ARTICLE
Received 23 Dec 2015 | Accepted 21 Jul 2016 | Published 11 Oct 2016
Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic eld gradient. Signals corresponding to specic regions of the molecules nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy.
DOI: 10.1038/ncomms12667 OPEN
A quantum spin-probe molecular microscope
V.S. Perunicic1, C.D. Hill1, L.T. Hall2 & L.C.L. Hollenberg1,2
1 Centre for Quantum Computation and Communication Technology, School of Physics, University of Melbourne, Melbourne, Victoria 3010, Australia. 2 School of Physics, University of Melbourne, Melbourne, Victoria 3010, Australia. Correspondence and requests for materials should be addressed to V.S.P. (email: mailto:[email protected]
Web End [email protected] ) or to L.C.L.H. (email: mailto:[email protected]
Web End [email protected] ).
NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 1
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667
In conventional techniques used to determine biomolecular structure such as X-ray crystallography, nuclear magnetic resonance (NMR) spectroscopy or free electron laser femto-
second serial crystallography, large numbers of the target molecule are required to obtain sufcient signal. To obtain structural information at the single-molecule level, as close to in situ as possible, one requires a true molecular microscope. In this quest, the tantalising prospect of using quantum spin probes for the detection of nuclear spins in molecules has been a key driver of much of the research in quantum sensing using the nitrogen-vacancy (NV) centre in diamond1,2, with recent experimental demonstrations of internal and external nuclear spin detection under ambient conditions313. These breakthroughs have spurred a number of theoretical proposals for molecular level NMR, including methods for molecular detection based on intrinsic nuclear ipping rates14, Rabi driving induced resonant detection15, 1-D NMR spectroscopy16 and amplied long-range sensing of nuclear spins17. Of particular note are proposals heading towards molecular structure determination based on 2-D NMR-related spectroscopy1820, and magnetic tip induced eld gradient imaging21. Recently, a technique to use a NV-centre probe together with a Hamiltonian interrogation protocol has been proposed for nuclear localisation of individual spin labels based on the determination of their full hyperne tensor in the weak eld regime22. However, it is not clear whether these techniques can achieve structure determination with angstrom-level resolution for real-world size biomolecules required for biological applications. Highly stable external gradient elds, that are signicantly stronger than presentably achievable, are required to sufciency surpass the B70 G nm 1 threshold where gradient splitting becomes equal to the typical nuclear dipoledipole coupling. While 2D NMR techniques may suffer from the same limitations of their ensemble counterparts in terms of the maximum molecule size for which the complex frequency spectra inversion can be carried out2327.
In this paper, we present a method based on a quantum spin probe which acts as a self contained three-dimensional (3D) nanoscale magnetic resonance imaging system enabling microscopy and structure determination at the single molecule level. Rather than rely on large external eld gradients for spatio-frequency encoding, which require precise characterisation, we instead use the natural spin-dipole eld of the probe spin to provide highly stable spatial encoding of target nuclear frequencies. The protocol interleaves three carefully constructed levels of quantum control: decoupling of nuclear spins in the target molecule, frequency selective driving of target spins in dipole slices formed by the probes natural gradient eld, and signal accumulation on the probe spin from which nuclear spin density and 3D molecular structure can be determined. To be useful, any single-molecule sensing system must be able to match or exceed the resolution and precision of established ensemble techniques, the state of the art of which are currently at the angstrom level23
31. Using the 1kDa rapamycin molecule (National Center for Biotechnology Information, PubChem Compound Database, CID 5284616) as a non-trivial test case, we simulate the
nano-MRI protocolnuclear spin decoupling, frequency space selective addressing, data acquisition and analysis, spin-density image formation and molecular reconstruction. We obtain 3D images of the hydrogen nuclear spin density (an important distinction to conventional X-ray crystallography where it is difcult to obtain signal from 1H nuclei) and with isotopic labelling we show it is possible to image 13C atomic sites. Under currently accessible experimental conditions the average image resolution achieved is at the angstrom level, with the associated reconstruction error at the sub-angstrom level. Further optimization could incorporate higher order detection
sequences, adaptive sampling techniques, and/or pre-exploration using fast coarse grained information about a molecules structure. Specic information about molecular conformation or similar mapping applications could be obtained relatively quickly using distinct nuclear spin labels32. Importantly, the quantum probe MRI technique does not require complex sample preparation, and is ideally suited to the challenging in situ membrane protein problem. The NV system is an obvious candidate for implementation, particularly for fast coarse structure determination and/or labelled conformation dynamics under ambient conditions. However, it is inevitable that molecular motion will compromise resolution for precise structure determinationfor these applications the target molecule will need to be immobilized as far as possible, for example by operating at low temperatures, and snap freezing the target with its associated hydrated environment3335. Such a prospect also opens up the possibility of exploiting the extremely long coherence times of phosphorus donors in silicon (Si:P)36,37, and associated single-atom fabrication techniques38, for high-precision molecular imaging.
ResultsSystem overview. The set-up is shown in Fig. 1a and consists of a single controllable electronic spin defect in a semiconductor lattice, located 24 nm below the substrate surface, above which the target molecule is located. For high-resolution imaging we assume the vibrational and rotational degrees of freedom in the molecule are suppressed, by keeping the system and its hydrated environment in a typical temperature range of 77 K and below34. Positioning the molecule above the spin probe can be achieved in several ways. Mechanical placement of the molecule onto a silicon surface can be performed using an STM/AFM tip, or with optional initialisation of covalent bonding via STM current39. Alternatively, a number of molecules can be placed on the surface statistically ensuring probe to target proximity40. The spatial localization of the probe spin allows it to be in close proximity to the molecule and the dipole interaction eld between the molecular nuclear spins and the electronic probe spin assumes the role equivalent to the classical gradient eld in conventional MRI (Fig. 1a). The direction of the background magnetic eld B0 (with magnitude of order 1-2 T), denes the quantization axis of both the probe spin and the nuclear spins of the molecule, thus providing a way of controlling the effective strength and direction of the dipole interaction between the probe and nuclei spins. The nuclear spins in the molecule are subjected to two different regimes of controla high amplitude constant radio frequency eld used for nuclear decoupling, and a considerably weaker NMR eld for resonant excitation. We primarily focus on imaging the 1H nuclear density as the most abundant species in organic molecules, however, as we will show the method is also applicable to other spin species (for example, 13C or 14,15N) through isotope enrichment. As a MRI based method, our protocol encodes structural spatial information onto frequency space, however, in contrast to conventional MRI, where the magnetic eld gradient forms equipotential planar slices, the nuclei experiencing equal interaction with the probe spin are located on curved, non-uniform slices, corresponding to dipole lobes (Fig. 1a). The exact shape of the interaction slices depends on the probes electronic wave function, which for simplicity we assume is highly localized (for example, NV), but in principle can be pre-characterized (for example, Si:P)41 and/or calibrated using known structures. Details of the actual probe electronic wave function would modify the coupling prole, however, the overall imaging methodology itself is independent of any particular shape of the interaction slices.
2 NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667 ARTICLE
a b
( B0, B0)
B0
Signal
S
Interaction broadening
(krad s1) nB0
d
s
Signal
d
s
d
Probe spin control
Nuclear spin decoupling
s
(krad s1)
s
s
s
c d
Transform
3D image
Molecular nuclei
Probespin t /2 t /2
/2
Control rotation
/2
Nuclear density per dipole slice
13C
H
Figure 1 | Overview of single-molecule MRI using a quantum spin probe. (a) The set-up consists of a controllable electronic probe situated 24 nm below the surface of the substrate, above which a molecule is positioned. The probe acts as both sensor and gradient eld source for the spatial-frequency encoding of the nuclear spins in the target molecule. The equipotential slices (frequency, oS) of the probes coupling eld gradient have a characteristic dipoledipole lobe shape, and can be spatially rotated by varying the direction (yB , fB ) of the background magnetic eld B0 (magnitude of order 1-2 T). (b) Initially, the
NMR spectrum of the molecule is broadened by the numerous nuclear dipoledipole interactions (blue lines). The protocol decouples nuclei from each other in the presence of the coupling gradient eld of the probe, and resonant excitation of target spins at oS provides a spatial MRI signal encoded on the probe state. In the spectrum obtained by sweeping the excitation frequency, the peak amplitudes characterize the spin density over the corresponding probe coupling slice. (c) High-level schematic of the interleaved control protocol structure consisting of a spin-echo sequence on the probe spin, and the slice-selective controlled nuclear spin rotation (excitation) embedded into a nuclear decoupling sequence. (d)The target molecules nuclear density is sampled for multiple orientations of the interaction slices, followed by transformation from dipolar-slice space to cartesian space, to produce a 3D nuclear spin density image of 1H atoms, or other non-zero nuclear spin species such as 13C. Atomic positions are directly extracted from the density image data.
The NMR spectrum of a stationary molecule is dominated by its intrinsic dipoledipole iterations (Fig. 1b, top), causing each nucleus to be detuned from the resonant frequency dened by the probe interaction slices. The average extent of such detuning for
1H nuclear spins is comparable to their coupling to the probe spin, leading to a full loss of correlation in mapping from real to frequency space. To overcome this obstacle, the control protocol simultaneously suppresses the coupling between the nuclei themselves, and extracts the information about the number of nuclei present in each of the interacting slices (Fig. 1b, lower). In the rst instance, we consider well-established pulse sequences in the solid state NMR and quantum sensing literature as foundations for the control protocol. At a high level, the protocol (shown in Fig. 1c) is composed of a spin-echo sequence (t/2 p t/2) of length t performed on the probe and a
decoupling sequence applied on the nuclear spins. In the rst time period (0-t/2), controlled rotations of the nuclear spins located at a chosen resonant interaction slice are performed based on the probe spin state. These operations induce a phase in the probe spin state which accumulates information about the nuclear number density present on the probed interaction slice. In the second time period (t/2-t) the nuclear spins are subjected to a decoupling sequence only, inducing no additional phase in the probe spin state. This particular form, where only one half of the probes spin-echo sequence receives the information, is chosen in particular for its high quality signal output of a simple sinusoidal form. In principle, multi pulse dynamical decoupling sequences (for example, CPMG, XY8, UDD (ref. 42)) can be used on the probe, containing multiple appropriately implemented control rotation segments. However, a balance is required;
as the rate of information transfer from molecular nuclear spins to the probe is set by the coupling strength between the two, high order sequences can have a negative effect on sensitivity as they serve to decouple the probe from the nuclear spins.
Interleaved quantum control and measurement protocol. The multi-tier control sequence is shown in more detail in Fig. 2. The notation for probe-target operations used in writing out the entire sequence is dened in Fig. 2a and b. The R pulses (Fig. 2a) are resonant to a particular slice and transfer target spin information to the probe. The strong 90 non-selective decoupling radio frequency pulses, D p2
x;y, of eld strength BD (Fig. 2b),
suppress the coupling between the nuclei. For deniteness, in this initial proposal we employ the CORY24 decoupling sequence used in conventional NMR (ref. 43), as shown in Fig. 2c (Methods section, homo-nuclear decoupling). A single segment of the overall sequence, interleaving probe-controlled rotations, R, and nuclear decoupling pulses, D, is shown in Fig. 2d. The set of pulses {Ri(oi,Fi,ti,BR)ni}, (Fig. 2a) are applied during the free precession time ti 2 {t, 2t} around a carefully designed set of axes,
{ni}, which are determined by the driving eld amplitude BR, frequencies {oi}, and phases {Fi} (shown in Fig. 2e and f; the construction is described in more detail below). Each Ri pulse induces a perturbation in the states of a selected nuclear population, in a given dipole slice, of magnitude proportional to gnBRti, where gn is the target nuclear gyromagnetic parameter. Critically, the consecutive R pulses are synchronised to produce a cumulative signal, corresponding to the number of nuclear spins targeted, on the probe spin. This is achieved by setting the parameters oi and Fi in accordance with both the previous Ri 1
NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 3
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667
a
b
Nuclear spin
Probe spin
Ri
D [+ /2]x D [+ /2]y
D [ /2]y
D [ /2]x
| + | 2
[ i, i, i, ni]
^
c
d
e
f
2 2 2 2
2 2
2 2
2 2
2
R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24
i[rad s1]
500
500 0
7 8 9 10
11 12 13 14 15 16 17 18 19 20 21 22 23 24
[afii9818]i
4
7 8 9 10 11 12 13 14 15 16
g
Ri
h
z
n1
n7
z
n2
n3
n4
n5
n6
n8
n9
ni
9
2 10 1
y
n10
n11
n12
y
Di :
ni
ni+1
38
7
11
x
4
x
Ri+1
Di
5
6
ni+1
i j
0.4
0
0.4
S
Nuclear spins
Signal ()
0.2
0.0
0.20.0
0.2
0.4
0 2 4 6 8
t /2
N 24
=
0.2 = 0
(k rad s )
Probe spin
1 2 3 5
4
0 0 1 2 3 5
6
6
0.4
t
17 18 19 20 21 22 23 24
i
i
/2
0
20
40
60
80
100
120
t (ms)
Figure 2 | Detailed outline of the proposed control protocol. (a) The ith control rotation pulse, Ri, of length t, selectively rotates the population state of the nuclear spins located at a particular coupling slice of resonant frequency oS. (b) The non-selective, spectrally broad, 90 pulses D p2
x; y used for the
nuclear decoupling. (c) The nuclear decoupling sequence (based on CORY24) has no effect on the probe spin as the nuclear pulse frequency is well away from the electronic resonant condition. (d) The control rotation pulses Ri are embedded into the decoupling sequence in place of the free precession times.
Their phase and frequency is specically tailored to produce a cumulative resonant nuclear spin state rotation in the selected interaction slice. (e) Example of the frequency detuning control of the polar tilt of Ri rotation axis (initial 24 pulses for a nuclear spin in GS 8 103 rad s 1 interaction slice).
(f) Associated phase of the driving eld required for the Ri pulses in e. (g) The phase and frequency of Ri pulses synchronised through tracking the plane of rotation (direction of the driving eld) as it is transformed by successive D pulse. (h) Example of several consecutive planes of rotation dened by their normals ^
ni. Each interaction slice has a unique pattern of driving eld parameters (phase and frequency) as the decoupling pulses are timed according to the background magnetic eld from which the interaction slices are frequency shifted by the coupling to the probe spin. (i) High-level schematic of the total control protocol. The phase induced in the evolution of the probe spin by the selective control rotation of the nuclear spins is a function of the number of nuclear spins in the probed interaction slice. The p pulse on the probe serves to refocus both the probe phase, and the effects of probes gradient coupling on the nuclear spins. (j) The temporal evolution of the sequence on/away from resonance (blue/red). The signal is obtained by choosing an observation time t and sweeping the frequency oS.
pulse and decoupling pulses, D. The overall nuclear dynamics are characterized by the slow modulation envelope due to R pulses on top of the fast dynamics of the decoupling sequence. Under a relatively long spin-echo sequence (tB1/gnBRct), the probe is only sensitive to the slow dynamics associated with the nuclear spins located at the selected interaction slice forming a nal signal corresponding to the number of target spins in that slice.
We now analyse the resonant slice conditions in more detail. Consider a nuclear spin at a given coordinate r (in the lab frame)
relative to a well-localized electronic spin 12 probe, under a magnetic eld B0 B0(sinyB0 cosfB0, sinyB0 sinfB0, cosyB0) of
constant magnitude B0 and variable orientation (yB0,fB0). The nuclear spin resides in the interaction slice of equi-coupling strength GS(yB0, fB0;r) as dened by the secular dipoledipole coupling eld:
GSyB0; fB0; r gegn
m0 4p
; 1
1 1 3
^
B0 ^r2
4 NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667 ARTICLE
by the following form:
Sao; yB0; fB0; t; BR; ra
1
2 cos
18 gnBRt
where the ^
B0 ^r term denes the orientation of dipole interaction
slices as function of background magnetic eld direction (yB0,fB0). The decoupling pulses D are timed with respect to the background magnetic eld frequency gnB0, however, the nuclear spins precess with frequencies according to the dipole slice resonant coupling, that is, oS() gnB0GS/2 (for clarity we
suppress angular dependencies when not required), where oS()
represents the resonant nuclear frequencies associated with each of the probes two spin states. Therefore, as observed in the frame of an interaction slice (dened by GS), the axis of the decoupling pulses rotates with relative frequency GS/2. The plane dened by a normal ^
ni in which Ri induces a rotation thus transforms into a new plane ^
ni 1 under the inuence of a decoupling pulse, Di. To
achieve a cumulative phase signal on the probe, the Ri 1
performs a control rotation in the transformed plane ^
ni 1 to add
to the previous rotation of the nuclear spin state (Fig. 2g). The initial pulse, R0, constitutes a controlled rotation in the direction ^
n0, which can be an equatorial direction of choice. At the end of the CORY24 sequence the net cumulative control rotation of the selected nuclear spins is returned back to this initial direction, leading to a net change in the z-projection of the nuclear spin states which is detected by the probe. Unless explicitly stated otherwise, from here on we assume the interrogation of the spectrum is performed in the positive frequency side o S oS,
omitting the superscript (as illustrated in Fig. 1b). Relative to the initial axis ^
n0 any subsequent control rotation Ri is formulated by transformation of ^
n0 under the decoupling D pulses as observed in the frame of the particular interaction slice characterized by coupling strength GS:
^
ni Y
i
j1
0
@
1
Ae t=T2n;
4
gnBR
@
gnBR2 Da 2
0 q
q
gnBR
gnBR2 D a 2
1
D a o Sa o gnB0 GSyB0; fB0; ra=2 o; 5
where ra is the coordinate of the of the ath nuclear spin, (yB0,fB0) is the direction of the background magnetic eld, T2n is the
effective transverse coherence time of nuclear spins, and D a is detuning of the scanning frequency o from the resonance frequencies, o Sa. The typical temporal dependence of the signal (Fig. 2j) has a sinusoidal shape, analogous to Rabi oscillations, reecting the cumulative effect induced by ne driving R pulses on the nuclear spin state. In addition to providing a high quality signal, the presence of selective, slow nuclear evolution in only one half of the probe spin-echo sequence results in a characteristic detuning behaviour. As D a increases, the frequency of the signal decreases, while the maximum amplitude remains unchanged, as illustrated by Fig. 2j. This is particularly useful for the generation of a clean signal trace as a function of sweep frequency, o, at a xed time t, providing an effective
Lorentzian signal peak. For well decoupled nuclear spins (T2n4t)
in an equally mixed spin state, the total signal from a slice resonantly addressed by frequency o can be expressed as a product of signals originating from each individual nucleus:
So; yB0; fB0; t; BR Y
NS
a1
eiGStDj =2Dje iGStDj
=2^
Sao; yB0; fB0; t; BR; rae t=T2p;
n0: 2
where Dj is the jth decoupling pulse occurring at time tDj. Once the unique sequence of driving directions is determined for a given target interaction slice (Fig. 2h), it follows that the pulse Ri resonant with the interaction slice of coupling strength GS, is constructed by applying the magnetic eld of frequency oi and initial phase Fi as dened by ^
ni ^
nix; ^
niy; ^
niz:
BR^
niz
^
3
The frequency shift doi denes the polar tilt of the rotation axis while the phase Fi denes the azimuthal direction. The frequency and phase control are depicted in Fig. 2e,f. We note that from the perspective of practical implementation, the phase of the driving eld of each pulse Ri is more crucial than the frequency shift doi. In the case of high background magnetic elds (B0B1T) and relatively low driving elds (BRB1 mT) the frequency shifts are relatively small. Furthermore, the average doi is equal to zero. Thus, keeping the driving frequency constant (unlike the phase) oi-oS across all R pulses produces the resonant behaviour comparable, to within several percent, to the full variable frequency control. The fully integrated control protocol is depicted in Fig. 2i.
When the power broadening due to the ne driving eld BR is
smaller than the probe coupling GS, and the probe spin is held in an equal superposition state, the signal Sa (Fig. 2j) generated by the ath nuclear spin under the sequence is well approximated
6
where NS is the total number of spins in the slice of the species, and T2p is the transverse coherence time of the probe spin. We emphasise that the outlined methodology can be generalized with respect to variations in the nuclear decoupling and probe detection sequences. In the case of decoupling sequences that have less or no free procession periods, the control rotation, R, pulses can be applied simultaneously with any decoupling pulse, provided the two commute. An additional feature of the control sequence is the positive effect on the probes coherence time T2p.
By suppressing the dipole coupling between the nuclei, the protocol simultaneously modies the intrinsic magnetic uctuation spectra of the molecule, and thus its frequency spread is reduced to a narrow band around a single high frequency (1/t)
that is outside the detection range of the probe sensing protocol. This property opens up a noise-free window in low-frequency spectrum, which is particularly suitable for high-resolution detection of remote nuclear spins.
To illustrate the behaviour of the integrated detection protocol (Fig. 2i), we perform a fully quantum simulation of a cluster of 1H nuclei at realistic distances from the probe which couple through their mutual dipoledipole interactions (Fig. 3a). In the spectrum obtained by sweeping the frequency, o, the peak heights contain information on the number of nuclei located in the same interaction slice (Fig. 3b, front plane). Figure 3b depicts the spatio-frequency encoding behaviour of the MRI spectrum as a function of the detection protocols decoupling parameters. The upper pane (Fig. 3b) corresponds to the strong decoupling regime. Moving down towards the lower pane corresponds to weaker decoupling where the spatial encoding of the MRI spectrum is distorted due to emerging dipoledipole interactions between the nuclei, reected in progressive splitting of initial MRI peaks. The results indicate that decoupling elds BD with
oi
oS doi gnB0 GS=2 doi;
doi
;
q
n2ix ^
n2iy
Fi arctan^
niy=^
nix oStDi:
NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 5
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667
b
BD = 40 mT = 1.5 s
BD = 20 mT = 3.0 s
S1
S2
S3
Normalized probe signal, S
Normalized probe signal, S
a
BD
BR
BD = 13 mT = 4.4 s
BD = 10 mT = 6.0 s
BD = 5.0 mT = 12 s
BR = 0.25 T t = 100 ms
BR = 0.50 T t = 50 ms
BR = 0.5 T t = 33 ms
BR = 1.0 T t = 25 ms
BR = 2.0 T t = 12.5 ms
4
d-d
2
4 5 6 7 8 9 10 11 12
4 5 6 7 8 9 10 11 12
(k rad s1)
2
c
4 nm
(k rad s1)
Figure 3 | Quantum simulation of the target nuclear spin decoupling sequence. (a) Four 1H nuclei (grey), positioned 2 apart, located 4 nm above the probe electronic spin (orange). The spatial interaction slices are shown, with labelled resonant frequencies oS1-3. (b) The MRI spectra (for each plot the probe signal is normalized to unity (0-1), where S 0 represents the mixed state and S 1 is the maximum z-projection of the probe spin state) as a
function of decoupling eld strength BD, for an order of magnitude ratio between the decoupling pulse (D[p/2]) length and time between the pulses t,
t= 12
p g B
10. The peaks at frequencies {oS ,oS ,oS } in the upper plot (decoupled spins) correspond to the nuclear density in the associated interaction
slice. The panes moving downward show the loss of spatial-frequency coding as the decoupling efciency decreases. (c) The MRI spectra (same normalization convention as in b) under different driving strength elds BR exhibits typical power broadening behaviour, depicted, for visual clarity, in the spin decoupled regime BD 40 mTwith sampling times t adjusted to preserve the signal normalization (gnBRt constant). The simulations were performed
at B0 2 T and T2p 50 ms.
amplitudes of order 2040 mT are required. This estimate is appropriate in the case of more complex nuclear systems, as the local environment of nuclear spins dominates the coupling magnitudes. Figure 3c depicts the degree of power broadening behaviour of the detection sequence as the ne driving eld strength BR increases, indicating minimum quantum probe coherence times T2p requirements in the range of 3050 ms for sufcient resolution of molecular features at the angstrom level. This is well within reach of coherence times for P donors in puried silicon at a typical operational temperature of order 100 mK (refs 36,37). The coherence times of the NV centre in diamond are at present insufcient for full-structure determination, although the required regime may, in principle, be reached by further diamond surface engineering and isotropic purication related to nitrogen and carbon(13) baths44,45. Current experimental coherence times for near-surface NV centres may allow conformation detection based on imaging the locations of a small set of spin-labels.
MRI measurement and structure determination. We now illustrate the entire protocol using a non-trivial examplethe rapamycin molecule (C51H79NO13). This particular molecule, in the mass range B1 kDa, is around three orders of magnitude larger than that considered in proposals for 1D and 2D NMR spectroscopic approaches18,19,22. In our approach, once a sufcient level of decoupling is assumed, it is possible to simulate the entire structure determination protocol. We apply the sequence to acquire 1H and 13C nuclear density data and
obtain the molecular coordinates for the two atomic species. The spectral data was sampled at multiple orientations of the background magnetic eld as depicted in Fig. 4a (Methods section, 3D imaging protocol), and contains the nuclear density of the target molecule in dipolar-slice spacenumerical inversion into cartesian space (Fig. 4b,c) yields the molecular nuclear 3D densities shown in Fig. 5b,c. The 1H and 13C atomic positions in the rapamycin molecule are readily observable by inspection of contours of 50 and 75% contrast around 3D density peaks having distinct spherical shapes. The atomic coordinates are reconstructed by thresholding local maxima in the nuclear densities above 90% (crosses, Fig. 5b,c), and estimating the uncertainty in the atomic positions by average of the full width at half maximum (FWHM) in three axial cross-sections of the 3D density peaks. Figure 5d shows the atomic site coordinates with the colour scale conveying the spatial uncertainties (corresponding to the widths of the density peaks) in atomic positions ranging from 0.4 to 1.4 . We note that these coordinates are derived directly from the density image, without potential energy minimization or other post-processing. Comparison of the reconstructed atomic coordinates to the true molecular coordinates, gives an average statistical variation of0.5 , represented as the radius of the spheres in Fig. 5d. Using this simple data collection strategy, the total acquisition time amounts to B175 h under realistic experimental conditions to image the 1H structure of rapamycin (and twice as long for the
13C structure). These calculations assumed probe and nuclear target coherence parameters T2p 50 ms, T2n 50 ms and a
detection sequence of total length t 8 ms, with shot noise limit
6 NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667 ARTICLE
a
q q
p p
n n
[afii9845]
k,i,j pk,,q i,j,n
S ( S , B i , B j)
0 B0u B0v
c
=
1,1,1
p,q,n
M
[afii9845] = M1 S
Figure 4 | Protocol for nuclear 3D density imaging: (a) Illustration of interaction slices Gk,i,j resonantly addressed by oSi at various orientations (yB i,fB j) showing the characteristic dipoledipole shape of the coupling equipotential (GS(yB i,fB j; r) oS). (b) An example of data decomposition for a single slice
where the volume containing the target molecule is discretized (p q n) allowing for voxelated representation of both the nuclear density and each
interaction slice. (c) The vectorized form of the voxelated nuclear density q, the voxelated interaction slices Gk;i;jp;q;n and the vectorized form of the measured signals S taken for all orientation and fervency values, enable construction of a map M from the nuclear density r in cartesian space to the measured signal S in slice-space. Each row of the map M corresponds to a vector form of a single voxelated interaction slice Gk;i;jp;q;n. This representation allows for inversion of the map M leading to extraction of the 3D nuclear density q M 1S.
10
a b
50
1H density
50% Contour 75% Contour Maxima
1H sites (blue)
13C sites (red)
45
z()
40
35
10
0
10 10
1.2
y ()
5
0
5
x ()
c
d
50
45
40
35
10
0
1010 5 0 5 10
0.8
0.6
0.4
1.2
1.4
13C density
50% Contour75% ContourMaxima 1.0
1 H peak density
FWHM ()
z()
13 C peak density
FWHM ()
1.0
0.8
0.6
0.4
y ()
x ()
Figure 5 | Simulation of the nano-MRI protocol carried out on a single rapamycin molecule (C51H79NO13). (a) Hydrogen and carbon substructure of the rapamycin molecule. Sampling was performed over 150 slices for each of 11 24 latitude and longitude orientations of B0 with MS 2000 measurements
per slice and sequence length t 8 ms. (b,c) Extracted 1H and 13C nuclear densities, respectively. The 3D density is represented through 50% and 75%
contours that reveal subthreshold features. Atomic positions are identied corresponding to local maxima in the 3D density that are 490% or greater in relative terms (shown as crosses in (c,d)). The uncertainty in position (effective resolution) is estimated from the average of the (x,y,z) FWHM cross-sections of the 3D density peaks. Peaks closer to the probe (smaller z values) are narrower due to stronger gradient coupling to the probe, while isolated peaks are further localized due to a greater relative contrast in the numerical inversion procedure. (d) Reconstruction of the atomic positions and associated resolution (colour scales) are shown for 1H (blue colour scale) and 13C (red colour scale). The sphere size corresponds to the average statistical deviation in comparison to the exact coordinates of Dr 0.5 (superimposed on the data is the exact skeletal structure from a.
NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 7
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667
given by MS 2000 single shot measurements per slice over 150
slices for each of the 264 B0 orientations (for details see Methods section, parameters for the molecule example). With the outlined parameters, the protocol provides a hemispherical imaging volume of B8 nm in radial extent above the probesufcient for imaging proteins across cell membranes (B4 nm thickness). Where larger imaging volumes are required, it may be possible to augment the protocol with additional external (classical) gradient elds21, however, with increasing probe-target distance detection is more limited. The variation in 3D density resolution along the z axis is consistent with the simple constant sampling methodology used in this example, where the frequency sweep steps are constant yet the dipole strength gradient is not. Thus, the results from this rudimentary sampling procedure should serve as an indicator of the upper limit on the total acquisition time and resolution achievable.
The rapamycin example illustrates the potential of full atomic scale imaging of single molecules based on naturally abundant nuclei, such as highly dense 1H atoms that detail the structure of organic molecules. However, for applications where only limited information is required (for example, conformation and/or ligand state/position), targeting characteristic nuclear spin labels (that is, 14,15N, 13C, 31P) 12 nm apart, can be achieved up to two orders of magnitude faster compared with full atomic scale imaging. This is a consequence of order of magnitude reductions in both the required number of interaction slices and the measurement sequence length t. In this case, the requirements on the probes coherence times decrease to the 3 5 ms range, with further 23 orders of magnitude reduction in eld strength needed for nuclear decoupling pulses. This opens up experimental applications in room temperature individual moleculeconformational mapping based on NV centre in diamond, particularly for conformation detection based on electron spin labels46 for which there is an additional three orders of magnitude speed up due to the stronger magnetic moment. In this case the probes transverse coherence time is required to be in the microsecond range or greater which is commensurate with current values for near-surface NV centres11,40,47.
DiscussionIn conclusion, we have introduced a new concept for a nano-MRI molecular microscope system based on a generic quantum spin probe, and showed by direct quantum simulation that it allows for the determination of single-molecule structure to high resolution. In this approach, the quantum probe acts as both MRI sensor and gradient eld, encoding the targets real-space spin density in frequency space. The key to the system is a carefully designed protocol interleaving nuclear spin decoupling and phase accumulation on the probe. By systematically performing measurements on the quantum probe over many positions and orientations of the probe-target interaction slices, the probe acquires information about the nuclear spin density in the target molecule. After the deconvolution procedure the nuclear spin density can be mapped out and the atomic coordinates determined. The technique was tested on a non-trivial examplethe rapamycin moleculeusing a rudimentary sampling procedure and quantum probe coherence parameters already achieved experimentally for phosphorus spin qubits in silicon36,37. The resolution and average structural errors were found to be at the angstrom level and below. Further improvements and optimization are expected to greatly reduce the overall acquisition time which here should be considered as an upper limit. The protocol length, frequency steps and ne driving eld can be rened through a nonlinear rate of change of
the probe interaction eld, leading to more efcient molecular imaging with uniform resolution through the sampled volume. Our imaging method is suitable for molecules considerably larger than the presented example. Targets of 420 kDa would benet signicantly from adaptive sampling, that is, starting from a fast low resolution density estimate and iteratively modifying the sampling parameters together with orientation of the interaction slices. For aggregate protein structures of signicant spatial extent (10 s of nanometers), an addition of an external classical gradient eld (for example, a magnetic tip) could provide a pathway to remote spatio-frequency encoding. However, more work needs to be done to demonstrate the level of decoupling achievable in the classical gradient elds, experimental timescales required to detect variations of the nuclear spin density at such distances, and the additional inuence of the gradient on the quantization axis of both the target and probe spins. The use of more effective decoupling pulses could also have signicant impact on the efciently of the total detection protocol. The protocol was presented for the case of a general spin probe, however, the experimental parameters considered are consistent with current coherence measurements of phosphorus qubits in silicon (Si:P). In the case of the NV spin one could implement a pulsed background eld, or attach the molecular sample to an AFM tip scanned through the static eld, to avoid off-axis contrast loss, in addition to engineering both appropriate surface and isotopic properties of diamond required to achieve higher electron spin coherence times. The detection protocol outlined here utilises only a single electronic spin and, as such, it is limited by the transverse coherence time of the probe T2p. An additional storage qubit, such as the nuclear spin available in both NV and Si:P implementations, can be utilised during the control rotation phase by swapping signal information on the electron spin to the nuclear spin4851 to signicantly extend the detection limit to the probes longitudinal T1p coherence time. With straightforward sample preparation of molecular targets in their in situ environments, for example, hydrated and coupled protein-drug systems, and hybrid options for adding extra sources of gradient elds (for example, by site-directed spin labelling) to scale up to larger biomolecules, quantum probe-based MRI has signicant potential for true single-molecule microscopy.
Methods
Homo-nuclear decoupling. Suppression of coupling between nuclear spins is routinely performed in solid state NMR, by physical or Hilbert-space rotations52. Physical rotations around the dipoledipole magic-angle axis have proveduseful in practice, however, nanometer scale rotations of a single molecule relative to a single spin probe are outside the reach of immediate technology, thus we propose Hilbert-space techniques to achieve the same result. Out of multiple families of Hilbert-space approaches, the two dominate branches in the group of on-resonance pulses are the solid-echo and magic-echo27,52,53 based sequences. The former utilise multi-axis 90 pulses to perform effective spin rotation about the magic-angle axis, and the latter are based on 360 pulses. Without loss of generality, we consider the solid-echo type sequences and show how they can be integrated with control rotations on the nuclear spins.
These decoupling sequences are made up of unit blocks of the following form:t D p2
x t D p2
y 2t D p2
y t D p2
x t where D p2
x;y
are 90 square pulses around positive/negative x or y axis, and t is the free evolution time of appropriate duration53.
Hilbert space decoupling approaches are designed for conventional NMR techniques under uniform background magnetic elds, therefore their application in a gradient eld regime requires detailed consideration. A dipoledipole NMR spectrum of a molecule in a uniform magnetic eld B0 is symmetric around the frequency set by the background eld gnB0, where gn is the nuclear gyromagnetic ratio. The square decoupling pulses are also centred around the same frequency, but have a spectral spread wider than the dipolar molecular NMR spectrum. This ensures appropriate narrowing of the spectrum towards the background frequency gnB0. In contrast to classical gradient elds, we can choose to maintain this symmetry of the NMR spectrum by keeping the probe spin in an equal superposition throughout application of the decoupling pulses, while keeping the free precession time equal to the full number of background eld periods t nd2p/gnB0, ndAN.
The probe itself does not participate in the effective magic-angle spinning as its
8 NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667 ARTICLE
electronic spin has different resonant frequency. In turn the probe coupling terms to each of the nuclei, GS(yB , fB ;r), remain unaffected and dene the interaction slices characterized by polar direction (yB , fB ) of the background magnetic eld B0. This feature allows the spin-echo sequence on the probe to refocus the phase offsets encountered by nuclear spins on different interaction slices, thus maintaining their coherence under the gradient coupling regime.
3D imaging protocol. This section details the general steps leading to the generation of the 3D spatial image of the molecular nuclear density. The primary sampling is done by sweeping the ne driving frequency o in discrete steps of do from omin to omax. The upper frequency limit omax is set by the value of the interaction at the substrate surface, immediately below the molecule. The lower frequency bound omin must be no greater than the minimal coupling experienced in the molecule, spatially associated with the uppermost part of the molecule.
Relative to the probe, the physical shape of a resonant interaction slice is dened by a equipotential of the coupling eld between the probe and the nuclei having value equal to o. In frequency space, the spectral broadening of the signal generated by the power of the driving eld BR is set equal to the sampling step do, ensuring sufcient spectral coverage. In real space, the dipole slice corresponds to a spatial region of non-uniform width, depending on the strength of the driving eld BR and the gradient of the coupling eld.
The signal values generated by the frequency sweep contain relative information about the number of nuclear spins located on each of the interaction slices. The orientations of the interaction slices depends on the direction of the quantisation axis (Fig. 4). The frequency sampling is performed for multiple orientation of the quantization axis by reorienting the background magnetic eld B0, in discrete latitude steps of dyB from yBmin to yBmax and azimuthal steps of dfB from 0 to 2p.
We note that the signal for each resonant slice is a product of individual nuclear spin signals. This characteristic has to be considered both from sampling and from data processing perspectives. As a function of time, the signal approaches zero as the number of spins on a resonant slice increases. An appropriate choice of the ne driving strength BR and the sequence length t has to be made. To yield optimal results this calibration can be optimised dynamically for a particular molecule of interest as part of the initial frequency sweep. Alternatively the sampling can be performed for several sequence lengths.
Given the signal exhibits a product structure, we devise a self-scaled derivative (SSD) approach to linearisation. We dene the SSD, Si*(x) of a single signal function, Si*(x), with respect to a given parameter x as:
S ix
1 Six
@x : 7 As the total signal is a product of signals of all N nuclei in the molecule, it follows that the SSD of the total signal with respect to a variable x transforms from product to linear structure:
S x X
n
i1
@Six
S ix: 8
The data is linearized by computing the SSD for each frequency sweep with respect to the ne driving frequency o. To obtain the MRI spectrum we perform a one-dimensional deconvolution to the frequency sweep data. The natural choice for the point spread function is the single nuclei spin response SSD function, Si*,
symmetrically centred in the sweep range. The deconvolution step removes signal contributions of the spins on the neighbouring interaction slices, ensuring that the data linearly reects the number of spins present at their corresponding slice.
To form the nuclear density image, the volume containing the molecule is discretized into n m q segments separated by a dl[] step. We construct a
transform M such that S M q where q is a vectorized 3D nuclear density, and S
is the equivalent form of the measured signal for all slice orientations. Each row of the matrix M represents a discretised 3D map corresponding to a single interaction slice. The nuclear spin density is obtained by numerical inversion. This general approach is unconstrained by the shape of the resonate slices. From the 3D density image, atomic coordinates are extracted by observing the positions of the local maxima.
Parameters for the the molecule example. For clarity, the method is demonstrated for a probe with a well-localized electronic spin, thus the interaction slices correspond to equipotential slices of the secular dipoledipole coupling eld:
GS
; 9
B0 B0sinyB cosfB ; sinyB sinfB ; cosyB 10 where r is a given nuclear coordinate vector relative to the probe in the lab frame and B0 is the constant magnitude background magnetic eld controlled by polar direction parameters (yB , fB ).
The parameters chosen for the simulation are as follows: the ne frequency sweeping range was omin 100 rad s 1, omax 15 krad s 1 with the sampling
step of do 100 rad s 1 (o oS is a resonance condition for probing nuclei in the
slice oS). The frequency sweeps were conducted for a range of orientations as given by latitude parameters yminB p=24, ymaxB 11p=24, and dyB p=24 and
longitude steps dfB p/12. Each point was sampled at a xed protocol length of
tH 8 ms for 1H nuclei and tC 16 ms for 13C nuclei, with MS 2000
measurements per slice. The transverse coherence time of the probe and the effective coherence time of the nuclear spins were set to be respectively T2p 50 ms
and T2n 50 ms. Such coherence times are already established for the Si:P system,
and with suitable cooling and material improvements may be possible for the NV centre.
To obtain nuclear density images in 3D, the region around the molecule, xE( 1,1) nm, yE( 1,1) nm and zE(3.5,5) nm was discretized in cubic voxel of side
length dl 0.5 , the inversion of the map M was performed by numerical least-
square based approach5456.
Quantum simulations. Features of the numerical simulations (Fig. 3) performed to investigate the behaviour of the detection protocol (Fig. 2i) are characterized by the full quantum Hamiltonian, containing nuclear dipoledipole interactions between individual nuclei and probe spins as well as between all nuclei themselves. This is a crucial requirement for accurate investigation of intricate dynamics between the homo-nuclear decoupling part of the detection sequence and the ne driving that transfers the relative spatio-frequency coded information about the nuclear spin density to the phase of the probe spin. The second requirement is for both the strong decoupling pulses as well as the ne driving pulses to be introduced, on the Hamiltonian level, as physical elds of appropriate amplitude shape and length. We model both of these pulse types as square in shape reecting readily used experimental approaches as well as lowering computational requirements needed compared with Gaussian or Sinc shaped pulses that would in principle give better permanence to the total detection protocol. In contrast, unitary matrix operations are sufcient to capture the control of the electronic probe spin, since the required pulses are relatively fast with frequencies are well outside the nuclear spin range. The initial state of the nuclear target spins is dominated by high temperature regime due to strong dipoledipole interactions, and can be well captured by mixed state density matrix representation. The coherence of the target nuclei depends strongly on their quantum interactions with one another, while the probe spin can be sufciently well modelled through an additional explicit Lindblad term designed to model its decoherence properties unrelated to the presence of the molecular nuclei (such as a 29Si bath for Si:P probe, or 13C bath for NV-centre). Note, the nuclei-probe dipoledipole interaction in conjunction with decoupling properties of the detection protocol automatically affects the coherence of the probe spin beyond the explicit Lindblad term.
Data availability. All relevant data are available from the authors on request.
References
1. Doherty, M. W. et al. The nitrogen-vacancy colour centre in diamond. Phys. Rep. 528, 145 (2013).
2. Rondin, L. et al. Magnetometry with nitrogen-vacancy defects in diamond. Rep. Prog. Phys. 77, 056503 (2014).
3. Zhao, N. et al. Sensing single remote nuclear spins. Nat. Nanotechnol. 7, 657662 (2012).
4. Taminiau, T. H. et al. Detection and control of individual nuclear spins using a weakly coupled electron spin. Phys. Rev. Lett. 109, 137602 (2012).
5. Laraoui, A. et al. High-resolution correlation spectroscopy of 13c spins near a nitrogen-vacancy centre in diamond. Nat. Commun. 4, 1651 (2013).
6. Shi, F. et al. Sensing and atomic-scale structure analysis of single nuclear-spin clusters in diamond. Nat. Phys. 10, 2125 (2014).
7. Rugar, D. et al. Proton magnetic resonance imaging using a nitrogen-vacancy spin sensor. Nat. Nanotechnol. 10, 120124 (2015).
8. Loretz, M., Pezzagna, S., Meijer, J. & Degen, C. L. Nanoscale nuclear magnetic resonance with a 1.9-nm-deep nitrogen-vacancy sensor. Appl. Phys. Lett. 104, 033102 (2014).
9. Mller, C. et al. Nuclear magnetic resonance spectroscopy with single spin sensitivity. Nat. Commun. 5, 4703 (2014).
10. Loretz, M. et al. Single-proton spin detection by diamond magnetometry. Science. doi:10.1126/science.1259464 (2014); retraction (2015).
11. Sushkov, A. O. et al. Magnetic resonance detection of individual proton spins using quantum reporters. Phys. Rev. Lett. 113, 197601 (2014).
12. DeVience, S. J. et al. Nanoscale NMR spectroscopy and imaging of multiple nuclear species. Nat. Nanotechnol. 10, 129134 (2015).
13. Haberle, T., Schmid Lorch, D., Reinhard, F. & Wrachtrup, J. Nanoscale nuclear magnetic imaging with chemical contrast. Nat. Nanotechnol. 10, 125128 (2015).
14. Zhao, N., Hu, J.-L., Ho, S.-W., Wan, J. T. K. & Liu, R. B. Atomic-scale magnetometry of distant nuclear spin clusters via nitrogen-vacancy spin in diamond. Nat. Nanotechnol. 6, 242246 (2011).
15. Cai, J., Jelezko, F., Plenio, M. B. & Retzker, A. Diamond-based single-molecule magnetic resonance spectroscopy. New J. Phys. 15, 013020 (2013).
16. Perunicic, V. S., Hall, L. T., Simpson, D. A., Hill, C. D. & Hollenberg, L. C. L. Towards single-molecule NMR detection and spectroscopy using single spins in diamond. Phys. Rev. B 89, 054432 (2014).
yB ; fB ; r gegn
m0 4p
1 3 1 3
^
B0 ^r2
NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 9
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms12667
17. Trifunovic, L. et al. High-efciency resonant amplication of weak magnetic elds for single spin magnetometry at room temperature. Nat. Nanotechnol. 10, 541546 (2015).
18. Ajoy, A., Bissbort, U., Lukin, M. D., Walsworth, R. L. & Cappellaro, P. Atomic-scale nuclear spin imaging using quantum-assisted sensors in diamond. Phys. Rev. X 5, 011001 (2015).
19. Kost, M., Cai, J. & Plenio, M. B. Resolving single molecule structures with nitrogen-vacancy centers in diamond. Sci. Rep. 5, 11007 (2015).
20. Laraoui, A., Pagliero, D. & Meriles, C. A. Imaging nuclear spins weakly coupled to a probe paramagnetic center. Phys. Rev. B 91, 205410 (2015).
21. Lazariev, A. & Balasubramanian, G. A nitrogen-vacancy spin based molecular structure microscope using multiplexed projection reconstruction. Preprint at https://arxiv.org/abs/1505.02904 (2015).
22. Wang, Z.-Y., Haase, J. F., Casanova, J. & Plenio, M. B. Positioning Nuclear Spins in Interacting Clusters for Quantum Technologies and Bio-imaging. Preprint at https://arxiv.org/abs/1510.02811 (2016).
23. Toukach, F. V. & Ananikov, V. P. Recent advances in computational predictions of NMR parameters for the structure elucidation of carbohydrates: methods and limitations. Chem. Soc. Rev. 42, 83768415 (2013).
24. Murray, D. T., Das, N. & Cross, T. A. Solid state NMR strategy for characterizing native membrane protein structures. Acc. Chem. Res. 46, 21722181 (2013).
25. Yan, S., Suiter, C. L., Hou, G., Zhang, H. & Polenova, T. Probing structure and dynamics of protein assemblies by magic angle spinning NMR spectroscopy. Acc. Chem. Res. 46, 20472058 (2013).
26. Sengupta, I., Nadaud, P. S., Helmus, J. J., Schwieters, C. D. & Jaroniec, C. P. Protein fold determined by paramagnetic magic-angle spinning solid-state NMR spectroscopy. Nat. Chem. 4, 410417 (2012).
27. Judge, P. J., Taylor, G. F., Dannatt, H. W. & Watts, A. Solid-State Nuclear Magnetic Resonance Spectroscopy for Membrane Protein Structure Determination, vol. 1261 of Methods in Molecular Biology. ch. 17 pp. 331347 (Springer, 2015).
28. Chapman, H. N. et al. Femtosecond x-ray protein nanocrystallography. Nature 470, 7377 (2011).
29. Boutet, S. et al. High-resolution protein structure determination by serial femtosecond crystallography. Science 337, 362364 (2012).
30. Cohen, A. E. et al. Goniometer-based femtosecond crystallography with x-ray free electron lasers. Proc. Natl Acad. Sci. 111, 1712217127 (2014).
31. Hattne, J. et al. Accurate macromolecular structures using minimal measurements from x-ray free-electron lasers. Nat. Methods 11, 545548 (2014).
32. Ma, W.-L. & Liu, R.-B. Angstrom-resolution magnetic resonance imaging of single molecules via wave-function ngerprints of nuclear spins. Phys. Rev. Applied 6, 024019 (2016).
33. Hanson, P. I., Roth, R., Morisaki, H., Jahn, R. & Heuser, J. E. Structure and conformational changes in nsf and its membrane receptor complexes visualized by quick-freeze/deep-etch electron microscopy. Cell 90, 523535 (1997).
34. Severs, N. J. Freeze-fracture electron microscopy. Nat. Protoc. 2, 547576 (2007).
35. Severs, N. J. & Robenek, H. Freeze-Fracture Cytochemistry in Cell Biology, Vol. 88 pp. 181204 (Academic Press, 2008).
36. Tyryshkin, A. M. et al. Electron spin coherence exceeding seconds in high-purity silicon. Nat. Mater. 11, 143147 (2012).
37. Muhonen, J. T. et al. Storing quantum information for 30seconds in a nanoelectronic device. Nat. Nanotechnol. 9, 986991 (2014).
38. Fuechsle, M. et al. A single-atom transistor. Nat. Nanotechnol. 7, 242246 (2012).39. Schoeld, S. R. et al. Phenyl attachment to si(001) via stm manipulation of acetophenone. J. Phys. Chem. C 117, 57365741 (2013).
40. Kaufmann, S. et al. Detection of atomic spin labels in a lipid bilayer using a single-spin nanodiamond probe. Proc. Natl Acad. Sci. USA 110, 1089410898 (2013).
41. Usman, M. et al. Spatial metrology of dopants in silicon with exact lattice site precision. Nat. Nanotechnol. 11, 763768 (2016).
42. Uhrig, G. S. Concatenated control sequences based on optimized dynamic decoupling. Phys. Rev. Lett. 102, 120502 (2009).
43. Cory, D. G. A new multiple-pulse cycle for homonuclear dipolar decoupling.J. Magn. Reson. 94, 526534 (1991).
44. Ohashi, K. et al. Negatively charged nitrogen-vacancy centers in a 5 nm thin 12c diamond lm. Nano Lett. 13, 47334738 (2013).
45. Osterkamp, C. et al. Stabilizing shallow color centers in diamond created by nitrogen delta-doping using sf6 plasma treatment. Appl. Phys. Lett. 106, 113109 (2015).
46. Hubbell, W. L., Lpez, C. J., Altenbach, C. & Yang, Z. Technological advances in site-directed spin labeling of proteins. Curr. Opin. Struct. Biol. 23, 725733 (2013).
47. Shi, F. et al. Single-protein spin resonance spectroscopy under ambient conditions. Science 347, 1351138 (2015).
48. Morton, J. J. L. et al. Solid-state quantum memory using the 31p nuclear spin. Nature 455, 10851088 (2008).
49. Pla, J. J. et al. A single-atom electron spin qubit in silicon. Nature 489, 541545 (2012).
50. Jelezko, F. et al. Observation of coherent oscillation of a single nuclear spin and realization of a two-qubit conditional quantum gate. Phys. Rev. Lett. 93, 130501 (2004).
51. Neumann, P. et al. Single-shot readout of a single nuclear spin. Science 329, 542544 (2010).
52. Klinowski, J. New Techniques in Solid-State NMR, vol. 246 of Topics in Current Chemistry (Springer, 2005).
53. Chan, J. C. C. Solid State NMR, vol. 306 of Topics in Current Chemistry (Springer, 2012).
54. Lawson, C. & Hanson, R. Solving Least Squares Problems ch. 23, 161 (Prentice-Hall, 1974).
55. Coleman, T. & Li, Y. A reective newton method for minimizing a quadratic function subject to bounds on some of the variables. SIAM J. Optim. 6, 10401058 (1996).
56. Gill, W., Murray, P. E. & Wright, M. H. Practical Optimization (Academic Press, 1981).
Acknowledgements
We thank J.-P. Tetienne, D. Simpson, A. Stacey and M. Usman for useful discussions. This work was partly supported by the Australian Research Council (ARC) under the Centre of Excellence scheme (project number CE110001027). L.C.L.H. acknowledges an ARC Laureate Fellowship (FL130100119).
Author contributions
V.S.P. and L.C.L.H. co-developed the interleaved quantum control protocol and the measurement protocol for the spin-probe-based 3D MRI. V.S.P., C.D.H., L.T.H. andL.C.L.H. developed the theoretical framework of the protocol. V.S.P. developed analytical and numerical models, and carried out simulations. V.S.P. and L.C.L.H. analysed the results and wrote the manuscript in consultation with all the authors.
Additional information
Competing nancial interests: The authors declare no competing nancial interests.
Reprints and permission information is available online at http://npg.nature.com/reprintsandpermissions/
Web End =http://npg.nature.com/ http://npg.nature.com/reprintsandpermissions/
Web End =reprintsandpermissions/
How to cite this article: Perunicic, V. S. et al. A quantum spin-probe molecular microscope. Nat. Commun. 7:12667 doi: 10.1038/ncomms12667 (2016).
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the articles Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
Web End =http://creativecommons.org/licenses/by/4.0/
r The Author(s) 2016
10 NATURE COMMUNICATIONS | 7:12667 | DOI: 10.1038/ncomms12667 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Oct 2016
Abstract
Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51 H79 NO13 ) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer