h under stirring. Then, 15 mmol cross-linker (EGDMA) and 40 mg initiator (AIBN) were added after purged with nitrogen for 15 min to remove oxygen, the bottle was sealed and polymerization occurred under magnetic stirring at 60°C for 24 h. The polymer was rinsed with methanol/acetic acid (9/1, v/v) to remove the template until no ERY can be detected by spectrometric measurement (at 210 nm). Finally, the polymer was washed with methanol for several times to remove acetic acid and then dried in oven at 60°C overnight. NIP was prepared similar to the MIP, except that no AZM was added.
Preparation of the Sensors
The chemically modified carbon paste (CP) electrodes were prepared by completely mixing graphite powder (350 mg), AB (100 mg), MIP or NIP (90 mg), and paraffin oil (60 μL) in a mortar for at least 20 min. Subsequently, the obtained paste was packed into the cavity of the working electrode. The surface of the electrode was polished with butter paper to ensure a reproducible working surface. By scraping out the old surface and replacing the paste, the electrode surface was renewed. Only MIP-modified CP (MIP/CP) or only NIP-modified CP (NIP/CP) was prepared similarly, except for the addition of AB. ABP electrode was prepared under the same conditions, except that MIP or NIP was omitted.
Measurement of AZM in Pharmaceutical Tablets and Biological Samples
The prepared MIP/ABP sensor was employed to detect AZM in tablets and in serum and urine samples to verify the performance and feasibility of the developed sensor in real samples.
The AZM tablet (containing 250 mg AZM) was ground to a homogeneous fine powder by using a mortar and pestle. The powder was dissolved in methanol, stirred for 10 min, and filtered. The filtered solution was diluted to a certain concentration by using methanol for further analysis.
Drug-free human serum and urine samples were obtained from healthy volunteers, collected, and stored at −20°C until use. Prior to use, the samples were filtered through a 0.45 μm Millipore filter to be clear. The fresh sample solution was prepared by diluting 100 μL of the sample to 10 mL by using phosphate-buffered saline (PBS; 0.1 M, pH 7.0).Three different concentrations of AZM standard solutions were added to the samples before determination for the spiked recovery experiment. The MIP/ABP electrode was then inserted into the sample solution. The target AZM was extracted and preconcentrated on the surface of the electrode for 8 min under a stirring rate of 500 rpm. Subsequently, the electrode was transferred to the electrochemical cell containing 10 mL PBS (0.1 M, pH 7.0) for differential pulse voltammetry (DPV) determination. The DPV method was conducted with a pulse amplitude of 50 mV, pulse width of 40 ms, and scan rate of 20 mV s−1 over the potential range of 0.4 V to 1.0 V.
Ethics Statement
This study was conducted on the basis of the Declaration of Helsinki and approved by the Institutional Review Board of Tongji Medical College. Before the urine and blood samples were obtained, the volunteers were required to sign a written informed consent after receiving a detailed explanation of the study. The volunteer consents were recorded in a file.
Results and Discussion
Characterization of MIP
In this study, ERY, which is a structural analog of AZM, was selected as a dummy template to prevent the leakage of residual template molecules and prevent the inaccurate determination of the AZM trace level [38]. According to our previous study, the prepared dummy MIP could selectively recognize the target AZM [37].
The static adsorption capacities of MIP and NIP for AZM were determined in various concentrations of AZM ranging from 0.5 g L−1 to 4.0 g L−1. The adsorption capacity (Q, mg g−1) was calculated on the basis of the difference in AZM concentrations before and after adsorption by the polymer by using a constant volume of acetonitrile and a precise weight of MIP or NIP in accordance with the following equation:in which C0 is the initial AZM concentration (mg L−1), C is the AZM concentration after adsorption, V is the volume of acetonitrile (mL), and M is the weight of the polymer (g). As shown in S1 Fig, the adsorption capacities of MIP and NIP increased with the increasing of AZM concentrations. The weak adsorption of AZM on NIP was mainly due to the nonspecific interaction between AZM and NIP.
