About the Authors:
Wolfgang Huber
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing
* E-mail: [email protected]
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Andrea Gruber
Roles Data curation, Formal analysis, Investigation, Methodology, Project administration, Software, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Maximilian Eckmann
Roles Data curation, Formal analysis, Investigation, Methodology, Project administration, Software, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Felicia Elkmann
Roles Data curation, Formal analysis, Investigation, Methodology, Project administration, Software, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Ines Klein
Roles Data curation, Formal analysis, Investigation, Methodology, Project administration, Software, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Tobias Lahmer
Roles Conceptualization, Data curation, Formal analysis, Investigation, Project administration, Supervision, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Ulrich Mayr
Roles Data curation, Formal analysis, Investigation, Project administration, Supervision, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Raphael Schellnegger
Roles Data curation, Formal analysis, Investigation, Project administration, Supervision, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Jochen Schneider
Roles Data curation, Formal analysis, Investigation, Project administration, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Gonzalo Batres-Baires
Roles Data curation, Formal analysis, Investigation, Project administration, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Lisa Fekecs
Roles Data curation, Formal analysis, Investigation, Project administration, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Analena Beitz
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Helena Berbara
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Roland Schmid
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Alexander Herner
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing
Affiliation: Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany
Abstract
Background
Transpulmonary thermodilution (TPTD) is used to derive cardiac output CO, global end-diastolic volume GEDV and extravascular lung water EVLW. To facilitate interpretation of these data, several ratios have been developed, including pulmonary vascular permeability index (defined as EVLW/(0.25*GEDV)) and global ejection fraction ((4*stroke volume)/GEDV). PVPI and GEF have been associated to the aetiology of pulmonary oedema and systolic cardiac function, respectively. Several studies demonstrated that the use of femoral venous access results in a marked overestimation of GEDV. This also falsely reduces PVPI and GEF. One of these studies suggested a correction formula for femoral venous access that markedly reduced the bias for GEDV. Consequently, the last PiCCO-algorithm requires information about the CVC, and correction for femoral access has been shown. However, two recent studies demonstrated inconsistencies of the last PiCCO algorithm using incorrected GEDV for PVPI, but corrected GEDV for GEF. Nevertheless, these studies were based on mathematical analyses of data displayed in a total of 15 patients equipped with only a femoral, but not with a jugular CVC.
Therefore, this study compared PVPI_fem and GEF_fem derived from femoral TPTD to values derived from jugular indicator injection in 25 patients with both jugular and femoral CVCs.
Methods
54 datasets in 25 patients were recorded. Each dataset consisted of three triplicate TPTDs using the jugular venous access as the gold standard and the femoral access with (PVPI_fem_cor) and without (PVPI_fem_uncor) information about the femoral indicator injection to evaluate, if correction for femoral GEDV pertains to PVPI_fem and GEF_fem.
Results
PVPI_fem_uncor was significantly lower than PVPI_jug (1.48±0.47 vs. 1.84±0.53; p<0.001). Similarly, PVPI_fem_cor was significantly lower than PVPI_jug (1.49±0.46 vs. 1.84±0.53; p<0.001). This is explained by the finding that PVPI_fem_uncor was not different to PVPI_fem_cor (1.48±0.47 vs. 1.49±0.46; n.s.). This clearly suggests that correction for femoral CVC does not pertain to PVPI.
GEF_fem_uncor was significantly lower than GEF_jug (20.6±5.1% vs. 25.0±6.1%; p<0.001). By contrast, GEF_fem_cor was not different to GEF_jug (25.6±5.8% vs. 25.0±6.1%; n.s.). Furthermore, GEF_fem_cor was significantly higher than GEF_fem_uncor (25.6±5.8% vs. 20.6±5.1%; p<0.001). This finding emphasizes that an appropriate correction for femoral CVC is applied to GEF_fem_cor.
The extent of the correction (25.5/20.6; 124%) for GEF and the relation of PVPI_jug/PVPI_fem_uncor (1.84/1.48; 124%) are in the same range as the ratio of GEDVI_fem_uncor/GEDVI_fem_cor (1056ml/m2/821mL/m2; 129%). This further emphasizes that GEF, but not PVPI is corrected in case of femoral indicator injection.
Conclusions
Femoral indicator injection for TPTD results in significantly lower values for PVPI and GEF. While the last PiCCO algorithm appropriately corrects GEF, the correction is not applied to PVPI. Therefore, GEF-values can be used in case of femoral CVC, but PVPI-values are substantially underestimated.
Figures
Table 3
Fig 2
Fig 3
Table 1
Table 2
Fig 1
Table 3
Fig 2
Fig 3
Table 1
Table 2
Fig 1
Citation: Huber W, Gruber A, Eckmann M, Elkmann F, Klein I, Lahmer T, et al. (2017) Comparison of pulmonary vascular permeability index PVPI and global ejection fraction GEF derived from jugular and femoral indicator injection using the PiCCO-2 device: A prospective observational study. PLoS ONE12(10): e0178372. https://doi.org/10.1371/journal.pone.0178372
Editor: Jörn Karhausen, Duke University, UNITED STATES
Received: November 4, 2016; Accepted: May 11, 2017; Published: October 17, 2017
Copyright: © 2017 Huber et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: Due to ethical and legal restrictions imposed by Ethikkommission der Fakultät für Medizin der Technischen Universität München, confidential data are available upon request. To receive anonymized data readers are welcome to contact the corresponding author (Prof. Dr. Wolfgang Huber, II. Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Strasse 22, D-81675 München, Germany. Fax: 0049-89-4140-4808. E-mail: [email protected]). Dr. Georg Schmidt, an affiliate of Ethikkommission der Fakultät für Medizin der Technischen Universität München, may be contacted at [email protected].
Funding: The authors received no specific funding for this work.
Competing interests: Wolfgang Huber is member of the Medical Advisory Board of Pulsion Medical Systems SE, Feldkirchen, Germany. All other authors have no conflict of interest. This does not alter the authors' adherence to PLOS ONE policies on sharing data and materials.
Background
Transpulmonary thermodilution (TPTD) and pulse contour analysis (PCA) are among the most frequently used techniques of modern haemodynamic monitoring. Both principles have been used separately in the 1st generation COLD-device (TPTD) [1] or the FloTrac and ProAqt-technology (PCA) [2,3]. At least three commercially available devices combine TPTD and PCA (PiCCO [4], EV-1000 [5] and LiDCO [6]). Combination of TPTD and PCA provides intermittent calibration of cardiac index CI by TPTD as well as continuous assessment of CI, variabilities of the arterial pressure curve such as stroke volume variation (SVV) and pulse pressure variation (PPV). Furthermore, the contractility-index dPmax is continuously derived by PCA. In addition to CI, TPTD provides extravascular lung water EVLW, a marker of pulmonary oedema [1,7–11], and the preload marker global end-diastolic volume GEDV [12–14].
Although an increasing number of parameters are easily and in part continuously derived, the interpretation of numerous parameters is challenging. To facilitate interpretation of these data several ratios (Table 1) have been developed. These ratios are used as a kind of “decision support”, including pulmonary vascular permeability index (defined as EVLW/(0.25*GEDV)), global ejection fraction (defined as (4*stroke volume)/GEDV), cardiac power index (CPI), cardiac function index (CFI).
[Figure omitted. See PDF.]
Table 1. Ratios and formulas derived from (transpulmonary) thermodilution and pulse contour analysis.
https://doi.org/10.1371/journal.pone.0178372.t001
Several studies demonstrated that these parameters are associated to outcome. Therefore, they might be useful to guide therapy [15–23].
PVPI, GEF and CFI have been associated to the aetiology of pulmonary oedema and systolic cardiac function, respectively. However, a number of studies demonstrated that the use of femoral venous access results in a marked overestimation of GEDV [5,24,25]. Overestimation of GEDV also falsely reduces PVPI, GEF and CFI [26,27]. One of these studies suggested a correction formula for femoral venous access that markedly reduces the bias compared to jugular TPTD derived GEDV_jug [24]. Consequently, the last PiCCO-algorithm requires information about the CVC, and correction for femoral access has been shown. However, two recent studies suggested inconsistencies of the last PiCCO algorithm using uncorrected GEDV for PVPI [26], but corrected GEDV for GEF and CFI [27]. Despite their conclusive results, these studies were based on mathematical analysis of data displayed by the PiCCO in a total of 15 patients equipped with only a femoral, but not with a jugular CVC.
Therefore, it was the aim of our study to validate the findings of these studies by direct comparison of PVPI_fem and GEF_fem derived from femoral TPTD to values derived from jugular indicator injection in 25 patients with both jugular and femoral CVCs.
Materials and methods
The institutional review board approved the study (Ethikkommission; Fakultät für Medizin; Technische Universität München 3049/11s). The need for written informed consent from the participants was waived by the review board due to the observational design of the study in accordance with clinical routine in case of different central venous accesses for TPTD-indicator injection. Our institutional SOP for extended haemodynamic monitorings recommends to perform 1–2 additional triplicate TPTDs in case of different CVC-sites used for TPTD to make these measurements better comparable and interpretable. This prospective observational study was conducted in an eight bed general ICU at a university hospital between March 18, 2013 and April 30, 2016. None of the patients has been included in one of the studies or databases previously used for comparison of TPTD-parameters derived from jugular to femoral indicator injection [5,24,26,27].
We prospectively recorded 54 datasets in 25 patients with both jugular and femoral CVC. Each dataset consisted of three triplicate TPTDs with 15ml cold saline solution: The jugular venous access was used as the gold standard TPTD_jug. Two triplicate TPTDs were performed using the femoral access with (TPTD_fem_cor) or without (TPTD_fem_uncor) information about the femoral indicator injection to evaluate, if correction for femoral GEDV pertains to PVPI_fem and GEF_fem.
To avoid a systematic bias by repeated TPTDs with a total volume of 9*15mL, the three TPTDs were performed in a random order.
The majority (29 out of 54 measurements (54%)) of measurements were performed in patients with both a conventional CVC and a dialysis catheter. In general, CVC and dialysis catheters were inserted in different positions (one in the vena cava superior and the other one in the vena cava inferior). The dialysis catheters were inserted into the femoral and into the jugular vein in 15 (26%) and 14 (28%) of 54 measurements, respectively. In 25 of 54 (46%) measurements two conventional CVCs in opposite positions were used for TPTD.
Indicator injections were performed via a 5-lumen CVC (Multicath 5, Vygon; Aachen, Germany) with a maximum intravascular length of 20 cm and a diameter of 3.15 mm (9.5 Fr) or via a Gambro Gam Cath Dolphin dialysis-catheter (Gambro Gam Cath Dolphin; Gambro Hospal GmbH, Gröbenzell, Germany). Dialysis catheters with a length of 250 mm and a diameter of 13 F were used for femoral access, and catheters with a length of 150–175 mm and a diameter of 13 F were used for jugular RRT-access, respectively. Since the larger volume of the dialysis catheters (up to 1.6ml) might result in a loss of indicator (1.6mL of 15mL, i.e. 11% of the indicator) and in an overestimation of volumetric parameters for the 1st of TPTD-measurement, the dialysis catheters were prefilled with ice cold saline immediately before the 1st indicator injection. The vascular part of the femoral venous catheter was completely inserted under ultrasound guidance. The position of the tip was controlled (and corrected) according to X-ray in case of jugular, but not in case of femoral venous catheter access.
The registration of the arterial TPTD curve was performed as previously described [24,28,29] using a 5-French thermistor-tipped arterial catheter (PV2015L20-A PiCCO catheter; Pulsion Medical Systems SE, Feldkirchen, Germany) with a length of 20cm (5 Fr) placed in the femoral artery and a PiCCO-2-monitor (Pulsion Medical Systems SE, Feldkirchen Gemany).
All PiCCO-2-devices were equipped with the V3.1. algorithm requiring information about the venous catheter site.
Statistical analyses
All statistical analyses were performed using the IBM SPSS Statistics software version 23 (SPSS Inc., Chicago, IL, USA). The collected data was examined for input data error. Continuous variables are expressed as mean±standard deviation. Categorical variables are expressed as percentages. To compare continuous variables we used Wilcoxon-test for paired samples.
Bland-Altman analysis was used to analyze the agreement between variables derived from jugular and femoral venous catheter sites for both PVPI and GEF as well as to compute the percentage error. The agreement of classification of PVPI (PVPI ≥3; <PVPI<3; PVPI ≤1) derived from different measurements was primarily analyzed using Fisher´s exact test (“agreement yes or no”). Additionally, we calculated kappa-statistics and Kendall´s coefficient of correlation.
To account for different numbers of measurements per patient (range 1–4), analyses were performed for the first measurement in each patient (n = 25; secondary endpoint) in addition to the analysis of all 54 measurements (primary endpoint).
Statistical significance was defined as p<0.05.
Results
Patients´ characteristics are summarized in Table 2
[Figure omitted. See PDF.]
Table 2.
https://doi.org/10.1371/journal.pone.0178372.t002
Comparison of PVPI-measurements using different indicator injection sites (all measurements)
In the totality of all 54 measurements PVPI_fem_uncor was significantly lower than PVPI_jug (1.48±0.47 vs. 1.84±0.53; p<0.001). This resulted in a bias of -0.35±0.36 and a percentage error of 41.2% (S1 Fig, Fig 1A).
[Figure omitted. See PDF.]
Fig 1.
1A-1F: Bland Altman plots comparing (1A) pulmonary vascular permeability index PVPI_fem_uncor derived from femoral injection without activating of a potential correction by the device to the gold standard measurement PVPI_jug using a jugular CVC for indicator injection, (1B) pulmonary vascular permeability index PVPI_fem_cor derived from femoral injection after activiation of a potential correction by the device to the gold standard measurement PVPI_jug using a jugular CVC for indicator injection, (1C) pulmonary vascular permeability index PVPI derived from femoral indicator injection with (PVPI_fem_cor) and without (PVPI_fem_uncor) activation of a potential correction by the device, (1D) pulmonary vascular permeability index PVPI derived jugular indicator injection PVPI_jug to PVPI-fem_uncor_form which was derived from femoral indicator injection without activation of a potential correction by the device, but correction based on the formula suggested for correction of femoral indicator injection derived GEDVI: GEDVIcorrected [mL / m2] = 0.539 * GEDVIuncorrected—15.17 + 24.49 * CIuncorrected 2.311* BWideal. PVPI_fem_uncor_form was calculated by multiplying PVPI_fem_uncor with the ratio 0.25*GEDVuncorrected/0.25*GEDVcorrected, (1E) global ejection fraction GEF_fem_uncor derived from femoral injection without activating of a potential correction by the device to the gold standard measurement GEF_jug using a jugular CVC for indicator injection, (1F) global ejection fraction GEF_fem_cor derived from femoral injection after activiation of a potential correction by the device to the gold standard measurement GEF_jug using a jugular CVC for indicator injection, (1G) global ejection fraction GEF derived from femoral indicator injection with (GEF_fem_cor) and without (GEF_fem_uncor) activation of a potential correction by the device.
https://doi.org/10.1371/journal.pone.0178372.g001
The coefficients of variation (CV) were in the same range for PVPI_jug and PVPI_fem_uncor (29% and 32%, respectively).
Similarly, PVPI_fem_cor was significantly lower than PVPI_jug (1.49±0.46 vs. 1.84±0.53; p<0.001; S1 Fig; Fig 1B) with a bias of -0.35±0.36 and a percentage error of 43.0%.
This is explained by the finding that PVPI_fem_uncor was not different to PVPI_fem_cor (1.48±0.47 vs. 1.49±0.46; p = 0.614.; S1 Fig; Fig 1C) with a bias of -0.002±0.16 and a percentage error of 21.1%. Furthermore, the CV-values were in the same range for PVPI_fem_cor and PVPI_fem_uncor (31% and 32%, respectively).
This strongly suggests that the correction for femoral CVC does not pertain to PVPI.
The relation of PVPI_jug/PVPI_fem_uncor (1.84/1.48; 124%) is in the same range as the ratio of GEDVI_fem_uncor/GEDVI_fem_cor (1056ml/m2/821mL/m2; 129%).
Therefore, PVPI_fem_form was calculated by correcting PVPI_fem_uncor by multiplication of PVPI_fem_uncor with the ratio GEDVI_fem_uncor/GEDVI_fem_cor using the recently suggested correction formula for GEDVI_fem [24]:
Consequently, for ex-post-correction of PVPI_fem_uncor we calculated PVPI_fem_uncor_form by multiplying PVPI_fem_uncor with the ratio GEDVI_fem_uncor/GEDVI_fem_cor:
PVPI_fem_uncor_form was not significantly different from the gold standard PVPI_jug (1.89±0.57 vs. 1.84±0.53; p = 0.368; S1 Fig; Fig 1D) with a bias of 0.06 and a percentage error of 40.1%. The CV-values were comparable for PVPI_fem_uncor_form and PVPI_jug (30% and 29%, respectively).
To evaluate the impact on the potential clinical decision process we compared the distribution of PVPI-values in accordance with ALI/ARDS (PVPI ≥3) or hydrostatic pulmonary oedema (1<PVPI<3) or outside these classifications (PVPI ≤1) for the “gold-standard” PVPI_jug vs. the classifications according to PVPI_fem_uncor and PVPI_fem_uncor_form, respectively (Table 3). The agreement of PVPI_fem_uncor was 43 out of 54 (79.6%) which was significantly different to the gold standard of PVPI_jug (p<0.001; Fisher´s exact test). The agreement of PVPI_fem_uncor_form was 50/54 (92.6%), which was not significant different to PVPI_jug (p = 0.059).
[Figure omitted. See PDF.]
Table 3. Measurements of pulmonary permeability index PVPI_fem_uncor and PVPI_jug categorized “PVPI ≥3”, “1<PVP<3” and “PVPI≤1”.
Measurements classified in the same category are depicted in bold letters.
https://doi.org/10.1371/journal.pone.0178372.t003
Furthermore, kappa-statistics and Kendall´s coefficient of correlation confirm a significant agreement with PVPI_jug for PVPI_fem_uncor_form (kappa = 0.308; p = 0.002; Kendall´s coefficient of correlation = 0.357; p = 0.009), but not for PVPI_fem_uncor (kappa = 0.100; p = 0.259; Kendall´s coefficient of correlation = 0.156; p = 0.152).
Assuming that GEDVI_cor, but not PVPI_cor is corrected for femoral indicator injection we calculated PVPI_cor_calc based on EVLW_cor and GEDV_cor (GEDV_cor = GEDVI_cor * predicted body surface area (BSA); EVLW_cor = EVLWI_cor * predicted bodyweight; PVPI_cor_calc = EVLW_cor/0.25*GEDV_cor). Interestingly, PVPI_cor_calc was significantly higher than PVPI_cor (1.97±0.50 vs. 1.49±0.46; p<0.001). Although PVPI_cor_calc was also slightly higher compared to PVPI_jug (1.97±0.50 vs. 1.84±0.53; p = 0.006), the amount of the difference PVPI_cor_calc—PVPI_jug was substantially smaller than for the difference PVPI_cor—PVPI_jug (0.13±0.34 vs. 0.35±0.35; p<0.001).
While the bias compared to PVPI_jug was slightly higher for PVPI_cor_calc than for PVPI_uncor_form, the agreement with the previously mentioned three classifications (PVPI ≤1), 1<PVI<3 and PVPI ≥3 of PVPI_jug was 53 out of 54 (98.1%) for PVPI_cor_calc. This distribution was not significant different to PVPI_jug, and the agreement was significantly better than for PVPI_uncor (53 out of 54 vs. 43 out 54; p = 0.004).
Furthermore, kappa-statistics and Kendall´s coefficient of correlation confirm significant agreement of PVPI_fem_cor_calc with PVPI_jug (kappa = 0.486; p<0.001; Kendall´s coefficient of correlation = 0.507; p<0.001).
Comparison of PVPI-measurements using different indicator injection sites (first measurement in each patient)
To account for different numbers of measurements per patient, we separately analysed the first measurements of each patient (n = 25). In general, these analyses confirmed the primary analyses of all 54 datasets:
PVPI_fem_uncor and PVPI_fem-cor were not significantly different (1.46±0.50 vs. 1.43±0.43; p = 0.498). However, both were significantly lower compared to PVPI_jug (1.73±0.51; p<0.001 for both comparisons). This underlines that in case of femoral CVC an uncorrected GEDVI is used to calculate PVPI, even if the correct information of the femoral CVC-position is given to the device.
Comparison of GEF-measurements using different indicator injection sites (all measurements)
GEF_fem_uncor was significantly lower than GEF_jug (20.6±5.1% vs. 25.0±6.1%; p<0.001; percentage error 28.7%; S2 Fig; Fig 1E).
By contrast, GEF_fem_cor was not different to GEF_jug (25.6±5.8% vs. 25.0±6.1%; n.s.; percentage error 26.3%; S2 Fig; Fig 1F). Furthermore, GEF_fem_cor was significantly higher than GEF_fem_uncor (25.6±5.8% vs. 20.6±5.1%; p<0.001; percentage error 27.0%; S2 Fig; Fig 1G). These findings emphasize that an appropriate correction for femoral CVC is applied to GEF_fem_cor.
The extent of the correction (25.5/20.6; 124%) for GEF by giving the information of the femoral indicator injection and the relation of PVPI_jug/PVPI_fem_uncor (1.84/1.48; 124%) are in the same range as the ratio of GEDVI_fem_uncor/GEDVI_fem_cor (1056ml/m2/822mL/m2; 128%). This further suggests that GEF, but not of PVPI is corrected in case of femoral indicator injection.
Comparison of GEF-measurements using different indicator injection sites (first measurement in each patient)
Also for GEF, the analyses of the first measurement in each patient confirmed the findings of the analyses of all datasets: Despite a slight, but statistically significant overestimation GEF_fem_cor was comparable to GEF_jug (26.4±6.3% vs. 25.2±6.6%; p = 0.043; bias 1.1±2.6%; PE 19.5%). However, both GEF_jug and GEF_fem_cor were significantly higher compared to GEF_fem_uncor (21.1±5.5%; p<0.001 for both comparisons).
Discussion
Several recent studies suggest a marked overestimation of GEDV(I) and an underestimation of PVPI in case of using a femoral CVC for indicator injection compared to the gold standard of jugular injection. Interestingly, a similar phenomenon was found in case of a misplacement of the subclavian central venous catheter tip into the jugular vein [30]. One of these studies suggested a correction formula for GEDVI derived from femoral indicator injection. This formula is based on GEDVI_fem_uncor, CI_fem_uncor and ideal bodyweight [24].
This formula appropriately corrected GEDVI in a small validation cohort. Furthermore, several studies suggest that a similar formula has been integrated to the last PiCCO-2-algorithm. However, based on mathematical analyses of the data displayed for PVPI and GEF, two recent studies demonstrated that PVPI obviously is not corrected for femoral injection, whereas the values for GEF were in line with a correction for femoral indicator injection [26,27]. Since analyses were performed in small cohorts with only femoral CVCs, the final prove of these results in patients equipped with both jugular and femoral catheters remained to be demonstrated.
Therefore, we performed three triplicate TPTDs in patients with a CVC in the jugular (one triplicate TPTD) and in the femoral vein (two triplicate TPTDs). This setting allowed for comparison of uncorrected and potentially corrected parameters derived from femoral CVC to the corresponding values derived from jugular indicator injection. Furthermore, to the best of our knowledge this study was the first to compare TPTD parameters derived from femoral indicator injection with and without giving the information about the correct catheter site to the PiCCO-device equipped with the last algorithm requiring information about the catheter site. Using this approach we were also able to analyse, if and to which extent parameters derived from femoral indicator injection are corrected by the device.
The study investigated six key questions:
1.) Does the last PiCCO-2 algorithm correct GEDVI derived from femoral indicator injection TPTD?
Regarding this issue, our data demonstrated that GEDVI_fem_uncor was substantially corrected to derive GEDVI_fem_cor which was about 22% lower (mean values of 1056 mL/m2 and 822ml/m2, respectively).
2.) Is the correction of GEDVI_fem applied to PVPI_fem_uncor?
Furthermore, this study showed that PVPI derived from femoral indicator injection markedly underestimates PVPI_jug. Similar underestimation for PVPI_fem_uncor and PVPI_fem_cor as well as the absence of a difference between PVPI_fem_uncor and PVPI_fem_cor suggest that PVPI derived from femoral indicator injection is not corrected at all, irrespective of the information about the catheter site given to the device. This means that the device “ignores” the information about femoral CVC with regard to PVPI. As demonstrated by the distribution of PVPI-values categorized as in line with “ARDS/ALI (PVPI≥3)”, with “hydrostatic pulmonary oedema (1<PVPI<3)” and “outside of these two categories (PVPI≤1)” was substantially different for TPTDs derived from jugular and femoral TPTDs.
3.) Is PVPI_fem reproducible, or is femoral indicator injection derived PVPI “instable” per se?
Based on the evidence that PVPI_fem is not corrected at all, the two measurements of PVPI_fem_cor and PVPI_fem_uncor can be compared to analyze accuracy and precision of femoral TPTD-derived PVPI. A low bias of -0.002±0.16, a percentage error of 21.1% and similar CV-values (0.31 and 0.32, respectively) for the comparison of PVPI_fem_cor and PVPI_fem_uncor are in line with a precise and accurate femoral measurement of PVPI when compared to each other.
4.) Can PVPI_fem_(un)cor be corrected by the previously suggested formula with an acceptable bias?
Mathematical application of the previously suggested correction formula for GEDVI_fem to PVPI_fem_uncor resulted in an accurate correction as evidenced by the comparison of the mean values of PVPI_jug and PVPI_fem_uncor_form with a low bias of 0.06 as well as by a similar distribution of their clinical relevant categories.
5.) Can PVPI_fem_(un)cor be corrected by the previously suggested formula with an acceptable precision?
Since the percentage error has been introduced as a measure of precision of cardiac index derived from different methods compared to a gold standard technique, the application of PE and its critical threshold to other parameters has to be done with caution. This applies in particular to the use of the PE for combined formulas such as GEF and PVPI, since imprecisions of the different components might add up. Therefore, the previous study on femoral indicator injection TPTD restricted the application of PE to comparisons of CI and did not report PEs for EVLWI, GEDVI or PVPI [24].
At first glance, higher PE-values between 40.1% and 43.0% for all measurements derived from femoral indicator injection compared to PVPI_jug suggest that correction for PVPI_fem with appropriate precision regarding PVPI_jug might be more complex. This can be explained by the interdependent calculation of EVLW and PBV when using the single indicator TPTD technique. According to this approach an overestimation of GEDV and PBV necessarily results in an underestimation of EVLW, since EVLW is estimated as the difference of pulmonary thermo-volume PTV minus 0.25*GEDV. This interdependent calculation of two components of PVPI (i.e. EVLW and GEDV) might also explain a small number of outliers (see No. 42 and 46 in S1 Fig) and the higher PE-values for PVPI_fem-uncor_form of 40.1% even after ex-post correction by the previously suggested formula, since only GEDV, but not EVLW were corrected by this approach. On the other hand, the small but significant overestimation of EVLWI by a mean of 0.83mL/kg in the above-mentioned study [24] suggests that mathematical underestimation of EVLW might be over-compensated by some kind of indicator-loss due the enlarged thermodilution volume in case of femoral indicator injection.
Finally, based on the data of this study some of these considerations seem to be theoretical, since pragmatic correction of PVPI by the previously suggested correction formula for femoral indicator injection derived GEDVI resulted in a low bias and an appropriate categorization according to clinically relevant thresholds.
6.) Is GEF appropriately corrected?
Our data indicate that GEF derived from femoral indicator injection is appropriately corrected by the new PiCCO-2 algorithm. In addition to a low bias for GEF_fem_cor vs. GEF_jug, the percentage error was acceptable with 26.3%. This also applies to the comparison of femoral measurements with and without correction by the device (GEF_fem_cor vs. GEF_fem_uncor) with a percentage error of 27.0%.
Practical implications
Since recent data did not indicate an increased risk of catheter-related bloodstream infections in case of a femoral catheter site, and due to the “ease and perceived lower insertion risk at this site” [31], the femoral venous access remains to be frequently chosen catheter site used in up to a third of CVCs [32,33]. The percentage might be even higher in severely ill patients requiring central venous access for different purposes including extracorporeal organ support [28].
According to this study GEF is appropriately corrected in case of femoral indicator injection and can be used with the same normal ranges as for jugular or subclavian indicator injection.
However, PVPI remains to be uncorrected for femoral vein indicator injection, resulting in a substantial and clinical relevant underestimation of PVPI. This might lead to a substantial number of measurements misclassifying PVPI-values as “hydrostatic oedema” instead of “inflammatory pulmonary oedema”. Appropriate correction of PVPI is of high clinical importance, since PVPI cannot be replaced by other techniques, while echocardiographic ejection fraction gives an information which is comparable to GEF. Consistent correction for femoral indicator injection derived GEDVI, PVPI and GEF is of high practical relevance and would avoid the introduction of separate “normal” ranges for PVPI in case of femoral indicator injection.
As long as consistent correction for GEDVI and PVPI is not given by the PiCCO-algorithm, the clinician can re-calculate PVPI_fem_cor_calc based EVLWI_fem_cor and GEDVI_fem_cor. A previous study demonstrated that not only GEDVI_fem_cor, but also GEDV_fem_cor are corrected in case of the correct information about the femoral indicator injection [27]. Therefore, the clinician can use unindexed values of GEDV_fem_cor and EVLW_fem_uncor as displayed by the device to calculate PVPI_fem_cor_calc. This facilitates the calculation of PVPI_fem_cor_calc, since recalculation of EVLW and GEDV from EVLWI and GEDVI can be avoided.
Fig 2 summarizes the present knowledge about correction for femoral CVC indicator injection derived TPTD in the latest PiCCO-algorithm [24–27]: The primarily measured GEDV_fem_uncor is indexed to predicted body surface area (BSA) resulting in GEDVI_fem_uncor. In a next step GEDVI_fem_cor is derived from the correction of GEDVI_fem_uncor according to the previously suggested formula. Unindexed GEDV_fem_cor results from multiplication of GEDVI_fem_cor by predicted BSA, and it is used for calculation of GEF_fem_cor. By contrast, PVPI_fem is based on GEDV_fem_uncor irrespective of giving the information about the femoral CVC-position. While the last PiCCO-algorithm at least corrects GEDVI_fem and GEF_fem, to the best of our knowledge the EV-1000 does not correct any parameter derived from femoral CVC indicator injection (Fig 3; [5]).
[Figure omitted. See PDF.]
Fig 2. Algorithm for the calculation of GEDV, GEDVI, PBV, PVPI and GEF as displayed by the PiCCO-2 software V 3.1.
Confounders (volume of VCI) and confounded values with marked deviation from corresponding measurements using jugular access (PBV, PVPI_fem) are shaded. The primarily measured GEDVfem_uncor is indexed to predicted body surface area (BSA) resulting in GEDVI_fem_uncor. In a next step GEDVI_fem_cor is derived from correction of GEDVI_fem_uncor according to the previously suggested formula. Unindexed GEDV_fem_cor results from multiplication of GEDVI_fem_cor by predicted BSA and is used for calculation of GEF_fem_cor. By contrast, PVPI_fem is based on GEDV_fem_uncor irrespective of giving the information about the femoral CVC-position.
GEDV(I): global end-diastolic volume (index)
PBV: pulmonary blood volume
PVPI: pulmonary vascular permeability index
GEF: global ejection fraction
BSA: body surface area
https://doi.org/10.1371/journal.pone.0178372.g002
[Figure omitted. See PDF.]
Fig 3. Algorithm assumed for the calculation of GEDV, GEDVI, PBV, PVPI and GEF as displayed by the EV-1000 [5].
Confounders (volume of VCI) and confounded values with marked deviation deviation from corresponding measurements using jugular access (PBV, PVPI_fem) are shaded. The EV-1000 does not correct any parameter derived from femoral CVC indicator injection.
GEDV(I): global end-diastolic volume (index)
PBV: pulmonary blood volume
PVPI: pulmonary vascular permeability index
GEF: global ejection fraction
https://doi.org/10.1371/journal.pone.0178372.g003
Limitations of the study
This study is a single centre study including patients from a general ICU with predominantly medical patients. With a total of 54 measurements performed in 25 patients the number of measurements per patient ranged from 1 to 4 (mean 2.2). Nevertheless, the results derived from the totality of measurements were confirmed by the analyses of the first measurement in each patient. However, larger and multi-centric trials are still required to improve the correction formula suggested for GEDVI derived from 24 patients [24] and to establish a consistent calculation of all TPTD-derived parameters.
Conclusions
Femoral indicator injection for TPTD results in significantly lower values for PVPI and GEF. While the last PiCCO algorithm appropriately corrects for GEF, this correction obviously is not applied to PVPI. Therefore, GEF-values can be used in case of femoral CVC, but PVPI-values are substantially underestimated. Application of the correction for femoral CVC should be also applied to PVPI.
Supporting information
[Figure omitted. See PDF.]
S1 Fig. Boxplots plots comparing pulmonary vascular permeability index PVPI derived from jugular indicator injection (PVPI_jug), from femoral injection without activating a potential correction by the device (PVPI_fem_uncor), from femoral injection with activating a potential correction by the device (PVPI_fem_cor) and from femoral injection without activating a potential correction by the device, but correcting by the previously suggested formula (PVPI_fem_uncor_form).
PVPI_fem_uncor_form was corrected using the formula suggested for correction of femoral indicator injection derived GEDVI: GEDVIcorrected [mL / m2] = 0.539 * GEDVIuncorrected—15.17 + 24.49 * CIuncorrected 2.311* BWideal. PVPI_fem_uncor_form was calculated by multiplying PVPI_fem_uncor with the ratio 0.25*GEDVuncorrected/0.25*GEDVcorrected.
https://doi.org/10.1371/journal.pone.0178372.s001
(TIF)
S2 Fig. Boxplots plots comparing global ejection fraction derived from jugular indicator injection (GEF_jug), from femoral injection without activating a potential correction by the device (GEF_fem_uncor) and from femoral injection with activating a potential correction by the device (GEF_fem_cor).
https://doi.org/10.1371/journal.pone.0178372.s002
(TIF)
Citation: Huber W, Gruber A, Eckmann M, Elkmann F, Klein I, Lahmer T, et al. (2017) Comparison of pulmonary vascular permeability index PVPI and global ejection fraction GEF derived from jugular and femoral indicator injection using the PiCCO-2 device: A prospective observational study. PLoS ONE12(10): e0178372. https://doi.org/10.1371/journal.pone.0178372
1. Sakka SG, Klein M, Reinhart K, Meier-Hellmann A (2002) Prognostic value of extravascular lung water in critically ill patients. Chest 122: 2080–2086. pmid:12475851
2. Biancofiore G, Critchley LA, Lee A, Bindi L, Bisa M, Esposito M, et al. (2009) Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth 102: 47–54. pmid:19059920
3. Salzwedel C, Puig J, Carstens A, Bein B, Molnar Z, Kiss K, et al. (2013) Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study. Crit Care 17: R191. pmid:24010849
4. Huber W, Umgelter A, Reindl W, Franzen M, Schmidt C, von Delius S, et al. (2008) Volume assessment in patients with necrotizing pancreatitis: a comparison of intrathoracic blood volume index, central venous pressure, and hematocrit, and their correlation to cardiac index and extravascular lung water index. Crit Care Med 36: 2348–2354. pmid:18596637
5. Huber W, Phillip V, Hollthaler J, Schultheiss C, Saugel B, Schmid RM (2016) Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView((R)): do the same criteria apply as for the PiCCO((R))? J Zhejiang Univ Sci B 17: 561–567. pmid:27381733
6. Jonas MM, Tanser SJ (2002) Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output. Curr Opin Crit Care 8: 257–261. pmid:12386506
7. Huber W, Hollthaler J, Schuster T, Umgelter A, Franzen M, Saugel B, et al. (2014) Association between different indexations of extravascular lung water (EVLW) and PaO2/FiO2: a two-center study in 231 patients. PLoS One 9: e103854. pmid:25093821
8. Cordemans C, De Laet I, Van Regenmortel N, Schoonheydt K, Dits H, Huber W, et al. (2012) Fluid management in critically ill patients: the role of extravascular lung water, abdominal hypertension, capillary leak, and fluid balance. Ann Intensive Care 2: S1. pmid:22873410
9. Tagami T, Kushimoto S, Yamamoto Y, Atsumi T, Tosa R, Matsuda K, et al. (2010) Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study. Crit Care 14: R162. pmid:20819213
10. Chew MS, Ihrman L, During J, Bergenzaun L, Ersson A, Unden J, et al. (2012) Extravascular lung water index improves the diagnostic accuracy of lung injury in patients with shock. Crit Care 16: R1. pmid:22214612
11. Mallat J, Pepy F, Lemyze M, Barrailler S, Gasan G, Tronchon L, et al. (2012) Extravascular lung water indexed or not to predicted body weight is a predictor of mortality in septic shock patients. J Crit Care 27: 376–383. pmid:22591571
12. Goepfert MS, Richter HP, Zu Eulenburg C, Gruetzmacher J, Rafflenbeul E, Roeher K, et al. (2013) Individually optimized hemodynamic therapy reduces complications and length of stay in the intensive care unit: a prospective, randomized controlled trial. Anesthesiology 119: 824–836. pmid:23732173
13. Huber W, Mair S, Gotz SQ, Tschirdewahn J, Frank J, Hollthaler J, et al. (2016) A systematic database-derived approach to improve indexation of transpulmonary thermodilution-derived global end-diastolic volume. J Clin Monit Comput.
14. Sun Y, Lu ZH, Zhang XS, Geng XP, Cao LJ, Yin L (2015) The effects of fluid resuscitation according to PiCCO on the early stage of severe acute pancreatitis. Pancreatology 15: 497–502. pmid:26160657
15. Groeneveld AB, Verheij J (2006) Extravascular lung water to blood volume ratios as measures of permeability in sepsis-induced ALI/ARDS. Intensive Care Med 32: 1315–1321. pmid:16741694
16. Combes A, Berneau JB, Luyt CE, Trouillet JL (2004) Estimation of left ventricular systolic function by single transpulmonary thermodilution. Intensive Care Med 30: 1377–1383. pmid:15105983
17. Belda FJ, Aguilar G, Jover JL, Ferrando C, Postigo S, Aznarez B (2010) [Clinical validation of minimally invasive evaluation of systolic function]. Rev Esp Anestesiol Reanim 57: 559–564. pmid:21155336
18. Monnet X, Anguel N, Osman D, Hamzaoui O, Richard C, Teboul JL (2007) Assessing pulmonary permeability by transpulmonary thermodilution allows differentiation of hydrostatic pulmonary edema from ALI/ARDS. Intensive Care Med 33: 448–453. pmid:17221189
19. Kor DJ, Warner DO, Carter RE, Meade LA, Wilson GA, Li M, et al. (2015) Extravascular lung water and pulmonary vascular permeability index as markers predictive of postoperative acute respiratory distress syndrome: a prospective cohort investigation. Crit Care Med 43: 665–673. pmid:25513786
20. Garutti I, Sanz J, Olmedilla L, Tranche I, Vilchez A, Fernandez-Quero L, et al. (2015) Extravascular Lung Water and Pulmonary Vascular Permeability Index Measured at the End of Surgery Are Independent Predictors of Prolonged Mechanical Ventilation in Patients Undergoing Liver Transplantation. Anesth Analg 121: 736–745. pmid:26218864
21. Johansson J, Steinvall I, Herwald H, Lindbom L, Sjoberg F (2015) Alteration of Leukocyte Count Correlates With Increased Pulmonary Vascular Permeability and Decreased PaO2:FiO2 Ratio Early After Major Burns. J Burn Care Res 36: 484–492. pmid:25501784
22. Kushimoto S, Taira Y, Kitazawa Y, Okuchi K, Sakamoto T, Ishikura H, et al. (2012) The clinical usefulness of extravascular lung water and pulmonary vascular permeability index to diagnose and characterize pulmonary edema: a prospective multicenter study on the quantitative differential diagnostic definition for acute lung injury/acute respiratory distress syndrome. Crit Care 16: R232. pmid:23232188
23. Malbrain ML, De Potter TJ, Dits H, Reuter DA (2010) Global and right ventricular end-diastolic volumes correlate better with preload after correction for ejection fraction. Acta Anaesthesiol Scand 54: 622–631. pmid:20085545
24. Saugel B, Umgelter A, Schuster T, Phillip V, Schmid RM, Huber W (2010) Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter. Crit Care 14: R95. pmid:20500825
25. Schmidt S, Westhoff TH, Hofmann C, Schaefer JH, Zidek W, Compton F, et al. (2007) Effect of the venous catheter site on transpulmonary thermodilution measurement variables. Crit Care Med 35: 783–786. pmid:17255873
26. Berbara H, Mair S, Beitz A, Henschel B, Schmid RM, Huber W (2014) Pulmonary vascular permeability index and global end-diastolic volume: are the data consistent in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study. BMC Anesthesiol 14: 81. pmid:25928560
27. Beitz A, Berbara H, Mair S, Henschel B, Lahmer T, Rasch S, et al. (2016) Consistency of cardiac function index and global ejection fraction with global end-diastolic volume in patients with femoral central venous access for transpulmonary thermodilution: a prospective observational study. J Clin Monit Comput.
28. Huber W, Fuchs S, Minning A, Kuchle C, Braun M, Beitz A, et al. (2016) Transpulmonary thermodilution (TPTD) before, during and after Sustained Low Efficiency Dialysis (SLED). A Prospective Study on Feasibility of TPTD and Prediction of Successful Fluid Removal. PLoS One 11: e0153430. pmid:27088612
29. Hofkens PJ, Verrijcken A, Merveille K, Neirynck S, Van Regenmortel N, De Laet I, et al. (2015) Common pitfalls and tips and tricks to get the most out of your transpulmonary thermodilution device: results of a survey and state-of-the-art review. Anaesthesiol Intensive Ther 47: 89–116. pmid:25421923
30. Yu WQ, Zhang Y, Zhang SY, Liang ZY, Fu SQ, Xu J, et al. (2016) Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables. J Zhejiang Univ Sci B 17: 60–66. pmid:26739527
31. Marik PE, Flemmer M, Harrison W (2012) The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: a systematic review of the literature and meta-analysis. Crit Care Med 40: 2479–2485. pmid:22809915
32. Gowardman JR, Robertson IK, Parkes S, Rickard CM (2008) Influence of insertion site on central venous catheter colonization and bloodstream infection rates. Intensive Care Med 34: 1038–1045. pmid:18317732
33. Deshpande KS, Hatem C, Ulrich HL, Currie BP, Aldrich TK, Bryan-Brown CW, et al. (2005) The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population. Crit Care Med 33: 13–20; discussion 234–235. pmid:15644643
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2017 Huber et al. This is an open access article distributed under the terms of the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Background
Transpulmonary thermodilution (TPTD) is used to derive cardiac output CO, global end-diastolic volume GEDV and extravascular lung water EVLW. To facilitate interpretation of these data, several ratios have been developed, including pulmonary vascular permeability index (defined as EVLW/(0.25*GEDV)) and global ejection fraction ((4*stroke volume)/GEDV). PVPI and GEF have been associated to the aetiology of pulmonary oedema and systolic cardiac function, respectively. Several studies demonstrated that the use of femoral venous access results in a marked overestimation of GEDV. This also falsely reduces PVPI and GEF. One of these studies suggested a correction formula for femoral venous access that markedly reduced the bias for GEDV. Consequently, the last PiCCO-algorithm requires information about the CVC, and correction for femoral access has been shown. However, two recent studies demonstrated inconsistencies of the last PiCCO algorithm using incorrected GEDV for PVPI, but corrected GEDV for GEF. Nevertheless, these studies were based on mathematical analyses of data displayed in a total of 15 patients equipped with only a femoral, but not with a jugular CVC.
Therefore, this study compared PVPI_fem and GEF_fem derived from femoral TPTD to values derived from jugular indicator injection in 25 patients with both jugular and femoral CVCs.
Methods
54 datasets in 25 patients were recorded. Each dataset consisted of three triplicate TPTDs using the jugular venous access as the gold standard and the femoral access with (PVPI_fem_cor) and without (PVPI_fem_uncor) information about the femoral indicator injection to evaluate, if correction for femoral GEDV pertains to PVPI_fem and GEF_fem.
Results
PVPI_fem_uncor was significantly lower than PVPI_jug (1.48±0.47 vs. 1.84±0.53; p<0.001). Similarly, PVPI_fem_cor was significantly lower than PVPI_jug (1.49±0.46 vs. 1.84±0.53; p<0.001). This is explained by the finding that PVPI_fem_uncor was not different to PVPI_fem_cor (1.48±0.47 vs. 1.49±0.46; n.s.). This clearly suggests that correction for femoral CVC does not pertain to PVPI.
GEF_fem_uncor was significantly lower than GEF_jug (20.6±5.1% vs. 25.0±6.1%; p<0.001). By contrast, GEF_fem_cor was not different to GEF_jug (25.6±5.8% vs. 25.0±6.1%; n.s.). Furthermore, GEF_fem_cor was significantly higher than GEF_fem_uncor (25.6±5.8% vs. 20.6±5.1%; p<0.001). This finding emphasizes that an appropriate correction for femoral CVC is applied to GEF_fem_cor.
The extent of the correction (25.5/20.6; 124%) for GEF and the relation of PVPI_jug/PVPI_fem_uncor (1.84/1.48; 124%) are in the same range as the ratio of GEDVI_fem_uncor/GEDVI_fem_cor (1056ml/m2/821mL/m2; 129%). This further emphasizes that GEF, but not PVPI is corrected in case of femoral indicator injection.
Conclusions
Femoral indicator injection for TPTD results in significantly lower values for PVPI and GEF. While the last PiCCO algorithm appropriately corrects GEF, the correction is not applied to PVPI. Therefore, GEF-values can be used in case of femoral CVC, but PVPI-values are substantially underestimated.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer