Full Text

Turn on search term navigation

© 2017 Wilke et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Early diagnosis of myocardial infarction (MI) with cardiac troponin (cTn) assays at the point-of-care (POC) is suggested to shorten turn-around-time in the emergency department (ED). The present study aimed at comparing the diagnostic performance of two POC cTn assays with that of a central laboratory high-sensitivity (hs) method, under routine ED conditions. In 2,163 non-selected ED patients suspected for MI, the diagnostic performance of the POC troponin I (TnI), troponin T (TnT), and hs-TnT assay for the prediction of MI was evaluated based on receiver operating characteristic (ROC) analyses and compared with the performance based on the manufacturers’ cut-offs. Due to an observed association between renal function as determined by estimated glomerular filtration rate (eGFR) and cTn concentrations, all analyses were stratified by renal function. In patients with normal renal function (eGFR > 60 mL/min/1.73m2), POC and hs assays showed a comparable diagnostic performance as quantified by the area under the ROC curve (AUC) of about 0.88. The ROC-derived optimal cut-off (OCO) levels for the different cTn assays clearly changed with decreasing kidney function. Impaired kidney function required OCO to be three to five times higher to achieve a comparable performance. Particularly cTnT concentrations were strongly associated with renal function. The three cTn assays demonstrated equivalent diagnostic performance in ED-patients admitted with suspected ACS in relation to the release diagnosis, supporting the use of POC testing in this setting. The present results implicate that application of eGFR-specific OCOs may decrease false-positives among patients with impaired renal function. Providing individual cut-offs depending on patients’ eGFR might be an appropriate add-on tool to improve specificity in the diagnosis of MI.

Details

Title
Diagnostic performance of point-of-care and central laboratory cardiac troponin assays in an emergency department
Author
Wilke, Petra; Masuch, Annette; Fahron, Oliver; Zylla, Stephanie; Leipold, Tobias; Petersmann, Astrid
First page
e0188706
Section
Research Article
Publication year
2017
Publication date
Nov 2017
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1969919002
Copyright
© 2017 Wilke et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.