The porosity of MIP and NIP was investigated by nitrogen adsorption–desorption experiment. According to the test results, the BET surface area was 118.98 m2 g−1 for MIP and 30.45 m2 g−1 for NIP. The pore volume of MIP and NIP was 0.57 and 0.08 cm3 g−1, respectively. The results showed that MIP was more porous than NIP, thus partly explaining why MIP had a higher adsorption capacity than NIP.
The surface morphologies of MIP/ABP electrode, NIP/ABP electrode, ABP electrode, and CP electrode were investigated by scanning electron microscopy. The surfaces of the MIP/ABP electrode (Fig 2C) and NIP/ABP electrode (Fig 2D) were more difference with that of the CP electrode (Fig 2A) and ABP electrode (Fig 2B). As such, we conclude that MIP or NIP was appeared on the surface area of the sensor. MIP (Fig 2E) is also more porous than NIP (Fig 2F), thus partly explaining why MIP has a larger adsorption capacity for AZM than NIP.
[Figure omitted. See PDF.]
Fig 2. The SEM images of various electrodes, MIP and NIP.
CP (A), ABP (B), MIP/ABP (C), NIP/ABP (D) electrodes, MIP (E) and NIP (F).
https://doi.org/10.1371/journal.pone.0147002.g002
Electrochemical Behavior of AZM
In the primary experiments, the electrochemical behavior of AZM on CP, ABP, MIP/CP, NIP/CP, NIP/ABP, and MIP/ABP electrodes were investigated by CV in PBS (0.1 M, pH 7.0). The resulting voltammograms (Fig 3A) showed two anodic oxidation peaks (O1 and O2) at 0.8 and1.0 V.However, no peak was observed in the opposite direction. This finding indicated that the electrochemical reaction of AZM was an irreversible process. Among the different functional groups of AZM, the most easily oxidized group is the dialkylamine group [39]. Dialkylamines oxidize to form a radical cation by the loss of one electron. The peak O1 may be attributed to the form of an aminium cation radical from one of the nitrogen atoms by losing an electron. The peak O2 may be resulted from the oxidation of the product of the aminium cation radical [17].
[Figure omitted. See PDF.]
Fig 3. Cyclic voltammograms (A) and differential pulse voltammograms (B) of AZM on CP, ABP, MIP/CP, NIP/CP, MIP/ABP and NIP/ABP electrode in PBS (0.1 M, pH 7.0).
Conditions: (A) The concentration of AZM is 1 × 10−5 mol L−1, potential scan range: 0.4 V–1.0 V, scan rate: 100 mV s−1; (B) The concentration of AZM is 2 × 10−6 mol L−1, scan rate: 20 mV s−1, pulse amplitude: 50 mV, pulse width: 40 ms.
https://doi.org/10.1371/journal.pone.0147002.g003
The DPV method was employed to investigate the recognition ability of the prepared sensor further. As shown in Fig 3B, the current response of AZM on the MIP/CP and MIP/ABP electrodes was higher than that on the NIP/CP and NIP/ABP electrodes. This indicated that the electrode modified with MIP can intensively absorb AZM from the aqueous solution compared with the electrode modified with NIP because of the selective cavities existing in MIP during the polymerization steps. The DPV signal of the MIP/ABP electrode was also higher than that of the MIP/CP electrode. This indicated that the addition of AB enhanced the sensitivity of the sensor.
Optimization of the Experimental Parameters for the Developed MIP/ABP Sensor
Effect of Electrode Composition on MIP/ABP Electrode Performance.
The amount of MIP, paraffin oil and the ratio of AB/MIP were optimized with one variable at a time to determine the best composition of the MIP/ABP electrode in the fixed conditions of extraction and determination. Fig 4A shows that the maximum response of the prepared sensor was achieved when the amount of MIP was 90 mg. High amounts of MIP in the MIP/ABP electrode can increase the response of the sensor because of more recognition sites on the electrode surface. However, when the amount of MIP was more than 90 mg, a decrease in sensor response was observed because of the decrease in conductivity on the electrode surface. As the sensitive and selective sensing elements for the sensor, the ratio of AB/MIP is important to the performance of the sensor. Fig 4B shows the effect of the ratio of AB/MIP on the sensor performance. The peak current of AZM decreased when the ratio of AB/MIP was lower than 10:9 because the decrease in AB on the electrode surface led to the decrease in sensor conductivity. When the ratio of AB/MIP was higher than 10:9, the peak current of AZM also decreased because the decrease in MIP resulted in the reduction of recognition sites on the surface of the electrode. Therefore, considering sensitivity and selectivity, 10:9 was selected as the best ratio of AB/MIP. The optimum amount of paraffin oil was required for the preparation of the MIP/ABP electrode. As shown in Fig 4C, 60 μL paraffin oil was the best option for preparing the MIP/ABP electrode. In the presence of insufficient amount of paraffin oil, the physical property of the electrode was not able to provide a durable and repeatable electrode surface. However, a high amount of paraffin oil in the electrode led to a decrease in current response because paraffin oil is an insulating material, thus decreasing the conductivity of the electrode surface.
[Figure omitted. See PDF.]
Fig 4. Optimization of different conditions affecting the current response of AZM, including the amount of MIP (A), the ratio of AB/MIP (B), the amount of paraffin oil (C), incubation time (D), and stirring rate (E).
The other conditions are the same as that in Fig 3B.
https://doi.org/10.1371/journal.pone.0147002.g004
Optimization of Extraction Conditions.
The influence of extraction time on the response of the sensor was examined over a time period of 2 min to 12 min. As shown in Fig 4D, the increase of the extraction time led to an intensive increase in the current response up to approximately 8 min. The increase rate of current response was slow down with the increase of extraction time. Thus, 8 min was selected as the optimum extraction time. The effect of stirring rate on AZM extraction was also investigated in the range of 100 to 600 rpm. The results are shown in Fig 4E. The current remained constant at stirring rates higher than 500 rpm. Therefore, the stirring rate of 500 rpm was selected for subsequent use.
The influence of the pH of the sample solution on the oxidation peak current of AZM was investigated over the pH range of 5.0 to 11.0. As shown in Fig 5A, the current response of the MIP/ABP electrode (IMIP) initially increased from pH 5.0 to 9.0 and then decreased from 9.0 to 11.0. Similarly, the current response of the NIP/ABP electrode (INIP) initially increased from pH 6.0 to 10.0 and then decreased from pH 10.0 to 11.0. However, under the same pH condition, IMIP/INIP initially increased with the increase of pH from 5.0 to 6.5 and then decreased with the increase of pH from 6.5 to 11.0. IMIP/INIP refers to the separation factor and reflects the selectivity of the developed sensor. As can be seen in Fig 5A, the variations of IMIP, INIP, and IMIP/INIP are significantly different. In addition to the complementary interaction, the difference was due to the interplay of the hydrophobic effect between target molecules and polymers. The hydrophobic effect is an applied force to transfer nonpolar molecular from water to a nonpolar medium [40]. Therefore, the target AZM, with evident hydrophobic structures was prone to diffuse onto the hydrophobic surfaces of the prepared electrode surface with MIP and recognized by the specific binding sites. When the pH value increased, hydrogen bond between molecules was weakened, in this case, hydrophobic effect will play an significant role in the molecule recognition [41]. Therefore, the specific hydrogen binding between AZM and MIP was weakened with the increasing pH of the sample solution. The weakened interaction consequently led to the decrease in IMIP/INIP. Although IMIP/INIP is largest when the pH was 6.5, the current response of the sensor was much higher when the pH was 7.0. Considering sensitivity and selectivity, pH 7.0 was selected as the appropriate pH of the sample solution for further studies.
[Figure omitted. See PDF.]
Fig 5. Effects of the pH value of the sample solution (A) and electrolyte solution (B) on the current responses of 2 × 10−6 mol L−1 AZM at MIP/ABP electrode.
The other conditions are the same with that in Fig 3B.
https://doi.org/10.1371/journal.pone.0147002.g005
Optimization parameters of Electrochemical Measurement.
The effect of the pH of the electrolyte solution on the peak current of AZM was investigated by varying the pH in the range of 6.0 to 10.0. As shown in Fig 5B, the peak current of the MIP/ABP electrode increased with the increasing pH value from 6.0 to 7.0 and then decreased with a further increase of pH value range from 7.0 to 10.0. IMIP/INIP was changed similarly. Therefore, PBS with pH of 7.0 was selected as the optimum electrolyte solution.
In the case of DPV measurement, the main parameters, pulse amplitude, pulse width, and scan rate, were surveyed over the ranges of 10 to 300 mV, 10 to 100 ms, and 5to 30 mV s−1, respectively. The best sensitivity and a well-shaped wave with a relatively narrow peak width were obtained when 50 mV, 40 ms, and 20 mV s−1 were selected for pulse amplitude, pulse width, and scan rate.
The Selectivity of the Developed Electrochemical Sensor with MIP/AB as Sensing Element
The selectivity of the designed MIP/ABP sensor was evaluated by inserting the prepared MIP/ABP electrode into the solutions of AZM and other MACs, such as TM, OLE, TYL, CLA, and ERY. Fig 6A shows the DPV responses of the MIP/ABP and NIP/ABP electrodes to the tested compounds. The response of the MIP/ABP electrode to AZM was higher than that of other MACs and the response of the MIP/ABP electrode to the six MACs was higher than that of the NIP/ABP electrode. As shown in Fig 1, compared with other MACs, AZM has one more dialkylamine group, thus enhancing the hydrogen-bonding affinity between AZM and the selective recognition sites on MIP. What is more, the dialkylamine group is electrochemically active, thus resulting in a higher peak current of AZM during electrochemical analysis. Therefore, the prepared sensor shows excellent selectivity toward AZM. The response of the prepared sensor to other antibiotics and electrochemically active compounds, such as STM, GM, TC, NM, TAP, and DA, was significantly small. As shown in Fig 6B, the current peak of AZM was much higher than that of other compounds even when the concentration of AZM is 100-fold lower. As shown in Fig 1, the structures of STM, GM, TC, NM, TAP, and DA are significantly different from that of the template. Thus, STM, GM, TC, NM, TAP, and DA can not be easily recognized and adsorbed into the cavities of MIP.
[Figure omitted. See PDF.]
Fig 6. Current responses of 2 × 10−6 mol L−1AZM and other five MACs obtained at the MIP/ABP and NIP/ABP electrodes (A). Current responses of 2 × 10−6 mol L−1 AZM and 2 × 10−4 mol L−1 other six compounds obtained at the MIP/ABP and NIP/ABP electrodes (B).
The other conditions are the same as that in Fig 3B.
https://doi.org/10.1371/journal.pone.0147002.g006
Interference Studies
The effect of several organic and inorganic compounds on the detection of AZM was investigated by adding the interfering compounds in the biological samples to the 2 × 10−6 mol L−1 AZM solution under the optimum measurement conditions. The maximum concentration of a substance when it yielded a relative error of 5% was considered as the tolerance limit. And the mole ratio of the tolerance limit of the interferent and the concentration of AZM is the interferent level. The results shown in Table 1 indicated that the prepared sensor was unaffected by different organic and inorganic substances, even when their concentrations were higher than that of AZM.
[Figure omitted. See PDF.]
Table 1. Interference levels of several tested substances in the determination of 2 × 10−6 mol L−1 AZM by the developed sensor.
https://doi.org/10.1371/journal.pone.0147002.t001
Analytical Characterization
The calibration curve was plotted under the optimal conditions and parameters. As shown in Fig 7A, the response of AZM on the MIP/ABP electrode was enhanced with increasing concentrations from 1.0 × 10−7 mol L−1 to 2.0 × 10−5 mol L−1. As shown in Fig 7B, two linear relationships were presented as I (μA) = 9.68 CAZM (μmol L−1) − 0.43 (r2 = 0.9995) in the range of 1.0 × 10−7 mol L−1 to 2.0 × 10−6 mol L−1 and I (μA) = 2.62 CAZM (μmol L−1) + 13.69 (r2 = 0.9990) in the range of 2.0 × 10−6 mol L−1 to 2.0 × 10−5 mol L−1, where CAZM denotes the AZM concentration. The limit of detection (LOD) of the method was evaluated according to the 3s/b criteria, in which s is the standard deviation of the blank and b is the slope of the linear calibration curve. Finally, the LOD was 1.1 × 10−8 mol L−1.
[Figure omitted. See PDF.]
Fig 7. DPV curves (A) of the MIP/ABP electrode in different concentrations of AZM (from a to i): 0.1, 0.2, 0.5, 1, 2, 5, 10, 15 and 20 μM. Calibration curve (B) of AZM under the optimized conditions.
https://doi.org/10.1371/journal.pone.0147002.g007
The stability and reproducibility of the proposed sensor were also investigated. No significant performance change was observed with a relative standard deviation (RSD) of 3.8% after the electrode underwent three assays every day for one week. Acceptable reproducibility was observed, with the RSD of 4.26% for eight parallel detections. Table 2 shows the comparisons of different types of modified electrodes for the determination of AZM. The developed sensor in this study exhibited superior selectivity because no electrodes in previously published studies were modified by using selective elements. The LOD of our method was the lowest, thus indicating that the developed sensor exhibited superior sensitivity.
[Figure omitted. See PDF.]
Table 2. Comparison of the presented MIP/ABP electrode with other reported electrodes for AZM determination.
https://doi.org/10.1371/journal.pone.0147002.t002
Analytical Application
The developed MIP/ABP sensor was applied to analyze AZM in tablets and biological samples. The HPLC-MS/MS method [14] was applied to detect AZM in real samples to verify the performance of the proposed method statistically. The results are shown in Table 3. A good agreement between the results obtained by our proposed electrochemical method and the HPLC-MS/MS method was observed. These results evidently indicated that the prepared sensor could be reliable and effective for the determination of AZM in real samples.
[Figure omitted. See PDF.]
Table 3. Detection of AZM in real samples by the developed electrochemical method (n = 3) and HPLC-MS/MS method (n = 3).
https://doi.org/10.1371/journal.pone.0147002.t003
Conclusion
In summary, a novel and facile electrochemical sensor was fabricated for the determination of AZM in pharmaceuticals and biological samples. The resulting sensor exhibited outstanding selectivity and sensitivity in AZM detection because of the effective integration of MIP and AB as sensing elements. Compared with previously reported electrochemical sensors, the designed sensor exhibited better selectivity and lower LOD. The proposed sensor was cost effective and exhibited satisfactory applicability. As such, the proposed sensor could be directly applied to the determination of AZM in complex matrices without prior sample preparation or separation.
Supporting Information
[Figure omitted. See PDF.]
S1 Fig. Static adsorption curves of MIP and NIP for AZM.
https://doi.org/10.1371/journal.pone.0147002.s001
(DOCX)
Acknowledgments
This study was supported by the National Basic Research Grant (973) of China (Grant No. 2015CB352100), and the National Natural Science Foundation of China (No. 21577043). We also thank the Analytical and Testing Center of Huazhong University of Science and Technology for SEM analysis.
Author Contributions
Conceived and designed the experiments: TTZ BS SRM. Performed the experiments: TTZ BS TJ. Analyzed the data: TTZ SRM YT DL HJ. Contributed reagents/materials/analysis tools: YSZ YKZ YIL. Wrote the paper: TTZ SRM.
Citation: Zhou T, Tao Y, Jin H, Song B, Jing T, Luo D, et al. (2016) Fabrication of a Selective and Sensitive Sensor Based on Molecularly Imprinted Polymer/Acetylene Black for the Determination of Azithromycin in Pharmaceuticals and Biological Samples. PLoS ONE 11(1): e0147002. https://doi.org/10.1371/journal.pone.0147002
1. Muniz FW, de Oliveira CC, de Sousa Carvalho R, Moreira MM, de Moraes ME, Martins RS. Azithromycin: a new concept in adjuvant treatment of periodontitis. Eur J Pharmacol. 2013;705: 135–139. pmid:23499686
2. Parnham MJ, Haber VE, Giamarellos-Bourboulis EJ, Perletti G, Verleden GM, Vos R. Azithromycin: Mechanisms of action and their relevance for clinical applications. Pharmacol Ther. 2014;143: 225–245. pmid:24631273
3. Nichols DP, Caceres S, Caverly L, Fratelli C, Kim SH, Poch KR, et al. Effects of azithromycin in Pseudomonas aeruginosa burn wound infection. J Surg Res. 2013;183: 767–776. pmid:23478086
4. Ray WA, Murry KT, Hall K, Arbogast PG, Stein CM, Azithromycin and the Risk of cardivasculardisease, New Engl J Med. 2012;366: 1881–1890. pmid:22591294
5. Alreja G, Inayatullah S, Goel S, Braden G. Rhabdomyolysis caused by an unusual interaction between azithromycin and simvastatin. J Cardiovasc Dis Res. 2012;3: 319–322. pmid:23233778
6. Turcinov T, Pepeljinjak S. Azithromycin potency determination: optimal conditions for microbiological diffusion method assay. J PharmaceutBiomed.1998; 17: 903–910.
7. Breier AR, Garcia CV, Oppe TP, Teppe M S, Schapoval EES, Microbiological assay for azithromycin in pharmaceutical formulations. J Pharmaceut Biomed. 2002;29: 957–961.
8. Ashour S, Bayram R. Novel spectrophotometric method for determination of some macrolide antibiotics in pharmaceutical formulations using 1,2-naphthoquinone-4-sulphonate. Spectrochim Acta, Pt. A: Mol Biomol Spectrosc. 2012;99: 74–80.
9. Gandhi R., Kaul C.L., Panchagnula R.. Validated LC method for in-vitro analysis of azithromycin using electrochemical detection. J Pharmaceut Biomed 2000;23: 1073–1079.
10. Miguel L, Barbas C. LC determination of impurities in azithromycin tablets. J Pharmaceut Biomed. 2003;33: 211–217.
11. Bahrami G, Mirzaeei S, Kiani A. High performance liquid chromatographic determination of azithromycin in serum using fluorescence detection and its application in human pharmacokinetic studies. J Chromatogr B Analyt Technol Biomed Life Sci 2005;820: 277–281. pmid:15876560
12. Zubata P, Ceresole R, Rosasco MA, Pizzron MT. A new HPLC method for azithromycin quantitation. J Pharmaceut Biomed. 2002;27: 833–836.
13. Chen L, Qin F, Ma Y, Li F. Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci. 2007;855: 255–261. pmid:17574935
14. Filist M, Buś-Kwaśnik K, Ksycińska H, Rudzki PJ. Simplified LC–MS/MS method enabling the determination of azithromycin in human plasma after a low 100 mg dose administration. J Pharmaceut Biomed. 2014;100: 184–189.
15. Zhang K, Lu L, Wen Y, Xu J, Duan X, Zhang L, et al. Facile synthesis of the necklace-like graphene oxide-multi-walled carbon nanotube nanohybrid and its application in electrochemical sensing of azithromycin. Anal Chim Acta. 2013;787: 50–56. pmid:23830420
16. Peng JY, Hou CT, Liu XX, Li HB, Hu XY. Electrochemical behavior of azithromycin at graphene and ionic liquid composite film modified electrode. Talanta. 2011;86: 227–232. pmid:22063535
17. Mandić Z, Weitner Z, Ilijaš M. Electrochemical oxidation of azithromycin and its derivatives. J Pharmaceut Biomed. 2003;33: 647–654.
18. Ensafi AA, Allafchian AR, Rezaei B. A sensitive and selective voltammetric sensor based on multiwall carbon nanotubes decorated with MgCr2O4 for the determination of azithromycin. Colloids Surf B Biointerfaces. 2013;103: 468–474. pmid:23261568
19. Chen HJ, Zhang ZH, Cai R, Kong XQ, Chen X, Liu YN, et al. Molecularly imprinted electrochemical sensor based on a reduced graphene modified carbon electrode for tetrabromobisphenol A detection.Analyst. 2013;138: 2769–2776. pmid:23476916
20. Yuan B, Xu C, Deng D, Xing Y, Liu L, Pang H, et al. Graphene oxide/nickel oxide modified glassy carbon electrode for supercapacitor and nonenzymatic glucose sensor. Electrochim Acta. 2013; 88: 708–712.
21. Tong Y, Li H, Guan H, Zhao J, Majeed S, Anjum S, et al. Electrochemical cholesterol sensor based on carbon nanotube@molecularly imprinted polymer modified ceramic carbon electrode. Biosens Bioelectron. 2013;47: 553–558. pmid:23644061
22. Xu W, Liu P, Guo C, Dong C, Zhang X, Wang S. Electrochemical sensor based on a carbon nanotube-modified imprinted sol-gel for selective and sensitive determination of ß2-agonists. Microchimica Acta. 2013;180: 1005–1011.
23. Wan K, Long GF, Liu MY, Du L, Liang ZX, Tsiakaras P. Nitrogen-doped ordered mesoporous carbon: synthesis and active sites for electrocatalysis of oxygen reduction reaction, Appl Catal B Envrion. 2015;165: 566–571.
24. Zhang Z, Jiang S, Lai Y, Li J, Song J, Li J, et al. Selenium sulfide@mesoporous carbon aerogel composite for rechargeable lithium batteries with good electrochemical performance. J Power Sources. 2015;284: 95–102.
25. Wu N, Zhao M, Zheng JG, Jiang C, Myers B, Li S, et al. Porous CuO-ZnO nanocomposite for sensing electrode of high-temperature CO solid-state electrochemical sensor. Nanotechnology. 2005;16: 2878–2881.
26. Zhang X, Peng Y, Bai J, Ning B, Sun S, Hong X, et al. A novel electrochemical sensor based on electropolymerized molecularly imprinted polymer and gold nanomaterials amplification for estradiol detection. Sens Actuators B: Chem. 2014;200: 69–75.
27. Zhang H, Gao M, Yang X. Electrochemical oxidation and detection of paeonol on modified electrode with acetylene black nanoparticles. Colloids Surf B Biointerfaces. 2011;87: 378–381. pmid:21684728
28. Zhang Y, Wang Y, Wu K, Zhang S, Zhang Y, Wan C. Electrochemical determination of chrysophanol based on the enhancement effect of acetylene black nanoparticles. Colloids Surf B Biointerfaces. 2013;103: 94–98. pmid:23201724
29. Hu X, Wang P, Yang J, Zhang B, Li J, Luo J, et al. Enhanced electrochemical detection of erythromycin based on acetylene black nanoparticles. Colloids Surf B Biointerfaces. 2010;81: 27–31. pmid:20643533
30. Li M, Qi Y, Ding Y, Zhao Q, Fei J, et al. Electrochemical sensing platform based on the quaternized cellulose nanoparticles/acetylene black/enzymes composite film. Sens Actuators B: Chem. 2012;168: 329–335.
31. Mazloum-Ardakani M, Ahmadi R, Heidari MM, Sheikh-Mohseni MA. Electrochemical detection of the MT-ND6 gene and its enzymatic digestion: application in human genomic sample.Anal Biochem. 2014;455: 60–64. pmid:24650582
32. Rafique S, Bin W, Bhatti AS. Electrochemical immunosensor for prostate-specific antigens using a label-free second antibody based on silica nanoparticles and polymer brush.Bioelectrochemistry 2015;101: 75–83. pmid:25156671
33. Alizadeh T, Ganjali MR, Nourozi P, Zare M, Hoseini M. A carbon paste electrode impregnated with Cd2+ imprinted polymer as a new and high selective electrochemical sensor for determination of ultra-trace Cd2+ in water samples. J Electroanal Chem. 2011;657: 98–106.
34. Arvand M, Fallahi P. Voltammetric determination of rivastigmine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode. Sens Actuators B: Chem. 2013;188: 797–805.
35. Gholivand MB, Torkashvand M. A novel high selective and sensitive metronidazole voltammetric sensor based on a molecularly imprinted polymer-carbon paste electrode. Talanta. 2011;84: 905–912. pmid:21482301
36. Liu B, Wang XL, Lian HT, Sun XY. Xanthine microsensor based on polypyrrole molecularly imprinted film modified carbon fiber microelectrodes. Anal Biochem 2013;440: 220–226. pmid:23747534
37. Song B, Zhou Y, Jin H, Jing T, Zhou T, Hao Q, et al. Selective and sensitive determination of erythromycin in honey and dairy products by molecularly imprinted polymers based electrochemical sensor. Microchem J. 2014;116: 183–190.
38. Yin YM, Chen YP, Wang XF, Liu Y, Liu HL, Xie MX. Dummy molecularly imprinted polymers on silica particles for selective solid-phase extraction of tetrabromobisphenol A from water samples. J Chromatogr A. 2012;1220: 7–13. pmid:22197256
39. Nigović B, Šimunić B Voltammetric assay of azithromycin in pharmaceutical dosage forms. J Pharmaceut Biomed. 2003;32: 197–202.
40. Wang XJ, Xu ZL, Feng JL, Bing NC, Yang ZG. Molecularly imprinted membranes for the recognition of lovastatin acid in aqueous medium by a template analogue imprinting strategy. J Membr Sci. 2008;313: 97–105.
41. Lin FY, Chen CS, Chen WY, Yamamoto S. Microcalorimetric studies of the interaction mechanisms between proteins and Q-Sepharose at pH near the isoelectric point (pI) Effects of NaCl concentration, pH value, and temperature, J Chromatgr A. 2001;912: 281–289.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2016 Zhou et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
A new selective and sensitive sensor based on molecularly imprinted polymer/acetylene black (MIP/AB) was developed for the determination of azithromycin (AZM) in pharmaceuticals and biological samples. The MIP of AZM was synthesized by precipitation polymerization. MIP and AB were then respectively introduced as selective and sensitive elements for the preparation of MIP/AB-modified carbon paste (MIP/ABP) electrode. The performance of the obtained sensor was estimated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. Compared with non-molecularly imprinted polymer (NIP) electrodes, NIP/ABP electrodes, and MIP-modified carbon paste electrodes, MIP/ABP electrode exhibited excellent current response toward AZM. The prepared sensor also exhibited good selectivity for AZM in comparison with structurally similar compounds. The effect of electrode composition, extraction parameters, and electrolyte conditions on the current response of the sensor was investigated. Under the optimized conditions, the prepared sensor showed two dynamic linear ranges of 1.0 × 10−7 mol L−1 to 2.0 × 10−6 mol L−1 and 2.0 × 10−6 mol L−1 to 2.0 × 10−5 mol L−1, with a limit of detection of 1.1 × 10−8 mol L−1. These predominant properties ensured that the sensor exhibits excellent reliability for detecting AZM in pharmaceuticals and biological fluids without the assistance of any separation techniques. The results were validated by the high-performance liquid chromatography–tandem mass spectrometry method.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer