About the Authors:
Lukas Clasen
Contributed equally to this work with: Lukas Clasen, Christian Eickholt
Roles Investigation, Writing – original draft
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
Christian Eickholt
Contributed equally to this work with: Lukas Clasen, Christian Eickholt
Roles Writing – original draft
Current address: Department of Electrophysiology, University Heart Centre, University Hospital, Hamburg, Eppendorf, Germany
Affiliation: Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
ORCID logo http://orcid.org/0000-0002-5458-9688
Stephan Angendohr
Roles Methodology, Writing – review & editing
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
Christiane Jungen
Roles Methodology, Writing – review & editing
Current address: Department of Electrophysiology, University Heart Centre, University Hospital, Hamburg, Eppendorf, Germany
Affiliation: Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
Dong-In Shin
Roles Conceptualization, Supervision
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
Birgit Donner
Roles Conceptualization, Methodology
Current address: Department of Paediatric Cardiology, University-Children’s-Hospital, Basel, Switzerland
Affiliation: Department of Pediatric Cardiology and Pneumology, University Children's Hospital, Duesseldorf, Germany
Alexander Fürnkranz
Roles Writing – review & editing
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
Malte Kelm
Roles Conceptualization, Funding acquisition, Writing – review & editing
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
Nikolaj Klöcker
Roles Conceptualization, Funding acquisition, Methodology, Project administration, Writing – review & editing
Affiliation: Institute of Neuro- and Sensory Physiology, Medical Faculty, Heinrich-Heine-University, Duesseldorf, Germany
Christian Meyer
Roles Conceptualization, Methodology, Writing – review & editing
* E-mail: [email protected] (HM); [email protected] (CM)
Current address: Department of Electrophysiology, University Heart Centre, University Hospital, Hamburg, Eppendorf, Germany
Affiliation: Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
Hisaki Makimoto
Roles Conceptualization, Formal analysis, Investigation, Methodology, Project administration, Supervision, Validation, Visualization, Writing – review & editing
* E-mail: [email protected] (HM); [email protected] (CM)
Affiliations Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany, Cardiovascular Research Institute Duesseldorf (CARID), University Duesseldorf, Medical Faculty, Duesseldorf, Germany
ORCID logo http://orcid.org/0000-0002-5302-2874
Introduction
Mice present the prevailing model organism in basic cardiovascular research. They play a key role in the translation of molecular and cellular mechanisms into the in-vivo setting [1]. This is of increasing relevance in the ongoing exploration of cardiac arrhythmia mechanisms and the quest for more effective antiarrhythmic treatment options [2].
There is consensus on the definition of murine arrhythmias summarized in the revised Lambeth Convention [3]. The idea of employing a scoring system for ventricular arrhythmias (VA) was developed first in 1988 and was recently taken up again [4–6]. It could serve as a reference for interpreting electrophysiological findings in murine models of diseases.
However, murine vulnerability for VA has been discussed ambiguously, especially in comparison to humans. The long-term accepted critical mass theory presented by Garrey [7] has been questioned in this context, as sustained VA could be shown in <1 cm2 tissue areas [8]. In the current literature, inducibility of VA in C57BL/6 wildtype mice is mostly limited to short runs of VA when using classical programmed electrical stimulation (PES) protocols.
It is well known that the majority of VA results from triggered activity or re-entry [9, 10]. Arrhythmias by re-entrant mechanisms may well be induced by a critical delay in the re-entrant circuit by a greater number of extrastimuli [10]. Arrhythmias by triggered activity, particularly delayed afterdepolarization, are efficiently induced by Ca2+-overload by a greater number of extrastimuli [11–13]. Therefore, we herein hypothesized that the inducibility of VA in wildtype mice is facilitated by increasing the number of ventricular extrastimuli in PES.
Our findings in the present study suggest that a modified approach of PES in mice is useful to efficiently document and evaluate acutely induced VA.
Materials and methods
Systematic literature review
A systematic literature research of the PubMed database was conducted using the search terms: “in vivo cardiac electrophysiology AND mouse”, “intracardiac electrophysiology AND mouse”, “mouse electrophysiology AND ventricular arrhythmia”, “in vivo ventricular arrhythmia AND mouse” and “programmed electrical stimulation AND mouse”, for the period from 1 January 1996 until 1 January 2017. In an attempt to access the grey literature, we searched the OpenGrey Database (http://www.opengrey.eu). Only in vivo electrophysiological study (EPS) with jugular transvenous approach and ventricular programmed stimulation were considered. We excluded references with VA induction solely by ventricular burst-stimulation and not published in English unless an English version of the abstract was accessible.
Animal care
Animal care, all experiments and euthanasia were conducted adhering to established guidelines [14] and with the prospective approval of the North Rhine-Westphalian State Agency for Nature, Environment and Consumer Protection (LANUV, permit number: G460/13). In this study male wildtype mice C57BL/6J (n = 12; 14–16 weeks; 25.5 ± 2.5g) were held on standard chow and tap water ad libitum, under a 12/12 hours light/dark cycle [15]. All experiments were conducted under mild sedation with isoflurane 1.6 Vol.% (induction period 2.5 Vol.% in 70% N2O / 30% O2), monitored by hind limb reflex and controlled by spontaneous breathing rate. Body core temperature was strictly maintained continously at 36°C via a rectal probe (T-type Pod ML312; Rectal Probe for Mice RET-3, ADInstruments) (S1 Fig, S1 Text). Duration of experiments was limited to 90 minutes to avoid sedation overload [16]. Euthanasia was conducted at the end of the study by exsanguination after deep anesthesia with intraperitoneal administration of 100mg/kg body-weight ketamine and 10mg/kg body-weight xylazine.
Cardiac function was assured in a subgroup of tested mice by cardiac echocardiography (S1 Table, S2 Text).
Electrophysiological study and ventricular PES
Surface ECG was obtained in Einthoven lead I using clamp electrodes (ECG amplifier, Hugo Sachs) connected to a PowerLab 8/30 (ADInstruments). Endocardial EPS was conducted using a 2.0 F (0.67mm) octapolar electrophysiology catheter (0.5mm electrode spacing; CIBer Mouse, NuMed) as described earlier [17, 18]. The catheter was positioned into the right ventricle via the right jugular vein under electrocardiographic monitoring. Electrodes 1–4 sensed ventricular activity, electrodes 5–6 recorded near the His region and electrodes 7–8 detected atrial activity. Data was analyzed with the LabChart 7.3.7 software suite (ADInstruments). Measurements comprised heart rate (HR, bpm), cycle length (CL, ms), P-wave duration (ms), PR interval (ms), QRS interval (ms) and rate corrected QT interval (ms) [19].
Ventricular stimulation was achieved by rectangular impulses of 1 ms delivered at twice the pacing threshold voltage. Ventricular refractory period (VRP) was obtained by S1S2 stimulation with trains of 8 S1-stimuli (CL 100ms, 90ms, 80ms) and decremental coupling of S2 intervals (initial coupling interval 60ms, 2ms decrement) [18]. To induce two protocols were used, based on the literature review (S2 Fig):
1. Modified burst-stimulation protocol (miniburst, MB): Three to ten (S2S3S4—S11) extrastimuli after a train of twenty S1-stimuli (CL 100ms). Extrastimuli were coupled at an interval from 60 to 20ms with 2ms decrements (Fig 1B and 1C).
2. Conventional PES protocol: Two (S2S3) and three (S2S3S4) extrastimuli (initial coupling interval 60ms, 2ms decrement) after a train of eight S1-stimuli (CL 100ms) [17, 18]. When coupling two extrastimuli the first extrastimulus was delivered at 20ms above the refractory period and the second extrastimulus was coupled at an interval from 60 to 20ms with 2ms decrements. When coupling three extrastimuli the first and second extrastimuli were delivered at 20ms above the refractory period and the third extrastimulus was coupled at an interval from 60 to 20ms with 2ms decrements. (Fig 1A).
[Figure omitted. See PDF.]
Fig 1. Examples of conventional and modified protocols to investigate the inducibility of ventricular arrhythmias by programmed electrical stimulation.
A: Conventional programmed electrical stimulation (PES) protocol, which consists of eight S1 stimuli followed by two (S3) to three (S4) extrastimuli that are coupled in decrements of 2ms intervals from 60ms to 20ms. B: A representative example of the modified extrastimulation protocol depicts twenty S1 stimuli followed by three (S2-S4) extrastimuli. This protocol was defined as “miniburst (MB)”. C: The miniburst protocol with ten (S2-S11) extrastimuli. (for details see text).
https://doi.org/10.1371/journal.pone.0201910.g001
Decremental pacing until 20ms was performed in order to ensure passing the refractory period. There was a period of recreation in sinus rhythm allowed for at least 2s between each pacing step. The 2 second-interval between each stimulation episode was adopted from the human electrophysiological test, because our literature review revealed that data on Ca2+ decay after stimulation episodes in mice were scarce [13, 20].
To assess individual VA inducibility after sympathetic activation each protocol was repeated with isoprenaline (1μg/g i.p.), resulting in an HR increase of at least 10% of baseline HR [18]. Direct progression to S11-stimulation was conducted during the MB protocol without MB S4 –S10, to avoid a prolonged study. All mice received exactly the same protocol.
Arrhythmia assessment
VA induced during EPS were analyzed according to international consensus [3], using two established arrhythmia scores (Faggioni et al = score 1; van der Werf et al = score 2) [5, 21]. The score by Faggioni et al. bases on the worst ventricular arrhythmia displayed: 0 for no ventricular premature beats (VPBs) or isolated VPBs; 1 for frequent/bigeminal VPBs; 2 for couplets; and 3 for ventricular tachycardia. The arrhythmia score by Van der Werf et al is defined by the worst ventricular arrhythmia: 1 = no or isolated VPBs, 2 = bigeminal VPBs and/or frequent VPBs (>10 per minute), 3 = couplet, 4 = non-sustained VT (NSVT; ≥3 successive VPBs). Additionally, a novel arrhythmia score (score 3) was developed, differentiating VA by duration by assigning increasing score values (Fig 2): single premature ventricular complex (PVC) (1 point), couplet (3 points), triplet (4 points) and ventricular tachycardia (VT) (≥4 ventricular complexes = 5 points, ≧1s = 6 points) (Table 1).
[Figure omitted. See PDF.]
Fig 2. Systematic classification of ventricular arrhythmias based on the Lambeth criteria.
Four types of ventricular arrhythmias are defined by international guidelines (11). A single premature ventricular complex (A), a ventricular couplet (B), triplet (C) and a ventricular tachycardia (D). Vertical arrow heads assign each premature ventricular complex. The horizontal square brackets depict programmed electrical stimulation. Surface electrocardiogram Einthoven lead I, intracardiac bipolar electrogram from mid RV and stimulus output are displayed.
https://doi.org/10.1371/journal.pone.0201910.g002
[Figure omitted. See PDF.]
Table 1. Scoring systems of ventricular arrhythmias.
https://doi.org/10.1371/journal.pone.0201910.t001
Statistical analysis
Statistical analysis was performed with Prism for Windows (V6.0; Graph Pad Software). Data are shown as mean ± SEM. Nonparametric data were analyzed using the Kruskal-Wallis test with Dunn’s multiple comparison. Arrhythmia score data were analyzed using the Wilcoxon matched-pairs signed rank test. Comparison of arrhythmia scores were analyzed using the two-way ANOVA Tukey´s multi comparison test. Continuous variables were evaluated using unpaired t-test. P<0.05 was considered statistically significant.
Results
Systematic review of literature
The initial PubMed search yielded 659 results of which 42 met the predefined selection criteria (Table 2). Altogether, 435 mice of different genetic backgrounds were included (C57 n = 138, FVB n = 66, 129 n = 22, CD1 n = 6, C3H n = 5, mixed background n = 142, unspecified n = 56).
[Figure omitted. See PDF.]
Table 2. Results of systematic literature research concerning in vivo programmed ventricular stimulation in mice.
https://doi.org/10.1371/journal.pone.0201910.t002
The number of coupled extrastimuli during PES varied among studies. Double extrastimuli (S1S2-S3) were used in only seven studies. A majority of 29 studies performed double (S1S2-S3) and triple extrastimuli (S1S2-S4). Four studies coupled four extrastimuli (S1S2-S5), one coupled five extrastimuli (S1S2-S6), one coupled six extrastimuli (S1S2-S7) and one added up to ten extrastimuli (S1S2-S11) in case three extrastimuli did not yield VT.
In most studies, the definition of VA was different from the current guidelines (Lambeth convention), used in the present study, rendering a direct comparison of those studies unfeasible. Some studies counted only VTs >4 [22, 23], or >10 consecutive beats as VA [24] while others regarded single PVCs as VA [25]. Mean VA inducibility by PES was 4.6 ± 10.7% (20/435 mice, 10/42 studies), and varied with the number of extrastimuli: Two extrastimuli induced VA in 2.8% (2/71 mice, 1/7 studies) [26] and three extrastimuli induced VA in 2.5% (8/314 mice, 6/30 studies). Four to six extrastimuli induced VA in 12.2% (6/49 mice, 3/5 studies). Three to ten extrastimuli resulted in 55% VA induction (6/11 mice, 1 study) [27]. These results indicate a correlation between the number of extrastimuli and VA inducibility. Inducibility of VA was similar across all mouse strains tested (C57 6.5%, FVB 4.5%, 129 5.6% and mixed background 4.5%).
It was difficult to interpret the impact of isoprenaline on arrhythmia inducibility due to the differences in stimulation protocols and VA definitions. In 11 studies, the incidence of VA induction was 8.3% (8/96) after administration of isoprenaline as compared to 3.0% (3/100) under baseline conditions.
Electrophysiological study
The data recorded during the present study are presented in S1 Dataset. Electrophysiological properties recorded by surface and intracardiac ECG were in accordance with previously published data [28, 29]: QRS width was 10.4 ± 1.2 ms, QT was 57.1 ± 7.1 ms, and QTc was 50.7 ± 5.8 ms. VRP ranged from 32.2 ± 6.9 ms (S1 100ms) to 34.0 ± 7.5 ms (S1 80ms) at baseline. Baseline sinus CL was 112.5 ± 7.8 ms, decreasing to 100 ± 4.3 ms (quotient 12.4%, HR 535.7 ± 33.1 bpm to 601.3 ± 25.6 bpm p<0.0001) after isoprenaline administration (Table 3, S3 Fig).
[Figure omitted. See PDF.]
Table 3. Electrophysiological baseline characteristics.
https://doi.org/10.1371/journal.pone.0201910.t003
Under baseline conditions no VA induction was observed with the conventional PES protocol. Using the MB protocol, however, VA were induced in 50% of tested mice. Quantity and duration of VA increased with coupling of >6 extrastimuli (Two-way ANOVA, and Tukey’s multiple comparison as post-hoc analysis: MB S4 vs PES S2S3/S2S3S4 p = 0.909, MB S5 vs PES S2S3/S2S3S4 p = 0.312, MB S6 vs PES S2S3/S2S3S4 p = 0.105, MB S7 vs PES S2S3/S2S3S4 p = 0.054, S8 vs PES S2S3/S2S3S4 p = 0.011, MB S9 vs PES S2S3/S2S3S4 p = 0.025, MBS10 vs S2S3/S2S3S4 p = 0.312, MBS11 vs PES S2S3/S2S3S4 p = 0.0002) (Fig 3).
[Figure omitted. See PDF.]
Fig 3. Ventricular arrhythmia induction with the miniburst protocol.
Modified PES (MB) yielded VA in up to 50% of tested animals (n = 12). Inducibility increased when coupling of >6 extrastimuli (S4-S6 vs S7-S11 p = 0.011) (A). Predominantly, PVCs or VT of a duration less than 1 sec. were seen. PVC vs VT>1s p = 0.031, VT<1s vs VT>1s p = 0.030, Couplet vs VT>1s p = 0.096. Data plot as box and whiskers (B). Qualitative display of the number of extrastimuli in correlation with arrhythmia type. Quantity and duration of VA increased when coupling 7, 8 and 10 extrastimuli by means of ventricular events (MB S8 vs PES S2S3/S2S3S4 p = 0.011, MB S9 vs PES S2S3/S2S3S4 p = 0.025, MB S10 vs PES S2S3/S2S3S4 p = 0.312, MBS11 vs PES S2S3/S2S3S4 p = 0.0002). Stars represent animals affected (C).
https://doi.org/10.1371/journal.pone.0201910.g003
Under isoprenaline, VA were induced using both protocols; yet the increase of VA compared to baseline control was not significant (PES S2S3 baseline none vs 4 PVCs, 3 couplets, 1 triplets, 4 VTs<1s, 0 VT>1s in 4 mice after isoprenaline, arrhythmia score 3, p = 0.125; PES S2S3S4 baseline none vs 7 PVCs, 2 couplets, 0 triplet, 2 VTs<1s, 0 VT>1s in 5 mice after isoprenaline, arrhythmia score 3, p = 0.063; MB: baseline 9 PVCs, 4 couplets, 1 triplet, 5 VTs<1s, 0 VT>1s in 6 mice vs 9 PVCs, 5 couplets, 3 triplets, 10 VTs<1s, 0 VT>1s in 5 mice after isoprenaline, arrhythmia score 3, p = 0.281) (Fig 4).
[Figure omitted. See PDF.]
Fig 4. Impact of isoprenaline on ventricular arrhythmia induction.
PES in relation to inducibility of VA before and after isoprenaline injection (Baseline: MB S11 vs PES S3/S4 p = 0.031; Iso: S3 vs S11 p = 0.031, S4 vs S11 p = 0.063). Data plot as box and whiskers (A). Qualitative VA depiction of affected mice, only most severe ventricular event shown. Shown left results of conventional PES S2S3S4 (p = 0.063) and right MB S11 (p = 0.281). Green line indicates increase of VA. Thick line indicates ≥3 mice, thin line 2 mice, dotted line 1 mouse (B). Iso = isoprenaline, n = 12.
https://doi.org/10.1371/journal.pone.0201910.g004
Nonetheless, also under isoprenaline stimulation, the MB protocol was more effective in provoking VA compared to conventional PES protocols (MB S11 vs PES S2S3/S2S3S4, arrhythmia score 3 p = 0.031/p = 0.063) (Fig 4). Particularly, VT induction was more effective when comparing the MB protocol to the conventional PES protocol with three extrastimuli (MB S11 10 VT<1s in 5 mice vs PES S2S3 4 VT<1s in 2 mice p = 0.172, MB S11 vs PES S2S3S4 2 VT<1s in 2 mice p = 0.049). In addition to 2 mice in which VT<1s was inducible without Iso, VT<1s was inducible in 3 mice in which PVC, couplet and triplet were induced by MB protocol without Iso. This result indicates that the VA inducibility by the MB protocol without Iso may reflect arrhythmogenic properties mainly related to triggered activity in these mice. Thus, sensitivity of the MB protocol without Iso appears higher (PES 0% [0/5] vs MB 100% [6/6]) as compared to the PES protocol without Iso. Under baseline conditions, 6 mice without VA inducibility by MB did not show VA inducibility under Iso. This may indicate higher negative predictive value of baseline MB protocol (PES 58% [7/12] vs MB 100% [6/6]). In the present study, specificity of both baseline protocols was 100% (PES 7/7 vs MB 6/6).
Arrhythmia assessment
Cumulative events of recorded VA ranged from single PVCs (n = 38), couplets (n = 16), triplets (n = 10) to VTs <1s (n = 32) and VT >1s (n = 3). The number of animals with PVC and VT <1 s was 6 and 4, respectively (Fig 3B).
Application of the MB protocol induced VA already under baseline conditions. When applying arrhythmia score 1, MB extrastimulation resulted in 11 (S4), 17 (S5), 14 (S6), 27 (S7), (S8), 27 (S9), 20 (S10) and 26 (S11) cumulative score points. With arrhythmia score 2, MB extrastimulation resulted in 17 (S4), 27 (S5), 25 (S6), 40 (S7), 37 (S8), 41 (S9), 30 (S10) and 45 (S11) cumulative score points. According to arrhythmia score 3, MB extrastimulation resulted in 19 (S4), 31 (S5), 26 (S6), 46 (S7), 43 (S8), 48 (S9), 36 (S10) and 50 (S11) cumulative score points (S2 Table). When inducing more severe VA, such differentiation using score 1 was not possible. However, score 2 and 3 efficiently reflected the duration of induced VA (MB S11 vs PES S2S3/S2S3S4 p = 0.002 and p = 0.006) (S4 Fig).
Quantity and duration of VA significantly increased with incremental addition of 6, 7, 8 and 10 extrastimuli as documented by arrhythmia score 3 (MB vs PES S2S3/S2S3S4 p = 0.016, p = 0.034, p = 0.01, p = 0.005). Score 2 showed more VA with MB S11 (MB vs PES S2S3/S2S3S4 p = 0.021) (S2 Table). The highest rate of VA induction with the highest cumulative arrhythmia score of 50 points was observed using ten extrastimuli (MB S11, p = 0.005).
Similarly, after isoprenaline both score 2 and score 3 documented the increase of VA (p = 0.041 and p = 0.017, respectively). (S4 Fig).
Discussion
The main findings of the present study are as follows: (i) the conventional PES protocol with up to 3 extrastimuli shows a low yield of VA under baseline conditions, which increases after adrenergic stimulation by isoprenaline administration, (ii) a modified PES protocol including more extrastimuli results in increased VA inducibility, (iii) the increase of VA inducibility by isoprenaline application was more efficient using the MB rather than the conventional PES protocol, and (iv) our novel arrhythmia score documents both the quantity and duration of induced VA.
Since murine in-vivo electrophysiology was established by Berul et al. two decades ago [17], several groups successfully performed PES in mice by using adapted protocols from humans with different stimulation protocols and definitions of VA [18, 22–30]. Particularly, the assessment of the ventricular arrhythmogenic potential in untreated wildtype mice remains challenging, due to the low yield of conventional PES protocols [30]. As previously reported and according to our data induced VA are mainly PVCs. VA can be regularly seen in various species including mice [30], rats [31] and men without disease condition [32]. The clinical significance or prognostic value of single PVC is not particularly high or at least remains unknown in human data [33, 34]. Therefore, the significance as a target VA during EPS should be judged in a measured manner in murine models. Based on these backgrounds, in the present study we have developed our new PES protocol (mini-burst [MB]) with more extrastimuli and new arrhythmia score which can also reflect duration of VA. As shown in Fig 3, MB protocols (particularly with MB S7 or more) enabled induction of short lasting VT (VT <1s). This result suggests that using this MB protocol more definite induction of VT, not merely PVC, may be expected in murine models with arrhythmogenic properties, resulting in the improvement of sensitivity.
Due to the difference of the action potentials of mice and humans the adequate PES protocol can be different. In the present study, we intended to investigate the availability of other PES protocols, which may enable reproducible induction of pathological VA. We have demonstrated the feasibility and accuracy of arrhythmia evaluation in mice when applying PES protocols with additional extrastimuli. We observed that inducible arrhythmias in murine models are predominantly PVCs and VTs <1s, of which a duration > 1 s is rare. In the present study the MB protocol was developed as an acute model for standardized in-depth assessment, quantification and characterization of VA in C57B16/J wildtype mice. The main target of this study was not concluding arrhythmogenic risk for transgenic or cardiovascular disease mouse models. Therefore, the determination of arrhythmogenicity with clinical significance using this MB protocol should be further investigated in the future projects. In order to study the underlying mechanisms of VA, murine electrophysiological studies offer important insights but still demand scrutiny [16, 17].
Systematic review of literature
Most previous studies preferred coupling of two and three extrastimuli, supposedly based on experience in human clinical practice. Noteworthy, VA induction was overall rather low and ranged widely. This might be at least partly explained by the various definition of VA between studies, while most of them could not apply the definitions recommended by recent guidelines [3]. Coupling of more than three extrastimuli seemed to increase VA induction. Meanwhile, it was not clear whether adrenergic activation with isoprenaline yielded more or rather more severe VA.
Electrophysiological study and ventricular PES
We controlled our study for a number of variables known to influence cardiac arrhythmogenicity. Thus, normal cardiac function was assured in a subgroup of tested wildtype C57BL/6J mice by cardiac echocardiography. The core body temperature of the animals was strictly controlled as it may trigger the development of calcium-dependent afterdepolarizations by changing heart rate [35] (S1 Fig).
Under baseline conditions, conventional PES did not succeed in VA induction, while the MB technique was effective in half of the mice tested. Mostly, single PVCs could be induced, which needs to be considered when addressing specific endpoints.
VT in structurally normal hearts can be difficult to induce in PES. In those cases, rapid burst pacing or isoprenaline infusion can be useful as indicated by previous [5, 30] and our findings. As a result of our literature review, we adjusted previous stimulation protocols in attempt to facilitate reproducible VA induction in wildtype mice with a defined protocol. The 2 second-interval between each stimulation episode was adopted from the human electrophysiological test, because our literature review revealed that data on Ca2+ decay after stimulation episodes in mice were scarce. In line with our hypothesis, more extrastimuli compared to conventional PES enabled effective and reproducible VA induction. In this study, the MB protocol was used as an acute model to assess VA in C57Bl6/J wildtype mice.
Arrhythmia assessment
Arrhythmia scoring systems may help to evaluate the vulnerability for VA in given experimental models [4]. In the present study, we aimed to classify VA by their number and duration. The three currently used scoring systems differentially address the different types of VA. The previously established scores 1 and 2 focus on short runs of VA with maximum scoring points for couplets and triplets, respectively. VT is counted equally high. Here, we intended to emphasize the meaning of short runs of ventricular complexes as couplets, triplets and to integrate VT of more or less than one second. Therefore, we have designed a more detailed arrhythmia score better reflecting the duration of VA as compared to the aforementioned scores.
Compared to the arrhythmia score 2, the novel score 3 displayed a clear increase in occurrence and duration of VA by using the modified stimulation protocol. Also, an increase of VA induction could be shown after adrenergic activation by isoprenaline. These findings are consistent with triggered activity as a possible pathomechanism due to changed Ca2+-homeostasis in the absence of structural heart disease [11–13].
We have shown here that effectively induced VA using a modified PES protocol can be more precisely evaluated using the novel arrhythmia scoring system developed in our study. This arrhythmia score may be adopted for electrophysiological studies in mice with arrhythmogenic substrates such as ischemic cardiomyopathy and others, and eventually used to assess ventricular vulnerability. We therefore suggest introducing both the modified stimulation protocol and the novel scoring system in studies on arrhythmogenicity in the mouse heart.
Limitations
There are some limitations in the present study. First, we did not investigate whether and how arrhythmia induction translates into long-term outcome. This is, however, beyond the aim of the present study. Here, we assessed induction of VA in order to present it as an acute model. Second, only C57BL6/J mice were examined. This does not allow translation into other strains, genetically modified mice, and models of structural/ischemic heart disease. Third, we cannot completely exclude calcium accumulation during PES. We adopted 2 seconds intervals between each stimulation episode in the present study. In the clinical setting during PES in human, in which normal heart rate is much slower as compared to mice, the interval between stimulation episodes was set at least 2 seconds traditionally [13, 20]. Louch et al. showed previously in rat that after termination of high frequency stimulation, resting intracellular calcium quickly returns to a normal steady-state condition [36]. Therefore we assume that 2 seconds of resting time between each stimulation episode is a reasonable experimental setting. Fourth, regarding VA inducibility under isoprenaline administration, the lack of statistical significance may be ascribed to the accumulation of intracellular calcium after multiple stimulation procedures. Further researches with randomized sequential orders should be conducted to exclude this possibility, i.e. VA induction with isoprenaline administration followed by VA induction without isoprenaline administration. Additionally the sequential order of MB and PES was not randomized. Higher inducibility during MB, which was always performed before PES, suggested that this inducibility was not due to the intracellular calcium accumulation. Therefore, we believe the validity of our data. Finally, we did not further distinguish between local re-entry and focal mechanisms of VA generation/perpetuation, both of which might play a central role in presented induction protocols. Optical or multi-electrode mapping might be of interest to investigate the mechanisms of induced VA and how they relate to the different stimulation protocols.
Conclusions
A modified in-vivo PES protocol enhances VA inducibility in the mouse heart, with and without pharmacological adrenergic stimulation. Combining such a modified PES protocol with a refined scoring system, VA inducibility may be assessed more efficiently. Implementation of this approach might translate into more efficient use of laboratory animals as well as to improved experimental read-out of murine models of ventricular arrhythmias.
Supporting information
[Figure omitted. See PDF.]
S1 Table. Echocardiographic baseline characteristics.
Echocardiographic baseline characteristics for animals undergoing additional prior to electrophysiological assessments. LV = left ventricle, IVS = intraventricular septum, LVPW = left ventricular posterior wall, MV = mitral valve, AV = aortic valve.
https://doi.org/10.1371/journal.pone.0201910.s001
(DOCX)
S2 Table. Assessment of programmed extrastimulation.
Quantity and duration of VA increased when coupling 6, 7, 8 and 10 extrastimuli as seen with arrhythmia score 3 (p = 0.016, p = 0.034, p = 0.01, p = 0.005). Score 2 was higher only with MB S11 (p = 0.021). n: number of arrhythmic events; animals: number of animals in which VA was observed.
https://doi.org/10.1371/journal.pone.0201910.s002
(DOCX)
S1 Fig. Heart rate of mice is decisively determined by body core temperature.
Heart rate was measured in five mice at different temperature levels. Three zones low, intermediate and high were exposed. Steep change of heart rate occurred at low 32–35°C (Y = 36,34*X—739,5; p = 0.0006) and high >38°C (Y = 39,99*X—995,2; p = 0.0001) temperature, rectally measured. Within an intermediate temperature zone 35–38°C (Y = 13,21*X + 46,37; p = 0.07) the effect on heart rate was minimal.
https://doi.org/10.1371/journal.pone.0201910.s003
(TIFF)
S2 Fig. Programmed electrical stimulation protocol.
For electrophysiological study mice underwent a structured protocol. First, the pacing threshold and the ventricular refractory period (VRP) were defined. Second, programmed electrical stimulation protocol (PES) was performed starting with the Mini-burst (MB) which was followed by the conventional PES. Intervals of 2s were allowed between the pacing maneuvers. Third, after application of isoprenaline (iso) the MB with ten extrastimuli (MB S11) was introduced followed by the conventional PES.
https://doi.org/10.1371/journal.pone.0201910.s004
(TIFF)
S3 Fig. Heart rate after isoprenaline injection.
Adrenergic activation due to injection of isoprenaline (1μg/g i.p.) raised heart rate within 20 seconds. Effect of isoprenaline on heart rate within the first 40 seconds after injection (at time point 0 sec). Data are shown as mean with SEM, one-way ANOVA p = 0.0328 (20 sec), p = 0.0072 (23 sec), p = 0.0075 (40 sec).
https://doi.org/10.1371/journal.pone.0201910.s005
(TIFF)
S4 Fig. Arrhythmia scores according to PES protocols at baseline and during pharmacological adrenergic stimulation.
VA induction is displayed using the novel arrhythmia score (Score 3) in comparison with previously reported arrhythmia scores by Faggioni et al. (7) (Score 1) and Van der Werf et al. (22) (Score 2). VA quantification after MB S11 extrastimulation is discriminated best using Score 2 and 3 at baseline (p = 0.002, p = 0.006) (A) as well as during adrenergic stimulation (isoprenaline) (p = 0.041, p = 0.017) (B).
https://doi.org/10.1371/journal.pone.0201910.s006
(TIFF)
S1 Text. Body core temperature control.
Mice were placed in a supine position on a heated operating table. Body core temperature was measured via a rectal probe (T-type Pod ML312; Rectal Probe for Mice RET-3, ADInstruments). To assess influence of temperature change on heart rate a subset of 5 mice was exposed to a gradual temperature increased from 32 to 41°C over 53 ± 14 minutes. Three zones low, intermediate and high were exposed. Steep change of heart rate occurred at low 32–35°C (r = 0.3494, Y = 36,34*X—739,5; p = 0.0006) and high >38°C (r = 0.4463, Y = 39,99*X—995,2; p = 0.0001) temperature, rectally measured. Within an intermediate temperature zone 35–38°C (r = 0.09803, Y = 13,21*X + 46,37; p = 0.07) the effect on heart rate was minimal (S1 Fig). During EPS experiments body temperature was titrated to 36°C.
https://doi.org/10.1371/journal.pone.0201910.s007
(DOCX)
S2 Text. Echocardiography.
Transthoracic Doppler high-resolution echocardiography (18–32 MHz, Vevo 2100, Visual Sonics) was performed in 6 mice under mild sedation. HR was 465 ± 41 bpm during measurements. LV function was determined by tracing end-diastolic and end-systolic area in parasternal long axis B-mode. Ejection fraction of 55.4 ± 1.4% implied normal LV function. Left ventricular wall thickness was measured in M-mode at the midventricular level. Diastolic function was assessed using the transmitral inflow Doppler in apical 4-chamber view (E/A 1.8 ± 0.3). Aortic valve flow was obtained by Doppler tracing of the LV outflow tract (2212.5 ± 173.3 mm/s). The measurements confirmed with previously published data.
https://doi.org/10.1371/journal.pone.0201910.s008
(DOCX)
S1 Dataset. Summarized datasheet.
The table contains data from 12 animals in our experiments. The electrocardiographic parameters, electrophysiological parameters, echocardiographic parameters, and results of programmed electrical stimulation are listed.
https://doi.org/10.1371/journal.pone.0201910.s009
(XLSX)
Citation: Clasen L, Eickholt C, Angendohr S, Jungen C, Shin D-I, Donner B, et al. (2018) A modified approach for programmed electrical stimulation in mice: Inducibility of ventricular arrhythmias. PLoS ONE 13(8): e0201910. https://doi.org/10.1371/journal.pone.0201910
1. Cabrera-Fuentes HA, Aragones J, Bernhagen J, Boening A, Boisvert WA, Botker HE, et al. From basic mechanisms to clinical applications in heart protection, new players in cardiovascular diseases and cardiac theranostics: meeting report from the third international symposium on "New frontiers in cardiovascular research". Basic Res Cardiol. 2016; 111:69 pmid:27743118
2. Echt DS, Liebson PR, Mitchell LB, Peters RW, Obias-Manno D, Barker AH, et al. Mortality and morbidity in patients receiving encainide, flecainide, or placebo. The Cardiac Arrhythmia Suppression Trial. N Engl J Med. 1991; 324:781–788 pmid:1900101
3. Curtis MJ, Hancox JC, Farkas A, Wainwright CL, Stables CL, Saint DA, et al. The Lambeth Conventions (II): guidelines for the study of animal and human ventricular and supraventricular arrhythmias. Pharmacol Ther 2013; 139:213–248 pmid:23588158
4. Curtis MJ, Walker MJ. Quantification of arrhythmias using scoring systems: an examination of seven scores in an in vivo model of regional myocardial ischaemia. Cardiovasc Res 1988; 22:656–665 pmid:3242835
5. Faggioni M, Hwang HS, van der Werf C, Nederend I, Kannankeril PJ, Wilde AA, et al. Accelerated sinus rhythm prevents catecholaminergic polymorphic ventricular tachycardia in mice and in patients. Circ Res. 2013; 112:689–697 pmid:23295832
6. Jungen C, Scherschel K, Eickholt C, Kuklik P, Klatt N, Bork N, et al. Disruption of cardiac cholinergic neurons enhances susceptibility to ventricular arrhythmias. Nat Commun. 2017; 8:14155 pmid:28128201
7. Garrey WE. THE NATURE OF FIBRILLARY CONTRACTION OF THE HEART.—ITS RELATION TO TISSUE MASS AND FORM1. Annals of Noninvasive Electrocardiology 1914; 3:163–180
8. Vaidya D, Morley GE, Samie FH, Jalife J. Reentry and fibrillation in the mouse heart. A challenge to the critical mass hypothesis. Circ Res. 1999. 85:174–181 pmid:10417399
9. Gilmour RF Jr, Heger JJ, Prystowsky EN, Zipes DP. Cellular electrophysiologic abnormalities of diseased human ventricular myocardium. Am J Cardiol. 1983; 51:137–144 pmid:6849252
10. Josephson ME, Horowitz LN, Farshidi A. Continuous local electrical activity. A mechanism of recurrent ventricular tachycardia. Circulation 1978; 57:659–665 pmid:630672
11. Aistrup GL, Kelly JE, Kapur S, Kowalczyk M, Sysman-Wolpin I, Kadish AH, et al. Pacing-induced heterogeneities in intracellular Ca2+ signaling, cardiac alternans, and ventricular arrhythmias in intact rat heart. Circ Res. 1006; 99:E65–E73 pmid:16960102
12. Antoons G, Mubagwa K, Nevelsteen I, Sipido KR. Mechanisms underlying the frequency dependence of contraction and [Ca(2+)](i) transients in mouse ventricular myocytes. J Physiol. 2002; 543:889–898 pmid:12231646
13. Koller BS, Karasik PE, Solomon AJ, Franz MR. Relation Between Repolarization and Refractoriness During Programmed Electrical Stimulation in the Human Right Ventricle. Implications for Ventricular Tachycardia Induction. Circulation 1995; 91:2378–2384 pmid:7729024
14. National Research Council (US) Committee for the Update of the Guide for the Care and Use of Laboratory Animals. Guide for the Care and Use of Laboratory Animals. 8th edition. Washington (DC): National Academies Press (US) National Academy of Sciences, 2011.
15. Gorressen S, Stern M, van de Sandt AM, Cortese-Krott MM, Ohlig J, Rassaf T, et al. Circulating NOS3 Modulates Left Ventricular Remodeling following Reperfused Myocardial Infarction. PLoS One 2015; 10:e0120961 pmid:25875863
16. Hearse DJ, Sutherland FJ. Experimental models for the study of cardiovascular function and disease. Pharmacol Res. 2000; 41:597–603 pmid:10816328
17. Berul CI, Aronovitz MJ, Wang PJ, Mendelsohn ME. In vivo cardiac electrophysiology studies in the mouse. Circulation 1996; 94:2641–2648 pmid:8921812
18. Petric S, Clasen L, van Wessel C, Geduldig N, Ding Z, Schullenberg M, et al. In vivo electrophysiological characterization of TASK-1 deficient mice. Cell Physiol Biochem. 2012; 30:523–537 pmid:22813543
19. Mitchell GF, Jeron A, Koren G. Measurement of heart rate and Q-T interval in the conscious mouse. Am J Physiol. 1998; 274:H747–751 pmid:9530184
20. The ESVEM trial. Electrophysiologic Study Versus Electrocardiographic Monitoring for selection of antiarrhythmic therapy of ventricular tachyarrhythmias. The ESVEM Investigators. Circulation. 1989; 79:1354–60. pmid:2655967
21. van der Werf C, Kannankeril PJ, Sacher F, Krahn AD, Viskin S, Leenhardt A, et al. Flecainide therapy reduces exercise-induced ventricular arrhythmias in patients with catecholaminergic polymorphic ventricular tachycardia. J Am Coll Cardiol. 2011; 57:2244–2254 pmid:21616285
22. Leroy J, Richter W, Mika D, Castro LR, Abi-Gerges A, Xie M, et al. Phosphodiesterase 4B in the cardiac L-type Ca(2)(+) channel complex regulates Ca(2)(+) current and protects against ventricular arrhythmias in mice. J Clin Invest. 2011; 121:2651–2661 pmid:21670503
