Full Text

Turn on search term navigation

© 2017 Truong et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Aims

To investigate the right ventricular (RV) strain in pectus excavatum (PE) patients using cardiac magnetic resonance tissue tracking (CMR TT).

Materials and methods

Fifty consecutive pectus excavatum patients, 10 to 32 years of age (mean age 15 ± 4 years), underwent routine cardiac magnetic resonance imaging (CMR) including standard measures of chest geometry and cardiac size and function. The control group consisted of 20 healthy patients with a mean age of 17 ± 5 years. RV longitudinal and circumferential strain magnitude was assessed by a dedicated RV tissue tracking software.

Results

Fifty patients with images of sufficient quality were included in the analysis. The mean right and left ventricular ejection fractions were 55 ± 5% and 59 ± 4%. The RV global longitudinal strain was -21.88 ± 4.63%. The RV circumferential strain at base, mid-cavity and apex were -13.66 ± 3.09%, -11.31 ± 2.79%, -20.73 ± 3.45%, respectively. There was no statistically significant decrease in right ventricular or left ventricular ejection fraction between patients and controls (p > 0.05 for each). There was no significant difference in RV global longitudinal strain between two groups (-21.88 ± 4.63 versus -21.99 ± 3.58; p = 0.93). However, there was significant decrease in mid-cavity circumferential strain magnitude in pectus patients compared with controls (-11.31 ± 2.79 versus -16.19 ± 2.86; p < 0.001). PE patients had a significantly higher basal circumferential strain (-13.66 ± 3.09% versus -9.76 ± 1.79; p < 0.001) as well as apical circumferential strain (-20.73 ± 3.45% versus -12.07 ± 3.38) than control group.

Conclusion

Mid-cavity circumferential strain but not longitudinal strain is reduced in pectus excavatum patients. Basal circumferential strain as well as apical circumferential strain were increased as compensatory mechanism for reduced mid-cavity circumferential strain. Further studies are needed to establish clinical significance of this finding.

Details

Title
Occult RV systolic dysfunction detected by CMR derived RV circumferential strain in patients with pectus excavatum
Author
Truong, Vien T; Li, Candice Y; Brown, Rebeccah L; Moore, Ryan A; Garcia, Victor F; Crotty, Eric J; Taylor, Michael D; Ngo, Tam M N; Mazur, Wojciech
First page
e0189128
Section
Research Article
Publication year
2017
Publication date
Dec 2017
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1975587022
Copyright
© 2017 Truong et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.