© 2018 Sánchez Muñoz-Torrero et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

An automated method for measuring arterial path length with devices that determine pulse wave velocity (PWV) in peripheral arteries is frequently applied. We aimed to compare arterial path length measurements based on mathematical height-based formulas with those measured manually and to assess whether the ankle-brachial difference (abD-PWV) measured with the VOPITB device is comparable to that obtained by manual measurements. In 245 patients, a metric measuring tape was used to determine the arterial path length from the suprasternal notch to the midpoint of the VOPITB cuffs wrapped around the extremities, and the results were compared with those obtained with height-based formulas. We examined the relationship between the abD-PWV measured with both methods. The arterial path length measured manually was shorter than that calculated automatically by 5 ± 2 and 30 ± 4 cm—of 13% and 21% for the arms and legs, respectively (difference of 13% and 21%). As a result, the abD-PWV calculated with the automatic method was greater (automatic abD-PWV vs. manual: 462 ± 90 vs. 346 ± 79 cm/s). The Blant Altman plot showed a percentage error of: 15,2%, 7,5% and 17,3% for heart-brachial, heart-ankle length and abD-PWV respectively. In conclusion there were significant differences between manual and automated arterial length measurements and it translates into difference abD-PWV calculate from both methods. However, the Bland-Alman plot showed that abD-PWV was comparable for both techniques. The advantages of height-based formulas for the calculation of arterial path lengths suggest that they may be the recommended method for measuring the abD-PWV.

Details

Title
Automatic or manual arterial path for the ankle-brachial differences pulse wave velocity
Author
Sánchez Muñoz-Torrero, Juan Francisco; Calderón-García, Julián Fernando; De Nicolás-Jiménez, Jorge Manuel; García-Ortiz, Luis; Rodilla-Salas, Enrique; Gómez-Marcos, Manuel Angel; Suárez-Fernandez, Carmen; Cordovilla-Guardia, Sergio; Sergio Rico-Martín ⨯
First page
e0206434
Section
Research Article
Publication year
2018
Publication date
Nov 2018
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2127944813
Copyright
© 2018 Sánchez Muñoz-Torrero et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.