23. Zuberi Z, Nobles M, Sebastian S, Dyson A, Lim SY, Breckenridge R, et al. Absence of the inhibitory G-protein Galphai2 predisposes to ventricular cardiac arrhythmia. Circ Arrhythm Electrophysiol. 2010; 3:391–400 pmid:20495013
24. Shusterman V, McTiernan CF, Goldberg A, Saba S, Salama G, London B. Adrenergic stimulation promotes T-wave alternans and arrhythmia inducibility in a TNF-alpha genetic mouse model of congestive heart failure. Am J Physiol Heart Circ Physiol. 2010; 298:H440–450 pmid:19940073
25. Kodirov SA, Brunner M, Nerbonne JM, Buckett P, Mitchell GF, Koren G. Attenuation of I(K,slow1) and I(K,slow2) in Kv1/Kv2DN mice prolongs APD and QT intervals but does not suppress spontaneous or inducible arrhythmias. Am J Physiol Heart Circ Physiol. 2004 286:H368–374 pmid:14684365
26. Nabben M, van Bree BW, Lenaers E, Hoeks J, Hesselink MK, Schaart G, et al. Lack of UCP3 does not affect skeletal muscle mitochondrial function under lipid-challenged conditions, but leads to sudden cardiac death. Basic Res Cardiol. 2014; 109:447 pmid:25344084
27. Prestia KA, Sosunov EA, Anyukhovsky EP, Dolmatova E, Kelly CW, Brink PR, et al. Increased Cell-Cell Coupling Increases Infarct Size and Does not Decrease Incidence of Ventricular Tachycardia in Mice. Front Physiol. 2011; 2:1 pmid:21423411
28. Li N, Timofeyev V, Tuteja D, Xu D, Lu L, Zhang Q, et al. Ablation of a Ca2+-activated K+ channel (SK2 channel) results in action potential prolongation in atrial myocytes and atrial fibrillation. J Physiol. 2009; 587:1087–1100 pmid:19139040
29. Zhang Z, He Y, Tuteja D, Xu D, Timofeyev V, Zhang Q, et al. Functional roles of Cav1.3(alpha1D) calcium channels in atria: insights gained from gene-targeted null mutant mice. Circulation 2005; 112:1936–1944 pmid:16172271
30. Maguire CT, Wakimoto H, Patel VV, Hammer PE, Gauvreau K, Berul CI. Implications of ventricular arrhythmia vulnerability during murine electrophysiology studies. Physiol Genomics. 2003; 15:84–91 pmid:12888626
31. Ng FS, Kalindjian JM, Cooper SA, Chowdhury RA, Patel PM, Dupont E, et al. Enhancement of Gap Junction Function During Acute Myocardial Infarction Modifies Healing and Reduces Late Ventricular Arrhythmia Susceptibility. JACC Clin Electrophysiol. 2016; 2:574–582 pmid:27807593
32. Yamada T, Yoshida N, Doppalapudi H, Litovsky SH, McElderry HT, Kay GN. Efficacy of an Anatomical Approach in Radiofrequency Catheter Ablation of Idiopathic Ventricular Arrhythmias Originating From the Left Ventricular Outflow Tract. Circ Arrhythm Electrophysiol. 2017; 10:e004959 pmid:28500177
33. Ataklte F, Erqou S, Laukkanen J, Kaptoge S. Meta-analysis of ventricular premature complexes and their relation to cardiac mortality in general populations. Am J Cardiol. 2013 112:1263–70 pmid:23927786
34. Qureshi W, Shah AJ, Salahuddin T, Soliman EZ. Long-term mortality risk in individuals with atrial or ventricular premature complexes (results from the Third National Health and Nutrition Examination Survey). Am J Cardiol. 2014 114:59–64 pmid:24819898
35. Mugelli A, Cerbai E, Amerini S, Visentin S. The role of temperature on the development of oscillatory afterpotentials and triggered activity. J Mol Cell Cardiol 1986; 18: 1313–1316 pmid:3820318
36. Louch WE, Stokke MK, Sjaastad I, Christensen G, Sejersted OM. No rest for the weary: diastolic calcium homeostasis in the normal and failing myocardium. Physiology (Bethesda). 2012; 27: 308–23. pmid:23026754
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2018 Clasen et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Background
Electrophysiological studies in mice, the prevailing model organism in the field of basic cardiovascular research, are impeded by the low yield of programmed electrical stimulation (PES).
Objective
To investigate a modified approach for ventricular arrhythmia (VA) induction and a novel scoring system in mice.
Method
A systematic review of literature on current methods for PES in mice searching the PubMed database revealed that VA inducibility was low and ranged widely (4.6 ± 10.7%). Based on this literature review, a modified PES protocol with 3 to 10 extrastimuli was developed and tested in comparison to the conventional PES protocol using up to 3 extrastimuli in anesthetized wildtype mice (C57BL/6J, n = 12). Induced VA, classified according to the Lambeth Convention, were assessed by established arrhythmia scores as well as a novel arrhythmia score based on VA duration.
Results
PES with the modified approach raised both the occurrence and the duration of VA compared to conventional PES (0% vs 50%; novel VA score p = 0.0002). Particularly, coupling of >6 extrastimuli raised the induction of VA. Predominantly, premature ventricular complexes (n = 6) and ventricular tachycardia <1s (n = 4) were observed. Repeated PES after adrenergic stimulation using isoprenaline resulted in enhanced induction of ventricular tachycardia <1s in both protocols.
Conclusion
Our findings suggest that the presented approach of modified PES enables effective induction and quantification of VA in wildtype mice and may well be suited to document and evaluate detailed VA characteristics in mice.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer




