It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
The two-compartment intravoxel incoherent motion (IVIM) theory assumes that the transverse relaxation time is the same in both compartments. However, blood and tissue have different T2 values, and echo time (TE) may thus have an effect on the quantitative parameters of IVIM. The purpose of this study was to investigate the effects of TE on IVIM-DWI-derived parameters of the prostate. In total, 17 healthy volunteers underwent two repeat examinations. IVIM-DWI data were scanned 6 times with variable TE values of 60, 70, 80, 90, 100, and 120 ms. The ADC of a mono-exponential model and the D, D*, and f parameters of the IVIM model were calculated separately for each TE. Repeat measures were assessed by calculating the coefficient of variation and Bland-Altman limits of agreement for each parameter. Spearman’s rho test was used to analyse relationships between IVIM indices and TE. Our results showed that TE had an effect on IVIM quantification, which should be kept constant in the examination protocol at each individual institution. Alternatively, an extended IVIM could be used to eliminate the effect of the TE value on the quantitative parameters of IVIM. This may be helpful for guiding clinical research, especially for longitudinal studies.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
2 MR Collaboration NE Asia, Siemens Healthcare, Shanghai, China