Abstract

Background

The purpose of this study was to compare two methods of stabilization for proximal tibia fractures (AO 41) with a complete metaphyseal component, external fixation with the Ilizarov wire frame, and internal fixation with locking plates.

Methods

Patients from two level 1 trauma centers treated between 2009 and 2015 were included in a retrospective comparing cohort study. The first center stabilized the non-pathological, proximal tibia fractures exclusively with external fixation and the second with internal plating. Combined clinically and radiologically evaluated, bone healing was the primary outcome. The secondary outcomes included complications, range of motion (ROM) and axial alignment of the knee, the reoperation rate within 6 months, heterotopic ossifications (HTO), and signs of posttraumatic osteoarthritis (PTOA). A logistic regression analysis corrected for uneven distributed parameters.

Results

The 62 patients treated with Ilizarov frame and the 68 patients treated with plate fixation were comparable regarding epidemiological parameters, injury characteristics, and comorbidity except for injury severity score (ISS) and smoking behavior. The time of healing was shorter in the group undergoing plate fixation (p = 0.041); however, the incidence of non-unions was equal. Furthermore, there was no difference regarding the rate of deep infections, thrombosis, alignment, reoperations, PTOA, and ROM. Heterotopic ossifications were more prevalent following plate fixation (13.2 vs 1.6%, p = .013). External fixation was associated with a higher rate of superficial infections (40.4 vs 2.9%, p = .000). The initial displacement, the incidence of deep infections, and the classification significantly influenced the incidence of non-unions in both groups (p < 0.02).

Conclusions

Fixation of proximal tibia fractures with plates resulted in a slightly shorter healing time compared to Ilizarov frame stabilization. Furthermore, the complication profiles differ with more heterotopic ossifications and less superficial infections following internal plating.

Trial registration

DRKS, DRKS00013275, Registered 11/2/2017, Retrospectively registered.

Details

Title
Comparing case-control study for treatment of proximal tibia fractures with a complete metaphyseal component in two centers with different distinct strategies: fixation with Ilizarov frame or locking plates
Author
Berven, Haakon; Brix, Michael; Izadpanah, Kaywan; Kubosch, Eva Johanna; Schmal, Hagen
Publication year
2018
Publication date
2018
Publisher
BioMed Central
e-ISSN
1749-799X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2056872533
Copyright
Copyright © 2018. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and conditions, you may use this content in accordance with the terms of the License.