To compare trabeculectomy and EX-PRESS device implantation procedures for treating glaucoma and evaluate changes in corneal endothelial cell density (CECD).
Methods
This study prospectively evaluated changes in the CECD in 60 eyes of 60 patients who underwent trabeculectomy and 50 eyes of 45 patients who underwent EX-PRESS device implantation. Baseline patient data recorded included age at surgery, sex, type of glaucoma medications, and lens status. Using a noncontact specular microscope, corneal specular microscopy was performed preoperatively at the central cornea and then at 6, 12, 18 and 24 months after surgery. CECD before and after surgery was compared using a paired t-test.
Results
There was a significant decrease in the IOP and number of antiglaucoma medications in both groups after the surgery. The mean CECD in the trabeculectomy group was 2505 ± 280 cells/mm2 at baseline, while it was 2398 ± 274 cells/mm2 (P < 0.001), 2349 ± 323 cells/mm2 (P < 0.001), 2293 ± 325 cells/mm2 (P < 0.001), and 2277 ± 385 cells/mm2 (P = 0.003) at 6, 12, 18, and 24 months, respectively. However, the CECD in the EX-PRESS group was 2377 ± 389 cells/mm2 at baseline, while it was 2267 ± 409 cells/mm2 (P = 0.007), 2292 ± 452 cells/mm2 (P = 0.043), 2379 ± 375 cells/mm2 (P = 0.318), and 2317 ± 449 cells/mm2 (P = 0.274) at 6, 12, 18, and 24 months, respectively.
Conclusions
As compared to trabeculectomy, EX-PRESS device implantation appears to be a safer procedure with regard to the endothelial cell loss risk.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer